HomeMy WebLinkAboutVAIL 21 301-302-402 DATA SHEETS.pdfDN-60689:B • 12/3/2012 — Page 1 of 2 FCO-851(A) IntelliQuad™ PLUS Advanced Multi-Criteria Fire/CO Detector Intelligent/Addressable Devices DN-60689:B General World-class fire and carbon monoxide (CO) detection com-bined in a single addressable device provides a practical solu- tion for today’s market. The IntelliQuad PLUS FCO-851(A) Advanced Multi-CriteriaFire/CO Detector is a plug-in, addressable device that pro- vides both fire and carbon monoxide (CO) detection. For fire, the detector combines four separate sensing elements in one unit (smoke, CO, light/flame, and heat) to sense multiple com- ponents of a fire. This approach enables enhanced sensitivity to real fire with heightened immunity to nuisance particulate. For CO, the detector’s electrochemical sensing cell creates aseparate signal for life safety CO detection. CO is a colorless, odorless, and deadly gas that is virtually impossible to detect with the human senses. It is releasedwhenever carbon-based fuels (from fossil fuels to firewood) burn without enough oxygen to form CO2. Because the poten- tial exists for dangerous levels of CO to accumulate in almost any building, legislation mandating the use of CO detection in commercial spaces continues to increase across the U.S. and Canada. The FCO-851(A) is listed to the UL 268 standard for smoke detectors and the UL 2075 standard for system-con-nected life safety carbon monoxide monitoring. The FCO-851(A) should be used in conjunction with the B200S(COA) intelligent sounder base, which can generateeither a Temp 3 pattern for fire or a Temp 4 pattern for CO alarm indication. The B200S(COA) recognizes the System Sensor synchroniza- tion protocol. This enables it to be used as a component of the general evacuation signal — along with other System Sensor horns, horn strobes, and chimes — when connected to a power supply or Fire Alarm Control Panel (FACP) output capa-ble of generating the System Sensor synchronization pulses. With each sounder base carrying a unique address, the FACP can then command an indvidual sounder — or a group ofsounders — to activate. The command set from the panel can be tailored to the specific event, allowing selection of volume, tone, and group. NOTE: The FCO-851(A) is compatible with the NFS-320(C), NFS- 320SYS, NFS2-640, and NFS2-3030 operating with firmware ver- sion 17.0 (or higher) in FlashScan® mode; CLIP mode not sup- ported. Features • Unique ability to detect all four major elements of a fire. • Separate CO detection signal. • Highest nuisance alarm immunity. • Automatic drift compensation of smoke sensor and CO cell. • Uses only one address on the SLC. • RealTest® CO testing capability. • Separates audible signal for fire or CO alarm when used with the B200S base (B200SCOA in Canada). • CO cell end-of-life warning and fault. • FlashScan operation. Sensitivity Settings and Suggested Applications •Level 1: 1% / ft of smoke. Suggested for very clean envi- ronments such as laboratories. •Level 2: 2% / ft of smoke. Suggested for clean environ- ments such as offices. •Level 3: 3% / ft of smoke. Suggested for moderately clean environments such as hotel rooms, dorm rooms. •Level 4: 3% / ft of smoke with different algorithm process- ing and weighting of sensor elements. Suggested for hotel rooms near a shower, boiler rooms. •Level 5: 4% / ft of smoke. Suggested for equipment rooms, kitchens, paint shops. •Level 6: Thermal alarm at 135°F (57°C). Once the CO cell has reached end-of-life, the CO sensor no longer provides life safety protection; however, when the fire detector enters Photo, Thermal, Infrared (PTIR) mode, the fol- lowing sensitivities apply: •Level 1: 1% / ft of smoke. Suggested for very clean envi- ronments such as laboratories. •Level 2: 2% / ft of smoke. Suggested for clean environ- ments such as offices. •Level 3: 3% / ft of smoke. Suggested for moderately clean environments such as hotel rooms, dorm rooms. •Level 6: Thermal alarm at 135°F (57°C). Specifications PHYSICAL SPECIFICATIONS Size: 3.46" (8.79 cm) high x 6.875" (17.46 cm) diameter installed in B200S(COA) base. Shipping weight: 4.6 oz. (130.41 g). Color: Ivory.60689cov.JPGFCO-851(A) in B200S(COA) Sounder Base Page 2 of 2 — DN-60689:B • 12/3/2012 IntelliQuad™ is a trademark and NOTIFIER®, RealTest® and FlashScan® are registered trademarks of Honeywell International Inc.©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. Operating humidity range: 15% – 90% relative humidity (noncondensing). Operating temperature: 0°C to 38°C (32°F to 100°F). Air velocity: 0 – 4000 ft./min. (0 to 20 m/sec.). ELECTRICAL SPECIFICATIONS Operating Voltage range: 15 – 32 volts VDC. Standby current (max. avg.): 300 μA at 24 VDC (one com-munication every 5 seconds with LED blink enabled). Maximum Alarm Current (LED on): 7.2 mA at 24 VDC. CO ALARM ACTIVATION LEVELS Alarm activation levels as defined by UL Standard 2034: Ordering Information NOTE: “A suffix indicates ULC listed model. FCO-851: IntelliQuad PLUS Advanced Multi-Criteria Fire/CO Detector. FCO-851A: IntelliQuad PLUS Advanced Multi-Criteria Fire/CODetector, ULC listed. B200S: Intelligent programmable sounder base. B200SCOA: Intelligent programmable sounder base, ULClisted. Includes CO detector markings in English and French. M02-04-00: Detector Test Magnet. M02-09-00: Telescoping Test Magnet. Agency Listings and Approvals The listings and approvals below apply to the primary product. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL: S1115 (FCO-851). •ULC: S1115 (FCO-851A). •CSFM: 7275-0028:0264. Concentration of CO Maximum Alarm Time Response 70 (+/- 5) PPM 240 min (not less than 60 min) 150 (+/- 5) PPM 50 min (not less than 10 min) 400 (+/- 10) PPM 15 min (not less than 4 min) DN-6937:D • 12/07/2011 — Page 1 of 2 FAPT-851(A) Acclimate® Plus™ Multi-Sensor Low-Profile Intelligent Detector Intelligent/Addressable Devices DN-6937:D General The Notifier FAPT-851(A) Acclimate® Plus™ detector is anintelligent, addressable, multi-sensing, low-profile detector designed for use with Notifier Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). The Acclimate Plus detector uses a combination of photoelec- tric and thermal sensing technologies to increase immunity to false alarms. Unlike traditional intelligent detectors, the Accli- mate Plus detector has a microprocessor in the detector head that processes alarm data. As a result, the Acclimate Plus detector adjusts its sensitivity automatically, without operator intervention or control panel programming. Areas where the Acclimate Plus detector is especially useful include office complexes, schools, college campuses, manu- facturing and industrial facilities, and anywhere else the use ofa particular area may change. The Acclimate Plus detector automatically adjusts its sensitivity to the environment. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed to greatly enhance the speed of communica- tion between analog intelligent devices and compatible systems. Intelligent devices communicate in a grouped fash- ion. If one of the devices within the group has new information,the panel’s CPU stops the group poll and concentrates on sin- gle points. The net effect is response speed greater than five times that of earlier designs. Features • Automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor-based, combination photo and thermal technology. • Compatible with all Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). • Addressable-analog communication. • Sleek, low-profile design. • Two-wire SLC connection. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). • Addresses can be viewed and changed without electronic programmers. • Dual bi-color LED design provides 360° viewing angle. • LEDs lock red when in alarm. In FlashScan, LEDs flash green in standby for normal condition. • Built-in tamper-resistant feature. • Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. • SEMS screws for wiring of the separate base. • Several base options, including relay, isolator, and sounder. • Built-in functional test switch activated by external magnet. • Listed to UL 268. • Capable of heat-only alarm mode, enabled by a special command from the panel. Smoke alarms are ignored. • Low-temperature signal at 45°F +/– 10°F (7.22°C +/– 5.54°C). Specifications Sensitivity: auto-adjusting levels: 1 to 2%/ft. and 2 to 4%/ft. with classic CLIP systems; 1 to 2, 2 to 3, and 3 to 4%/ft. with systems; fixed-sensitivity levels: 1, 2, and 4%/ft. with classic CLIP systems; 0.5, 1, 2, 3, and 4%/ft. with FlashScan systems. Size: 2.0" (5.3 cm) high; base determines diameter. – B210LP(A): 6.1" (15.5 cm) diameter. – B501(A): 4.1" (10.4 cm) diameter. – B200S(A): 6.875" (17.46 cm) diameter. – B200SR(A): 6.875" (17.46 cm) diameter. – B224RB(A): 6.2" (15.748 cm) diameter. Shipping weight: 5.2 oz. (147 g). Operating temperature: 0°C to 38°C (32°F to 100°F). UL-Listed velocity range: 0 – 4000 ft./min. (1219.2 m/min.), suitable for installation in ducts. Relative humidity: 10% – 93% noncondensing. Thermal sensing rating: fixed-temperature setpoint 135°F (57°C). ELECTRICAL SPECIFICATIONS Voltage range: 15 – 32 volts DC peak. Standby current (max. avg.): 300 μA. Loop resistance: 50 ohms maximum; varies according to control panel used. Refer to panel installation manuals. LED current (max.): 6.5 mA @ 24 VDC (“ON”). Installation The FAPT-851(A) plug-in detector uses a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove detec- tors without using a ladder. Suitable mounting base boxes include: FAPT-851(A) in B210LP(A) Base FAPT-851 with B210.png Page 2 of 2 — DN-6937:D • 12/07/2011 Notifier®, ONYX®, FlashScan®, and Acclimate® are registered trademarksand Acclimate Plus™ is a trademark of Honeywell International Inc.©2011 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. • 4.0" (10.16 cm) square box. • 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box. • Single-gang box (except relay or isolator base). NOTE: The FAPT-851(A) detector has the unique ability to adjust sensitivity according to the environment, based on heat and smoke levels. Avoid installing these detectors in locations that are susceptible to rapid and high temperature changes. An example of an incorrect application would be near or in line with the output of a self-contained heater. Agency Listings and Approvals These listings and approvals apply to the modules specified in this. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. •UL Listed: S1115. •ULC Listed: S1115. •MEA Listed: 225-02-E. • FM Approved. •CSFM: 7272-0028:0206. •U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B210LP(A)). •Lloyd’s Register: 11/600013 (NFS2-640, NFS-320/NFS-320C, excluding B210LP(A)). •Maryland State Fire Marshal: Permit # 2122. Ordering Information NOTE: “A” suffix indicates ULC Listed model. FAPT-851: Low-profile intelligent multi-sensor detector. FAPT-851A: Same as FAPT-851 but with ULC Listing. INTELLIGENT BASES NOTE: “A” suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B210LP(A): Plug-in detector base; standard U.S. flanged low- profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A): Flangeless mounting base. B501BP: Bulk pack of B501; package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tem- poral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producingsound output with ANSI Temporal 3 or continuous tone. Replaces B501BH series bases in retrofit applications. B224RB(A): Relay base Screw terminals: up to 14 AWG (2.0mm²). Relay type Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224BI(A): Isolator base. Maximum: 25 devices between iso- lator bases. ACCESSORIES F110: Retrofit flange to convert B210LP to match the B710LP profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Fits U.S. single-gang electrical box. Supported by B210LP(A) and B501(A) bases only. SMB600: Surface mounting kit for use with B210LP(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. T55-127-010: Detector removal tool without pole. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections.