HomeMy WebLinkAboutA14-0077 Data Sheets.pdfThe high capacity, feature-rich VISTA-20P lets you deliver more value to your customers on each and every sale with up to 48 zones of protection, Internet uploading/downloading, graphic keypad support and dual partitions. VISTA-20P gives you the ability to send alarm signals and upload/download via an Internet Protocol (IP), improving the speed at which information can be delivered to and from the control panel. In addition, the VISTA-20P, used with an AlarmNet®Internet or 4G communicator can be installed in premises without TELCO lines. The panel’s installation advantages, innovative end-user benefits and robust system capacity make the value-priced VISTA-20P an ideal choice for higher end installations. FEATURES VISTA-20P VISTA®CONTROL PANEL • IP alarm reporting and uploading/ downloading capability for Internet and Intranet use via iGSMV4G, 7845i-ENT, GSMV4G or GSMX4G • Supports four graphic touchscreen keypads • Wireless keys can be programmed without using zones • Eight on-board hardwired zones standard (15 when Zone Doubling feature is used) – 40 hardwire expansion zones – 40 wireless expansion zones • Two low current on-board trigger outputs • 100 Event Log viewable at system keypads with time/date stamp • 48 system user codes assignable to either partition • Expandable to 48 total zones when used with hardwired and/or wireless expansion modules • Two independent partitions plus a common partition – Global Arming from any system keypad – Go to function to view or operate one partition from the other – Separate partition account numbers • 16 output devices – Relays (Model 4204 Relay Modules, or 4229 Expansion Module) • Four installer-configurable zone types allows the installer to create custom zone types by assigning all zone attributes • Supports four-wire and up to 16 two-wire smokes – Works with Sentrol CleanMe™ maintenance signal • Multiple actions on output devices depending on system state – Turns lights off when system arms – Turns the same light on when system disarms – Flashes same lights when system is in alarm • Built-in phone line cut monitor with programmable delay and annunciation options – Display on system keypads – Trigger local sounders – Trigger system bell Security Dealer Features • Automatic System Load Shed – During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries. • Dynamic Signaling – Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet radio Valuable End-user Features • Viewable on system keypads: – Exit countdown – Time and date display* – Event log* • Auto keypad backlighting on entry • Keyswitch arming • Programmable macro buttons and single-button arming • Supports a variety of wireless remote controls for single-button operation • User Scheduling – Latchkey reports to pagers – Auto arm/disarm – “User access” time windows • VIP Module allows system control from any touchtone phone • Chime by zone • Fully compatible with Honeywell Total Connect™Remote Services *Requires custom alpha keypad ORDERING VISTA-20P Control Panel VISTA-20PSIA Control Panel for CP-01 SIA Certifications VISTA-20P VISTA®CONTROL PANEL Electrical • Aux. power 12VDC, 600mA maximum • Seven hour standby at 400mA aux. load with four amp hour battery • 16.5VAC/25VA transformer • Alarm output 12VDC, 2.0 amps max. - For UL installations, combined aux. and alarm output cannot exceed 700mA Output Control • Supports up to four relay boards (up to 16 relays) • Optional X-10 transformer/interface (part no. 4300) may be used to control up to 16 X-10 receiving devices Zones • Eight hardwired zones (15 with zone doubling) • Selectable response 10msec, 350msec, 750msec • Assignable to any partition • 20 selectable zone types plus four configurable zone types • Programmable swinger suppression Expansion Devices • 4219 – Eight hardwired zones – 16mA • 4204 – Up to four relays – 15mA standby (each active relay draws an additional 40mA) • 4229 – Eight hardwired zones and two relays – 36mA (each active relay draws an additional 40mA) Accessories • iGSMV4G Internet and Digital Cellular Communicator with Remote Service Capability • 7845i-ENT Enterprise Internet Communicator • GSMV4G Digital Cellular Communicator with Remote Service Capability • GSMX4G Digital Cellular Communicator for VISTA Control Panels • 5881ENL RF Receiver supports up to eight zones – 60mA • 5881ENM supports up to 16 zones – 60mA • 5881ENH supports up to 48 zones – 60mA • 5883 Transceiver supports up to 40 zones – 80mA Keypads • 6162 Custom Alpha Security Keypad – 40mA/120mA • 6162V Voice Custom Alpha Security Keypad – 60mA/190mA • 6162RF Custom Alpha Receiver/Security Keypad – 120mA/210mA • 6152 Fixed-English Security Keypad – 40mA/70mA • 6152V Voice Fixed-English Security Keypad – 60mA/190mA • 6152RF/6152RFFR Fixed-English/French Receiver/Security Keypad – 80mA/105mA • 6152ZN/6152ZNFR Fixed-English/French Security Keypad with Hardwired Zone – 35mA/80mA • 6148 Fixed English LCD – 30mA/55mA • 6280 Color Graphic Touchscreen Keypad with Voice • Tuxedo TouchTM (TUXW) Color Graphic Voice Touchscreen Security Keypad and Home/Business Controller (White) • Tuxedo Touch with Integrated Wi-Fi® (TUXWIFIW) Color Graphic Voice Touchscreen Security Keypad and Home/Business Controller with Integrated Wi-Fi (White) Agency Listings ETL listing • Residential Fire and Burglary: – Household Fire Warning System Units – ANSI/UL 985, 2000/05/26 (5th edition) with revisions up to 2004/04/29 Smoke Detectors • Supports up to 16 two-wire smoke detectors • Supports four-wire smoke detectors Communications • iGSMV4G Internet and Digital Cellular Communicator with Remote Service Capability • 7845i-ENT Enterprise Internet Communicator • GSMV4G Digital Cellular Communicator with Remote Service Capability • GSMX4G Digital Cellular Communicator for VISTA Control Panels • Touchtone or pulse • Formats supported – ADEMCO®Contact ID – ADEMCO 4 + 2 Express – ADEMCO low speed – Sescoa/Radionics • 3 + 1, 4 + 1 and 4 + 2 reporting • Reporting capabilities – Split – Dual – Split/Dual – True dial tone detection • Low battery reports 11.2 – 11.6VDC • AC loss and restoral reporting supported SPECIFICATIONS L/VISTA20PD/D December 2013 © 2013 Honeywell International Inc. For more information: www.honeywell.com/security Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 1.800.467.5875 www.honeywell.com 6160 ALPHA DISPLAY KEYPAD CO06010 L/6160/D September 2006 © 2006 Honeywell International Inc. Honeywell Security & Custom Electronics Honeywell International Inc. PO Box 9035 Syosset, NY 11791 www.honeywell.com ORDERING 6160 Alpha Display Keypad The 6160 Deluxe Keypad is easy to install and simple to use. The attractive white console blends with any décor and features a contoured, removable door that conceals illuminated soft-touch keys. The 6160 also features a new larger and brighter 32-character display with easy-to-read plain-English status messages. The oversized function keys are easily accessed even when the keypad door is closed, and can be programmed for fire, burglary, personal emergencies and other operations. Colored self-adhesive labels are included. • Large, easy-to-use keypad • Keys continuously backlit for greater visibility • Speaker with audible beeps to indicate: - System status - Entry/exit delay - Other alarm situations • Zones and system events displayed in plain English • No confusing blinking lights • Four programmable function keys • System functions clearly labeled • Functions performed by just entering security code plus command • White with removable door blends with any décor FEATURES Physical • 5-5/16"H x 7-3/8"W x 1-3/16"D (135mm x 190mm x 30mm) Current • Standby-40mA • Activated Transmission-160mA Wiring • - (Black): Ground • + (Red): +12 VDC (Aux. Power) • D1 (Green):“Data in” to control panel • D0 (Yellow):“Data out” from control panel Compatibility • Fully compatible with all VISTA controls. SPECIFICATIONS WITH DOOR ATTACHED WITHOUT DOOR Control Unit Accessories, System Backup dialer modules, Model(s) 5140DLM Eight-zone remote point Class A interface modules, Model(s) 4208SNF Eight-zone remote point modules, Model(s) 4208SN, 4208U Enclosures, Model(s) 5800BOX End-of-line resistors, Model(s) 4100EOLR, EOL100, EOL20, EOL22, EOL82, EOLR470K Fire system annunciator keyswitch modules, Model(s) FSAKSM (d) Fire system annunciator modules, Model(s) FSA-24F, FSA-8F Internet and Digital Cellular Fire Communicator, Model(s) IPGSM-4G, iPGSM-COM, IPGSM-DP Internet communicators, Model(s) 7845i-ent, 7845i-entF (c) Isolation modules, Model(s) ECP-Isolator, VPLEX-VSI Keyswitches, Model(s) 4146 (a) LCD keypads, Model(s) 6160CR-2, FA570CR Polling loop extender modules, Model(s) 4297 Relay Module, Model(s) 4204 RF receivers, Model(s) 5881ENHC RF transceiver subassemblies, Model(s) 5883H Sensor Interface Module Gateway, Model(s) 472368 Supervised notification appliance modules, Model(s) 4204CF Transformers, Model(s) 1451 Universal group zoning multiplex modules, Model(s) 4209U Wireless transmitters, Model(s) 5817CB Zone expander modules, Model(s) 4190SN, 4193SN (b), 4193SNP (b) Zone expander/relay module, Model(s) 4101SN-XX UOXX.S789 Control Unit Accessories, System Page Bottom See General Information for Control Unit Accessories, System HONEYWELL SECURITY S789 SUITE 100 2 CORPORATE CENTER DR PO BOX 9040 MELVILLE, NY 11747 USA Page 1 of 2UOXX.S789 - Control Unit Accessories, System 8/9/2013http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=UO... (a) - Must be installed adjacent to an alphanumeric (English language) keypad, Model 6160CR-2 when used as a fire alarm silencing switch. (b) - Must be mounted inside control panel cabinet or within a Listed junction box. Supervised Zone is required for Fire. Unsupervised Zone may be used for Burglary. (c) - For use with Model FOCUS 200 PLUS control unit. (d) - Keyswitch module must be installed adjacent to FSA unit if remote silence/reset desired. NOTE - Model numbers may include a prefix or suffix consisting of numbers and/or letters. For use with compatible Listed control unit systems as indicated in the installation instructions. XX - Where XX indicates enclosure color. © 2013 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2013 UL LLC". Last Updated on 2013-04-30 Questions? Print this page Terms of Use Page Top Page 2 of 2UOXX.S789 - Control Unit Accessories, System 8/9/2013http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=UO... Agency Listings 5600 Series Mechanical Heat Detectors System Sensor’s 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Features Multiple configurations for installations: – Single- and dual-circuit models – Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. Plain housing for residential installations (Model 5601P) Easy-to-use terminal screws A broad range of back box mounting options: – Single gang – 3.5˝ and 4˝ Octagonal – 4˝ square with square to round plaster ring Reversible mounting bracket • • • • • Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit models are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back boxes. And these models accommodate four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. S2101 3016008 199-03-E 7270-1209:227 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2006 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0351-002 • 11/06 • #1676 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number _________, listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 3½-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14–22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601P, 5602, 5621, and 5622 only) Mounting 3½-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact Ratings 6–125VAC / 3A 6–28VDC / 1A 125VDC / 0.3A 250VDC / 0.1A Input Terminals 14–22 AWG Ordering Information Model Circuit Identification Method on Exterior Temperature Rating Activation UL Protected Spacing – 10 Foot Ceiling* 5601P Single None 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5602 Single Lettering 194°F (90°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5603 Single Lettering 135°F (57°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5604 Single Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5621 Dual Lettering 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5624 Dual Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 5601P FX/ROR194°F/9 0 °C5602, 5622 FX135°F/5 7 °C5603, 5623 FX194°F/90 °C 5604, 5624 FX/ROR135°F/5 7 °C5621 Agency Listings CO1224T Carbon Monoxide Detector with RealTest™ Technology The System Sensor CO1224T CO detector provides early warning by using electrochemical sensing technology to measure carbon monoxide levels in the air. Features RealTest• ™ technology allows installer to test detector with CO gas Full compliance with UL 2075• A code required trouble relay• Wiring supervision with SEMS terminals• A six year end-of-life timer• 12/24 VDC• A current draw of 20mA in standby and 40mA in alarm• Versatile mounting for wall and ceiling• Electrochemical sensing technology• With RealTest™ technology, the CO gas sensing cell of the CO1224T CO detector can be tested using a carbon monoxide gas agent. Simply hold the test button for two seconds. After the alarm cycle (temp 4) the green LED will flash about once per second, indicating that the detector is ready to accept CO for testing. Spray a small amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. If dangerous amounts of carbon monoxide is detected, the CO1224T detector will alert residents by sounding and flashing a temp-4 signal alarm. Protection is guaranteed 24/7 by a central station, regardless of whether residents are away from home, sleeping or already suffering from the effects of CO. This specific device is designed for system operation. The detector is fully listed to UL 2075. It offers a code required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station. It also uses SEMS-type terminal Philips head screws to provide a quicker and more positive wiring connection and code required wiring supervision. The CO1224T detector offers a low current draw, allowing more devices to be connected to the panel without having to purchase a more expensive panel or an extra power supply. The CO1224T model will operate on most industry security and fire alarm control panels because it is is a 12/24 VDC detector. 2075 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2008 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.A05-0437-000 • 8/08 • #1953 Ordering Information Part No.Description CO1224T 12/24 volt, 4-wire system-monitored carbon monoxide detector with RealTest™ Technology CO1224T Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide detector shall be a System Sensor model number CO1224T, listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors. The detector shall be equipped with a sounder and a trouble relay. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual color LED indication, which blinks to indicate normal standby, alarm, or end-of-life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end-of-life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size Length: 5.1 in, Width: 3.3 in, Height: 1.3 in Approximate Weight 7 oz Operating Temperature Range 32°F to 104° F (0°C to 40° C) Operating Humidity Range 22 to 90% RH Input Terminals 14 to 22 AWG Mounting Single-gang back box; surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal (standby)Blink 1 per minute —— Alarm —Blink in temp 4 pattern Sound in temp 4 pattern RealTest™ Feature: The System Sensor CO1224T carbon monoxide detector with RealTest™ can evaluate the functionality of the CO sensing cell using canned test agent. NOTE: Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an installation. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes (except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-life Timer: After the detector’s internal sensor has reached the end of its life, a trouble signal will be sent to the panel. This will indicate that it is time to replace the detector. An electrochemical carbon monoxide detector lifespan is approximately six years, and the detector must be replaced by the date marked on the inside of the product. 1.2.3. Push and hold the Test/Hush button for two seconds to enter RealTest mode. The green LED will flash once every second to indicate RealTest mode has started. Spray canned CO agent into the detector. Verify CO sensing at the control panel. The detector will automatically exit RealTest alarm mode after about 20-60 seconds. E S L P R O D U C T I N F O R M A T I O N B U L L E T I N 541 SERIES Low Profile, Self-Diagnostic, Four-Wire, Photoelectric Smoke Detector UL Model numbers: 541C, 541CXT ULC Model numbers: 548C, 548CXT • On-site maintenance alert • SmartHeat™ fixed/rate of rise heats work with photo chamber to catch fires faster • Built-in drift compensation reduces false alarms • Field replaceable optical chamber makes servicing a snap • Small, low profile design blends in with any environment continued ULÒ LISTED The ESL 541 Series self-diagnostic, four-wire smoke detectors are the industry's first conventional direct-wire smoke detectors with analog features such as drift compensation and multi-criteria detection. The 541 Series continually monitor their own sensitiv- ity and operational status, and provide a visual indica- tion if they drift out of the sensitivity range or fail internal diagnostics. This meets NFPA 72 field sensitivity testing requirements without the need for external meters. Additional diagnostic information is activated by apply- ing a magnet near the detector's integral reed switch. This initiates a self-diagnostic routine and provides visual indication of sensitivity level or indicates if service is required. Time between cleaning detectors is dramatically increased because of the 541's built-in drift compensa- tion. This feature, usually only available in analog systems, allows the detector to automatically adjust its sensitivity over time as it becomes dirty, increasing dust life. And when the 541 indicates that cleaning is neces- sary, it's literally a snap with ESL's patented field- replaceable optical chamber. The SmartHeat™ model 541CXT photoelectric smoke detector/fixed rate of rise heat detector includes fast response algorithms for a quick response to both flaming and smoldering fires. Fast response algorithms allow the heat detectors to work intelligently together with the photoelectric smoke detector. As soon as the heat sensor detects a rapid rise in temperature, the sensitivity of the photoelectric sensor increases. This increase allows the sensor to detect smaller particles of combustion quicker.UNDERWRIT ERSLABORATORI ESOFCANADALISTEDBY California State Fire Marshal Approved Sentrol reserves the right to change specifications without notice. ©1999 Sentrol 12345 SW Leveton Dr., Tualatin, OR 97062 Tel.: 503.692.4052 Fax: 503.691.7566 http://www.sentrol.com U.S. & Canada: 800.547.2556 Technical Service: 800.648.7424 FaxBack: 1.800.483.2495 SENTROL ESL a product of sentrol E-3754-FLG15K-0399 541 Series ESL Photoelectric Smoke Detectors Dimensions: ©1998 Sentrol. Certain items in the Product Information Bulletin are protected under one or more of the following patents: 5,546,074; 5,708,414; 5,798,701; 5,821,866. Model No. Description 541C 4-wire, photoelectric, 12-24 V DC, UL listed 541CXT 4-wire, photoelectric, 12-24 V DC, multi-criteria algorithms, fixed/rate of rise heat, UL listed 548C 4-wire, photoelectric, 12-24 V DC, ULC listed 548CXT 4-wire, photoelectric, 12-24 V DC, multi-criteria algorithms, fixed/rate of rise heat, ULC listed 541C-10PK 541C 10-Pack, not individually boxed 541CXT-10PK 541CXT 10-Pack, not individually boxed Accessories 401 Test magnet in plastic shell for pole mounting SM-200 Smoke! in a Can ® (canned smoke) for functional testing of smoke detectors 211 Replacement optical chambers (set of 10) Specifications: Product Data Voltage..............................................................8.5 – 33 V DC Maximum ripple (pk to pk) ....................................10% (Vp - p) Typical average standby current (24V) ........................70 mA Typical alarm current (24V) .......................................... 15 mA Alarm contacts ..........................500mA @36 V DC (resistive) Sensitivity — photoelectric .................. 3.1% + 0.50 – 1.00% Operating temperature ............... 32°F to 100°F (0° to 37°C) Operating humidity range ............ 0 to 95% Non-condensing RFI Immunity ........................ 20 V/m minimum; 0-1000 MHz Color ....................................................White head and base Field wiring size ................................................... 12-24 AWG Detector packaging............................10 detectors per carton Heat detector specifications ............ Rate of rise — 15°F/min and >105°F (8.3°C/min and > 40.6°C) Fixed — 135°F (57°C) Drift compensation adjustment........................... 1.0%/ft. max Detector head dimensions...................... 5” (12 cm) diameter 2” (5 cm) height Mounting dimensions..................... 4.75” (12.5 cm) diameter; 0.3” (0.8 cm) height Reset time.................................................1 second minimum Listings..........................................................UL, ULC, CSFM Architectural and Engineering Specifications The ESL 541 Series photoelectric smoke detector is a low profile, self-diagnostic , four-wire detector that monitors its own sensitivity and operational status. This detector meets NFPA 72 field sensitivity requirements without the need for external meters. Built-in drift compensation automatically adjusts the sensitivity as the detector gets dirty. Normal sensing occurs every 9 seconds. This rate doubles when a signal exceeding the alarm threshold value is sensed. Two additional successive signals above the threshold level will initiate an alarm. See installation instructions for information about correct installation and maintenance. The proprietary optical sensing chamber is field replaceable, allowing quick and easy cleaning and maintenance. 2" (5cm)5" (12cm)