HomeMy WebLinkAboutB17-0305_A7.3_1506117650.pdfWP
F
RECESSED CAN LIGHT
(wet location)
RECESSED CAN LIGHT
(sloped ceiling fixture)
RECESSED CAN LIGHT
(directional spot)
CEILING MOUNTED CHANDELIER
RECESSED CAN LIGHT
WALL MOUNTED SCONCE FIXTURE
CEILING FAN
UNDERCABINET LIGHT
FLUORESCENT CLOSET LIGHT
(JS=JAMB SWITCH)
CEILING EXHAUST FAN
STEP LIGHT
1/2 HOT DUPLEX OUTLET
ELECTRICAL / LIGHTING LEGEND
DUPLEX OUTLET RECEPTACLE
SD 3 SS
SINGLE SWITCH
3-WAY SWITCH
DIMMER SWITCH
CEILING MOUNTED SCONCE OR PENDANT
F
120V UL 217 SMOKE /
UL 2034 CARBON MONOXIDE COMBO
M MOTION SENSOR LIGHT
CEILING MOUNT
RECESSED FLOOR
DUPLEX OUTLET
UP WALL UPLIGHTING
SF FAN CONTROLS
S/C
FLUORESCENT STRIP LIGHT
GFCI DUPLEX OUTLET
PHONE/DATA OUTLET
CABLE/COAX OUTLET
OTHER NOTES
* PROVIDE DOOR BELL CHIME AT EACH LEVEL.
* PROVIDE POWER AT ALL HEAT TAPE AND FUTURE
HEAT TAPELOCATIONS. REVIEW LOCATIONS WITH
GENERAL CONTRACTOR.
* ALL SWITCHES THAT CONTROL INTERIOR LIGHTS (NOT
IN CLOSETS) SHOULD BE DIMMER CONTROLLED
WHERE POSSIBLE AND PRACTICAL.
*ALL OUTLETS AND SWITCHES SHOULD BE DECORA
STYLE WITH CONCEALED SCREWS.
* ALL IGNITION POINTS OF GAS FIRED MECH. EQUIP.
SHALL BE 18" A.F.F. OF GARAGE (WHEN MECH IS
LOCATED ADJACENT OR WITHIN THE GARAGE).
LIGHTING NOTES
GENERAL CONTRACTOR TO MEET 2015 IRC
REQUIREMENTS
SECTION N1104.1 LIGHTING EQUIPMENT:
A MINIMUM OF 92 PERCENT OF THE LAMPS IN
PERMANENTLY INSTALLED LIGHTING FIXTURES
SHALL BE HIGH-EFFICACY LAMPS.
GFCI OUTLET
PROVIDE AT ALL BATHS, KITCHENS,
LAUNDRY, DISHWASHERS GARAGES,
MECH. ROOMS.
ARC-FAULT CIRCUIT INTERRUPTER
AFCI PROTECTION IS REQUIRED ON ALL BRANCH
CIRCUITS SUPPLYING OUTLETS OR DEVICES
INSTALLED IN DWELLING UNIT KITCHENS, FAMILY
ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS,
LIBRARIES, DENS, BEDROOMS, SUNROOMS,
RECREATION ROOMS, CLOSETS, HALLWAYS,
LAUNDRY AREAS, AND SIMILAR ROOMS AND AREAS.
OUTDOOR RECEPTACLES ARE 125-VOLT,
SINGLE PHASE, 15 AND 20 AMP AND SHALL BE
GFCI. OUTLETS ARE TO HAVE A COVER AND
WEATHERPROOF WHILE IN USE OT NOT
GFI
FLAT DROPPED
CEILING ABOVE
2" / 12"
2" / 12"
2" / 12"
VOID SPACE
DROPPED
SLOPED
CEILING DROPPED
SLOPED
CEILING
DROPPED
SLOPED
CEILING
2" / 12"
2" / 12"
2" / 12"
DROPPED
SLOPED
CEILING
DROPPED
SLOPED
CEILING
DROPPED
SLOPED
CEILING
F
F F
F
F
F
WP
WP
SEE MAIN LEVEL
CEILING PLAN FOR
LIGHTING IN THIS AREA
F
WP
SSF SD
SF
SD S
SF
S DOWN TO
SWITCH
SD3
DOWN TO
SWITCH
SFSD
S
SD
S
SFSDSD
S
SD SF
DOWN TO
SWITCH S S
S/C
S/C
S/C
S/C
GFI
+42"
SD S
GFI
+42"
GFI
+42"
SFSD
1
2
3
4
5
6
7
8
10
B
B
C
D
E
E G K
S/C
2
2
2
970.328.5151
OFFICE
PO Box 1587,
Eagle, CO 81631
www.martinmanleyarchitects.com
Project
number
Date
REVISIONS
9/11/2017
3:28:17 PM
A7.3
UPPER
CEILING
PLAN
1719
1709 GENEVA
DUPLEX
PERMIT
SET
8-4-17
DAVE
HILB
1709
GENEVA
DRIVE,
VAIL, CO
MATTERHORN
VILLAGE
FILING 1, LOT 4 NORTH
1/4" = 1'-0"
1
3. UPPER LEVEL PERMIT SET DATE: 8-4-17 1
No. Description Date
1 Permit Revisions 1 8-29-17
2 Permit Revsions 2 9-11-17
09/22/17