HomeMy WebLinkAboutIDP-FIRE-CO.pdfCompatibilityThe IDP-FIRE-CO is compatible with thefollowing FACPs programmed for SystemSensor protocol: (Firmware version 12.0 orhigher)•IFP-1000 Intelligent Fire Panel•IFP-1000ECS Emergency CommunicationSystem with Fire Alarm Control Panel•IFP-100 Intelligent Fire Panel•IFP-100ECS Emergency CommunicationSystem with Fire Alarm Control Panel•IFP-50 Intelligent Fire Panel P/N 351180 Rev ACopyright © 2012 Honeywell International Inc. Advanced Multi-Criteria Fire/CO DetectorIDP-FIRE-COThe IDP-FIRE-CO is a plug-in, addressable device thatprovides both fire and carbon monoxide (CO) detection. Forfire, the detector combines four separate sensing elements inone unit (smoke, CO, light/flame, and heat) to sense multiplecomponents of a fire. This approach enables enhancedsensitivity to real fire with heightened immunity to nuisanceparticulate. For CO, the detector’s electrochemical sensingcell creates a separate signal for life safety CO detection.Released through the incomplete burning of various fuels,CO is a colorless, odorless and deadly gas that is virtuallyimpossible to detect with the human senses. Because thepotential exists for dangerous levels of CO to accumulate inalmost any building, legislation mandating the use of COdetection in commercial spaces continues to increase acrossthe U.S. and Canada. The IDP-FIRE-CO is listed to the UL2075 standard for system-connected life safety carbonmonoxide monitoring.The IDP-FIRE-CO should be used in conjunction with theB200S intelligent sounder base (sold separately), which cangenerate either a Temp 3 pattern for fire or a Temp 4 patternfor CO alarm indication.With each sounder base carrying a unique address, theFACP can then command an individual sounder, or a groupof sounders, to activate. The command set from the panelcan be tailored to the specific event, allowing selection oftone, and group. For more information on the B200S refer toData Sheet P/N 351182.Features•Unique ability to detect all four major elements of a fire:- Smoke- Carbon Monoxide (CO)- Light/flame- Heat• Separate CO detection signal• Highest nuisance alarm immunity• Automatic drift compensation of smoke sensor and CO cell• Uses only one address on the SLC• RealTest® CO testing capability• UL 268 and UL 2075 listed• Separates audible signal for fire or CO alarm when usedwith B200S base• CO cell end-of-life warning and fault IDP-FIRE-CO installed in a B200S Sounder Base(sold separately) Agency Listings SpecificationsPhysicalDiameter:6.875” (17.46 cm) installed in a B200S baseHeight: 3.46” (8.79 cm) installed in B200S baseShipping Weight: 4.6 ozColor: IvoryOperatingTemperature Range: 32° F to 100° F (0° C to 38° C)Humidity:15 to 90% relative humidity(non-condensing)Air Velocity: 0 to 4,000 ft/min (0 to 20 m/sec)ElectricalOperating Voltage:15 to 32 VDCMaximum Standby:300µA at 24 VDC (no communication every 5 secondswith LED blink enabled)Maximum Alarm Current (LED on): 7.2 mA at 24 VDC Sensitivity SettingsSensitivity settings are programmable through zoneprogramming. Low:4% per foot (30.48 cm) of smoke. Used in equipment rooms, kitchens, paint shop.Medium: 3% per foot (30.48 cm) of smoke. Moderately clean environments: Used in hotel rooms, dorm rooms.High:2% per foot (30.48 cm) of smoke. Clean environments: Used in offices. Warning: After the CO cell has reached the end-of-life,the CO sensor no longer provides life safety protection.However, when the fire detector enters Photo, Thermal,Infrared (PTIR) mode, the following sensitivities apply:Level 1: 1% per foot (30.48 cm) of smoke. Very clean environments- Used in laboratories.Level 2: 2% per foot (30.48 cm) of smoke. Clean environments - offices.Level 5: 3% per foot (30.48 cm) of smoke. Moderately clean environments- Used in hotel rooms, dorm rooms.Level 6: Thermal alarm at 135° F (57° C). CO Monitoring UL Standard Reference - Alarm Thresholds are as follows:Note: Per UL Standard 2075, the IDP-FIRE-CO hasbeen tested to the sensitivity limits defined in ULStandard 2034. Ordering InformationIDP-FIRE-CO Multi-Criteria CO DetectorNote: Due to the unique nature of this detector, please consultyour Fire Alarm Control Panel Manufacturer forthe specific model and compatibility.AccessoriesB200S Intelligent Sensor Sounder BaseM02-04-01 Detector Test MagnetM02-09-01 Telescoping Test Magnet Parts Per Million Detector Response Time70 ± 5 ppm 60-240 min.150 ± 5 ppm 10-50 min.400 ± 10 ppm 4-15 min. Made in the U.S.A. This document is not intended to be used for installation purposes. We try to keep ourproduct information up-to-date and accurate. We cannot cover all specific applications oranticipate all requirements. All specifications are subject to change without notice. Formore information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610Phone: (800) 328-0103, Fax: (203) 484-7118. For Techincal Support, Please call 800-446-6444. www.farenhyt.com