Loading...
HomeMy WebLinkAboutA14-0064 SD5056SB specs.pdfSD505-6SBThe SD505-6SB provides anaudible output at the detector thatis activated.OperationWhen a detector that is connectedto the SD505-6SB is activated,then the sounder base module willstart sounding the programmedoutput pattern (16 possible outputpatterns, 12 preprogrammed, and4programmable outputs, includingANSI 3.41).Features•Adds an audible output functionto an addressable detector• Fully supervised• Can be used with either Style 4,Style 6 or Style 7 (using SD500-LIMs) supervision.• Adds audible output functionswithout using another SLCaddress.• Uses the 12 pre-programmedoutput cadences, (includingANSI-3.41), or the 4programmable outputs of theIntelliKnight FACP.• Mounts to detector base.• UL Listed (meets or exceeds UL217 and UL 464 requirementsfor evacuation signal sound levelof 85 dB at 10 ft.) SpecificationsAux Current Draw:Standby: 1 mAAlarm: 34.3 mAOperating Voltage:SLC Loop:32 VDCAux Input: 24 VDCSLC Current Draw:.082 mAOperating Temperature: 32ºF to 120ºF(0ºC to 49ºC)Humidity: 10 to 93% RH SSDD550055--66SSBB66”” SSoouunnddeerr BBaassee INTELLIKNIGHT ACCESSORY The SD505-6SB adds an audible output function to the IntelliKnight SD505-APS, SD505-AIS, orSD505-AHS addressable detectors. The SD505-6SB can be used as a single station, multi-station oras a system sounder. These powerful capabilities make the SD505-6SB ideal for use in hotels,apartments and dormitories where in room sounders are required. The sounder base is controlled bythe same address as the detector it is mounted with, this saves SLC addresses and makes installationand programming easy. TThhee SSDD550055--66SSBB pprroovviiddeess fflleexxiibblleennoottiiffiiccaattiioonn ccaappaabbiilliittiieess wwhheerree yyoouu nneeeedd iitt.. Model SD505-6SB INTELLIKNIGHT ACCESSORY SSDD550055--66SSBB66””SSoouunnddeerr BBaassee Engineering Specifications Sounder base shall be Silent Knight Module SD505-6SB. The base must be compatible with Silent Knightsmoke detector models SD505-APS, SD505-AHS and SD505-AIS. One detector shall be used with eachsounder base. Must be capable of Style 4 Style 6 or Style 7 (using SD500-LIMs) supervision with out using adevice address on the SLC loop. Modules shall be capable of using 12 Pre- programmed cadences outputs or 4programmable IntelliKnight cadences. SD505-6SBMounting With 6” Base Assembled With Detector and 6” Base(Detector sold separately) Wiring Class A & Class B MADE IN AMERICAP/N 350315 Rev. D© 2011 Honeywell International Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications aresubject to change without notice. For more information, contact SilentKnight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com