RECESSED CAN LIGHT
(wet location)
RECESSED CAN LIGHT
(sloped ceiling fixture)
RECESSED CAN LIGHT
(directional spot)
CEILING MOUNTED CHANDELIER
RECESSED CAN LIGHT
WALL MOUNTED SCONCE FIXTURE
CEILING FAN
UNDERCABINET LIGHT
FLUORESCENT CLOSET LIGHT
(JS=JAMB SWITCH)
CEILING EXHAUST FAN
STEP LIGHT
1/2 HOT DUPLEX OUTLET
ELECTRICAL / LIGHTING LEGEND
DUPLEX OUTLET RECEPTACLE
SD 3 SS
SINGLE SWITCH
3-WAY SWITCH
DIMMER SWITCH
CEILING MOUNTED SCONCE OR PENDANT
F
120V UL 217 SMOKE /
UL 2034 CARBON MONOXIDE COMBO
M MOTION SENSOR LIGHT
CEILING MOUNT
RECESSED FLOOR
DUPLEX OUTLET
UP WALL UPLIGHTING
SF FAN CONTROLS
S/C
FLUORESCENT STRIP LIGHT
GFCI DUPLEX OUTLET
PHONE/DATA OUTLET
CABLE/COAX OUTLET
OTHER NOTES
* PROVIDE DOOR BELL CHIME AT EACH LEVEL.
* PROVIDE POWER AT ALL HEAT TAPE AND FUTURE
HEAT TAPELOCATIONS. REVIEW LOCATIONS WITH
GENERAL CONTRACTOR.
* ALL SWITCHES THAT CONTROL INTERIOR LIGHTS (NOT
IN CLOSETS) SHOULD BE DIMMER CONTROLLED
WHERE POSSIBLE AND PRACTICAL.
*ALL OUTLETS AND SWITCHES SHOULD BE DECORA
STYLE WITH CONCEALED SCREWS.
* ALL IGNITION POINTS OF GAS FIRED MECH. EQUIP.
SHALL BE 18" A.F.F. OF GARAGE (WHEN MECH IS
LOCATED ADJACENT OR WITHIN THE GARAGE).
LIGHTING NOTES
GENERAL CONTRACTOR TO MEET 2015 IRC
REQUIREMENTS
SECTION N1104.1 LIGHTING EQUIPMENT:
A MINIMUM OF 92 PERCENT OF THE LAMPS IN
PERMANENTLY INSTALLED LIGHTING FIXTURES
SHALL BE HIGH-EFFICACY LAMPS.
GFCI OUTLET
PROVIDE AT ALL BATHS, KITCHENS,
LAUNDRY, DISHWASHERS GARAGES,
MECH. ROOMS.
ARC-FAULT CIRCUIT INTERRUPTER
AFCI PROTECTION IS REQUIRED ON ALL BRANCH
CIRCUITS SUPPLYING OUTLETS OR DEVICES
INSTALLED IN DWELLING UNIT KITCHENS, FAMILY
ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS,
LIBRARIES, DENS, BEDROOMS, SUNROOMS,
RECREATION ROOMS, CLOSETS, HALLWAYS,
LAUNDRY AREAS, AND SIMILAR ROOMS AND AREAS.
OUTDOOR RECEPTACLES ARE 125-VOLT,
SINGLE PHASE, 15 AND 20 AMP AND SHALL BE
GFCI. OUTLETS ARE TO HAVE A COVER AND
WEATHERPROOF WHILE IN USE OT NOT
GFI
DECK SOFFIT
DECK SOFFIT
STEEL BEAM
STEEL BEAM
STEEL BEAM
F
F
GFCI
WP
F
F
GFCI
WP
F
WP
F
SF SD
SF SD SD
SF SD
S
S SF
SD
SF SD S
S3DS3D S
SD3
S3DS
UP TO
SWITCH
S 3
S3 SS
SD
SF SD SD3
SD3
S
S
3
S
S S S
3
S
UP TO
SWITCH 3 SGARAGE
DOOR
MOTOR
GARAGE
DOOR
MOTOR
3SS
S
S S
S S S
S/C
S/C
S/C
+42"
+42"
GFI
WP
GFI
WP
S
GFI
GFCI
GFI
+42"
+42
1
2
2
3
4
5
6
7
8
9
10
11
12
12
A
A
B
B
C
D F
F J L G N
H
S/C
S/C
GFI
WP
970.328.5151
OFFICE
PO Box 1587,
Eagle, CO 81631
www.martinmanleyarchitects.com
Project
number
Date
REVISIONS
8/29/2017
4:18:28 PM
A7.1
LOWER
CEILING
PLAN
1719
1709 GENEVA
DUPLEX PERMIT
SET
8-4-17
DAVE
HILB
1709
GENEVA
DRIVE,
VAIL, CO
MATTERHORN
VILLAGE
FILING 1, LOT 4 NORTH
1/4" = 1'-0"
1 1. LOWER LVL - REFLECTED CLNG PLAN
PERMIT SET DATE: 8-4-17 1
No. Description Date
1 Permit Revisions 1 8-29-17
09/22/17