Loading...
HomeMy WebLinkAbout351180-A IDP-FIRE-CO.pdf•UL 268 and UL 2075 listed•Separates audible signal for fire or CO alarmwhen used with e B200S base•CO cell end-of-life warning and fault CompatibilityThe IDP-FIRE-CO is compatible with thefollowing FACPs:• IFP-1000/ECS Intelligent Fire Panel•IFP-100/ECS Intelligent Fire Panel• IFP-50 Intelligent Fire Panel P/N 351180 Rev ACopyright © 2012 Honeywell International Inc. Advanced Multi-Criteria Fire/CO DetectorIDP-FIRE-COThe IDP-FIRE-CO is a plug-in, addressable device thatprovides both fire and carbon monoxide (CO) detection. Forfire, the detector combines four separate sensing elements inone unit (smoke, CO, light/flame, and heat) to sense multiplecomponents of a fire. This approach enables enhancedsensitivity to real fire with heightened immunity to nuisanceparticulate. For CO, the detector’s electrochemical sensingcell creates a separate signal for life safety CO detection.Released through the incomplete burning of various fuels,CO is a colorless, odorless and deadly gas that is virtuallyimpossible to detect with the human senses. Because thepotential exists for dangerous levels of CO to accumulate inalmost any building, legislation mandating the use of COdetection in commercial spaces continues to increase acrossthe U.S. and Canada. The IDP-FIRE-CO is listed to the UL2075 standard for system-connected life safety carbonmonoxide monitoring.The IDP-FIRE-CO should be used in conjunction with theB200S intelligent sounder base, which can generate either aTemp 3 pattern for fire or a Temp 4 pattern for CO alarmindication.The B200S recognizes the System Sensor synchronizationprotocol. This enables it to be used as a component of thegeneral evacuation signal, along with other System Sensorhorns, horn strobes, and chimes, when the IDP-FIRE-CO isconnected to a power supply or Fire Alarm Control Panel(FACP) output capable of generating the System Sensorsynchronization pulses. With each sounder base carrying aunique address, the FACP can then command an individualsounder, or a group of sounders, to activate. The commandset from the panel can be tailored to the specific event,allowing selection of volume, tone, and group. For moreinformation on the B200S refer to Data Sheet P/N 351182.Features• Unique ability to detect all four major elements of a fire:-Smoke - Carbon Monoxide (CO)-Light/flame - Heat•Separate CO detection signal•Highest nuisance alarm immunity•Automatic drift compensation of smoke sensor and CO cell•Uses only one address on the SLC•RealTest® CO testing capability IDP-FIRE-CO installed in a B200S Sounder Base Agency Listings SpecificationsPhysicalBase Diameter: 6.875” (17.46 cm) installed in a B200S baseBase Height: 3.46” (8.79 cm) installed in B200S baseShipping Weight: 4.6 ozColor: IvoryOperatingTemperature Range: 32° F to 100° F (0° C to 38° C)Humidity: 15 to 90% relative humidity(non-condensing)Air Velocity: 0 to 4,000 ft/min (0 to 20 m/sec)ElectricalOperating Voltage: 15 to 32 VDCMaximum Standby: 300µA at 24 VDC (no communication every 5 secondswith LED blink enabled)Maximum Alarm Current (LED on): 7.2 mA at 24 VDCSensitivity Settings & Suggested ApplicationsLevel 1: 1% per foot (30.48 cm) of smoke. Very clean environments: Used in laboratoriesLevel 2: 2% per foot (30.48 cm) of smoke. Clean environments: Used in officesLevel 3: 3% per foot (30.48 cm) of smoke. Moderately clean environments: Used in hotel rooms, dorm rooms.Level 4: 3% per foot (30.48 cm) of smoke with different algorithm processing and weighting of sensor elements. Used in hotel rooms near a shower, boiler rooms.Level 5: 4% per foot (30.48 cm) of smoke. Used in equipment rooms, kitchens, paint shop.Level 6: Thermal alarm at 135° F (57° C) Warning:After the CO cell has reached the end-of-life,the CO sensor no longer provides life safety protection.However, when the fire detector enters Photo, Thermal,Infrared (PTIR) mode, the following sensitivities apply:Level 1: 1% per foot (30.48 cm) of smoke. Very clean environments- Used in laboratories.Level 2: 2% per foot (30.48 cm) of smoke. Clean environments - offices.Level 5: 3% per foot (30.48 cm) of smoke. Moderately clean environments- Used in hotel rooms, dorm rooms.Level 6: Thermal alarm at 135° F (57° C). CO Monitoring UL Standard Reference - AlarmThresholds are as follows: Note: Per UL Standard 2075, the IDP-FIRE-CO hasbeen tested to the sensitivity limits defined in ULStandard 2034. Ordering InformationIDP-FIRE-CO Multi-Criteria CO DetectorNote: Due to the unique nature of this detector,please consultyour Fire Alarm Control Panel Manufacturer forthe specific model and compatibility. AccessoriesB200S Intelligent Sensor Sounder BaseM02-04-01 Detector Test MagnetM02-09-01 Telescoping Test Magnet Parts Per Million Detector Response Time70 ± 5 ppm 60-240 min.150 ± 5 ppm 10-50 min.400 ± 10 ppm 4-15 min. Made in the U.S.A. This document is not intended to be used for installation purposes. We try to keep ourproduct information up-to-date and accurate. We cannot cover all specific applications oranticipate all requirements. All specifications are subject to change without notice. Formore information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610Phone: (800) 328-0103, Fax: (203) 484-7118. www.farenhyt.com