HomeMy WebLinkAboutE16-0036 plans approved.pdf D P.1.* OA 2016 Town of Vail ,..._i\ e -\ - � Q �OWNiTi� f a ) ,a ) c tiss�� 5 U 0)2— / GENERAL NOTES: SHEET DETAIL NOTES: T/ - '�a/0 O NORTH STAIR I.ALL DUCTWORK DIMENSIONS ARE SHOWN INSIDE TO INSIDE. O INSTALLUTIO&AS-3 PER SHELL FOR FUTURE REINSTALLATION C C 2 O r INSTRUCTIONS AS CORE&SHELL FOR FUTURE UPGRADE.PROVIDE Q m O>O 2.ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1"LINER AUXILIARY PAN UNDER THE FAN COIL,RE:FAN COIL UNIT DETAIL ON L Lbw 2-10 /\ 5 m UNLESS OTHERWISE NOTED.ALL OUTSIDE AIR INTAKE AND ROUND M)2.ROUTE 3/4"CD FROM THE PAN TO THE NEAREST D.F.U.. /I L�I/y�-/jxxfr.�.7 y I I Culli)V� Q 0. DUCTWORK SHALL BE WRAPPED WITH 1.5"THICK INSULATION UNLESS CONNECT TO IT VIA AIR GAP. a` 61 O VI�-�( x E0 OTHERWISE NOTED. 8 \ Q7 2).-TS/ N 1<V 2 TERMINATE RESTROOM EXHAUST MIN.3'AWAY FROM NATURAL AIR 1 P { "L C y.00 LL 3.ALL ROUND DUCT CONNECTIONS TO ROUND DUCTWORK SHALL BE O INTAKE TO THE BUILDING,3'AWAY FROM PROPERTY LINE.10'AWAY 1 I I /! • I E1N�' ^ CODE co U- (0 CONICAL TEES. FROM ANY MECHANICAL AIR INTAKE TO THE BUILDING. 7-XFER B ala AP I5 • O/R a) •J Q••t ry 4.ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES. 3O CONTINUE EXHAUST DUCT UNDER 14x8 SUPPLY&RETURN DUCTS TO 4112x14 17 e -zi0 kak ,g /• O M P L I A ' r F � °°_ LO (3)EF-1. _� ■ II//JI l 010 co OD(0 S ALL DUCTWORK SHALL BE RUN TIGHT TO UNDERSIDE OF STEEL DECKING © _0 UN-3 I - / 0Ct C C IJJ • OR STEEL STRUCTURE WHERE IT EXISTS UNLESS OTHERWISE NOTED. 4 ROUTE 14x8 RETURN DUCTWORK DOWN AND CONTINUE UNDER FGS I__I__1=1• AA. 3 e e e +-II�1i3. a y ] n O AND UNDER 14x8 SUPPLY DUCTWORK. _• ® II 18 D a 1 e• •(� '� J/ W 5 JI=O 6.ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL -"• - ® ,Jr= \V / W.L..,u)W INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY. SO CONNECT IT 0 RETURN TO 14+8 MAIN RETURN UNDER 14+8 SUPPLY. I '"" 0 ®©®m %" , 4 7.COORDINATE ALL ACCESS PANEL LOCATIONS WITH THE ARCHITECT. fiO ROUTE 6"0 EXHAUST UNDER 14x8 SUPPLY&RETURN DUCTWORK TO • J� L - MI� f,- 7 Y '�.�` V U tom) .__- -_J I lam.__. ����0©©© .-_ THE SIDE WALL TERMINATION. I I Ow ]` L =_N:.•, ( - _ -_I co 0 L O�Q O ROUTE DUCTWORK IN THE JOIST BAY. [11 - ,4 - P�-' -�� —��+ej -� 1 L y C Oi y _ �r ACCESS PANEL :inn I z V Q Ci +530 CFM , 3 ROUTE 14+8 SUPPLY AS HIGH AS POSSIBLE TO ALLOW BRANCHES ~- II- I\-7 I ;, ir I�1 COME UP AND INTO JOIST BAYS.ROUTE 14x8 RETURN DUCTWORK A 3305 Y 1•; "- . L co UNDERNEATH 14x8 SUPPLY(NOT SHOWN FOR CLARITY), I STUDIO 16.0 19 _ `7I m 9O CONNECT RETURN DIFFUSER INTO THE 14x8 RETURN DUCTWORK STUDIO V � v e Li ��1 �'. a t UNDERNEATH 1426 SUPPLY. F. 229 -360CFM 10 INSTALLFC4&FCSPERMANUFACTURERSLINSTALLATION -' KITCHEN I )i �' INSTRUCTIONS IN THE ATTIC SPACE INSTALL AUXILIARY PAN UNDER 61 I �--- - CRE( W EACH FAN COIL.RE'FAN COIL UNIT DETAIL ON M1.2 ROUTE 3/4"CD I L )_I I µPD r 8 EXISTING DOWN TO THE NEAREST D.F.U.AND CONNECT TOR VIA AIR GAP. Wti.;12 - I_C_..._.J I4 LIVING . _'p`ONV H,�yy,•+,70 CFM 11 THISEF-1SHALLBE INSTALLEDIN THEATTIC AND INTERLOCKED WITH �"'� ----� J'TORA(j C---- - I��-J� "v`4 ' C;_-150 C8FM0 ' g.0 REVERSE ACTING TSTAT AND HUMIDISTAT, �l) i _ __- 1 -Ly_� I sl5 4?12 INSTALL TRANSFER DIFFUSER WITH AT LEAST d'LONG 8"0 DUCT AND _ T- TO FG22005 01 z 1.� 400-S A �SI, {fir.11)ELBOW FOR SOUND ATTENUATION. B / 14x4 1�11 // ' 16 fi O - C`�IOM1A.�"v 13 INSTALL CU•I IN THIS AREA,PROVIDE SOUND&VIBRATION ISOLATING /� l_.. _._.._ .- 530R 1 •-- 0 0 ER0•�\\ 12 -1 ■ "!----"�"--'----- ----- '- --- '- _ g•0 PADS,PROVIDE REMOVABLE LOUVERS ON ALL ROUTE ..-i-•'",--, Oi6z10 El®�I TO FC4 l� -� j 770 CFM - REFRIGERATION PIPING TO CH-1.USE THE SHORTEST ROUTE -� -4"" k S� L� I X C POSSIBLE,COORDINATE LONG LINE PIPING REQUIREMENTS WITH 23 1 -••- + F 24 O MANUFACTURER. li,,,,10,„rd,0 B 940-8 HALL .. 1 I I �-' - ^' Aso cFMO VUES7�J 1�\i1{ I ` \ V 8"0 74 ROUTE 3'BOILER VENT 8 COMBUSTION AIR INTAKE UP AND 226 030x12 I I I ,_.1.11.1— 1 � � TERMINATE SIDE WALL(FACING SOUTH)36"ABOVE THE ROOF(NOT L7 "'I.'.ERV-1 DIAGRAM SHOWN). IP.!i 6 YB10111 - IQ 15 TZ.. H=10"III U __22x6 O SCALE:NONE EXHAUST AND UP NK TOTHESI WALL(NOT AHO E FOR I I & . J\ /I L� 7 CLARITY)AND UP AND TERMINATE SIDEWALL 36'ABOVE THE ROOF. ) I J I \ / 1 ` p L fIfH. ACCESS PANEL _1L_JLifili 11 Z 16 THIS UNIT SHALL BE SUPPLIED&INSTALLED BY E.C.,HERE SHOWN1■I^f-__ L �' ,0 18x10 0 FOR REFERENCE ONLY.RE:ELECTRICAL PLANS. 10'0 10^0 0 T �' e - r--, ACCESS PANEL O O +325 CFM PROVIDE MOTORIZED DAMPER(NOT SHOWN FOR CLARITY). IMIN 1 O IM ® ©gp-/y O 24^+ 'A 325 CFM INTERLOCK MOTORIZED DAMPER WITH EF-2.OPEN DAMPER WHEN _-" { I - -305 C © / EF-2 IS ON.UPON A LOSS OF POWER,THIS DAMPER SHALL CLOSE. _� 0 0 6x6 K\` 1 0 . 0 Lo -305 CFM 0 ADJUST BLADES TOWARDS WINDOWS AND UP TOWARDS THE CEILING. TB DROO I I— r 10 0 CO DO NOT SET THE BLADES DIRECTLY FORWARD. HALL O L__..Z.,1 r- V/ ®' I -575 CFM 23•-4"0 233 1' r:�.. © CO e 0 COORDINATE DUCT ROUTING WITH PLUMBING AND HVAC PIPING IN TO FC-5 e O LENGTH OF THE BARRIER 2'FROM THE EDGE OF THE DIFFUSERS OR �r 61 m 61 5 1� 010x6 O --..,...17 ill( 2 o 120,50 THIS LOCATION. . . ___.._. /// / v�• SOS - ....__ ^'23 _,-. '- LENGTH (E)16z12 1 20 INSTALL SOUND ATTENUATING BARRIER INSIDE THE DUCTWORK,MIN. 1 I tots,. V AS INDICATED. O LB Q J 5 0 21 IF THE CEILING IN THIS CLOSET AND BEDROOMS PERMIT,EXTEND THIS �' NI ,4z6O 74x80 'I- d"0-- 1-..- ..T. WA' +575 CFM EXISTING DUCTWORK AS SOUTH AS POSSIBLE. ,� �r s_9.0 O Q Z I— 22 OFD THE DRYER IN FIELD.EENT TO THE DRYER.VERIFY EXACT LOCATION '00D-R+4 O OB 105 1 O EL w u) 1 0 TERMINATE 4"0 DRYER VENT MIN.3'AWAY FROM NATURAL OPENING ® 2d TO FC-3 I Q 10x0 _ _ TO THE BUILDING,10'AWAY FROM MECHANICAL AIR INTAKE.10'AWAY �'T 7-R - 1Y W j-200CFM 1-200 CFM FROM PROPERTY UNE AND IO'ABOVE GRADE.TERMINATE IN THE e I I 0 ( ,p \ _ Q I O �j {I ROOF SOFFIT. I I f 2I CF;Crti a 3,EDROO(vI I .' 00 WI �; +200 CFM +200 CFM A 0 ROUTE ERV EXHAUST&FRESH AIR INTAKE DUCTWORK TO EITHER �I� -J -- ROOF&TERMINATE W/GOOSENECK OR THROUGH SIDE WALL,EITHER I I 220 ___4 -.--+ WAY MUST BE 10'-0"FROM ANY MECHANICAL FRESH AIR INTAKES,3'-0"' - .- - / FROM ANY NATURAL AIR INTAKES,10'-0"FROM PROPERTY LINES OR 0 '.QIcimI FROMgi- THE ERVOVE F LINE.CONNECT TOTHE EXISTINGD DUPLY&RETURN CTWORK FOR FAN COILS BRK } 5,8x100 400 C r O© . v _ — ERV-2 DIAGRAMI I - - PROVIDE BALANCING DAMPERS.NEW EQUIPMENT PLAN LOCATION IS 100.50 ,l, 100-50 ,� 740. A _ SCHEMATIC TO SHOW INTENT,VERIFY AND LOCATE ACCORDINGLY 8x4 Bz4 A ` WITH GIVEN CEILING H€JGLITS INFIELD. f 0 ri�-f 7'0 8x0 '— �j il E -,•' -.-•." • AEC PROJECT#: 12017 25 To Existing ELI Circuit,ELI-I 11)575 ;� 688 �.®„ 1I I DA9-1 R C 60SI► L_x_J I 12-19-12 RFC#0676x12yp M 10x6 01-02-13 REVISION#11 A CFM CUSTOM RETURN ACCESS PANEL /� 02102.0-R6 I PLENUM DN 02-06-13 ASI#015 A zoaR 03-07-13 ASI#016 /© - 0 12`6-Q- --- 03-25-13 ASI#016 REVISION 3EDROOM 1 //� BEDRO•M 20o5 •-VD VD 2005 09 02-15 MECHANICAL REV. /0 242 0 7zx4 lu ul tzx4 0 239 Drawn CmckmeY -,70' / I� II ; MZ TOC El 2ND LEVEL ® -_ `- ,:.. /. - - -- - HVAC Mr.% ELECTRIC DUCT HEATER SCHEDULE OR EQUIVALENT I NORTH — V ,3 — PLAN O ELECTRICAL°ATA 2nd FLOOR HVAC PLAN ® m36x36 , _. 36x38 9 UNIT MANUFACTURER 8, CAPACITY #OF DIMENSIONS EAT LAT 3950-O A. 39500A1 SERVICE LOCATION REMARKS TAG MODEL NO. (KW) STAGES MN/ 1'F) ("FI KW ALPS V/PH/Hz WIRE BACK TO HOUSE PANELSENSOR ••��i/T .PROVIDE NR PROONNG SWITCH,DISCHARGE AR SCALE:1/4`=1'0' 76504JL/r- SCALE I�4�=I-O�� .H., WARREN ERV-1 DUCT MOUNTED 1 I 8'tli& 42 70 10 80 115/1/80 TECHNOLOGIES 72s38 WARREN ERV-2 DUCT MOUNTED 2 1 10'tlia 44 70 200 170 115/1/80 WIRE BACK TO HOUSE PANEL.PROVIDE AIR PROOVING SWITCH,DISCHARGE NR M2. 1 EDH-2 TECHNOLOGIES SENSOR 6 of 8 =001xG1 IM IIlM6x111L WOW 401#4011111102_.