Loading...
HomeMy WebLinkAboutPermit Supporting Documents-Garmisch.xlsx2476 S. Garmisch Dr. BUILDING CLASSIFICATIONS AND CODES OCCUPANCY GROUP: STORIES: SQUARE FOOTAGE: SPRINKLERED: APPLICABLE CODES: SYSTEM WIRING TYPES: INITIATING DEVICE CIRCUIT: NOTIFICATION CIRCUIT: SIGNALING LINE CIRCUIT: SYSTEM TYPE: SUPERVISING STATION TYPE: AUDIBLE NOTIFICATION: VISUAL NOTIFICATION: Monitoring Method and Monitoring Agency Method: Agency: DESIGN STATEMENT THIS PROJECT'S DESIGN IS FROM THE ENGINEERED PLANS AND SPECIFICATIONS R 3 story 3832 sf livable Yes 2010 NFPA72 2011 N.E.C. 2012 I.B.C Land Line Central Security, Greeley Colorado Class B (Hardwired) Class B (Hardwired) n/a Central Temporal Private PREPARED BY: ARCHITECTURAL PLANS DATED: MECHANICAL PLANS DATED: ELECTRICAL PLANS DATED: SPECIFICATIONS DATED: ADDENDUMS DATED: 2009 I.F.C VAIL FIRE AMENDMENTS USE: Blueline Architects 03/20/2014 N/A N/A N/A N/A Single Family SYMBOL CHART Fire Alarm Control Panel Annunciator Photo-Electroc Smoke Detetctor 1350F Fixed Temperature Heat Detector Carbon Monoxide Detector Knox Box Mini Horn Relay Control Module Battery Pack End Of Line Power Supervision Module Polarity Reversal Module Radio Frequency Transceiver version 1.061 (6/21/2013) Honeywell Security Battery & Power Budget Calculator © 2003 Honeywell International Inc. All Rights Reserved Select Panel from pulldown list: Selected Panel NOT Comm'l Fire Rated Calculated Current Draw Power Budget Grayed-out device(s) are not supported by selected panel KEYPADS/INTERFACES 6128 6128RF 6137 6139/6139R 6148 6149EX 6150 6150RF 6150V 6150RF 6160/6160CR 6160CR-2 6160PX 6160RF 6160V 6164US 6165EX 6270 6271C 6271CV 6271V 6272CV 6272CSV 6272CBV 6460S 6460W 8132iPK (Symphony) FSA-8 Fire Zone Annunciator FSA-24 Fire Zone Annunciator Add'l Keypd (Enter # and Currents) Add'l Keypd (Enter # and Currents) 2 WIRE & 4 WIRE SMOKE DETECTORS (except Vplex Polling Loop detectors) 2 wire smoke detector (zone powered) 2 wire smoke detector (zone powered) 2 wire smoke detector (zone powered) 2 wire smoke detector (zone powered) ESL 541NCSXT SYS CO1224TR CO Detectors SYS5603 135 Fixed Heat Detectors 12V 4 wire Smoke ( Qnt'y & Currents) MULTI-POWER DEVICES 4208U [powered by polling loop] 4208U [powered by panel aux power] 4208U [powered externally] 4208SN [powered by polling loop] 4208SN [powered by panel aux power] 4208SN [powered externally] 4208SNF [powered by polling loop] 4208SNF [powered by panel aux power] 4208SNF [powered externally] 4208SNF (Class B to A Zone Converter) 4209U Grouped Zone Mux. Module 4209U [powered externally] 4297 Polling Loop Extender Add'l Device (enter quant. & currents) Add'l Device (enter quant. & currents) AUXILIARY POWERED DEVICES PS24 24 volt Power Supply Module 4100SM (no more than one per system) 4204: Enter no. of relays used 4204CF:Enter no. of relays used 4285 Voice Module 4286 with warning speakers 5140DLM Backup Dialer Module 5800RP wireless repeater module 5800TM wireless xmtr module 5881EN receiver 5883 hi-security receiver UVS-QM VA8200 Panel Linking Module VA8201 Alpha Pager Module Add'l Device (enter quant. & currents) Add'l Device (enter quant. & currents) Communicators 7845GSM/7845i-GSM 7845i/7845i-ENT GSMCF/iGSMCF Fire Communicator Vista-GSM/Vista-GSMCN (Vista-21iP only) 7847i/7847i-E Internet Communicator Add'l Device (enter quant. & currents) Add'l Device (enter quant. & currents) PIR Motion Detectors (non Vplex) IS215T IS215TCE IS2260/IS2260T IS2460 IS2500LT Motion Detector IS2535/IS2535T IS2560/IS2560T IS2560TC IS310/IS320 Request to Exit (RTE) 997 Ceiling Mount PIR 998 Wall Mount PIR Motion Detctrs (enter quant. & currents) Motion Detctrs (enter quant. & currents) Motion Detctrs (enter quant. & currents) Motion Detctrs (enter quant. & currents) Dual Tech Motion Detectors (non Vplex) DT-515 DT-6100STC DT-7235T DT-7435/DT-7435C DT-7450/DT-7450MIC DT-7550 Motion Detctrs (enter quant. & currents) Motion Detctrs (enter quant. & currents) Motion Detctrs (enter quant. & currents) Motion Detctrs (enter quant. & currents) grayed-out devices are not supported by selected panel POLLING LOOP DEVICES 4101SN Single Output Relay Module 4190SN Two Zone SIM 4190WH 4191SN-WH 4192CP 4192SD Photoelectric Smoke Det. 4192SDT 4193SN Two Zone SIM 4194 Contact 4196 4209U 4275EX Dual PIR 4275EX-SN Dual PIR 4278EX-SN DT7500SN 4293SN 4939SN WH/BR/GY Surf Mt. Cntct. 4944SN Recessed Contact 4945SN-WH 4959SN Overhead Door Contact 5192SD Smoke Detector 5192SDT Smoke w/ Heat 5193SD Smoke Detector 5193SDT Smoke w/ Heat 998MX PIR IS2500SN PIR FG-1625SN Glass Break Detector Quest2260SN Vplex-VSI Short Isolator Vistakey Add'l VPlex (enter qnt'y & current) Add'l Vplex (enter qnt'y & current) 12V NOTIFICATION DEVICES ON BELL OUTPUT #1 SYS-MHW SYS-P2RK Enter device name, quant., & current Enter device name, quant., & current Enter device name, quant., & current 12V NOTIFICATION DEVICES ON BELL OUTPUT #2 (IF USED) Enter device name, quant., & current Enter device name, quant., & current Enter device name, quant., & current Enter device name, quant., & current Enter device name, quant., & current 12V AUX POWER AND BELL CIRCUIT WIRE RUN DATA Panel Aux Power Wire Run (twin lead) Panel Bell 1 Wire Run (twin lead) Panel Bell 2 Wire Run (twin lead) PS24 Power Supply Battery & Power Budget Calculator © 2003 Honeywell International Inc. All Rights Reserved Selected Panel NOT Comm'l Fire Rated Equivalent panel load @ 24V (converted to 12VDC from 24V full-wave) Power Budget 24V NOTIFICATION APPLIANCES Enter Device Names & Specifications 24V Notification Appliance 24V Notification Appliance 24V Notification Appliance 24V Notification Appliance 24V Notification Appliance 24V Notification Appliance 24V Notification Appliance 24V Notification Appliance 24V Notification Appliance 24V Notification Appliance 24V Notification Appliance 24V Notification Appliance 24V Notification Appliance 24V Notification Appliance 24V Notification Appliance 24V Notification Appliance 24V BELL CIRCUIT WIRE RUN DATA PS24 Output A Wire Run (twin lead) PS24 Output B Wire Run (twin lead) Facility Information Location: Account #: Model: Engineer: Date: SELECTED PANEL MAXIMUM OUTPUT RATINGS Polling Loop (mA) 128 24 104 Current OK Enter Quantity 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Power Overdraw if highlighted Enter Quantity 0 0 0 0 9 6 1 0 Enter Quantity 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Power Overdraw if highlighted Enter Quantity 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Power Overdraw if highlighted Enter Quantity 0 0 0 0 0 0 0 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Polling Loop Overdraw if highlighted! Add 4297 Devices (row 41) Enter Quantity 4 1 0 0 0 Bell #1 Power Overdraw if highlighed! Enter Quantity 0 0 0 0 0 Bell #2 Power Overdraw if highlighed! Units PS24 POWER SUPPLY MODULE, MAXIMUM CAPACITIES Panel 12V Standby (mA) 394.183 0 394.183 Enter Quantity 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Units Mechanical Room Garmisch ADE 128BPT George Sharer/Brad Wolniak 10/17/2014 Standby Auxiliary Power (mA) 750 120.183 629.817 Current OK How many powered externally? 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 How many powered externally? 0 0 0 0 How many powered externally? 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 How many powered externally? 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 How many powered by 4297? 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 How many powered externally? 0 0 0 0 0 How many powered externally? 0 0 0 0 0 Wire Gauge(AWG) Panel 12V Alarm (mA) 580.118 0 580.118 Which PS24 Output? 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Wire Gauge(AWG) Alarm Auxiliary Power (mA) 1000 225.6 774.4 Current OK Standby (aux pwr) 30 60 40 40 30 40 40 80 60 80 45 45 40 50 60 55 40 180 159 159 137 180 180 180 40 40 350 35 35 0 0 Standby (aux pwr) Two-wire smoke detector current is built into the panel budgets. These fields are included to help you create a complete equipment list. The line below indicates if number of detectors exceeds panel capacity, or if the selected panel does not support 2-wire smoke detectors. Quantity of 2 Wire Smoke Detectors OK for selected panel! 0.007 0.02 0 0 Standby (aux pwr) 0 28 28 0 33 33 0 40 40 40 110 110 178 0 0 Standby (aux pwr) 50 25 40 80 160 220 5 80 20 60 80 75 88 165 0 0 10 10 10 10 75 0 0 7 18 4 9 25 20 20 25 35 12 13 0 0 0 0 20 35 20 30 35 40 0 0 0 0 Standby (aux pwr) Standby (aux pwr) Standby (aux pwr) Output A Standby (mA) 570 0 570 Device Standby Load (MA) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Panel Standby (mA) 250 Alarm Current (Aux) 45 120 85 100 55 60 70 105 160 105 150 160 165 150 190 210 70 280 230 230 210 305 305 305 150 150 400 65 130 0 0 Alarm Current (Aux) 0.04 0.04 0 0 Alarm Current (Aux) 0 28 28 0 33 33 0 40 40 40 110 110 178 0 0 Alarm Current (Aux) 100 25 40 80 160 300 15 80 20 60 80 110 88 165 0 0 10 10 10 10 75 0 0 7 18 4 9 25 20 20 25 35 12 13 0 0 0 0 20 35 20 30 35 40 0 0 0 0 Alarm Current (Aux) Alarm Current (Aux) 0.075 0.218 0 0 0 Alarm Current (Aux) 0 0 0 0 0 Ohms per 1000 ft 5.08 8.08 8.08 Output A Alarm (mA) 1700 0 1700 Device Alarm Load (MA) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Ohms per 1000 ft 0 0 Panel Alarm (mA) 330 Calculated Bell Draw Bell Power Budget External Bell Power Req'd (mA): Polling Loop Polling Loop Polling Loop 27.3 0.6 0.6 33.6 0.6 0.6 33.6 0.6 0.6 0 15.5 15.5 0 0 Polling Loop Polling Loop 7 2 2 0.5 0.4 0.4 0.4 1.5 1 1 15.5 1 1 1 2.6 1 1 1 0.5 0.5 1.2 1.2 1.2 1.2 1 1.6 1 6 5 2 0 0 Polling Loop Polling Loop Alarm Current Draw (mA) 225.6 0.518 0 Use TWO identical batteries w/ this AH capacity Output B Standby (mA) 570 0 570 Total Alarm Current Draw (mA) 0 0 Bell #1 Output (mA) 1700 0.518 1699.482 Current OK 0 Total Polling Loop Total Polling Loop Total Polling Loop 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Total Polling Loop Total Polling Loop 0 0 0 0 0 0 0 24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Total Polling Loop Total Polling Loop Run Length 300 300 0 Output B Alarm (mA) 1700 0 1700 Current OK Subtotal A Standby 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Run Length 0 0 Enter Standby and Alarm Times Battery Standby (hours): Alarm Duration (minutes): Recommended Battery Capacity OK for 48-Hr Recharge Bell #2 Output (if used; mA) NA 0 Not Used Total Standby Current 0 0 0 0 0 0 0 0 0 0 45 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Panel Max Output Exceeded if highlighted Total Standby Current 0.063 0.12 0 0 Total Standby Current 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Panel Max Output Exceeded if highlighted Total Standby Current 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 75 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Panel Max Output Exceeded if highlighted Total Standby Current Panel Max Output Exceeded if highlighted Total Standby Current Panel Max Output Exceeded if highlighted Total Standby Current Panel Max Output Exceeded if highlighted Actual Resistance (twin leads) 3.048 4.848 0 Standby/Alarm Durations (from top) Battery Standby (hours): Alarm Duration (minutes): Required Capacity (AH) Recommended Battery Capacity OK for 48-Hr Recharge PS24 PC Board (mA) 40 40 0 Subtotal A Alarm 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Actual Resistance (twin leads) 0 0 Recommended Battery (AH) Maximum Panel Standby Output 750 Total Standby 144.183 Standby Budget 605.817 Current OK Total Alarm Current 0 0 0 0 0 0 0 0 0 0 150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Total Alarm Current 0.36 0.24 0 0 Total Alarm Current 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Total Alarm Current 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 75 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Total Alarm Current Total Sounder Current from Panel Bell #1 0.3 0.218 0 0 0 Total Sounder Current from Panel Bell #2 0 0 0 0 0 Voltage At EOL 11.3123712 11.997488736 12 Maximum Total Standby Output 610 Total Standby 40 Standby Budget 570 Current OK Subtotal B Standby 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Voltage At EOL 24 24 24 5 11.9081135666667 Maximum Panel Alarm Output 1700 Total Alarm 250.118 Alarm Budget 1449.882 Current OK Ext. UL Power Req'd (mA): Total External Current Required 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Total External Current Required 0 0 0 0 Total External Current Required 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Total External Current Required 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Total External Current Required Total Sounder Current (external) 0 0 0 0 0 Total Sounder Current (external) 0 0 0 0 0 Voltage Drop (Percent) 5.73024000000001 2.09272000000027E-02 0 24 5 1.15533333333333 7 7 Maximum Total Alarm Output 4180 Total Alarm 40 Alarm Budget 4140 Current OK Subtotal B Alarm 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Voltage Drop (Percent) 0 0 Battery Contigency Factor Max Battery Supported by Panel 17.2 0 Modifiers (LEDs, etc.) False False False True False False False False False False Modifiers (LEDs, etc.) False False False False False False False False False False False Max. Battery Capacity 34.4 34.4 3 All Keypads? 1 True -16 False True True False False False False False False Unit Selection 1 1 1 4 Unit Selection False Output Selection 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Unit Selection 1 1 False 1 SN Vplex? 1 False 1 True AUI Support? 1 False Commercial Fire Rated 0 False Polling Loop Support 1 False CEILING SPECIFICATIONS: All ceilings are flat and 10’ or less with the exception of: See Ceiling Plans Sequence of Operations Manual Fire Boxes Smoke Detectors Heat Detectors Carbon Monoxide Detectors Sprinkler Water Flow Sprinkler Tamper Switch FACP power failure FACP low battery Open circuit Phone line loss Ground fault Actuate common alarm signal indicator X X X X X Actuate audible / visual alarm signal X X X X X Actuate common trouble signal indicator X X X X X Actuate audible common trouble signal X X X X X Actuate point description X X X X X X X X X Actuate supervisory trouble signal X Actuate tandem detectors voice FIRE within unit Activate DACT & communicate to Central Station dispatch CO/RP X Display change of status X X X X X X X X X X X Actuate horn strobe FDC X Activate DACT & communicate to Central Station dispatch FIRE / RP* X X X X Activate DACT & communicate to Central Station dispatch RP* X X X X X X *RP responsible persons Installed by: P.O. Box 4910 Edwards, CO 81632 phone (970) 926-8788 fax (970) 926-8790 FA-1 FA-2 FA-3 ` George Sharer, NICET III 98481 Signature: 2476 S. Garmisch Dr. WIRE SPECIFICATIONS NOTIFICATION APPLIANCE CIRCUITS INITIATING DEVICE CIRCUIT 18/4 FPLR 18/4 FPLR Building occupancy classifications refer to categorizing structures based on their usage and are primarily used for building and fire code enforcement. They are usually defined by model building codes, and vary, somewhat, among them. Often, many of them are subdivided. The following is based on the International Building Code, the most commonly used building code in the United States: Assembly (Group A) - places used for people gathering for entertainment, worship, and eating or drinking. Examples: churches, restaurants (with 50 or more possible occupants), theaters, and stadiums. Business (Group B) - places where services are provided (not to be confused with mercantile, below). Examples: banks, insurance agencies, government buildings (including police and fire stations), and doctor's offices. Educational (Group E) - schools and day care centers up to the 12th grade. Factory (Group F) - places where goods are manufactured or repaired (unless considered "High-Hazard" (below)). Examples: factories and dry cleaners. High-Hazard (Group H) - places involving production or storage of very flammable or toxic materials. Includes places handling explosives and/or highly toxic materials (such as fireworks, hydrogen peroxide, and cyanide). Institutional (Group I) - places where people are physically unable to leave without assistance. Examples: hospitals, nursing homes, and prisons. In some jurisdictions, Group I may be used to designate Industrial. Mercantile (Group M) - places where goods are displayed and sold. Examples: grocery stores, department stores, and gas stations. Residential (Group R) - places providing accommodations for overnight stay (excluding Institutional). Examples: houses, apartment buildings, hotels, and motels. Storage (Group S) - places where items are stored (unless considered High-Hazard). Examples: warehouses and parking garages. Utility and Miscellaneous (Group U) - others. Examples: water towers, barns, towers.