Loading...
HomeMy WebLinkAboutNORTHSIDE DATA SHEETS.pdfThe VISTA-128BPE is a powerful member of the Honeywell family of commercial alarm panels, integrating burglary, CCTV and access control functions. Many features are available that extend the applications of the VISTA-128BP while simplifying end-user operation. The VISTA-128BP and VISTA-128BPE (VISTA-128BP Rev. 4) are Listed for residential burglary, residential fire and commercial burglary applications (see agency listings in this document for more details). They are compatible with a wide range of AlarmNet communications products for alarm reporting, uploading/downloading and remote services. Standard features (VISTA-128BP and VISTA-128BPE): • Provides nine style-B hardwired zones • Supports up to 119 additional zones using a built-in polling (V-Plex, multiplex) loop interface • Supports up to 127 wireless zones using up to two 5800 series wireless receivers (fewer if using hardwire and/or polling loop zones) • Provides one power-limited bell circuit delivering 1.7Amp (max) at 12Vdc • Provides the ability to control eight separate partitions independently, each functioning as if it had its own separate control • Accommodates 150 user codes with seven authority levels • Accommodates 32 keypad macro commands per system • Keeps a log of up to 512 events • VistaView-100 CCTV support • Supports up to 16 compatible two- wire smoke detectors on zone 1 • Supports up to 50 latching-type glassbreak detectors on zone 8 • Zone 7 may be used for keyswitch arming/disarming • Supports V-Plex®addressable VistaKey access control (up to eight doors and 250 cards) • Easily programmed and maintained by Compass Windows-based downloader • Supports up to 96 programmable outputs • Programmable to meet SIA false alarm prevention specifications. To meet UL approval for ANSI/SIA CP-01-2000 order part number VISTA-128SIA • Panel Linking up to eight panels • Supports eight numeric pager numbers • Supports touchscreen Advanced User Interface (AUI) • Smoke detector reset at keypad • Quick exit • Group bypass • Arm faulted • Event arming • Scheduled check-in • Arm stay by group Enhanced features (VISTA-128BPE only): • Carbon monoxide (CO) zone type support • Expanded RS-232 capability for third party interface and automation • Internet upload/download over AlarmNet GSM, iGSM and IP communicators over the panel's keypad (ECP) bus • Ringback support for AlarmNet communicators (confirmation of closing report) • 24-hour dialer test support for AlarmNet devices FEATURES VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS Basic Hardwired Zones Provides nine style-B hardwired zones with the following characteristics: • EOLR supervision (optional for zones 2-8) supporting N.O. or N.C. sensors (EOLR supervision required for fire and UL burglary installations) • Individually assignable to one of eight partitions Polling Loop Expansion Supports up to 119 additional zones using a built-in polling (V-Plex, multiplex) loop interface. Current draw can total up to 128mA. Polling loop zones have the following characteristics: • Must use V-Plex devices • Supervised by control panel • Individually assignable to one of eight partitions Wireless Expansion Supports up to 127 wireless zones using up to two 5800 series wireless receivers (fewer if using hardwire and/or polling loop zones). Wireless zones have the following characteristics: • Supervised by control panel for check-in signals (except certain non-supervised transmitters) • Tamper protection for supervised transmitters • Individually assignable to one of eight partitions Scheduling Provides the following scheduling capabilities: • Open/close schedules (for control of arming/disarming and reporting) • Holiday schedules (allows different time windows for open/close schedules) • Timed events (for activation of relays, auto-bypassing and unbypassing, auto-arming and disarming, etc.) • Access schedules (for limiting system access to users by time) • End user output programming mode (provides 20 timers for output control) Eight Partitions Provides the ability to control eight separate areas independently, each functioning as if it had its own separate control. Partitioning features include: • A Common Lobby partition (1-8), which can be programmed to arm automatically when the last partition that shares the common lobby is armed, and to disarm when the first partition that shares the common lobby is disarmed • A Master partition (9), used strictly to assign keypads for the purpose of viewing the status of all eight partitions at the same time (master keypads) • All zones assignable to one of eight partitions • Keypads assignable to one of eight partitions or to Master partition 9 to view system status • Ability to assign relays to one or all eight partitions • Ability to display fire and/or burglary and panic and/or trouble conditions at all other partitions’ keypads (selectable option) • Individually programmable account number, entry delay and exit delay by partition ADDITIONAL FEATURES 4293SN Adapters VISTA-128BP 4101SN Relay Module FG1625SN Glassbreak 4208U Eight-zone Expansion Module and 4208EX Eight-zone V-Plex Expander 710Light 748Horn 5881 Wireless Receiver 6160 Console 4204RelayModule Phone Line to Central Station GSM iGSM or Notification Appliances Keyswitch Option 4146 5193 Series Smoke Detectors V-Plex Loop Alpha PagingModule Parallel Printer Serial Printer RS-232 DT7500SN V-Plex DUAL TEC Motion Sensor NOTE: Please refer to the website (www.honeywell.com/security/hsc) for the latest product information. 7847i ECP Bus or VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS 6160 Console Glassbreak Detectors 4944SN Contact 5881ENHC Commercial Wireless Receiver (Max Two) 4204RelayModule 4204CF Supervised NAC Module Supports Up To 16 Conventional Two-WireSmoke Detectors 4209U Group Zoning Module 4190SN Remote Point Module4193SN Serial Interface Module 4959SN Overhead Door ContactIS2500SN V-Plex PIR Motion Sensor 4208U Eight-zone Expansion Module Panel Linking Module Panel Linking Module VISTA-128BP ECP Bus 5808W3WirelessSmokeDetector 5890Wireless PIR5816 Door/Window Transmitter VISTA-128BP 5800 Series Wireless Devices VISTAKey V-Plex Access Control Module 5817CB Universal Contact Monitoring Transmitter 5869 Commercial UL Wireless Hold-up Button Auxiliary Devices • 4204 - Relay Module, four form C contacts • 5881 Series - RF Receiver supporting 5800 wireless detectors • 6160 - Alpha Keypad/Annunciator • 6220S - System Printer used with 4100SM serial module • VA8200 - (PLM) Panel Linking Module • VA8201 - (APM) Alpha Paging Module Manual Pull Stations • 5140MPS-1 • 5140MPS-2 V-Plex (addressable) Devices • 4101SN Single Relay/zone Module • 4190SN Remote Point Module - two zones • 4193SN Two zone Serial Interface Module • 4208EX - Eight zone expander for ULC commercial installations • 4208U Loop Expansion Module - eight zones • 4209U Group zoning Module - two/four zones • 4293SN One zone Serial Interface Module • 4297 Isolation/Extender Module V-Plex (addressable) smoke detectors • VSI Short/Overload Isolation Module • 5193SD • 5193SDT Passive Infrared Detectors • 998MX • IS2500SN • DT7500SN • QUEST2260SN V-Plex (Addressable) Contacts • 4939SN-WH • 4944SN-WH • 4959SN, 9500SN V-Plex Glassbreak Detectors • FG1625SN VISTA Interactive Phone Module • 4286 VIP Module Optional Communicators • AlarmNet Internet/Intranet communicators and digital cellular communicators Access Control • VISTAKey V-Plex (addressable) Access Control • VISTAKey-SK Starter Kit • VISTAKey-EX Expansion Kit CCTV • Optiflex CCTV module Wireless Devices • 5804 - Wireless Key • 5804BD - Bidirectional Key • 5804BDV - Bidirectional with voice • 5816 - Door/Window Transmitter • 5819 - Shock Sensor • 5827BD - Bidirectional Keypad • 5853 - Glassbreak Detector • 5894 - Wireless PIR Motion Sensor • 5890 - Passive Infrared Detection • 5800PIR-OD - Outdoor Motion Sensor • 5870API - Asset Protection Device • 5800PIR/5800PIR-RES/5800PIR- COM—Wireless Motion Detectors • 5800CO/A - Wireless Carbon Monoxide Detector • 5800RP - Wireless Repeater • 5808W3 - Wireless Smoke Detector • 5809 - Wireless Heat Detector Commercial Listed Wireless Devices • 5817CB - Commercial UL Burglary, Universal Contact Monitoring Transmitter* • 5869 - Commercial UL Wireless Hold-up Button* • 5881ENHC and 5883H Receivers *When used with 5881ENHC and/or 5883H receiver. ACCESSORIES ORDERING VISTA-128BP Commercial Burglary Alarm Control Panel (UL Listed) VISTA-128BPE Enhanced Commercial Burglary Alarm Control Panel (ETL Listed as VISTA-128BP Rev. 4, UL Pending) VISTA-128SIAE SIA Approved Enhanced Commercial Burglary Alarm Control Panel L/VSTA128BPD/D April 2010 © 2010 Honeywell International Inc. For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 1.800.467.5875 www.honeywell.com VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS Agency Listed to the Following Standards: • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault • UL611/UL1610 Grades A, AA Central Station • UL365 Grades A, AA Police Connect • UL985 Household Fire • UL1023 Household Burglar Alarm California State Fire Marshall (CSFM) • UL1635 - Digital Alarm Communicator System Units • CAN/ULC - S303 • CAN/ULC - S304 • CAN/ULC - S545 • CAN/ULC - S1023 • For commercial burglary attack proof requirements, use VISTA-ULKT attack proof enclosure Electrical • Voltage Input: From Honeywell No. 1361 Plug-In Transformer or 1361X10 transformer (for X-10 installations) rated 16.5VAC, 40 VA • Use 1361CN plug-in transformer for Canada • Alarm Sounder Output: 10VDC- 13.8VDC, 1.7 amps max., (UL1023, UL609 installations); 750mA less aux. current draw (UL985 installations) • Auxiliary Power Output: 9.6VDC- 13.8VDC, 750mA max. For UL installations, the accessories connected to the output must be UL Listed, and rated to operate in the above voltage range • Backup Battery: 12VDC, 4AH or 7AH sealed-lead acid. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH) recommended • Standby Time: Four hours min. with 750mA aux. load using 7AH battery • Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts). A solid state circuit breaker is used on auxiliary power output to protect against wiring faults (shorts). Main Dialer • Formats Supported: ADEMCO Contact ID, ADEMCO High Speed, ADEMCO 4 + 2 Express, ADEMCO Low Speed, Sescoa and Radionics Low Speed • Line Seize: Double Pole • Ringer Equivalence: 0.7B Cabinet Dimensions 12-1/2" W X 14 1/2" H X 3" D SPECIFICATIONS Control Unit Accessories, System Backup dialer modules, Model(s) 5140DLM Eight-zone remote point Class A interface modules, Model(s) 4208SNF Eight-zone remote point modules, Model(s) 4208SN, 4208U Enclosures, Model(s) 5800BOX End-of-line resistors, Model(s) 4100EOLR, EOL100, EOL20, EOL22, EOL82, EOLR470K Fire system annunciator keyswitch modules, Model(s) FSAKSM (d) Fire system annunciator modules, Model(s) FSA-24F, FSA-8F Internet and Digital Cellular Fire Communicator, Model(s) iPGSM-COM, IPGSM-DP Internet communicators, Model(s) 7845i-ent, 7845i-entF (c) Isolation modules, Model(s) ECP-Isolator, VPLEX-VSI Keyswitches, Model(s) 4146 (a) LCD keypads, Model(s) 6160CR-2, FA570CR Polling loop extender modules, Model(s) 4297 RF receivers, Model(s) 5881ENHC RF transceiver subassemblies, Model(s) 5883H Sensor Interface Module Gateway, Model(s) 472368 Supervised notification appliance modules, Model(s) 4204CF Transformers, Model(s) 1451 Universal group zoning multiplex modules, Model(s) 4209U Wireless transmitters, Model(s) 5817CB Zone expander modules, Model(s) 4190SN, 4193SN (b), 4193SNP (b) (a) - Must be installed adjacent to an alphanumeric (English language) keypad, Model 6160CR-2 when used as a fire alarm silencing switch. (b) - Must be mounted inside control panel cabinet or within a Listed junction box. Supervised Zone is required for Fire. Unsupervised Zone may be UOXX.S789 Control Unit Accessories, System Page Bottom See General Information for Control Unit Accessories, System HONEYWELL SECURITY S789 SUITE 100 2 CORPORATE CENTER DR PO BOX 9040 MELVILLE, NY 11747 USA Page 1 of 2UOXX.S789 - Control Unit Accessories, System 8/30/2011http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=U... used for Burglary. (c) - For use with Model FOCUS 200 PLUS control unit. (d) - Keyswitch module must be installed adjacent to FSA unit if remote silence/reset desired. NOTE - Model numbers may include a prefix or suffix consisting of numbers and/or letters. For use with compatible Listed control unit systems as indicated in the installation instructions. Copyright © 2011 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2011 Underwriters Laboratories Inc.®" Last Updated on 2011-07-18 Questions? Print this page Notice of Disclaimer Page Top Page 2 of 2UOXX.S789 - Control Unit Accessories, System 8/30/2011http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=U... DF-52013:C1 • 8/16/10 — Page 1 of 2 BG-12LX Addressable Manual Pull Station Addressable Devices DF-52013:C1 • E-100 FLPullStation.jpgGeneral The Fire·Lite BG-12LX is a state-of-the-art, dual-action (i.e.,requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire·Lite’s addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word “ACTIVATED” appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm² wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide-lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonatematerial with a textured finish. Specifications •Shipping Weight: 9.6 oz. (272.15 g) •Normal operating voltage: 24 VDC. •Maximum SLC loop voltage: 28.0 VDC. •Maximum SLC loop current: 230 μA. •Temperature Range: 32°F to 120°F (0°C to 49°C) •Relative Humidity: 10% to 93% (noncondensing) •For use indoors in a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4" (10.16 cm) square electrical outlet box, orwill surface mount to the model SB-10 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word “ACTI- VATED” (in bright yellow) appears at the top of the handle,while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 – 159 with Breakaway Tab removed for MS-9600 Series, 1 – 99 and MS-9200UDLS, 1 – 50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shallappear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flushmounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within Page 2 of 2 — DF-52013:C1 • 8/16/10 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105.www.firelite.com FIre·LIte is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. Made in the U.S. A. the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provideaddress setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. •UL Listed: S711 •MEA: 67-02-E •CSFM: 7150-0075:0184 •FDNY: •FM Approved Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Agency Listings 5600 Series Mechanical Heat Detectors System Sensor’s 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Features Multiple configurations for installations: – Single- and dual-circuit models – Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. Plain housing for residential installations (Model 5601P) Easy-to-use terminal screws A broad range of back box mounting options: – Single gang – 3.5˝ and 4˝ Octagonal – 4˝ square with square to round plaster ring Reversible mounting bracket • • • • • Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit models are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back boxes. And these models accommodate four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. S2101 3016008 199-03-E 7270-1209:227 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2006 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0351-002 • 11/06 • #1676 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number _________, listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 3½-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14–22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601P, 5602, 5621, and 5622 only) Mounting 3½-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact Ratings 6–125VAC / 3A 6–28VDC / 1A 125VDC / 0.3A 250VDC / 0.1A Input Terminals 14–22 AWG Ordering Information Model Circuit Identification Method on Exterior Temperature Rating Activation UL Protected Spacing – 10 Foot Ceiling* 5601P Single None 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5602 Single Lettering 194°F (90°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5603 Single Lettering 135°F (57°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5604 Single Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5621 Dual Lettering 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5624 Dual Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 5601P FX/ROR194°F/9 0 °C5602, 5622 FX135°F/5 7 °C5603, 5623 FX194°F/90 °C 5604, 5624 FX/ROR135°F/5 7 °C5621 Honeywell’s 5193SD/SDT Addressable Photoelectric Smoke Detector is designed to provide open area protection and to be used with compatible UL-listed Honeywell control panels that support V-Plex technology. The detector incorporates a state-of-the-art optical sensing chamber and an advanced microprocessor. Built-in Drift Compensation algorithms automatically maintain proper operation at factory calibrated detection levels, even when sensitivity is altered due to the presence of contaminates settling into the unit’s chamber. The 5193SDT also features a restorable, built-in, fixed temperature (135° F/57.2° C) thermal detector. • Easy Installation:Installation of the 5193SD/SDT detector is simplified by the use of a mounting base that may be pre-wired to the system, allowing the detector to be easily installed or removed for maintenance or service. (See Figure 1). • LED Status Indicators:Two LEDs (green and red) provide local visual indication of the detector’s status – including normal operation, alarm, out of sensitivity and trouble conditions. • Test button:This button allows the user to perform periodic testing of the detector’s circuitry and verify that the detector is within the sensitivity limits. • Versatile Mounting:Mounting is made simple with the included hardware and the large mounting ports, which accommodate drywall anchors for easy surface mounting. (See Figure 1). • Tamper Protection and Tamper Resistance:The detector contains a built-in tamper switch that can communicate back to the control panel in the event the detector is removed from its base. For an added level of security, the detector also includes a tamper resistant element that prevents removal from the base without the use of tools. (See Figure 1). FEATURES 5193SD/5193SDT V-PLEX®ADDRESSABLE SMOKE DETECTOR Figure 1: Tamper-Resistant Feature/Wiring SNAP OFF TAB FOR TAMPER LOCK TAMPER RELEASE TAB DIRECT MOUNT HOLES L/5193SDT/D May 2009 © 2009 Honeywell International Inc. Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com ORDERING 5193SD Addressable Photoelectric Smoke Detector 5193SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor Accessory sold separately: SENS-RDR Handheld Sensitivity Reader SPECIFICATIONS 5193SD/5193SDT V-PLEX®ADDRESSABLE SMOKE DETECTOR • Heat Sensor:(Model 5193SDT): 135° F (57.2° C); Fixed Temperature Electronic Thermistors • Operating Ambient Temperature Range: 32° to 100° F (0° to 38° C) • Operating Humidity Range: 0 to 95% RH non-condensing • Storage Temperature Range: -4° to 158° F (-20° to 70°C) • Diameter (including base):5.3 inches • Height (including base):2.0 inches • Weight:6.3 oz. • Agency Listing:UL-268 • System Voltage Range:7-14V • Standby Current (maximum @ 12V) LED off: 1.2mA LED on: 2.8mA To measure the detector’s sensitivity, the SENS-RDR Infrared Sensitivity Reader tool (sold separately) should be used. It reduces testing time, simplifies sensitivity measurements and displays them precisely in terms of percent per foot obscuration. The SENS-RDR eliminates the need for magnets, voltmeters and ladders. ACCESSORY (sold separately) Figure 2: Position of Reader OR Agency Listings Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Field-selectable candela settings on ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and three volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert devices • Compatible with MDL sync module • Listed for ceiling or wall mounting The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications SpectrAlert® Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. MEA452-05-E3023572 7125-1653:186 (indoor strobes) 7125-1653:188 (horn strobes, chime strobes) 7135-1653:189 (horns, chimes) S4011 (chimes, horn strobes, horns)S5512 (strobes) AVDS00501 SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8˝ diameter × 2.5˝ high (173 mm diameter × 64 mm high) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2)7.1˝ diameter × 2.2˝ high (180 mm diameter × 57 mm high) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS, TRCW-HS) 6.9˝ diameter × 0.35˝ high (175 mm diameter × 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS00501 Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7†Coded High 82 82 88 88 93 92 101 101 8†Coded Medium 78 78 85 85 90 90 97 98 9†Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobes. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 UL Current Draw Data Horn Strobe Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.AVDS00501 • 3/12 SpectrAlert Advance Dimensions Model Description Ceiling Horn Strobes PC2R*2-Wire Horn Strobe, Standard cd, Red PC2RH 2-Wire Horn Strobe, High cd, Red PC2W*†2-Wire Horn Strobe, Standard cd, White PC2WH*2-Wire Horn Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red PC4RH 4-Wire Horn Strobe, High cd, Red PC4W 4-Wire Horn Strobe, Standard cd, White SpectrAlert Advance Ordering Information Notes: * Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., P2R-P. † Add “-SP” to model number for “FUEGO” marking on cover, e.g., P2R-SP. ‡ “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. 4.7˝ 5.6˝ 6.8˝Dia. 2.5˝ 2.5˝2.23˝5.05˝ 5.98˝ 7.1˝Dia. 2.25˝ 5.1˝ 2.0˝ 5.7˝ 7.1˝Dia. 2.0˝ Ceiling-mount horn strobes Ceiling back box skirt Model Description Ceiling Strobes SCR Strobe, Standard cd, Red SCRH Strobe, High cd, Red SCW*Strobe, Standard cd, White SCWH Strobe, High cd, White Accessories BBSC-2 Back Box Skirt, Ceiling, Red Back Box Skirt, Ceiling, White TRC-HS Trim Ring, Ceiling, Red TRCW- HS Trim Ring, Ceiling, White