Loading...
HomeMy WebLinkAboutA14-0043 Spec Sheets.pdf it LI c SIMPLEXGRINNELL 6240 Smith Road S mp/exGrinnell Denver, Colorado 80216 www.simplexqrinnell.com Tele: (303)355-0500 Fax: (303) 355-0615 Fire Alarm Product Data Submittal for: The Lodge at Vail Penthouse Unit 572 Remodel 174 Gore Creek Drive Vail, CO 81657 Prepared for: SRE Building Associates PO Box 6376 Vail, CO 81658 tqco SimplexGrinnell 6240 Smith Road Denver, Colorado 80401 Sales: (303) 355-0500 Service: (303) 355-0500 Fax: (303) 355-0615 PROJECT: The Lodge at Vail Penthouse Unit 572 Remodel PREPARED FOR: SRE Building Associates TYPE: DESCRIPTION: 4098-9733 HEAT SENSOR 4098-9714 PHOTO SENSOR 4098-9794 SENSOR BASE W/SOUNDER 4090-9051 SUPERVISED IAM C01224T SYSTEM SENSOR CO DETECTOR 4902-9721 SPEAKER WHITE TRUEALERT 4903-9196 SPKR/STROBE 15CD CEILING aSimplex TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; Sounder Base 4098-9794,for use with MEA (NYC) Acceptance" TrueAlarm Photoelectric and Heat Sensors Features! Modular TrueAlarm sensor base with built-in electronic alarm sounder: • Piezoelectric sounder provides high output(88 dBA) ,.,A . with low current requirements(20 mA) t= 14 'xi I' . u : • For use with interchangeable TrueAlamt photoelectric or heat sensors(ordered separately) Sounder operation details: TrueAlarm Photoelectric Sensor Mounted in • Powered from 24 VDC or from a compatible Sounder Base 4098-9794` Notification Appliance Circuit(NAC) • Synchronized via communications or by the NAC,if TrueAlarm Analog Sensing Description NAC powered** • Sounder can be manually activated from the control panel Sounder bases combine an audible notification appliance • Sensor and sounder operation is listed to UL Standard 268 and a TrueAlarm analog sensor to provide: • Sounder operation is also listed to UL Standard 464 Digital Communication of Analog Sensing. as an audible notification appliance Sensors provide an analog measurement that is digitally TrueAlarm analog sensing operation: communicated to the control panel where it is analyzed • Analog sensor information is digitally communicated and an average value is determined and stored.An alarm to the control panel via ZDNet or MAPNET II or other abnormal condition is determined by comparing two-wire communications the sensor's present value against its average value. • Sensor information is processed by the control panel Intelligent Data Evaluation.Monitoring each sensor's to determine sensor status average value provides a software filtering averaging For use with the following Simplex®products: process that compensates for environmental factors(dust, • 4100ES,4010ES,4010,and 4100U Series control dirt,etc.)and component aging,providing an accurate panels;and 4008 Series control panels with reduced reference for evaluating new activity.The result is a feature set(refer to data sheet 54008-0001 for details) significant reduction in the probability of false or • 4020,4100,and 4120 Series control panels,and nuisance alarms caused by shifts in sensitivity,either up Universal Transponders equipped for MAPNET H or down. operation Control Panel Selection.Peak activity per sensor is General features: stored to assist in evaluating specific locations.The alarm • Louvered smoke sensor design enhances smoke set point for each TrueAlarm sensor is determined at the capture by directing flow to chamber;entrance areas control panel,selectable as more or less sensitive as the are minimally visible when ceiling mounted individual application requires. • Designed for EMI compatibility • Magnetic test feature is provided Timed/Multi-Stage Selection.Alarm set points can be Optional accessories include remote LED alarm programmed for timed automatic sensitivity selection • indicator and output relays (such as more sensitive at night,less sensitive during day).Control panel programming can also provide Additional base reference: multi-stage operation per sensor.For example,a 0.2% • For standard bases,refer to data sheet S4098-0019 level may cause a warning to prompt investigation while a • For isolator bases,refer to data sheet S4098-0025 2.5%level may initiate an alarm. • For photo/heat sensors,refer to data sheet S4098-0024 Sensor Alarm and Trouble LED Indication.Each (single address)and S4098-0033(dual address) sensor base's LED pulses to indicate communications with the panel.If the control panel determines that a • This product has been approved by the California State Fie Marshal(CSFM)pursuant to Section sensor is in alarm,or that it is dirty or has some other type 13144.1 of the California Health and Safety Code.See CSFM listings 7300-0026:217 and of trouble,the details are annunciated at the control panel 7271-0026:231 for allowable values and/or conditions concerning maledal presented in this and that sensor base's LED will be turned on steadily. Accepted for use—City of New York Departmental Buildings—MEA35-93E.Additional listings may be applicable,contact your local Simplex product supplier for the latest status Listings During a system alarm,the control panel will control the and approvals under Simplex lime Recorder Co.are the property of Tyco Fire Protection LEDs such that an LED indicatinga trouble will return to Products. "Total quantity of sounder bases available for coding on the same communications channel may vary pulsing to help identify the alarmed sensors. with panel application and availability of NAC power.Refer to specific control panel requirements. 84098-0028-9 612014 Additional Sounder Base Features,', Mountin• Reference Base mounted address selection allows the address to remain with its programmed location when the sensor is removed for service or type change.Access is from the Electrical Box Requirements:(boxes are by others) front under the removable sensor. Without relay:4"octagonal or 4"square,1-1/2"deep;single gang, 2"deep Automatic sensor type identification provides With relay:4"octagonal or 4"square,1-1/2"deep,with 1-1/2" default sensitivity when substituting sensor types. extension ring Different sensor types can be easily interchanged to meet 4"(102 mm)Square Box 4"(102 mm)Octagonal Box specific location requirements.This feature also allows surface mount reference intentional sensor substitution during building Ernmszoim fritio .,_„ - - -- construction.When conditions are temporarily dusty, instead of covering the smoke sensors(causing them to be 1-1/2"(3a mm) Cr;int disabled),heat sensors may be installed without reprogramming the control panel. } Flush mount reference,mount even with final Integral red LED indicates power-on by pulsing,or surface,or with up to 1/4"(6.4 mm)maximum recess alarm or trouble when steady on.The exact status is annunciated at the fire alarm control panel. Optional 4098-9822 Relay Fire alarm control panel provides: ��� (Mounts in base electrical box Note:Single gang and requires additional • Peak value logging allowing accurate analysis of each adapter plate(RACO volume,see notes below) sensor for individual sensitivity selection No.787 or equal)is required when using a" ® • Sensitivity monitoring satisfying NFPA 72 sensitivity square box(by others) Relay size: �� �,jl, • testing requirements;automatic individual sensor • calibration check verifies sensor integrity � N.....,.... (64 mm X 38 mmlx q� rili • Automatic environmental compensation,multi-stage 25.4 mm),3.75 cubic inches alarm operation,and display of sensitivity directly in percentper foot 6-3/8"Dia. x 1/4"th 4098-9832 Adapter Plate,requjred for mounting • Ability to display and print detailed sensor \-- f to surface mounted boxes(mounts inverted) information in plain English language N 6-7/16"(164 mm) 14 Accessories T 1/8 4098-9822, LED Annunciation Relay activates when (29 mm um base LED is on steady,indicating a local alarm or trouble. • y 7. Contacts are DPDT,rated 2 A @ 30 VDC; 1/2 A @ 120 VAC for transient suppressed loads(requires external LED status Sound output louvers 24 VDC coil power). - indicator extend from front to side EI 2098-9808,Remote red LED Alarm Indicator mounts on 1111111111111111111111/ a single gang box to provide status indications where the �1°�MEDIESSB IDE1111111111 sensor location may not be readily visible. A� - • (Photoelectric sensor shown for reference) NOTES: 1. Review actual wire size,wire count,box type,and whether 4098-9822 relay is used before determining box size. 2. Mounting to flush mounted box also fits single gang handy box, ALARM 2-1/8"(51 mm)deep if wiring allows.(Not applicable if 4098-9822 ® relay is used.) 3. For surface mounted boxes,use 4"square box with single gang adapter plate(RACO No.787 or equal,by others)or 4"octagonal 43 Simplex box,both require 4098-9832 Adapter Plate. 4. When 4098-9822 relay is used,mount relay in electrical box and use e 1-1/2"extension ring(by others)on 4"square or octagonal box of 1-1/2"or2-1/8"depth as required. 5.Refer to Installation Instructions 574-707 for additional information. 2098-9808 Remote LED Alarm Indicator 2 54098-0028-9 6/2014 TrueAlarm Analog Sensor Features 4098-9733 Heat Sensor Sealed against rear air flow entry TrueAlarm heat sensors are self-restoring and provide rate Electronics are EMIIRFI shielded compensated,fixed temperature sensing,selectable with or without rate-of-rise temperature sensing.Due to its Heat sensors: small thermal mass,the sensor accurately and quickly • Selectable rate compensated,fixed temperature measures the local temperature for analysis at the fire sensing with or without rate-of-rise operation alarm control panel. • Rated spacing distance between sensors: Rate-of-rise temperature detection is selectable at the Fixed Temp. UL&ULC FM Spacing,Either Fixed control panel for either 15°F(8.3°C)or 20°F(11.1°C) Setting Spacing Temperature Setting per minute.Fixed temperature sensing is independent of 135°F 60 ft x 60 ft 20 ft x 20 ft(6.1 m)for fixed rate-of-rise sensing and programmable to operate at (57.2°C) (18.3 m) temperature only;RTi=Quick 135°F(57.2°C)or 155°F(68°C).In a slow developing 50 ft x 50 ft(15.2 m)for fixed fire,the temperature may not increase rapidly enough to 155°F 40 ft x 40 ft temperature with either rate-of-dse (s6 C) (12.2 m) selection;RTI=Ultra Fast operate the rate-of-rise feature.However,an alarm will be initiated when the temperature reaches its rated fixed Smoke Sensors: temperature setting. • Photoelectric technology sensing TrueAlarm heat sensors can be programmed as a utility • 360°smoke entry for optimum response device to monitor for temperature extremes in the range • Built-in insect screens from 32°F to 155°F(0°C to 68°C).This feature can provide freeze warnings or alert to HVAC system problems.Refer to specific panels fm availability. 4098-9714 Photoelectric Sensor i 6-7116"(1sa mm) TrueAlarm photoelectric sensors use a stable,pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivityare available 2-9/16" 1111111111 for each individual sensor,ranging from 0.2%to 3.7%per (65 mm) foot of smoke obscuration. Sensitivities of 0.2%,0.5%, .'„ll■l. and 1%are for special applications in clean areas. Standard sensitivities are 1.5%,2.0%,2.5%,3.0%,and 3.7%.Application type and sensitivity are selected and then monitored at the fire alarm control panel.* 4098-9733 Heat Sensor with 4098-9794 Sounder Base The sensor head design provides 360°smoke entry for optimum smoke response.Due to its photoelectric WARNING: In most fires, hazardous levels of smoke operation,air velocity is not normally a factor,except for and toxic gas can build up before a heat detection impact on area smoke flow. device would initiate an alarm. In cases where Life Safety is a factor,the use of smoke detection is highly 6-7/16"(164MM) recommended. Application Reference Sensor locations should be determined after careful 2-5116" consideration of the physical layout and contents of the (58 MM) m) c r ours area to be protected.Refer to NFPA 72,the National Fire ‘Ntomamoluutummiemmillosir Alarm and Signaling Code.On smooth ceilings,smoke sensor spacing of 30 ft(9.1 m)may be used as a guide. For detailed application information,refer to 4098 4098-9714 Photoelectric Sensor with Sounder Base Detectors, Sensors, and Bases Application Manual,Part Number 574-709.* *For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0028-9 6/2014 TrueAlarm Analog! Sensin r Product Selection Chart TrueAlarm Sounder Base* Model Description Compatibility Mounting Requirements, Sounder Base with connections Sensors:4098-9714 and 4098-9733 4098-9794 for Remote LED Alarm Indicator Refer to page 2,mounting reference or Unsupervised Relay Options:2098-9808 remote LED alarm indicator or 4098-9822 relay TrueAlarm Sensors (ordered separately) Model 'Description 7. Mounting Requirements' 4098-9714. Photoelectric Smoke Sensor 4098-9733. Heat Sensor Refer to page 2,mounting reference Sounder Base Accessories(ordered separately if required) Model Description Mounting Requirements 4098-9832 Adapter Plate,required for surface mounted 4"electrical boxes Refer to page 2,mounting reference 2098-9808 Remote red LED Alarm Indicator on single gang Single gang box,1-1/2"minimum depth Choose one if stainless steel plate - required Relay,tracks base LED status(unsupervised,to be Mounts in base electrical box(requires 1-1/2" 4098-9822 mounted only in base electrical box) extension on 4"square or octagonal box) *Refer to data sheet S4098-0019 for other compatible bases.Refer to Installation Instructions 574-707 and Application Manual 574-709 for additional information. S•ecifications General Operating Specifications Communications and Sensor Supervisory Power IDNet or MAPNET II communications,auto-selected, 1 address per base Communications and Sounder Power Connections Screw terminals for in/out wiring,18 to 14 AWG(0.82 mm2 to 2.08 mm2) Current 1 mA typical supplied from communications,no impact to alarm current Remote LED Alarm Indicator LED Connections Color coded wire leads, 18 AWG(0.82 mm2) UL Listed Temperature Range 32°F to 100°F(0°C to 38°C) Operating With 4098-9733 32°F to 122°F(0°C to 50°C) Temperature Range Wth 4098-9714 15°F to 122°F(-9°C to 50°C) Storage Temperature Range 0°F to 140°F(-18°C to 60°C) Humidity Range 10 to 95%RH Smoke Sensor 414, Air velocity is 0-400011/min(0-1220 m/min) Ambient Ratings Photoelectricric Sensor Housing Color Frost White Sounder Operation Sounder Voltage 18 to 32 VDC from steady external source or from NAC Alarm Current(Sounder On) 20 mA @ 24 VDC,24 mA maximum @ 32 VDC 88 dBA minimum @ 10 ft(3 m)per UL Standard 464,Audible Signaling Sounder Output Appliances and UL Standard 268,Smoke Detectors for Fire Protective Signaling Systems Sounder Power Supervision Supervised Select for continuous 24 VDC power,loss of power is communicated to panel (Selectable) Unsupervised Select when connected to NAC for sounder power,NAC provides supervision NAC Powered Operation When in alarm,will sound when NAC is in alarm,allowing synchronized pattern(Temporal or March Time,etc.)controlled by the NAC 4098-9822 Unsupervised Relay Option Externally Supplied Relay Voltage 18-32 VDC,steady source recommended(wires to remote LED leads) Alarm Current 13 mA from separate 24 VDC supply Contact Ratings, DPDT contacts for Power limited rating:2 A @ 30 VDC resistive/suppressed loads Non-power limited rating:1/2 A @ 120 VAC Relay Operation Tracks base LED status,relay is on with trouble or alarm at the base TYCO,SIMPLEX,and the product names listed fir this material are marks and'or registered marks.Unauthorized use is.strictly prohibited NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association(NEPA). fieSim p l ex Tyco Fire Protection Products•Westminster, MA•01441-0001 •USA S4098-0028-9 6/2014 www.simplex-fire.com 's 2014 Tyco Fire Protection Products,411 rights reserved All specifications and other information showmrere current as fdocument revision date and are subject to change without notice. EtSimplex Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; IDNetTM and MAPNET Il® Communicating Devices, MEA (NYC)Acceptance* Individual Addressable Modules (IAMs) Features IDNet or MAPNET II addressable communications r supply both data and power over a single wire pair iSI Roof ra to provide**: osa-ooal swampuu C • Supervised Class B monitoring of normally open,dry1f lin 11131 Uk4ifCE' contacts ,,. y .m Yv 4 • Total wiring distance from IAM to supervision resistor(s)of up to 500 ft(152 m) o t000000ti 11'19-" • Monitored connection is compatible with Simplex 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications 4090-9001 Supervised IAM • For use in indoor locations up to 158°F(70°C)such as (shown approximately 3/4 size) attic spaces or similar applications For use with following Simplex control panels: • Model Series 4008,4010,4010ES,4100U and 4100ES fire alarm control panels for IDNet communications • Model Series 4100/4100U/4100ES,4120,4020,and S_ 2120 Communicating Device Transponders(CDTs) equipped with MAPNET ll communications Model 4090-9001: • Enclosed design minimizes dust infiltration • Mounts in standard single gang electrical box • Screw terminals for wiring connections • Visible LED flashes to indicate communications • Optional covers are available to allow LED to be viewed after installation(requires mounting bracket, hown a ppr rimSupa ely d IAM (shown approximately 3/4 size) ordered separately) Model 4090-9051: • Encapsulated design for extended exposure to high Descri•tion humidity(LED is not present on this model) • Color coded 18 AWG leads for wiring Individual addressable modules(IAMB)receive IDNet communications provides current limited both power and communications from a two-wire monitoring: MAPNET II or IDNet circuit.They provide location • Provides monitoring of tamper switch(supervisory) specific addressability to a single initiating device(such and waterflow switch(alarm)on same circuit using as single station smoke detector alarm contacts or heat detector contacts)or multiple devices at the same location one point by monitoring normally open dry contacts and the wiring • Available with IDNet communications only to an end-of-line resistor. Multiple operation modes are available and are Model 4090-9001 is packaged in a thermoplastic selectable at the control panel: housing and provides screw terminal connections and a • Contact closure status can be tracked status indicating LED. • Momentary contact closure conditions can be selected at the panel to be latched or tracked(not available with the Model 4090-9051 is an encapsulated package with wire 2120 CDT) leads.It does not provide a status indicating LED. UL listed to Standard 864 • These products have been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document.It is subject to re-examination,revision,and possible cancellation.Accepted for use—City of New York Department of Buildings—MEA3S93E.Additional listings may be applicable;contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the properly of Tyco Safety Products Westminster. S4090-0001-10 O•eration Current Limited Operation Applications Contact Closure. Closure of the monitored contact(s) For use with IDNet communications only,these initiates an alarm or other response as programmed at the IAMB can provide quad-state sensing of normal,open fire alarm control panel.An open in the monitored circuit circuit,short circuit,and current limited conditions. wiring will cause a trouble to be reported. (Program type is"T-sense.")With the proper end-of-line Panel Selections. Selections can be made at the control and current limiting resistors,dual functions such as panel to maintain the alarm condition if the initiating tamper switch and waterflow switch monitoring can be device contacts are momentary,such as from a determined and communicated by a single addressable rate-of-rise heat detector,or to track the device contact point. status(not available with the 2120 CDT). IAM Product Selection Model Description , 4090-9001 Supervised IAM,mounted in thermoplastic housing with screw terminals;see applicable options below 4090-9051 Supervised IAM, encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 For semi-flush mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, 4090-9807 For surface mounted box includes mounting screws,galvanized steel 4090-9810 Mounting bracket,mounts IAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses (ordered separately as required) Model Reference No. Description ' .'iii 4081-9004 733-886 6.8 kl1, 1/2 W;Standard end-of-line resistor harness for N.O. contact supervision 4081-9003 733-896 4.7 kO, 1/2 W Use for current limited monitoring applications 4081-9005 733-984 1.8 k0, 1/2 W S•ecifications Electrical Power and Communications MAPNET II or IDNet,auto selected, 1 address per IAM Input Requirements Normally open,dry contacts Screw terminals for in/out wiring, 18 to 14 AWG wire 4090-9001 (0.82 mm2 to 2.08 mm2) Wire Connections 4090-9051 Color coded wire leads, 18 AWG(0.82 mm2), 8"long(203 mm) Installation Instructions 574-331 for 4090-9001; 579-572 for 4090-9151 Reference Documents Field Wiring Diagrams 842-073 for IDNet operation; 841-804 for MAPNET II operation Wiring Distances 500 ft(152 m)maximum without protectors Distance from IAM to Contacts 400 ft(122 m)maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, MAPNET II or 2500 ft(762 m)maximum from fire alarm control panel IDNet Communications 10,000 ft(3048 m)maximum total wiring distance(including T-Taps) Mechanical 4090-9001 1-9/16"W x 1-3/4"H x 1-1/4"D(40 mm x 44 mm x 32 mm) Dimensions 4090-9051 1-9/16"W x 1-9/16"H x 9/16"D(40 mm x 40 mm x 14 mm) Housing Material,4090-9001 Black thermoplastic Encapsulation Material,4090-9051 Epoxy, beige Temperature Range 32°to 158°F(0°to 70°C); intended for indoor operation Humidity Range Up to 93% RH at 100°F(38°C) 2 64090-0001-10 Mountin• Information , -01� 4090-9001 IDNet altar" Field wiring shown supervised IAM - Nu for reference _ _ T wn�nr,u,��w�xovo�w o su41vI�31�u� �1 is irni.s+ni "O pan coot lira. LED viewing port r �� 'noouniPffilmwommti tt`- Single gang electrical so ® ,I box 2-1/2"(64mm) minimum depth (supplied by others) 3 Address setting under resealable label et Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate I_. O OO OO � � Light pipe for ® / LED viewing \ 4-1/4" ` - 4-1/2" (1 08 mm) (114 mm) DISCONNECT POWER DISCONNECT POWER BEFORE SERVICING BE.ORE SERVICING E 00 O \-\\1. ° I II r2-1/2" 2-13/16" (64 mm) (72 mm) 4090-9806, Trim plate for 4090-9807,Trim plate for 4090-9810 Mounting semi-flush mounted box surface mounted box bracket, ordered separately NOTE:These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 3 S4090-0001-10 4090-9051 Mountin• Information Address setting is ® 0111. at rear of housing , 4090-9051 �I I Encapsulated I SupervisededIAIAM o nei 2,7 • Single gang electrical box 2-1/2"(64mm) minimum depth (supplied by others) °' Single gang blank cover plate and mounting screws(supplied by others) Tyco is a registered trademark of Tyco International Services GmbH and is used under license,Simples,the Simplex logo,IDNet,and MAPNLTII are nademar/cs of Tyco International Ltd and its affiliates and are used under license. S S i rn p I ex SimplexGrinnell LP Westminster•Westminster,MA•01441-0001•USA 54090-0001-10 '® www.simplexgrinnelLcom 02011 Yyrm.All rights reserved Allspecrficanons and other information shorten eere current as of document revision date mid are subject to change tirlthaui notice. C01224T and C01224TRCarbon Monoxide ;.• _ __ \ \ Detectors 4 ' with Realest'Technology The System Sensor C01224T and C0122477(round) Carbon Monoxide(CO)Detectors use a highly accurate and reliable electrochemical sensing cell to provide early warning of dangerous CO levels. Features With RealTest®technology,the CO gas sensing cell used in • RealTest®enables a functional test using canned CO the C01224T and 001224TR CO detectors can be tested using a CO gas agent,fully meeting the requirements of NFPA 720:2009. • Full compliance with UL 2075 Simply put the detector into RealTest mode;spray a small amount • A code-required trouble relay of CO into the detector per the installation instructions,and within • Wiring supervision with SEMS terminals seconds the detector will alarm,indicating successful gas entry.(See the reverse page or the user manual for complete instructions.) • A six-year end-of-life timer • 12/24 VDC When dangerous amounts of CO are detected,the C01224T and C01224TR detectors alert residents by sounding and flashing a • A low current draw of 20 mA in standby and 40 mA in alarm temp 4 signal alarm.With 24/7 central station monitoring, residents • Versatile mounting for wall and ceiling are guaranteed protection whether they are away from home, • Accurate and reliable electrochemical sensing technology sleeping,or already suffering from the effects of CO. • Optional CO-PLATE CO Detector Replacement Plate to upgrade The 001224T and 001224TR are designed for system operation. previously installed competitor detectors to the C01224T These detectors are fully listed to UL 2075 and offer a code- required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station.The C01224T and 00122410 also use SEMS-type terminal Philips head screws for quicker and more positive wiring connections and code-required wiring supervision.With a low current draw,these detectors enable more devices to be connected to the panel,limiting the need to purchase extra power supplies or more expensive panels.As 12/24 VDC detectors,the C01224T and C01224TR will operate on most industry security and fire alarm control panels. Agency Listings LISTED r 1 ITS E307`.95 E3C4075 5276-16530194 C01224T and C01224TR Carbon Monoxide Detector Specifications Carbon monoxide(CO)detector shall be a system-connected System Sensor model number C01224T or C01224TR listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors.The detector shall be equipped with a sounder and a trouble relay.The detector's base shall be able to mount to a single-gang electrical box or direct(surface)mount to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide dual-color LED indication that blinks to indicate normal standby,alarm,or end-of-life.When the sensor supervision is in a trouble condition,the detector shall send a trouble signal to the panel.When the detector gives a trouble or end-of-life signal,the detector shall be replaced.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry.The detector shall perform in the detection of CO up to 12,000 feet above sea level and alarm within the time specified by ANSI/UL 2034 for CO concentrations of 70, 150 and 400 parts per million(ppm),as verified by a Nationally Recognized Test Laboratory. :.',t`,•,C, c�'I ..!kr>» K M_.. ., i .%i_f _ „ . .. ..'f ., ,.- ,.,�. , -- s ,x...y_, .,., -'. Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standi;y Current 20 mA Alarm Curreuit 40 mA(75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC PhyapalS oafaz (Pns. 2 .,. „ ,. _, Size:C01224T Length:5.1 in,Width: 3.3 in,Height: 1.31n Cal 224TR Diameter:6 in,Height: 1.3 in Approxiutate Weight C01224T:7 oz;C01224TR: 11 oz Operating Temperature Range 32'F to 1049 F(0°C to 40°C) Oper.atpng Humidity Range 22 to 90%RH input Terminals 14 to 22 AWG Mounting Single-gang back box;surface mount to wall or ceiling Operation Modes Normal(standby) Blink 1 per minute — — Alarm — Blink in temp 4 pattern Sound in temp 4 pattern RealTeste Feature: The System Sensor C01224T and C01224TR Carbon Monoxide Detectors with RealTest enable evaluation of the functionality of the CO sensing cell using a canned CO test agent. im • } Push and hold the Test/Hush button for Spray canned CO agent into Verify CO sensing at the two seconds to enter RealTest mode.The the detector. control panel.The detector will green LED will flash once every second automatically exit RealTest alarm to indicate RealTest mode has started. mode after about 20-60 seconds. NOTE:Check with local codes and the AHJ to determine if a functional gas test is desired for an installation. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes(except in RealTest mode). ' Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. •End-of-Life Timer: After the detector's internal sensor has reached the end of its life,a trouble signal will be sent to { "'� the panel to indicate it is time to replace the detector.An electrochemical CO detector lifespan is about six years.The detector must be replaced by the date marked on the inside of the product CO-PLATE: System Sensor also offers the CO-PLATE CO Detector Replacement Plate to cover the footprint(when necessary)of previously installed competitive carbon monoxide detectors that require replacement. Ordering Information Co-PLATE C01224T 12/24 volt,4-wire system-monitored carbon monoxide detector with RealTest®Technology C01224TR 12/24 volt,4-wire system-monitored round carbon monoxide detector with RealTest®Technology CO-PLATE CO detector replacement plate to cover the footprint of previously installed competitive detectors as necessary 4 3825 Ohio Avenue•St.Charles, IL 60174 �s=oiz sys�am sanm,. ,", Phone 800-SENSOR2 Fax 630-377-6495 Pf°a,,,:rsp«modmf,suet:tach«:ee],Theo(a-rS]V=,v:et;ya�mata sor rr SEALSCAT r�<<„«e�,p,m:,c.�rnrma�sci,,umye:h aiaoeiMr.,,:mu:is data sheet. wwwsystemsensorcom s�.o,,oi oa•,na aSimplex Multi-Application Peripherals UL, ULC, CSFM Listed;FM Approved; Audible Notification Appliances MEA (NYC)Acceptance* Speakers, 25 or 70.7 VRMS, Wall or Ceiling Mount Features — s Fire alarm speakers with models for ceiling or wall mount: • Four inch cone(102 mm)provides high quality tone and voice reproduction • Multi-tapped design provides output power of%a,1/4, 1, , i'. or 2 W with either 25 or 70.7 VRMS input • In/out wiring terminals for 18 AWG to 12 AWG ! • Mounts to 4"square outlet box, 1 Ye"deep with 1 ''A" deep box extension . may • Capacitor input for connection to supervised notification appliance circuits l ,a l tax • Rugged,high impact,flame retardant thermoplastic housings Rectangular Wall Mount Speakers are Available • UL listed to Standard 1480 as Red with White"Fire" Lettering and • ULC listed to Standard S541,refer to page 4 for White with Red"Fire" Lettering required minimum wattage tap per housing type • Compliant with NFPA 72,520 Hz Low Frequency ,a Signal Requirements for Sleeping Areas Rectangular housing models feature: itc( t\ ) ,q t • Appearance that complements TrueAlert strobes and p t\\\( I I i speaker/strobes V �� • Red or white housings with"FIRE"lettering for surface or semi-flush wall mount • Optional matching adapter skirts for covering surface mounted electrical boxes* • Optional red wire guard Round Speakers are Available in Off-White(no lettering) Round housing models feature: • Off-white color(no lettering)for flush mount on ceiling S•ecifications or wall • Compatible with optional tile bridge 2905-9946 Dimensions, Rectangular Wall Mount Housings Introduction Housing Dimensions (130 mm x 27 mmzx D38 mm) Simplex®4902 Series speakers provide high quality sound Depth into Box 2%"(70 mm) for emergency fire alarm use as well as for background Dimensions,Round Housings music.The moisture-repellent speaker is designed for Housing Dimensions 7'/"Diameter,'/"D smooth frequency response with minimal distortion. (191 mm x 13 mm) Depth into Box 2%4"(70 mm) The multi-tapped speaker transformer accommodates either 25 or 70.7 VRMS and provides an output of from%a General Specifications to 2 W to provide flexibility for satisfying the Input Voltage 25 or 70.7 VRMS requirements of the installed conditions. Power Taps '1/4,1/2, 1,and 2 W Rectangular housing models are for surface or semi-flush Input Terminal Ratings 18 to 12 AWG s wall mount applications.Round housing models are (0.82 mm to 3.31 mm ) typically for ceiling applications but can be wall mounted Frequency Fire Alarm 400 to 4000 Hz if desired.The rectangular housing speakers are designed Response General 125 to 12 kHz to compliment the TrueAlert family of strobes and Signaling speaker/strobes,providing conventional,non-addressable Sound Output See information on page 4 speaker operation. Temperature Range 32°to 100°F(0°to 38°C) • Refer to page 2 for guard and adapter skirt listing.This product has been approved by the Humidity Range 10%to 95%RH from 32°to California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health 122°F(0°to 50"C) and Safety Code.See CSFM Listing 7320-0026242 for allowable values and/or conditions concerning material presented in this document.Additional listings may be applicable, contact your local Simplex productsupplierfor the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. 34902-0003-7 5/2014 Product Selection Speakers 'Model` Description Dimensionsi 4902-9716(CA) Rectangular housing,wall mount Red with white"FIRE"lettering 5%"H x 5"W x 1 Y"D 4902-9717(CA) speaker White with red"FIRE"lettering (130 mm x 127 mm x 38 mm) Round housing speaker,ceiling or wall 7%"Diameter x'/"D 4902-97211(CA) mount Off-white(no lettering) (191 mm x 13 mm) ULC listed model are designated with a CA suffix(4902-9716CA). Refer to Installation Instructions 574-765 for non-suffix model numbers and to Installation Instructions 579-324 for CA suffix model numbers. Mounting Adapters Model Description I Dimensions 4905-9941 Red Use to cover surface mounted 5%"H x 5' "W x 3%s" D Surface mount adapter skirt; 1-1/2"deep box with 1A/2" (136 mm x 133 mm x 81 mm) 4905-9942 White (not ULC listed) deep extension external to Total surface depth with wall(see diagram on page 3) speaker=4%"(117 mm) 2905-9946 Tile bridge for 4902-9721 Speaker See diagram on page 3 4905-9931 Adapter Plate, red,for mounting to 2975-9145 box(typically for retrofit, 8 Y16"x 5 3/,"x 0.060"Thick may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red mounting box,requires Adapter Plate 4905-9931 7'/"x 5'/0'x 2%;'0 (200mm x 130mm x 70mm) Covers and Guard 'Model Description Dimensions''', 4905-9988 Red speaker cover with white"FIRE"lettering Interchangeable with 5 Y"H x 5"W x 1 %z"D 4905-9989 White speaker cover with red"FIRE"lettering TrueAlert horns (130 mm x 127 mm x 38 mm) Red wire guard with mounting plate;compatible with semi-flush or surface 6%s"H x 6%s"W x 3%"D 4905-9999 mounted boxes;for use with 4"square electrical box mounting hole (154 mm x 154 mm x 79 mm) patterns only(UL listed by Space Age Electronics Inc.) Wall Mount S.eakers, Installation Reference Mounting requires a 4"(102 mm)square ATh `� `� box,1-1/2"(38 mm)deep,with a 4"boxLj c T extension,1-1/2"deep,by others ('---); ) I o rJ Jr, n " / \.� (J rJ Speaker assembly ] • O _ r J � 2J • O a OIO ‘‘‘Wiring input terminals and speaker tap f A selection are accessible from rear of O it O speaker housing _ ✓C O/ wmmmom,e OrR _ Transparent speaker housing Removable cover -- --- -- (tool required) n 2 34902-0003-7 5/2014 Round Speaker Installation Reference (typically ceiling mount, can be wall mounted), 1 � 4"square,1-1/2"deep box .. with 1-1/2"extension(by others) Wring input terminals and speaker ✓ ---.°- � �� 7,7".......„,-_-_------___ tap selecton are accessible from _ a�g rear of speaker housing ✓ '��0� /? � r��''9'�1 ��r c =—~ /d II ll�� lll�� (,; ( tel. ,,� \ v , fill ilii) � effil -' \, r may' Front View 2905-9946 Tile Bride Dimensions 0.024"thick sheet 3-3/4"(95 mm)square metal,folded with cutout,centered on plate 1/2" lip each side 1/7 l.� _______________ (13 mm)_ o / 0 13-3/8.. I (340 mm) 'IN 1/4" (6 mm) holes,4 places 6-11/16" (170 mm) I23-11/16"(602 mm) I Surface Mounted Speaker Reference (Adapter Skirts are Not ULC listed) 4"(102 mm)square box, 1-1/2"(38 mm)deep with conduit shown for reference 4"(102 mm)square box extension, 1-1/2"(38 mm)deep ii I_ Optional 4905-9999 Wire Guard I I„I I lMI i 1 I' I.IRE 1 Speaker III assembly ill L _- Surface mount adapter skirt,3-3/16"deep: 4905-9941, Red;4905-9942,White Conduit knockouts are provided on all four sides Wall surface 3 S4902-0003-7 5/2014 S•eaker Sound Out•ut S•ecifications' Sound Output Ratings @ 10 ft(-3 m) per UL 1480 Reverberant Chamber Testing Selected Tap Model Type Input Voltage 1/4W ,1/4 W 1 W '.' 2 W 4902-9716 25 VRMS 80 dBA 83 dBA 85 dBA 88 dBA 4902-9717 Rectangular Housing 70.7 VRMS 79 dBA 82 dBA 85 dBA 88 dBA 4902-9721 Round Housing 25 or 70.7 VRMS 79 dBA 82 dBA 85 dBA 88 dBA Sound Output Ratings @ 3 m (-10 ft)per ULC 5541 Anechoic Chamber Testing Selected Tap Model Type Input Voltage (see note) (see note) '.. 4902-9716CA Rectangular Housing* 25 VRMS or 70.7 VRMS 77 dBA 80 dBA 83 dBA 86 dBA 4902-9717CA 4902-9721CA Round Housing* 25 VRMS or 70.7 VRMS 79 dBA 82 dBA 85 dBA 89 dBA *NOTE: ULC Fire Alarm applications require use of 1 W or 2 W tap for Round Housing speakers;and 2 W tap for Rectangular Housing speakers. Speaker Polar Dispersion Reference(per ULC S541 Anechoic Chamber Testing) Attenuation I'Angle -3 dB 30°off-axis -6 dB 55°off-axis 4905-9931 Ada•ter Plate Installation Reference 0 2975-9145 Box omen 4905-9931 Adapter Plate _ _-r•7 0 O 4905-99990pional —r"—"—"—"—�"-1 VMre Guard �I%..����������I1 t (shown here for reference only,can II�'I�I�hisiiii; 211 be used on other IA/ ' ' 0 0 mounting options) r_, II ■ `- O Flora I fOIAC 4905-9931 Adapter Plate O Speaker assembly TYCO,SIMPLEX,and the product names listed in this nutlet-tat are marks and/or registered marks.Unauthorized use is strictly prohibited.IOTA 72 and National Ihre Almon and SignalingCode are registered trademarks.of the National/ire Protection Association(PUPA). BSS i m per'EX Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4902-0003-7 5/2014 �J eA wwv✓simplex-fire.com C 2014 Tyco Fire Protection Products All rights reserved All speorjcotions and other In ornmtion showrnsere caret as of document revision date and are subject to change wllhout notice. asimplex TrueAlert Notification Appliances UL, CSFM Listed; FM, Speaker/Visible Notification Appliances with TrueAlert and MEA (NYC)Approved* Non-Addressable Strobe; Round, Ceiling Mount Features' g ►��"T Audible/visible ceiling mount notification appliance with: • Multi-tapped speake (InC..."• High intensity xenon strobe,selectable for free-run or synchron ized flash Audible notification appliance (speaker):• High quality voice and tone reproduction with taps for 1/4, 1/2, 1,or 2 W, at 25 or 70.7 VRMS • Speakers are wired separately from strobe wiring • UL listed to Standard 1480 • Compliant with NFPA 72,520 Hz Low Frequency Signal Requirements for Sleeping Areas Ceiling Mount TrueAlert Non Addressable SN Appliances Feature White Housings with Red Lettering TrueAlert non-addressable visible notification appliance(strobe): • Models available with 15,30,or 110 candela • 24 VDC operation with switch selection for free-run Strobe Selection or synchronized flash rate** Proper selection of visible notification is dependent on • UL listed to Standard 1971 occupancy,location,local codes,and proper applications • Compatible with ADA requirements of: the National Fire Alarm Code (NFPA 72),ANSI • Strobe candela rating is clearly indicated on reflector A117.1;the appropriate model building code:BOCA, ICBO,or SBCCI;and the application guidelines of the • Rugged,high impact,flame retardant thermoplastic Americans with Disabilities Act(ADA). housing Synchronized flash rate mode for use with: Strobe O'erationi • Synchronization modules for Class B (Style Y)or TrueAlert non-addressable SN strobes can be set Class A(Style Z)operation for free-run operation or synchronized operation using an on-board selection switch. When selected for synchronized Notification appliance design provides: operation,flash operation is controlled from: • Round housing for ceiling mount in standard • Simplex®Fire Alarm Control Panels providing NACs electrical boxes selected to product Simplex strobe synchronization • Separate in/out wiring terminals for speaker and signals(refer to control panel data sheet for details) strobe • Synchronized Flash Modules,4905-9914(Class B) or 4905-9922(Class A) DescrI'non • 4009 IDNet NAC Extender,models 4009-9201 and 4009-9301 (refer to data sheet S4009-0002) TrueAlert non-addressable speaker/visible(SN) notification appliances combine a multi-tapped speaker and a high intensity strobe to provide audio/tone notification and visible notification from the same appliance. * This product has been approved by the California State Fire Marshal(CSFM)pursuant to Speakers and strobes are wired separately.The speaker is Section 13144.1 of the California Health and Safety Code,See CSFM Listing multi-tapped with taps available for either 25 VRMS or 7320-0026:242 for allowable values and/or conditions concerning material presented In this document.Accepted for use—City of New York Department of Buildings—MEA35-93E. 70.7 VRMS and the strobe is selectable for either free-run This product was not ULC Bated as of document revision date.Additional istings may be or synchronized operation. applicable;contact your local Simplex product supplier for the latest status,Listings and approvals under Simplex Time Recorder Co,are the property of Tyco Fire Protection Products. 84903-0019-5 5/2014 Product Selection SpeakerNisible Round Ceiling Mount Notification Appliances with TrueAlert Non-Addressable Strobes Strobe Output Rating Model Housing Color 15cd 30cd 110cd 4903-9196: ✓ 4903-9197 ✓ White with red "FIRE"lettering 4903-9198 ✓ Synchronized Flash Control Modules Model Description Dimensions 4905-9914 Synchronized Flash Module, Epoxy encapsulated with in/out Class B(Style Y)operation 18 AWG (0.82 mm2)wire leads, 1-3/8"W x 2-7/16" L x 13/16"H 4905-9922 Synchronized Flash Module, rated for 2 A NAC, requires (35 mm x 62 mm x 20 mm) Class A(Style Z)operation 5 mA for power Accessories Model Description Dimensions 2905-9946 Tile Bridge See diagram on page 4 Installation Reference 4"(102 mm)square, 1-1/2"(38 mm)deep box with 1-1/2"extension(by others) ooh® ) o 0 0 I ®® 0 �♦ a. Wiring < input terminals and - speaker tap selection are1 1/43 , accessible from rear of speaker housing I I r is ,,,,,„,.. , .,_. , , , I I Selection switch for free-run or to I, synchronized flash is behind strobe N +I assembly;determine operation II before inserting into housing i` 2 84903-0019-5 5/2014 SN S•ecifications Strobe Specifications UL Listed Range Regulated 24 VDC; see Notes 1 below Rated Voltage Range ULC Listed Range 20 VDC to 30 VDC per ULC 5526-M87 Flash Rate and Synchronized NAC Loading 1 Hz;with up to 35 synchronized strobes maximum per NAC Maximum RMS Current Rating per Strobe 15 cd 30 cd 110.cd Output(see Note 2 below) 90 mA 128 mA 285 mA Reference Currents 18 VDC 80 mA 114 mA 253.mA at other voltages 24.VDC 60 mA : 85 mA 190 mA Speaker Specifications Input Voltage 25 or 70.7 VRMS,see Note 3 below Power Taps 1/4, 1/2, 1, and 2 W Fire Alarm Frequency Response 400 to 4000 Hz Speaker Output Wattage Tap 1/4 W 1/2 W '.. 1 W 2.W Ratings(dBA) UL 1480 Reverberant 79 82 85 88 @ 10 ft(3 m) Chamber Rating General Specifications Housing Dimensions(including lens) 7-1/4" H x 5"Wx 2-5/8" D(184 mm x 127 mm x 67 mm) Depth into Box 2-1/4" (57 mm) Speaker Tap Selection Single jumper wire with pressure connector, attaches to one of 8 terminals Temperature Range 32°to 122° F (0°to 50° C) Humidity Range 10%to 93%, non-condensing at 100° F(38°C) Connections Terminals for 18 to 12 AWG(0.82 mm2 to 3.31 mm2),separate terminals for speaker and strobe connections Installation Instructions 579-326 NOTES: 1. "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions.The strobe of this NV is field selectable for free-run or synchronized operation. 2. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) 3. Speakers are for connection to conventional fire alarm audio circuits. 3 S4903-0019-5 5/2014 2905-9946 Tile Bride 0.024"thick sheet 3-3/4" (95 mm)square metal,folded with cutout,centered on plateY11- 1/2" lip each side 0 1/2" (13 mm)' 13-3/8" ) '1\1/4" (340 mm 1/4"diameter(6 mm) o holes,4 places 6-11/16" (170 mm) 1 . 23-11/16" (602 mm) YYCO,9MPLh'X and the product names listed in this material are'narks and'or registered narks.Unauthorized use is strictly prohibited.NFPA 72 and National l%n e Alarm and Signaling Code are registered mademarkv of the National Fire Protection Asroeiaso17(NFPA). B S irn n'ex Tyco Fire Protection Products•Westminster, MA•01441-0001•USA 54903-0019-5 5/2014 Y www.simplex-fire.com ©1014 Tyco Fire Protection Products All nghrs resenwd All specifications and other information shown were current as ofdocrm,enrrermon date and are subject to change without nonce.