Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B17-0237 Permit Documents.pdf
•r CERTIFICATE OF COMPLIANCE Certificate Number 20130517-R684E Report Reference R684, April27, 1971 Issue Date 20 13-May-17 Issued to: CERTAINTEED CORP 1400 Union Meeting Rd PO Box 1100 Blue Bell, PA 19422 This is to certify that Prepared Roof Covering Materials representative samples of Class A Fire Resistant, Asphalt Glass Fiber Mat Shingles, designated; Landmark TL, Presidential Shake TL, Presidential Solaris or Presidential Shake. Standard(s) for Safety: Additional Information: Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. ANSI/UL 790/ASTM El08, Tests for Fire Resistance of Roof Covering Materials; ASTM D3161 , Wind Resistance of Prepared Roof Covering Materials; ASTM D3462, Asphalt Shingles made from Glass Felt and Surfaced with Mineral Granules; ASTM D30 18, Class A Asphalt Shingles Surfaced with Mineral Granules. See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Listing Mark should be considered as being covered by UL's Listing and Follow-Up Service. The UL Listing Mark generally includes the following elements: the symbol UL in a circle: ®with the word "LISTED"; a control number (may be alphanumeric) assigned by UL; and the product category name (product identifier) as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product. SEE ADDENDUM PAGE 2 JJ~tf~ Wlllt.m R. Carney, Director, North Amertean Certiflc.tlon Program• ULLLC Any lnfonnation and doc.umentaUon Involving UL Martt MrvkM are provk:ted on behatf of UL LLC (Ul) or any autnortzed llcen ... of UL For queetlont:, pktne contact 1 local Ul Cuatomer S.rvka Representettve at www.ul.com/contfctus Page 1 of 2 CERTIFICATE OF COMPLIANCE Certificate Number Report Reference Issue Date 20130517 -R684E R684, April 27, 1971 20 13-May-17 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. These products are manufactured by Certain Teed. These shingles are composed of a glass fiber mat impregnated and coated with asphalt, surfaced with mineral granules. William R. Carney, Director, North American Certification Programs ULLLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local Ul Customer Service Representative at www u! corn!contactya Page 2 of 2 HOME I RESIDENIIAL ROOFING I PRODUCfS I PRESIDENTIALSHAKE®TL PRESIDENTIAL SHAKE® TL PRESI DENTIAL SHAKE® TL Triple Laminate Presidential Shake TL, the luxury shingles with the look of cedar shakes and the performance of one of the finest composition roofing solutions in the industry. • Three layers of material for the industry's thickest, toughest and heaviest shingle • The sculpted tabs provide the look and beauty of old world wood shake but with better performance and at a fraction of the cost • Unique, rich rustic colors available to suite all tastes PRODUCT OVERVIEW -Presidential Shake Series Brochure-Northwest -Presidential Shake Series Brochure -Southwest Region -Special Effects Brochure -StreakFighter Algae-Resistant Shingles Brochure (More Info) TECHNICAL SPECS -Presidential Shake TL UL USA Compliance -Presidential Shake TL UL Canada Compliance -3-Part Spec-Presidential Shake TLAR -Data Sheet -Presidential Shake Series (More Info) INSTALLATION -Presidential Shake TL Installation Instructions (More Info) WARRANTY -Asphalt Shingle Limited Warranty -Sure Start Warranty Brochure (More Info) OVERVIEW TECHNICAL INFO GET INSPIRED AND LEARN MORE ARTICLES VISIT THE RESIDENTIAL ROOFING LEARNING CENTER VISIT THE RESIDENTIAL ROOFING INSPIRATION GALLERY WHAT ARE ARCHITECTIJRAL ROOFING SHINGLES? TECHNICAL INFORMATION • Three-piece laminated fiber glass construction • 480 lbs. per square • UL Class A fire resistance rating • UL certified to meet ASTM D3462 • UL certified to meet ASTM D3018 Type I • ASTM D3161, Class F, no mpl wind resistance • Conforms to CSA standard A123.5 OVERVIEW TECHNICAL INFO • Miami-Dade Product Control Acceptance: Please see the Notice of Acceptance (NOA) to determine approved products by manufacturing location. SPECS -Presidential Shake TL UL USA Compliance -Presidential Shake TL UL Canada Compliance -3-Part Spec-Presidential Shake TLAR -Data Sheet -Presidential Shake Series -3-Part Spec-Presidential Shake TL -Miami-Dade NOA -Presidential Shake TL -SDS -Asphalt Shingle -AR -SDS -Asphalt Shingle -non-AR -ICC-ES ESR-3537 -ICC-ES-ESR-1389 -FL-5444 -Asphalt Roofing Shingles OVERVIEW TECHNICAL INFO INSTALLATION Applying a roof system correctly is essential to the warranty and performance of the roof. Please refer to the installation instructions for complete details. Available in both English and Spanish. INSTALLATION -Presidential Shake TL Installation Instructions WARRANTY DETAILS CertainTeed warrants that its shingles will be free from manufacturing defects, and provides the extra assurance of SureStart TM protection. Below are highlights of the warranty for Presidential Shake® TL. See CertainTeed's Asphalt Shingle Products Limited Warranty document for specific warranty details regarding this product. • Lifetime, limited transferable warranty • 10-year SureStart TM warranty that covers 100% of replacement and labor costs due to manufacturing defects • Is-year StreakFighter® warranty against streaking and discoloration caused by airborne algae • Is-year, 110 mph wind-resistance warranty • Wind warranty upgrade is available up to I30 mph. Specified Certain Teed starter and Certain Teed hip and ridge are required. WARRANTY -Asphalt Shingle Limited Warranty -SureStart Warranty Brochure EXPORT INFORMATION Presidential Shake® TL asphalt roofing shingles are available for Export. Please OVERVIEW TECHNICAL INFO INS1 review the related Export documents for additional information. EXPORT LINKS -Export Roofing Selection Guide -International Limited Product Warranty -Declaration of Performance Documents SYNTHETIC GUARD~ SYNTHETIC UNDERLAYMENT APPLICATION INSTRUCTIONS THESE ARE THE APPLICATION INSTRUCTIONS FOR TAMKO SYNTHETIC GUARD UNDERLAYMENT. TAMKO BUILDING PRODUCTS, INC. SHALL NOT BE RESPONSIBLE FOR LEAKS OR OTHER ROOANG PROBLEMS RESULTING FROM IMPROPER APPLICATION. FAILURE TO PROPERLY APPLY THIS PRODUCT ACCORDING TO THESE INSTRUCTIONS COULD RESULT IN UNSAFE CONDITIONS AND COULD ADVERSELY AFFECT COVERAGE OF THE LIMITED WARRANTY. CHECK LOCAL BUILDING CODES TO DETERMINE SUITABILITY OF THIS PRODUCT FOR YOUR INTENDED USE. TO OBTAIN A COPY OF TAMKO'S LIMITED WARRANTY, VISIT US ONLINE AT TAMKO.COM OR CALL US AT 800-641-4691. UNDERLAYMENT PRODUCTS BEGIN TO AGE AS SOON AS THEY ARE EXPOSED TO NATURE. BUILDINGS EXPERIENCE AGING FACTORS DIFFERENTLY, SO IT IS DIFFICULT TO PREDICT HOW LONG A PRODUCT WILL LAST. THAT'S WHY TAMKO PROVIDES A LIMITED WARRANTY ON SYNTHETIC GUARD THAT INCLUDES A BINDING ARBITRATION CLAUSE AND OTHER TERMS AND CONDITIONS WHICH ARE INCORPORATED HEREIN BY REFERENCE. YOU MAY OBTAIN A COPY OF THE LIMITED WARRANTY AT TAMKO.COM OR BY CALLING 1-800-641-4691. IMPORTANT: THIS PRODUCT MAY BECOME SLIPPERY DURING ROOF APPLICATION. FALL PROTECTION METHODS MUST BE USED WHEN WORKING ON ROOFS. Check local building codes to determine suitability of this product for your intended use. IMPORTANT: This product does not serve as a substitute for following all proper fall protection procedures in accordance with OSHA regulatory requirements-including the use of personal fall protection devices when working on a roof. Applicator safety is of utmost importance. SDS INFORMATION AVAILABLE ONLINE AT TAMKO.COM OR BY CALLING TAMKO'S TECHNICAL SERVICES DEPARTMENT AT 1-800-641-4691. SAFETY PRECAUTION Personal fall protection devices, safety glasses and hearing protection should always be used when applying TAMKO SYNTHETIC GUARD UNDERLAYMENT. Moisture, frost or debris may decrease the traction while walking on TAMKO SYNTHETIC GUARD UNDERLAYMENT. PLEASE EXERCISE CAUTION DURING INSTALLATION. USES TAMKO SYNTHETIC GUARD UNDERLAYMENT is intended to perform the functions of an underlayment when installed between the roof deck and the shingles or other final roof covering. TAMKO SYNTHETIC GUARD UNDERLAYMENT will not prevent wind driven rain from entering the building nor should it be used as the primary roof covering. The final roof covering must be installed before the structure is exposed to adverse weather conditions, such as wind driven rain, high wind, hail, ice storms, etc. Failure to apply TAMKO SYNTHETIC GUARD UNDERLAYMENT properly and according to TAMKO's Application Instructions could adversely affect coverage under the applicable Limited Warranty. TAMKO SYNTHETIC GUARD UNDERLAYMENT must not be exposed to UV rays for more than 180 days. SURFACE PREPARATION Apply TAMKO SYNTHETIC GUARD UNDERLAYMENT when the deck is dry. To begin, remove any dust, dirt, loose nails or other protrusions from the deck of new roofs. Remove all shingles, roofing felt, nails, or other existing roofing materials and debris from the deck of existing roofs. Before walking on the underlayment surface, the TAMKO SYNTHETIC GUARD UNDERLAYMENT must be securely fastened to the roof deck using corrosion-resistant nails as instructed in the Fastening section below. DO NOT USE STAPLES. Fall protection devices must be utilized. Moisture. frost or debris may decrease the traction while walking on TAMKO SYNTHETIC GUARD UNPERLAYMENT. FOR ROOF DECKS Apply TAMKO SYNTHETIC GUARD UNDERLAYMENT from low to high in shingle fashion so that laps will shed water. Overlap edge seams 4 in. as marked on the underlayment. For all applications, end seams must be overlapped 6 in. WARNING: <V APPROPRIATE FALL PROTECTION MElliODS SHOULD BE USED WHENEVER WORKING ON ROOFS. PRODUCT MAY BE SUPPERY. and staggered. Fasteners should be placed in all marked locations but no farther than 12 in. from end laps in the field of the roof. The underlayment must be laid out flat with printed side up without wrinkles and fastened to a smooth dry surface. Care must be taken not to damage the surface of the underlayment. DO NOT stretch during installation. FASTENING Fasteners must be corrosion resistant nails long enough to penetrate at least 314 in. into the roof deck. Fasteners must be flush and at a 90 degree angle to the roof deck. For underlayment installed and exposed more than 5 davs and up to 180 days prior to installation of primary roofing, nails with round plastic caps must be used. Follow the nail pattern as marked on the underlayment. See illustration for details. Fasteners on vertical and horizontal laps must not exceed 6 in. on center. When primary roofing is installed within 5 days of initial underlayment application, nails without round plastic caps may be used. (DO NOT USE STAPLES!. If rain and or high winds are expected before final roof covering is applied oyer the underlaymenl nails with round plastic caps must be used. For High Wind Application and Aorida requirements: Fasten the under1ayment at all nail locations indicated by a cross. Fasteners spacing for vertical and horizontal laps must be spaced 6 in. on center. 0 FASTEN AT THESE LOCATIONS FOR All APPLICATIONS + FASTEN AT THESE ADDffiONAL LOCATIONS FOR HIGH-WIND APPUCAnDNS AND FLORIDA For low Slope Application: On pitches 2 in. per foot to 4 in. per foot, cover the deck with two layers of TAMKO SYNTHETIC GUARD UNDERLAYMENT. Begin by applying the underlayment in a 25 in. wide strip along the eaves and overhanging the drip edge by 1/4 to 3/4 in. Place a full48 in. wide sheet over the 25 in. wide starter piece, completely overlapping it. All succeeding courses will be positioned to overlap the preceding course by 25 in. If winter temperatures average 25°F or less, TAMKO's Moisture Guard® self-adhering underlayment or any specialty eaves flashing product should be installed from eaves and rakes to a point to at least 24 in. inside the interior wall line of the building. PROVIDE VENTILATION WHEN USING OVER THE ENTIRE ROOF DECK When using TAMKO SYNTHETIC GUARD UNDERLAYMENT over the entire roof deck the roof must include a system to provide adequate ventilation for all space immediately below the roof deck. Such ventilation system must be designed in accordance with architectural design standards appropriate to the size, nature, and location of the structure and must include both ridge and soffit venting. For further information on providing adequate ventilation, contact your architect, building contractor, building materials supplier, or a qualified roofing consultant. It is the responsibility of the installer to ensure installation is completed according to directions, and that all construction by-laws and codes are met. For questions about TAMKO SYNTHETIC GUARD UNDERLAYMENT or its application, contact TAMKO's Technical Services Department at 800-641-4691. These application instructions were current at the time of printing. To obtain a copy of the most current version of the application instructions, visit us online at tamko.com or call us at 800-641-4691 . This product is covered by a 1 0-year limited warranty. For information regarding or a copy of TAMKO's limited warranty, contact your local TAMKO representative, visit us online at tamko.com, or call us at 800-641-4691. 102016 TAMKO Building Products. Inc. TAMKO Logo and TAMKO are registered trademarks and Synthetic Guard is a trademark of TAMKOO Building Products. Inc. Rev. 12/2016 SYNTHETIC GUARD™ ------PRODUCT DATA SYNTHETIC ONDERLAYMENT CERTIFICATIONS LIMITATIONS PRODUCT DATAt IMPORTANT SAFETY INFORMATION: Use personal fall protection devices when working on a roof. Personal fall protection devices, safety glasses and hearing protection must always be used when applying Synthetic Guard underlayment. Moisture, frost or debris will decrease the traction when walking on Synthetic Guard underlayment. Applicator safety is of utmost importance. SYNTHETIC GUARD underlayment is a non-woven synthetic underlayment with a black coated polypropylene spun bond fabric surface, a polypropylene 5 x 5 scrim, and a black backside coating. USES: For use as a synthetic underlayment to be applied over the deck prior to installation of the final roof covering. It also is intended as a secondary layer for shedding water after installation of the roof system. Synthetic Guard can be used for wood shake, asphalt or composite shingles. • Non-woven surface. • Polypropylene 5 x 5 Scrim. • Lay lines and cap-nail locations printed on the underlayment. Also includes additional high wind and Florida cap-nail locations. • 1 0-Year Limited Warranty (see complete TAMKO Synthetic Underlayment Limited Warranty at tamko.com for details). UNDERLAYMENT PRODUCTS BEGIN TO AGE AS SOON AS THEY ARE EXPOSED TO NATURE. BUILDINGS EXPERIENCE AGING FACTORS DIFFERENTLY, SO IT IS DIFFICULT TO PREDICT HOW LONG A PRODUCT WILL LAST. THAT'S WHY TAMKO PROVIDES A LIMITED WARRANTY ON SYNTHETIC GUARD THAT INCLUDES A BINDING ARBITRATION CLAUSE AND OTHER TERMS AND CONDITIONS WHICH ARE INCORPORATED HEREIN BY REFERENCE. YOU MAY OBTAIN A COPY OF THE LIMITED WARRANTY AT TAMKO.COM OR BY CALLING 1-800-641-4691. lntertek Code Compliance Research Report (CCRR-1 056) Florida Building Code Approved FL-19948 • Underlayment must not be applied to wet or frosty surfaces. CODE COMPUANCE ~s lntertek CCRR·1056 • Underlayment must not be applied to unclean or contaminated surfaces. • Underlayment must not come into contact with hot asphalt or products containing coal-tar pitch. • Once applied, underlayment must not be left exposed beyond 180 days. 9.20 Square Roll Roll Dimensions 48.1" X 250.5' Roll Coveragett 920.59 sq. ft. (± 3.92 sq. ft.) Roll Contains 1004.09 sq. ft. (± 4.09 sq. ft.) Rolls Per Pallet 63 Pallet Size 40" X 48" t All values stated as nominal. "When applied according to instructions. Information included in this product data sheet was current at time of printing. To obtain a copy of the most current version of this product data sheet, visit us online at tamko.com or call us at 800-641-4691. TAMKO Logo and TAMKO• are trademarks and Synthetic Guard is a trademark of TAMKO Building Products, Inc. ~~Koi '-P-~-.-B-o_x_1_4_0_4_•_Jo_p_l_in-.-M-0_6_4_a_o_~-,-4-0-4-.-,-_-a-o-~-6-4-,-~-6-9-,-.-~-m-k_o_._oo_m---------~-.-.o-~-~-,6- BUILDING PRODUCTS ~l TECHNICAL DATA BULLETIN 2014 POLYISO INSULATION LTTR R-VALUES SecurShieldTM SecurShield is a rigid roof insulation panel composed of a closed-cell polyisocyanurate foam core bonded during the manufacturing process to premium performance coated glass facers. Sizes: 4' x 4' and 4' x 8' Thickness: l" to 4.5" SecurShield CD SecurShield CD is a rigid roof insulation panel composed of a closed-cell polyisocyanurate foam core manufactured on-line to an enhanced coated glass facer on each surface side to achieve greater fire resistance over wood decks. Size: 4' x 8' Thickness: l" VER SICO ROOFING SYSTEMS SECURSHIELD THERMAL VALUES Thickness Thickness LTIR Flute (inches) (MM) R-value** Spanability 1.00 25 5.6 2 'Ia" 1.50 38 8.6 4'1a" 1.75 44 10.0 4 3/s" 1.80 46 10.2 4 3/a" 2.00 51 11.4 4 'Is" 2.20 56 12.6 4'!&" 2.50 64 14.4 43/a" 2.60 66 15.0 4 'Is" 3.00 76 17.4 4%" 3.50 89 20.5 4''11" 3.80 97 ® 4'1a" 4.00 102 43/s" 4.30 109 4 3/a" 4.50 114 26.8 4 'Ia" "NEW Long-Term Thermal Resistance Values are based on ASTM C1289-11A effective January 1, 2014, predicting product A-value after five years, which is equivalent to a time-weighted thermal design A-value for 15 years. SECURSHIELD CD THERMAL VALUES Thickness (inches) 1.00 Thickness (MM) 25.4 LTIR R-value** 5.7 Flute Spanability 2 5/e" **NEW Long-Term Thermal Resistance Values are based on ASTM C1289-11A effective January 1, 2014, predicting product A-value after five years, which is equivalent to a time-weighted thermal design A-value for 15 years. A SINGLE SOURCE FOR SINGLE-PLY ROOFING Verslco , PO Box 1289. Carlisle. PA 17013 Tel: 800.992.7663 Fax: 717.960.4036 Web: www.versico.com 1--.• "'~ ., ... ~ ...,_~ ~ila,-.J: ,~. -~~,.~ ·--:..':7'1'«,.; ""''!'~ ~, '\(' -~, ., }'~~~~.·~~:,~:!~4/~:~~ -·::~.':;.;~,-y. : ' ,. ~ ~ iTdi·~~·.~~~f-~~~:··N . I C A L D A T A B U L L E T I N i ~· " '~-~ ' "'~' • ~ • y~ f ~ 2014 POLYISO INSULATION LTTR R-VALUES NEW Long-Term Thermal Resistance Values are based on ASTM C1289-llA effective January 1, 2014, predicting product R-value after five years, wh1ch is equivalent to a t1me-we1ghted thermal des1gn R-value for 15 years. MP-H Polyiso MP-H is a rigid-roof insulation panel composed of a closed-cell polyisocyanurate foam core bonded on each side to fiber- reinforced paper facers. Size: 4' x 4' and 4' x 8' • Thickness: 1" to 4.5" MP-HNB Polyiso MP-HNB is a rigid-roof insulation composite panel composed of a closed-cell polyisocyanurate foam core bonded during the manufacturing process to a fiber-reinforced paper facer on one side and either 7116'' or %" oriented strand board (OSB) on the other. Size: 4' x 8' Thickness: 1.5" to 4.5" VERSICO ~V~ ROOFING SYSTEMS MP-H POLYISO THERMAL VALUES Thickness Thickness LTIA Flute (inches) (MM) A-value** Spanability 1.00 25 5.6 2 'lo" 1.50 38 8.6 4 'Is" 1.75 44 10.0 4%" 1.80 46 10.2 4'1•" 2.00 51 11.4 4 'I•" 2.50 64 14.4 4'/s" 2.60 66 15.0 4 '!," 3.00 76 17.4 4 'I•" 3.50 89 20.5 4%" 3.80 97 22.3 4'/s" 4.00 102 23.6 4 'Is" 4.30 109 25.5 4 'Is" 4.50 114 26.8 4'18" **NEW long-Term Thermal Resistance Values are based on ASTM C1289-11A effective January 1, 2014, predicting product A-value after five years, which is equivalent to a time-weighted thermal design A-value for 15 years. MP-HNB POLYISO THERMAL VALUES Thicknesst Thicknesst LTIA Flute (inches) (MM) A-value Spanability 1.50 38 6.3 4 'I•" 2.00 51 9.2 4 3/o" 2.50 64 12.0 4 3/o" 3.00 76 15.0 4'1a" 3.50 86 18.0 4 '!•" 3.90 96 20.5 4 3/o" 4.00 102 21.1 4 'I•" 4.50 115 24.2 4 '!•" t Thickness is calculated with 'I••" OSB. A SINGLE SOURCE FOR SINGLE-PLY ROOFING Versico, PO Box 1289. Carlisle. PA 17013 Tel: 800.992.7663 Fax: 717.960.4036 Web: www.versico.com Why Grace Ice & Water Shield®? Highest quality seal around roofing fasteners - Delivers best in class roof leak protection Provides confidence that your client's roof won't leak Best adhesion t o the roof deck - Helps ensure watertight seal Prevents costly leaks caused by ice dams and wind-driven rain Forms superior laps - Provides watertight installation with NO special treatment of the laps Premium leak protection without additional labor time Ripcord~ -Split Release On Demand - Makes it easier to waterproof detail areas such as valleys, chimneys, roof to wa ll transitions Robust protection of the roof's most vulnerable areas Longest Performance History- With over 3 5 years of performance history, Grace Ice & Water Shield"' offers the highest confidence f or the life of the roof. Roll Coverage Exposure 225 ft2 200 ft2 108 ft2 90 Days We hope the mformataon here will be helpful. It is based on data and knowledge consadered to be true and accurate, and is offered for consideratiOn, investigation and venflcat1on by the user, but we do not warrant the results to be obta1ned. Please read all statements, recommendations, and suggestions 10 conJunctiOn w1th our .:ond1taons of sale, wh1ch apply to all goods supphed by us. No statement, recommendation, or suggest1on is Intended for any use that would Infringe any patent, copyright, or other th1rd party right. k.e & Water Sh1eld IS a trademark. wh1ch may be reg•stered 1n the United States and/or other countnes, of GCP Appl1ed Technolog1es, Inc. Th1s trademark hst has been cornp1led us1ng ava1lable published informat1on as of the pubhcation date and may not accurately reflect current trademark ov..nersh1p or status. © Copynght 2016 GCP Applied Technolog1es Inc. All nghts reserved GCP Applied Technologres Inc., 62 Whrttemore Avenue. Cambridge, MA 02140 USA. In Canada, GCP Canada, Inc., 294 Clements Road, West, Ajax, Ontano, Canada l1 S 3C6. Pnnted in U 5 A GIWS-222-0316 03/16 CD/PDF ~RA\l[ '\OV\ A \I T.::IJ) T ~\ A. EVv A.ME GRACE gcp applied technologies The Original, Best in Class Roof Underlayment Grace Ice & Water Shield® fully-adhered smooth surface roofing underlayment provides best in class roof leak protection. Its propnetary and time tested rubberized asphalt formulation has been proven to form a watert ight bond with the roof deck and to seal around fasteners used to attach roof coverings. When 1t comes to roof protection. insist on the origina l -Grace Ice & Water Shield ® roofing underlayment. "Groce Ice & Water Shielcf is the brand that I have trusted the most over the last 1 9 years when it comes to roofing underlayments. I rely on its superior ability to protect the most vulnerable roof details from ice dams and wind driven rains." -Mark Cahill, Pres1dent of Cahill Roofing Inc. _..........- Best in class protection against wind driven rain and ice dams Highest quality seal around fasteners The name contractors trust the most to protect their reputations