Loading...
HomeMy WebLinkAboutA17-0064_Cutsheet Polarity reversal module_1506966540.pdfAgency Listings RRS-MOD Reversing Relay/ Synchronization Module The RRS-MOD reversing relay/synchronization module enhances the operation of 2- and 4-wire i3™ Series detectors equipped with a sounder. Features Is compatible with 2- and 4-wire i3 detectors equipped with a • sounder Activates all i3 sounders on a loop when one alarms• Synchronizes all i3 sounders on the loop for a clear alarm signal• Is usable with bell/alarm, alarm relay, or NAC outputs• Has a field-selectable switch to accommodate both coded and • continuous alarm signals Allows i3 detector silencing from the panel or keypad• Operates on 12 and 24 volt systems• Simplifies connections with quick-connect harness and color-coded • wires Installation ease. The RRS-MOD reversing relay/synchronization module includes a Velcro® attachment for easy installation into the fire alarm control panel cabinet. A quick-connect harness and color- coded wires simplify connections. Intelligence. The RRS-MOD module’s design is flexible to accommodate virtually any application. It is compatible with both 2- and 4-wire i3 Series detectors operating over 12 V and 24 V systems. The module can be used with either bell/alarm, alarm relay, or NAC outputs, and its field selectable switch accommodates both coded and continuous alarm signals. Instant inspection. To meet fire alarm requirements, the RRS-MOD reversing relay/synchronization module activates all i3 sounders on a loop when an individual sounder alarms. Additionally, it synchronizes the output of the i3 sounders, regardless of whether the panel’s alarm signal is continuous or coded, to ensure a clear alarm signal. S3705 3018895 7300-1653:165 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2007 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.A05-0350-001 • 8/07 • #1676 Wiring Diagrams NOTE: These diagrams represent two common wiring methods. Refer to the RRS-MOD installation manual for additional wiring configurations. Ordering Information Part No.Description RRS-MOD Reversing relay/synchronization module for i3 Series smoke detectors RRS-MOD Specifications Architectural/Engineering Specifications Reversing relay/synchronization module shall be a System Sensor i3™ Series model number RRS-MOD, listed to Underwriters Laboratories as a smoke detector accessory. The module shall allow all 2-wire and 4-wire i3 Series detectors equipped with a sounder on a loop to sound when one alarms. The module shall provide a switch to toggle between coded mode and continuous mode. When in coded mode, the module shall synchronize the i3 sounders on the loop to mirror the input signal. When in continuous mode, the module shall synchronize the i3 sounders on the loop to the ANSI S3.41 temporal coded pattern. In either coded or continuous modes, the RRS-MOD module shall permit sounders to be silenced at the panel. The RRS-MOD module shall operate between 8.5 and 35 VDC, and shall provide 18 AWG stranded, tinned conductors connected to a quick-connect harness. Physical Specifications Dimensions 2.5 in H × 2.5 in W × 1 in D (63 mm × 63 mm × 25 mm) Operating Temperature Range 32°F to 131°F (0°C to 55°C) Wire Connections 18 AWG stranded, tinned, 16 in length Operating Humidity Range 5% to 85% non-condensing Electrical Specifications Operating Voltage Nominal: 12/24 V Min: 8.5 V Max: 35 V Average Operating Current:25 mA Relay Contact Rating 2 A @ 35 VDC EOL OPTIONALREMOTEANNUNCIATOR(RA400Z) OPTIONALREMOTEANNUNCIATOR(RA400Z) + – UL LISTEDALARMCONTROLPANEL 2–WIREINITIATINGDEVICECIRCUIT PURPLET+ + – + – AUX POWER YELLOWIN+ ORANGE IN– REDPWR+ BLACKPWR– BROWNOUT+ WHITEOUT– 1 + IN 2 + OUT 3 - IN/OUT 4 RA+ 5 RA- 1 + IN 2 + OUT 3 - IN/OUT 4 RA+ 5 RA- + – BELL/ALARMCIRCUIT(positive signalin alarm state) ALARMRELAY(NO Contact) UL LISTEDALARMCONTROLPANEL 2–WIREINITIATINGDEVICECIRCUIT PURPLET+ + – + – AUX POWER YELLOWIN+ ORANGEIN– REDPWR+ BLACKPWR– BROWNOUT+ WHITE OUT– EOL OPTIONALREMOTEANNUNCIATOR(RA400Z) OPTIONALREMOTEANNUNCIATOR(RA400Z) + – 1 + IN 2 + OUT 3 - IN/OUT 4 RA+ 5 RA- 1 + IN 2 + OUT 3 - IN/OUT 4 RA+ 5 RA- + – S0101-00 2-Wire System Triggered from Alarm/Bell Circuit S0103-00 2-Wire System Triggered from Alarm Relay Contact