HomeMy WebLinkAboutA15-0024 DATA SHEETS.pdfThe new VISTA-128FBP provides the ultimate protection of life and property. This UL Listed commercial fire and burglary control panel supports up to eight partitions and up to 128 zones/points using hardwired, wireless and V-Plex® addressable technologies. A diverse line of Honeywell initiating devices, notification circuits, communication devices, keypads, RF receivers and relays are also supported. The VISTA-128FBP has been designed to mount quickly and easily in an attack resistant cabinet, and is available in 12V and 24V models. • Eight hardwired zones standard, expandable to 120 V-Plex addressable points/zones or 128 wireless points/zones • Can control eight separate areas independently (8 partitions) • Supports commercial wireless fire and burglary devices • Stores up to 512 events • Accommodates 150 user codes and up to 250 access card holders using VISTAKEY® • Supports V-Plex addressable VISTAKEY access control (1 to 8 doors) • Two on-board notification (bell) circuits delivering 2.3A @ 12V • Automatic smoke detector sensitivity maintenance testing • Four-wire smoke reset using onboard J2 output trigger • Supports Dynamic Signaling for AlarmNet Communicators • Supports Internet and GSM alarm reporting* • Supports graphical user interfaces for burglary use • Supports 6160CR-2 multi-LED fire keypad • Listed to UL864 9th Edition • Upload/download via Ethernet* • Carbon monoxide (CO) zone support * When used with AlarmNet devices. FEATURES VISTA®-128FBP/V128FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL Now UL864 9th Edition Approved VISTA®-128FBP/V128FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ADDITIONAL FEATURES •Notification Appliance Circuits (two): - Programmable -Temporal code compliant - Individually silenceable •Programmable on-board auxiliary relay •False alarm reduction features: - Exit error logic - Exit delay reset - Cross zoning - Call waiting defeat - Recent close report •Supports commercial hardwired, addressable V-Plex®polling loop and wireless zones •Hardwired zones - Provides eight style B hardwired zones - EOLR supervised for Fire and UL burglary installations- Supports N.O. or N.C sensors - Individually assignable to any of eight partitions - Up to 16 two-wire smoke detectors each on zone one and two (32 total) - Up to 50 two-wire glassbreak detectors on zone eight • Patented addressable V-Plex polling loop technology -Supports 120 two-wire zones points -Global polling technology for faster processing -Supervised by panel - Zones individually assignable to partitions, notification circuit (bell) output or auxiliary relay -4,000 ft. capability without the use of shielded cable -Extender/Isolation bus modules -Eight zone - Class A and B expander module - Eight zone - Class B expander module -Single-zone supervised contact module • UL Listed wireless expansion - Supports up to 128 wireless zones/points -Supervised by control for check-in signals -Tamper protection for transmitters -Individually assignable up to eight partitions -Supports commercial wireless smoke detectors • Up to eight doors using VISTAKEY V-Plex Access Control • Event reporting • Local printer for event log printing • Communication -Phone line, GSM and IP communicator support -Panel operation during download Applications The VISTA-128FBP control is well suited for a variety of applications as an integrated fire and burglary control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments. Electrical • Primary power: 18VAC @ 72VA Honeywell No. 1451 • Control panel quiescent current draw: 300mA • Backup battery: - 12VDC, 12AH min to 34.4AH max - Lead acid battery (gel type) •Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Total 2.3A 12V •Aux. standby pwr: 12VDC, 1A max •Total power: 2.3A at 12VDC •Standby time: 24 hours with 1A standby load using 34.4AH battery •Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited. • Optional 24-volt kit Main Dialer •Line seize: Double Pole •Ringer equiv: 0.7B •Formats: ADEMCO®Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics Backup Communication •Dual phone line capability using 5140DLM module •AlarmNet®GSM, i-GSM and IP Communicators Cabinet Dimensions • 18" H x 14.5" W x 4.3"D Environmental • Storage temp: 14° F to 158° F (-10° C to 70° C) •Operating temp: 32° F to 122° F (0° C to 50° C) •Humidity: 85% RH •EMI: Meets or exceeds the following requirements: - FCC Part 15, Class B Device - FCC Part 68 - IEC EMC Directive Agency Listings • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault • UL611/1610 Grades A, AA, Central Station • UL365 Grades A, AA Police Connect • UL864/NFPA72 Local, Central Station and Remote Station • UL985 • Factory Mutual • California State Fire Marshal • MEA • CAN/ULC S304 – Central and Monitoring Station Burglar Alarm Unit • CAN/ULC S527 – Central Unit for Fire Alarm Systems • CAN/ULC S303 – Local Burglar Alarm Unit • CAN/ULC S525 – Audible Signal Appliances SPECIFICATIONS COMPATIBLE DEVICES L/VSTA128FBPD/D September 2012 © 2012 Honeywell International Inc. ORDERING V128FBP-9 Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V128FBP9-24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model VISTA®-128FBP/V128FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL Auxiliary Devices •6160CR-2 - Red Fire Keypad •6160 - Burglary Keypad •4204 - Relay Module, four form C contacts •4204CF - Two supervised output circuits •5881 Series RF receiver •5883H RF receiver •6220S - System printer used with 4100SM serial module Two-Wire Smoke Detectors Conventional •System Sensor •ESL •DSC Horn/Strobes •System Sensor •Wheelock •Gentex Manual Pull Stations • 5140MPS-1 • 5140MPS-2 V-Plex (Addressable) Devices • 4208U Universal Eight-zone Expansion Module • 4101SN Single Relay/Zone Module • 4208SNF Class A/B Expander Module • 4190SN Remote Point Module - two zones • 4193SN and 4193SNP Two-zone Expander Modules V-Plex Extender/Isolation Modules • 4297 Extender/Isolator Module • VSI Isolator Module V-Plex Smoke Detectors • 5193SD • 5193SDT V-Plex Passive Infrared Detectors • 998MX • IS2500SN • DT7500SN V-Plex (Addressable) Contacts • 4939SN-WH • 4944SN-WH • 4959SN V-Plex Glassbreak Detectors • FG1625SN Optional 24V Kit •Order number: V128FBP924KT Commercial Wireless Devices •5808W3 - Photoelectric Smoke/Heat Detector •5806W3 - Photoelectric Smoke Detector •5809 - Wireless Heat Detector •5817CB - Wireless Commercial Transmitter •5869 - Hold-Up Transmitter •5881ENHC - RF Receiver •5883H - RF Receiver Access Control •VISTAKEY®V-Plex (addressable) Access Control •VISTAKEY-SK Starter Kit •VISTAKEY-EX Expansion Kit Alarm Communications •7845i-ENT - Internet/Intranet Communicator •7845GSM - Digital Cellular Communicator •7845i-GSM - Internet and Digital Cellular Communicator •GSMCF/iGSMCF - Commercial Fire Communication Kits (when available) •IPGSM-DP Internet and Digital Cellular Communicator For more information: www.honeywell.com/security Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 1.800.467.5875 www.honeywell.com Product specifications subject to change. The Honeywell 5192 Series low profile, addressable V-Plex smoke detectors deliver state-of-the-art features and benefits in a cost-effective package. These detectors are designed to provide open area coverage and are compatible with Honeywell’s VISTA controls supporting V-Plex technology. An LED on the detector will blink periodically during normal conditions, remain on steady during alarm and cease to pulse if the chamber is out of acceptable sensitivity range. An extremely powerful feature available within the 5192 Series is the Automatic Maintenance Alert/Reporting capability – a feature normally found in today’s high end analog addressable systems. The detectors continually monitor their own sensitivity levels in addition to the basic normal and alarm conditions. These HIGH and LOW SENSITIVITY signals are communicated back to the control, via the V-Plex addressable loop, to indicate locally and at the central station that the detector may not be able to detect smoke or may false alarm. This feature works with VISTA-32FB, 128BP, 128FBP, 250BP, 250FBP, 40, 50P, 100-24 and FAP FA1600C, FA1660C and FA1700C. More important is the cost saving associated with Automatic Maintenance Reporting. The feature is an approved alternate to NFPA 72 field sensitivity calibration testing that require external test meters. This eliminates the need to schedule inspections to determine detector sensitivity/viability. Another important benefit of these V-Plex (addressable) smoke detectors is their ability to operate on existing wiring. There is no need to run special twisted pair, data grade or shielded wires, providing you with the right choice for all your retrofit applications. That equates to cost savings in time and materials! • Low profile design • V-Plex addressable loop device • Automatic maintenance reporting • Available with integral heat sensor • Simple 2 wire installation • DIP switch or serial number programmable • Lines on existing or conventional wiring FEATURES The 5192 Series smoke detectors are designed to provide open area coverage and are well suited for most fire detection applications. These smoke detectors are compatible with all Honeywell VISTA Fire and Burglary controls that support V-Plex addressable loop technology. These agency listed alarm initiating devices support most commercial and residential applications.They are suited for use in museums, hospitals, day care centers, retail stores, strip malls, schools, libraries, fast food chains, medical or professional office suites and in factory and warehouse environments. APPLICATIONS 5192SD/5192SDT V-PLEX®SMOKE DETECTOR L/5192/D May 2009 © 2009 Honeywell International Inc. ORDERING 5192SD Addressable Photoelectric Smoke Detector 5192SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor SPECIFICATIONS 5192SD/5192SDT V-PLEX™ SMOKE DETECTOR Installation The 5192 Series smoke detectors are supplied with a convenient mounting bracket that allows the detector to be mounted to a variety of electrical junction boxes. A removable terminal block, that accepts 14 to 22 gauge wire to provide easy wiring connections. The detectors are designed to meet all applicable requirements for UL Commercial and Residential Fire installations as well as NFPA 72 requirements when installed in compliance with the National Electric Code and approved/listed control panels. CompatibilIty These smoke detectors are compatible with all VISTA control panels that support V-Plex (addressable) polling loop technology. The detectors support DIP switch or serial number addressing. DIP switch configuration are compatible with 5140XM, VISTA-40, and VISTA-50P controls. Serial number addressing is supported on VISTA-32FB, 128BP, 128FBP, 250BP, 250FBP, 100-24 and FAP FA1600C, FA1660C and FA1700C controls. (Refer to control panel and smoke detector installation instructions for details.) Automatic Maintenance Reporting Compatibility The automatic maintenance feature is compatible with the following control panels: – VISTA-32FB – VISTA-128BP – VISTA-128FBP – VISTA-250BP – VISTA-250FBP – FA1600C – FA1660C – FA1700C The automatic maintenance may be disabled for all other controls that do not support this feature. Refer to control panel and smoke detector Installation Instructions for details. Electrical: • System voltage range: 7-14 V Standby current (maximum @ 12V): – LED off: 1.2mA – LED on: 2.8mA Mechanical: • Diameter: 5.5 inches (140mm) (including mounting bracket) • Height: 1.7 inches (43mm) (including mounting bracket) • Weight: 5.3 ounces (150 grams) Environmental: • Installation temperature range: 32° to 100°F (0° to 38°C) • Installation humidity range: 10% to 93% RH, non-condensing • Heat sensor (5192SDT only): 135°F fixed temperature electronic thermistor • EMI: Meets or exceeds the following requirements: – FCC Part 15, Class B Device – IEC EMC Directive Agency Listings • UL268 Commercial System Smoke Detector • Meets UL 217 Requirements for ResidentialVISTA SERIES UL LISTEDCOMPATIBLE CONTROL PANEL REMOVABLE TERMINAL BLOCK DIP SWITCH Wiring diagram for 5192SD/SDT smoke detector For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 www.honeywell.com Agency Listings 5600 Series Mechanical Heat Detectors System Sensor’s 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Features Multiple configurations for installations: – Single- and dual-circuit models – Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. Plain housing for residential installations (Model 5601P) Easy-to-use terminal screws A broad range of back box mounting options: – Single gang – 3.5˝ and 4˝ Octagonal – 4˝ square with square to round plaster ring Reversible mounting bracket • • • • • Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit models are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back boxes. And these models accommodate four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. S2101 3016008 199-03-E 7270-1209:227 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2006 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0351-002 • 11/06 • #1676 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number _________, listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 3½-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14–22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601P, 5602, 5621, and 5622 only) Mounting 3½-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact Ratings 6–125VAC / 3A 6–28VDC / 1A 125VDC / 0.3A 250VDC / 0.1A Input Terminals 14–22 AWG Ordering Information Model Circuit Identification Method on Exterior Temperature Rating Activation UL Protected Spacing – 10 Foot Ceiling* 5601P Single None 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5602 Single Lettering 194°F (90°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5603 Single Lettering 135°F (57°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5604 Single Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5621 Dual Lettering 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5624 Dual Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 5601P FX/ROR194°F/9 0 °C5602, 5622 FX135°F/5 7 °C5603, 5623 FX194°F/90 °C 5604, 5624 FX/ROR135°F/5 7 °C5621 Agency Listings CO1224T Carbon Monoxide Detector with RealTest™ Technology The System Sensor CO1224T CO detector provides early warning by using electrochemical sensing technology to measure carbon monoxide levels in the air. Features RealTest• ™ technology allows installer to test detector with CO gas Full compliance with UL 2075• A code required trouble relay• Wiring supervision with SEMS terminals• A six year end-of-life timer• 12/24 VDC• A current draw of 20mA in standby and 40mA in alarm• Versatile mounting for wall and ceiling• Electrochemical sensing technology• With RealTest™ technology, the CO gas sensing cell of the CO1224T CO detector can be tested using a carbon monoxide gas agent. Simply hold the test button for two seconds. After the alarm cycle (temp 4) the green LED will flash about once per second, indicating that the detector is ready to accept CO for testing. Spray a small amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. If dangerous amounts of carbon monoxide is detected, the CO1224T detector will alert residents by sounding and flashing a temp-4 signal alarm. Protection is guaranteed 24/7 by a central station, regardless of whether residents are away from home, sleeping or already suffering from the effects of CO. This specific device is designed for system operation. The detector is fully listed to UL 2075. It offers a code required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station. It also uses SEMS-type terminal Philips head screws to provide a quicker and more positive wiring connection and code required wiring supervision. The CO1224T detector offers a low current draw, allowing more devices to be connected to the panel without having to purchase a more expensive panel or an extra power supply. The CO1224T model will operate on most industry security and fire alarm control panels because it is is a 12/24 VDC detector. 2075 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2008 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.A05-0437-000 • 8/08 • #1953 Ordering Information Part No.Description CO1224T 12/24 volt, 4-wire system-monitored carbon monoxide detector with RealTest™ Technology CO1224T Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide detector shall be a System Sensor model number CO1224T, listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors. The detector shall be equipped with a sounder and a trouble relay. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual color LED indication, which blinks to indicate normal standby, alarm, or end-of-life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end-of-life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size Length: 5.1 in, Width: 3.3 in, Height: 1.3 in Approximate Weight 7 oz Operating Temperature Range 32°F to 104° F (0°C to 40° C) Operating Humidity Range 22 to 90% RH Input Terminals 14 to 22 AWG Mounting Single-gang back box; surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal (standby)Blink 1 per minute —— Alarm —Blink in temp 4 pattern Sound in temp 4 pattern RealTest™ Feature: The System Sensor CO1224T carbon monoxide detector with RealTest™ can evaluate the functionality of the CO sensing cell using canned test agent. NOTE: Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an installation. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes (except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-life Timer: After the detector’s internal sensor has reached the end of its life, a trouble signal will be sent to the panel. This will indicate that it is time to replace the detector. An electrochemical carbon monoxide detector lifespan is approximately six years, and the detector must be replaced by the date marked on the inside of the product. 1.2.3. Push and hold the Test/Hush button for two seconds to enter RealTest mode. The green LED will flash once every second to indicate RealTest mode has started. Spray canned CO agent into the detector. Verify CO sensing at the control panel. The detector will automatically exit RealTest alarm mode after about 20-60 seconds. Agency Listings Mini-Horns The SpectrAlert® Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. Features • 12 and 24V operation • High and low volume settings • Temporal and non-temporal tones • Mounts to single gang back box • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series Mini-Alert™ sounders • Listing for ceiling or wall mounting The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini-horns offer high and low volume settings, and temporal or non-temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini-horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply. They are listed to Underwriter’s Laboratories Standard UL 464 for fire protective signaling systems. S4011 3028007 CS1099 7135-1653:196 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS01500 • 3/12 Ordering Information Part No.Description MHR Mini-Horn, Red MHW Mini-Horn, White SpectrAlert® Advance Mini-Horn Specifications Architectural/Engineering Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box. Mini-horn shall be listed to Underwriter’s Laboratories Standard UL464 for fire protective signaling systems. Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. When used with the Sync•Circuit™ Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.6˝L × 2.9˝W × .45˝D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F (0°C to 49°C) Mounting Surface: deep single-gang back box (23/4˝ deep) Flush: Standard 4˝ × 4˝ back box with single gang mud ring, which allows sufficient clearance for conduit entrance. Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8–33 Operating Voltage with MDL 9–33 UL Sound Output and Current Draw Data Sounder Output (dBA) Switch Setting Pattern Output Level 8–17.5 VDC 8–17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16–33 VDC 16–33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- temporal High 72 71 75 74 80 79 4 Non- temporal Low 70 69 73 72 78 77 Sounder Current Draw (mA RMS) Switch Position Sound Pattern Volume 8–17.5 Volts 16–33 Volts DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Agency Listings Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and three volume selections • Universal mounting plate for wall and ceiling units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with existing SpectrAlert products • Compatible with MDL sync module The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Selectable-Output Horns, Strobes, and Horn Strobes SpectrAlert® Advance selectable-output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. MEA452-05-E3023572 7125-1653:186 (indoor strobes) 7125-1653:188 (horn strobes, chime strobes)7135-1653:189 (horns, chimes) S4011 (chimes, horn strobes, horns) S5512 (strobes) A05-0395-007 SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8˝ diameter × 2.5˝ high (173 mm diameter × 64 mm high) Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 2.5˝ D (142 mm L × 119 mm W × 64 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.3˝ D (142 mm L × 119 mm W × 33 mm D) Wall-Mount Back Box Skirt Dimensions (BBS-2, BBSW-2)5.9˝ L × 5.0˝ W × 2.2˝ D (151 mm L × 128 mm W × 56 mm D) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2)7.1˝ diameter × 2.2˝ high (180 mm diameter × 57 mm high) Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS, TRW-HS)5.7˝ L × 4.8˝ W × 0.35˝ D (145 mm L × 122 mm W × 9 mm D) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS, TRCW-HS)6.9˝ diameter × 0.35˝ high (175 mm diameter × 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395-007 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7†Coded High 82 82 88 88 93 92 101 101 8†Coded Medium 78 78 85 85 90 90 97 98 9†Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobe. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 UL Current Draw Data Horn Tones and Sound Output Data UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2009 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.A05-0395-007 • 4/09 • #2132 SpectrAlert Advance Dimensions Model Description Wall Horn Strobes P2R*†2-Wire Horn Strobe, Standard cd‡, Red P2RH*2-Wire Horn Strobe, High cd, Red P2W*2-Wire Horn Strobe, Standard cd, White P2WH*2-Wire Horn Strobe, High cd, White P4R*4-Wire Horn Strobe, Standard cd, Red P4RH 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes SR*†Strobe, Standard cd, Red SRH*†Strobe, High cd, Red SW*Strobe, Standard cd, White SWH*Strobe, High cd, White Ceiling Horn Strobes PC2R*2-Wire Horn Strobe, Standard cd, Red PC2RH 2-Wire Horn Strobe, High cd, Red PC2W*†2-Wire Horn Strobe, Standard cd, White PC2WH*2-Wire Horn Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red PC4RH 4-Wire Horn Strobe, High cd, Red PC4W 4-Wire Horn Strobe, Standard cd, White SpectrAlert Advance Ordering Information Notes: * Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., P2R-P. † Add “-SP” to model number for “FUEGO” marking on cover, e.g., P2R-SP. ‡ “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. 4.7˝ 5.6˝ 6.8˝Dia. 2.5˝ 2.5˝ 2.23˝5.05˝ 5.98˝ 7.1˝Dia. 2.25˝ 5.1˝ 2.0˝ 5.7˝ 7.1˝Dia. 2.0˝ Wall-mount horn strobes Ceiling-mount horn strobes Wall back box skirt Ceiling back box skirt Model Description Ceiling Strobes SCR Strobe, Standard cd, Red SCRH Strobe, High cd, Red SCW*Strobe, Standard cd, White SCWH Strobe, High cd, White Horns HR Horn, Red HW Horn, White Accessories BBS-2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White TR-HS Trim Ring, Wall, Red TRW-HS Trim Ring, Wall White TRC-HS Trim Ring, Ceiling, Red TRCW-HS Trim Ring, Ceiling, White