Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A15-0008 cut sheets.pdf
PowerSeries Control Panels v4.5 Features That Make a Difference: • CO detector support: wireless (WS4913) or hardwired (generic) • Updated PowerSeries Keypads (PK and RFK models) support CO detectors • Updated PowerSeries Wireless Receiver (RF5132) supports wireless CO detectors • Alternate communicator call routing via GPRS and IP • Automatic Contact ID over GPRS • Automatic Sync for alternate communicators Standard PowerSeries Features: • Template programming • Local and remote downloading • Programmable Daylight Savings Time • Automatic CID • 2-way audio • 1 time use code • Keypad lockout • Programmable false alarm reduction features including audible exit delay and fault, quick exit, automatic arm/ disarm, programmable bell delay timer, etc Contact your DSC distributor www.dsc.com | 1-888-888-7838 panels, keypads & modules Front-Line Protection Against The Silent Threat Of Carbon Monoxide Poisoning Colorless, tasteless, odorless but deadly, carbon monoxide (CO) is impossible to detect without a warning device. With the PowerSeries v4.5 Control Panel, either wireless or hardwired CO detectors can be easily integrated into the security system. Installers have the option of using the DSC wireless CO detector (WS4913) - the perfect solution for difficult-to-wire locations, with its compact design, battery power and wireless capability - or the hardwired CO detector. Flexible, Alternate Alarm Communication Methods Traditional phone lines are becoming increasingly less common in many homes and businesses as more people opt for VoIP (Voice over IP) or cellular phones. The PowerSeries v4.5 Control Panel gives customers the option to combine alarm reporting paths through Public Switched Telephone Network (PSTN), Internet or GPRS/GSM channels. Having Internet with GSM/GPRS as back- up provides complete security with the additional benefit of increased recurring monthly revenue (RMR) for dealers. Reduce Installation Time with Easy to Program PC-Link The new Automatic Sync feature enables T-Link or GS Communicators to communicate automatically using the format and account number predefined in the panel programming, reducing the risk of programming errors and on-site install time. Combined with template programming and end-of-line configuration, quicker more accurate installations means more installations per day with more revenue. PowerSeries v4.5 Control Panels: Feature-Rich with Proven Performance PowerSeries Control Panels have a proven reputation for providing the value and dependability that security professionals demand. The modular design of the PowerSeries v4.5 Control Panels provides even more value-added features including support for CO detectors, an automatic synching feature to reduce install time and the flexibility of different alarm reporting paths. panels, keypads & modules For product information www.dsc.comProduct specifications and availability subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies. ©2011 2011-07 Compatibility: • User Interfaces include LED, Picture Icon LCD or Full Message LCD • Wireless Receivers, Devices and Detectors, including CO Detectors • Audio Alarm Verification • Telephone Interface/Automation Control • High & Low Current Output Expansion • Alternate Communication Options • Hardwired Expansion and Detectors • Addressable Expansion and Detectors • Windows™ Software for PC Downloading • Access Control Integration Specifications Power Supply ..................................16.5 VAC/40 VA @ 50/60 Hz Current Draw (Panel) ........................................110 mA (Nominal) Auxiliary & Output ................................13.75 ± 5% VDC /700 mA Bell Output ..........................................13.75 ± 5% VDC /700 mA Operating Environment .........................32º to 120º F (0º to 49º C) Relative Humidity ........................................................93% (Max.) Battery Requirement .......................................4 Ah/ 7Ah / 14 AHr PN 30001305Features PC1616 PC1832 PC1864 On-Board Zones 6 8 8 Hardwired Zones 16 (1 x PC5108)32 (3 x PC5108)64 (7 x PC5108) Wireless Zones 32 32 32 Keypad Zone Support Yes Yes Yes Keypads 8 8 8 On-board PGM Outputs PGM 1 = 50 mA PGM 2 = 300 mA PGM 1 = 50 mA PGM 2 = 300 mA PGM 1,3,4 = 50 mA PGM 2 = 300 mA PGM Expansion 8 x 50 mA (PC5208) 4 x 500 mA (PC5204) 8 x 50 mA (PC5208) 4 x 500 mA (PC5204) 8 x 50 mA (PC5208) 4 x 500 mA (PC5204) Partitions 2 4 8 User Codes 47+ Master Codes 71+ Master Codes 94+ Master Codes Event Buffer 500 Events 500 Events 500 Events Individual Specification by PowerSeries v4.5 Type Make PowerSeries v4.5 Control Panel your preferred choice. Available in three different configurations (PC1616/PC1832/ PC1864), the PowerSeries v4.5 Control Panel has the scalability, versatility and flexibility to work in small residential to medium-sized commercial installations. Modern, slim-line landscape keypad Large, backlit keypad buttons 5 programmable function keys Input/Output terminal can be programmed to operate as a zone input, programmable output or as a low temperature sensor Individual FAP keys Multiple door chime per zone Adjustable backlight and keypad buzzer Available in black or white bezels Wire channel Dual wall-mount and front cover tamper Easy-to-install mounting hinge Surface or single-gang box mount PK5500 PK5516 PK5501 PK5508 RFK5500 RFK5516 RFK5501 RFK5508 PowerSeries high-quality, slim-profile keypads use advanced plastics technology to achieve a clean, unobtrusive look that homeowners welcome and installers will appreciate for their easy programming and installation.The keypads feature an input/output terminal that can be programmed to operate as a zone input, programmable output or as a low temperature sensor.The keypads also include adjustable backlit keys that address low-light situations and five programmable keys for simple one-button activation of system functions. PK5500/ RFK5500 64-zone full-message keypads support eight languages, global partition status and full, 32-character programmable phrases. DSC POWERSERIES™KEYPADS Features Common to all Keypads: P/N30000364R002PrintedinCanadaDistributed by: For product information www.dsc.com Product specifications and availability subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies. ©2007 2007•02 Ordering Information: PK5500 . . . . . . . . . . . . . . . . . . . . . . 64-Zone Full-Message Keypad RFK5500 . . . . . . . . . . . . . . . . . . . . . Wireless 64-Zone Full-Message Keypad PK5501 . . . . . . . . . . . . . . . . . . . . . . 64-Zone LCD Picture ICON Keypad RFK5501 . . . . . . . . . . . . . . . . . . . . . Wireless 64-Zone LCD Picture ICON Keypad PK5516 . . . . . . . . . . . . . . . . . . . . . . 16-Zone LED Keypad RFK5516 . . . . . . . . . . . . . . . . . . . . . Wireless 16-Zone LED Keypad PK5508 . . . . . . . . . . . . . . . . . . . . . .8-Zone LED Keypad RFK5508 . . . . . . . . . . . . . . . . . . . . . Wireless 8-Zone LED Keypad DSC POWERSERIES™KEYPADS Easy To Use To simplify usage, the keypads feature five programmable keys for easy one-button activation of system functions.The default tasks assigned to the five function keys are stay arming, away arming, door chime, smoke detector reset and quick exit.With the quick exit function there’s no need to disarm and rearm the system every time an occupant leaves the house or lets the dog out, for example. Integrated Temperature Sensor The keypads’ integrated temperature sensor can be programmed to activate when room temperature dips below 43°F (6°C) and restores at 47°F (8°C).Built-in logic prevents the panel from cycling in and out of alarm mode during minor temperature fluctuations,helping to reduce false alarms. Flexibility RF versions of the keypads are available.They include all of the same features as their hardwired equivalents and are able to support 32 wireless zones and 16 wireless keys without taking up a wireless zone slot. Compatibility The keypads are compatible with all PowerSeries control panels. Specifications Dimensions . . . . . . . . . . . . . . . . . . . . . . 6 1/16”x 4 7/16”x 13/16” (154 mm x 113 mm x 20.5 mm) LCD Viewable Area . . . . . . . . . . . . . . . . 3 9/10”x 15/16" (99 mm x 24 mm) Current Draw . . . . . . . . . . . . . . . . . . . .125 mA (Max) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Voltage . . . . . . . . . . . . . . . . . . . . . . . . . 12 VDC Nominal Operating Environment . . . . . . . . . . . . 32° to 120° F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(0° to 49° C) Relative Humidity . . . . . . . . . . . . . . . . . 5 to 93% Automatic drift compensation Self-diagnostics Easy-maintenance removable smoke chamber Non-contact sensitivity testing with handheld test meter ( F S D - 1 0 0 ) Built-in, dual-sensor heat detector (option) Scheduled test from control panel (MAXSYS) Removable terminals Low profile design Locking/Non-locking mounting plate UL listed for commercial and residential applications DSC Addressable Photoelectric Smoke Detectors FSB-210 SeriesDSC addressable photoelectric smoke detectors (FSB-210 series) incorporate a low profile design andf e a t u res that help reduce false alarms and pro v i d ereliable smoke detection. Designed for use with theM A X S Y S®PC4020CF commercial fire panel and PowerSeries control panels (Power832® and Power864T M) via the PC5100 addressable zone expander, the detectors include automatic drift compensation, self-diagnostics, and easy-maintenance removable chambers. Precise and quick sensitivity testing is easily accomplished with the handheld test meter (FSD-100). The detectors are UL listed for c o m m e rcial and residential applications. Contact your DSC distributor w w w . d s c . c o m 1 - 8 8 8 - 8 8 8 - 7 8 3 8 Product Features: 30000173 R2 FSB 210 Spec.qxd 11/18/05 1:32 PM Page 1 DSC Addressable Photoelectric Smoke Detectors FSB-210 Series Distributed by: For product informationwww.dsc.com Product specifications and availability subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies. ©2005 2005•11 Ordering Information: FSB-210B…2-Wire Addressable Photoelectric Smoke Detector without Heat Sensor FSB-210BT…2-Wire Addressable Photoelectric Smoke Detector with Heat Sensor Accessories FSD-100…Handheld Test Meter FSD-101…Broom Handle Adapter for FSD-100 Specifications MECHANICAL Diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.8” (147 mm) Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.077” (52.8 mm) Color . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .White Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . .Surface mount with screws Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Twist on/off either locking or . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .non locking ELECTRICAL Maximum Operating Voltage Range. .Panel addressable loop voltage Maximum Standby Current . . . . . . . . .1.6 mA Maximum Alarm Current: FSB-210(T) . . . . . . . . . . .1.8 mA SENSITIVITY Nominal: 3.0% +/-0.8% obscuration/ft. (UL) HEAT SENSOR Alarm: Fixed-temperature 135°F (57.2°C) ENVIRONMENTAL Operating Environment . . . . . . . . . . . . .32°to 100°F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(0°to 37.8°C) Relative Humidity . . . . . . . . . . . . . . . . . . .5 to 95% Compatibility DSC addressable photoelectric smoke detectors are compatible with the MAXSYS®PC4020CF commercial fire panel and PowerSeries control panels (Power832 a n d Power864) via the PC5100 addressable zone expander. False Alarm Reduction DSC is committed to reducing false alarms and has integrated anumber of features into its addressable photoelectric smokedetectors to provide reliable detection. One important feature isautomatic drift compensation. It provides a constant level ofsensitivity performance for long-term, false-alarm-free operation.As dust accumulates in the detector, it compensates to maintain the original factory-set sensitivity and thereby minimizes the potential for false alarms. If the detector reaches its limit of compensation, it will indicate a trouble condition well before the sensitivity increases to a level where false alarms will be generated. Non-Contact Sensitivity Testing Precise and quick sensitivity testing is easily accomplished with the non-contact handheld test meter ( F S D - 1 0 0 ). Powered by a standard 9 V alkaline battery and small enough to fit inside a shirt pocket, the test meter holds 500 readings that can be downloaded to any computer. To initiate a reading, a technician simply holds the test meter near a DSC smoke detector and activates the detector’s test button. 30000173 R2 FSB 210 Spec.qxd 11/18/05 1:32 PM Page 2 Agency Listings 5600 Series Mechanical Heat Detectors System Sensor’s 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Features • Multiple configurations for installations: – Single- and dual-circuit models – Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. • Plain housing for residential installations (Model 5601P) • Easy-to-use terminal screws • A broad range of back box mounting options: – Single gang – 3.5˝ and 4˝ Octagonal – 4˝ square with square to round plaster ring • Reversible mounting bracket Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit models are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back boxes. And these models accommodate four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/ rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. S2101 3016008 CS630 7270-1653:0167 5601P 5621 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2013 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. SPDS30001 • 7/13 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number _________, listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 3½-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14–22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601P, 5602, 5621, and 5622 only) Mounting 3½-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact Ratings 6–125VAC / 3A 6–28VDC / 1A 125VDC / 0.3A 250VDC / 0.1A Input Terminals 14–22 AWG Ordering Information Model Circuit Identification Method on Exterior Temperature Rating Activation UL Protected Spacing – 10 Foot Ceiling* 5601P Single None 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5602 Single Lettering 194°F (90°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5603 Single Lettering 135°F (57°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5604 Single Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5621 Dual Lettering 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5624 Dual Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 5601P FX/ROR194°F/9 0 °C5602, 5622 FX135°F/5 7 °C5603, 5623 FX194°F/90 °C 5604, 5624 FX/ROR135°F/5 7 °C5621 Agency Listings CO1224T and CO1224TR Carbon Monoxide Detectors with RealTest® Technology The System Sensor CO1224T and CO1224TR (round) Carbon Monoxide (CO) Detectors use a highly accurate and reliable electrochemical sensing cell to provide early warning of dangerous CO levels. Features • RealTest® enables a functional test using canned CO • Full compliance with UL 2075 • A code-required trouble relay • Wiring supervision with SEMS terminals • A six-year end-of-life timer • 12/24 VDC • A low current draw of 20 mA in standby and 40 mA in alarm • Versatile mounting for wall and ceiling • Accurate and reliable electrochemical sensing technology • Optional CO-PLATE CO Detector Replacement Plate to upgrade previously installed competitor detectors to the CO1224T With RealTest® technology, the CO gas sensing cell used in the CO1224T and CO1224TR CO detectors can be tested using a CO gas agent, fully meeting the requirements of NFPA 720: 2009. Simply put the detector into RealTest mode, spray a small amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. (See the reverse page or the user manual for complete instructions.) When dangerous amounts of CO are detected, the CO1224T and CO1224TR detectors alert residents by sounding and flashing a temp 4 signal alarm. With 24/7 central station monitoring, residents are guaranteed protection whether they are away from home, sleeping, or already suffering from the effects of CO. The CO1224T and CO1224TR are designed for system operation. These detectors are fully listed to UL 2075 and offer a code- required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station. The CO1224T and CO1224TR also use SEMS-type terminal Philips head screws for quicker and more positive wiring connections and code-required wiring supervision. With a low current draw, these detectors enable more devices to be connected to the panel, limiting the need to purchase extra power supplies or more expensive panels. As 12/24 VDC detectors, the CO1224T and CO1224TR will operate on most industry security and fire alarm control panels. E307195 E304075 5276-1653:0194 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.SCDS00100 • 4/12 Ordering Information Part No.Description CO1224T 12/24 volt, 4-wire system-monitored carbon monoxide detector with RealTest® Technology CO1224TR 12/24 volt, 4-wire system-monitored round carbon monoxide detector with RealTest® Technology CO-PLATE CO detector replacement plate to cover the footprint of previously installed competitive detectors as necessary CO1224T and CO1224TR Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide (CO) detector shall be a system-connected System Sensor model number CO1224T or CO1224TR listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors. The detector shall be equipped with a sounder and a trouble relay. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual-color LED indication that blinks to indicate normal standby, alarm, or end-of-life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end-of-life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. The detector shall perform in the detection of CO up to 12,000 feet above sea level and alarm within the time specified by ANSI/UL 2034 for CO concentrations of 70, 150 and 400 parts per million (ppm), as verified by a Nationally Recognized Test Laboratory. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size: CO1224T Length: 5.1 in, Width: 3.3 in, Height: 1.3 in CO1224TR Diameter: 6 in, Height: 1.3 in Approximate Weight CO1224T: 7 oz ; CO1224TR: 11 oz Operating Temperature Range 32°F to 104° F (0°C to 40° C) Operating Humidity Range 22 to 90% RH Input Terminals 14 to 22 AWG Mounting Single-gang back box; surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal (standby)Blink 1 per minute —— Alarm —Blink in temp 4 pattern Sound in temp 4 pattern RealTest® Feature: The System Sensor CO1224T and CO1224TR Carbon Monoxide Detectors with RealTest enable evaluation of the functionality of the CO sensing cell using a canned CO test agent. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes (except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-Life Timer: After the detector’s internal sensor has reached the end of its life, a trouble signal will be sent to the panel to indicate it is time to replace the detector. An electrochemical CO detector lifespan is about six years. The detector must be replaced by the date marked on the inside of the product. CO-PLATE: System Sensor also offers the CO-PLATE CO Detector Replacement Plate to cover the footprint (when necessary) of previously installed competitive carbon monoxide detectors that require replacement. 3. Push and hold the Test/Hush button for two seconds to enter RealTest mode. The green LED will flash once every second to indicate RealTest mode has started. Spray canned CO agent into the detector. CO-PLATE Verify CO sensing at the control panel. The detector will automatically exit RealTest alarm mode after about 20-60 seconds. NOTE: Check with local codes and the AHJ to determine if a functional gas test is desired for an installation. 1.2. Agency Listings Mini-Horns The SpectrAlert® Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. Features • 12 and 24V operation • High and low volume settings • Temporal and non-temporal tones • Mounts to single gang back box • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series Mini-Alert™ sounders • Listing for ceiling or wall mounting The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini-horns offer high and low volume settings, and temporal or non-temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini-horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply. They are listed to Underwriter’s Laboratories Standard UL 464 for fire protective signaling systems. S4011 3028007 CS1099 7135-1653:196 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS01500 • 3/12 Ordering Information Part No.Description MHR Mini-Horn, Red MHW Mini-Horn, White SpectrAlert® Advance Mini-Horn Specifications Architectural/Engineering Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box. Mini-horn shall be listed to Underwriter’s Laboratories Standard UL464 for fire protective signaling systems. Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. When used with the Sync•Circuit™ Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.6˝L × 2.9˝W × .45˝D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F (0°C to 49°C) Mounting Surface: deep single-gang back box (23/4˝ deep) Flush: Standard 4˝ × 4˝ back box with single gang mud ring, which allows sufficient clearance for conduit entrance. Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8–33 Operating Voltage with MDL 9–33 UL Sound Output and Current Draw Data Sounder Output (dBA) Switch Setting Pattern Output Level 8–17.5 VDC 8–17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16–33 VDC 16–33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- temporal High 72 71 75 74 80 79 4 Non- temporal Low 70 69 73 72 78 77 Sounder Current Draw (mA RMS) Switch Position Sound Pattern Volume 8–17.5 Volts 16–33 Volts DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19