Loading...
HomeMy WebLinkAboutB17-0305_A7.2_1506117650.pdfWP F RECESSED CAN LIGHT (wet location) RECESSED CAN LIGHT (sloped ceiling fixture) RECESSED CAN LIGHT (directional spot) CEILING MOUNTED CHANDELIER RECESSED CAN LIGHT WALL MOUNTED SCONCE FIXTURE CEILING FAN UNDERCABINET LIGHT FLUORESCENT CLOSET LIGHT (JS=JAMB SWITCH) CEILING EXHAUST FAN STEP LIGHT 1/2 HOT DUPLEX OUTLET ELECTRICAL / LIGHTING LEGEND DUPLEX OUTLET RECEPTACLE SD 3 SS SINGLE SWITCH 3-WAY SWITCH DIMMER SWITCH CEILING MOUNTED SCONCE OR PENDANT F 120V UL 217 SMOKE / UL 2034 CARBON MONOXIDE COMBO M MOTION SENSOR LIGHT CEILING MOUNT RECESSED FLOOR DUPLEX OUTLET UP WALL UPLIGHTING SF FAN CONTROLS S/C FLUORESCENT STRIP LIGHT GFCI DUPLEX OUTLET PHONE/DATA OUTLET CABLE/COAX OUTLET OTHER NOTES * PROVIDE DOOR BELL CHIME AT EACH LEVEL. * PROVIDE POWER AT ALL HEAT TAPE AND FUTURE HEAT TAPELOCATIONS. REVIEW LOCATIONS WITH GENERAL CONTRACTOR. * ALL SWITCHES THAT CONTROL INTERIOR LIGHTS (NOT IN CLOSETS) SHOULD BE DIMMER CONTROLLED WHERE POSSIBLE AND PRACTICAL. *ALL OUTLETS AND SWITCHES SHOULD BE DECORA STYLE WITH CONCEALED SCREWS. * ALL IGNITION POINTS OF GAS FIRED MECH. EQUIP. SHALL BE 18" A.F.F. OF GARAGE (WHEN MECH IS LOCATED ADJACENT OR WITHIN THE GARAGE). LIGHTING NOTES GENERAL CONTRACTOR TO MEET 2015 IRC REQUIREMENTS SECTION N1104.1 LIGHTING EQUIPMENT: A MINIMUM OF 92 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS. GFCI OUTLET PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY, DISHWASHERS GARAGES, MECH. ROOMS. ARC-FAULT CIRCUIT INTERRUPTER AFCI PROTECTION IS REQUIRED ON ALL BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, AND SIMILAR ROOMS AND AREAS. OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15 AND 20 AMP AND SHALL BE GFCI. OUTLETS ARE TO HAVE A COVER AND WEATHERPROOF WHILE IN USE OT NOT GFI DROPPED WRAPPED BEAM STEEL BEAM STEEL BEAM FLAT DROPPED CEILING ABOVE STEEL BEAM STEEL BEAM 2" / 12" SLOPED DROPPED CEILING DROPPED CEILING DROPPED CEILING DROPPED CEILING 1 1/2" / 12" 1 1/2" / 12" SLOPED DROPPED CEILING SLOPED DROPPED CEILING 2" / 12" DROPPED SLOPING CEILING DROPPED CEILING EXTERIOR SOFFIT WP F FIXTURES IN SOFFIT F F F F F WP WP F F F F F LIGHTS IN SLOPED DECK ROOF HOOD SF S S S SD SD3 SD SD3 SD3 S SD3 D3 SD3SD SF SD SD SD3 SS T SD3DOWN TO FIX. SSD3D3 SF SD SD SF S S S SF SF SD SD UP TO FIXT. UP TO FIXT. SF SF SD SD SDS S SF SD SD S SF SD SD S SF SD SSD SD3D3SD3SD SD3 SD S SD3SD3 DN TO FIXT. UP TO SWITCH SD3S SD3 S D SD3SD3 SD3 SSD3 3 S3 S/C S/C S/C FLOOR GFI GFI +42" +42" +42" GFI +42" GFI +42" GFI +42" WP GFI +42" S GFI GFI +42" GFI +42" GFI +42" +42" GFI PROVIDE OUTLET FOR ISLAND +42" DW DW WP 1 2 2 3 4 5 6 7 7 8 9 10 11 12 12 A A B B C D D E E F J L G N M K K H S/C S/C GFI WP WP FLOOR FLOOR FLOOR FLOOR FLOOR 2 2 FLOOR FLOOR FLOOR 2 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 9/11/2017 3:28:17 PM A7.2 MAIN CEILING PLAN 1719 1709 GENEVA DUPLEX PERMIT SET 8-4-17 DAVE HILB 1709 GENEVA DRIVE, VAIL, CO MATTERHORN VILLAGE FILING 1, LOT 4 NORTH 1/4" = 1'-0" 1 2. MAIN LEVEL PERMIT SET DATE: 8-4-17 1 No. Description Date 1 Permit Revisions 1 8-29-17 2 Permit Revsions 2 9-11-17 09/22/17