Loading...
HomeMy WebLinkAboutB17-0284_A-400_1507158056.pdfINTERIOR COMPACTED OR INDISTURBED EARTH F1A CONCRETE SLAB T O C REF TO PLANS GRAVEL BASE; RE: SOILS REPORT CONTINUOUS REINFORCED VAPOR RETARDER REINFORCED CONCRETE SLAB; RE STRUCTURAL DWGS F1B CONCRETE SLAB w/ RADIANT HEAT COMPACTED OR INDISTURBED EARTH FLOOR FINISH; RE: INTERIOR DWGS MIN. 1 1/2" T O C REF TO PLANS REINFORCED CONCRETE SLAB-ON-GRADE RE: STRUCTURAL DWGS; SLOPE AS REQUIRED RADIANT TUBING WHERE INDICATED 2" FOIL-FACED RIGID INSULATION (3" WITHIN 4'-0" OF EXT. WALLS) CONTINUOUS REINFORCED VAPOR RETARDER GRAVEL BASE; RE: SOILS REPORT INTERIOR GRAVEL BASE; RE: SOILS REPORT COMPACTED OR INDISTURBED EARTH REINFORCED CONCRETE SLAB-ON-GRADE RE: STRUCTURAL DWGS; SLOPE AS REQUIRED F1C.1 CONCRETE - STONE - RADIANT HEATING STONE OR PAVERS SLOPE AS REQUIRED RADIANT TUBING WHERE INDICATED MORTAR SETTING BED 1 1/2" 2" FOIL-FACED RIGID INSULATION, HIGH COMPRESSIVE STRENGTH WHERE REQUIRED T O C REF TO PLANS EXTERIOR CONTINUOUS REINFORCED VAPOR RETARDER F2A WOOD JOIST FLOOR - OVER UNCONDITIONED SPACE INTERIOR UNCONDITIONED SPACE BLOW-IN BLANKET INSULATION; R 3.7 PER INCH PLYWOOD SHEATHING RE: STRUCT DWGS FLOOR FINISH; RE: INTERIOR DWGS WOOD FLOOR JOIST; RE: STRUCT DWGS T O P REF TO PLANS CONTINUOUS REINFORCED VAPOR RETARDER R-VALUE INSULATION R3.7 x 11" =R40.7 INTERIOR 3" POLYURETHANE FOAM SPRAY; R 6.5 PER INCH PLYWOOD SHEATHING RE: STRUCT DWGS FLOOR FINISH; RE: INTERIOR DWGS WOOD FLOOR JOIST; RE: STRUCT DWGS EXTERIOR F2A.1 WOOD JOIST FLOOR - OVER EXTERIOR SPACE T O P REF TO PLANS CLG. HEIGHT REF TO INTERIOR DOCS CRINKLE BUILDING WRAP T&G SOFFIT CONTINUOUS REINFORCED VAPOR RETARDER 1/2" PLYWOOD BLOW-IN BLANKET INSULATION; R 3.7 PER INCH 8" 3" R-VALUE INSULATION R6.5 x 3" =R19.5 R3.7 x 8" =R29.6 =R49.1 GRAVEL BASE; RE: SOILS REPORT COMPACTED OR INDISTURBED EARTH F6C.1 STONE OR PAVERS SAND SET w/ RADIANT HEAT STONE OR PAVERS SLOPE AS REQUIRED SAND SETTING BED 2" FOIL-FACED RIGID INSULATION, HIGH COMPRESSIVE STRENGTH WHERE REQUIRED RADIANT TUBING WHERE INDICATED EXTERIOR EXTERIOR RADIANT TUBING WHERE INDICATED T O P REF TO PLANS CLG. HEIGHT REF TO INTERIOR DOCS WOOD FLOOR JOIST; RE: STRUCT DWGS PLYWOOD SHEATHING RE: STRUCT DWGS INTERIOR FINISH CEILING RE: INTERIOR DWGS STONE OR PAVERS SLOPE AS REQUIRED MORTAR SETTING BED 3" POLYURETHANE FOAM SPRAY; R 6.5 PER INCH F2C.3 THICK SET STONE FLOORING w/ SLOPED SLEEPERS OVER HABITABLE SPACE DRAINAGE MAT/ PROTECTION BOARD WATERPROOFING MEMBRANE TAPERED 2X SLEEPERS SLOPED AS REQUIRED W/ PLYWD DECK CONTINUOUS REINFORCED VAPOR RETARDER 5/8" TYPE "X" GYPSUM WALLBOARD BLOW-IN BLANKET INSULATION; R 3.7 PER INCH 8" 3" R-VALUE INSULATION R6.5 x 3" =R19.5 R3.7 x 8" =R29.6 =R49.1 EXTERIOR INTERIOR POLYURETHANE FOAM SPRAY INSULATION; R 6.5 PER INCH R1A -1HR ROOF ROOF FRAMING,RE: STRUCT DWGS SELF-ADHERING SHEET MEMBRANE WATERPROOFING (2) LAYERS GRACE ULTRA PLYWOOD SHEATHING, RE: STRUCT DWGS 2" SLOPED NAILABLE RIGID INSULATION 5/8" TYPE "X" GYPSUM WALLBOARD 12 VARIES RE: ROOF PLAN VARIES ROOFING SYSTEM, RE: ROOF PLAN FINISH CEILING RE: INTERIOR DWGS R-VALUE INSULATION R6.5 x 6" =R39 R6 x 2" =R12 =R51 6" 2" PLYWOOD SHEATHING, RE: STRUCT DWGS 5/8" TYPE "X" GYPSUM WALLBOARD STANDING SEAM ALUMINUM - ANODIZED DARK BRONZE 12" WIDTHS MANUFACTURUER TBD, COMPLIES WITH UL-790 CLASS A FIRE RATING. CONTINUOUS REINFORCED VAPOR RETARDER R1D-IHR EXTERIOR TO ACCOMPANY R1A-1HR ON TIMBER RAFTERS EXTERIOR SELF-ADHERING SHEET MEMBRANE WATERPROOFING (2) LAYERS GRACE ULTRA PLYWOOD SHEATHING, RE: STRUCT DWGS 2" SLOPED NAILABLE RIGID INSULATION PLYWOOD SHEATHING, RE: STRUCT DWGS 12 VARIES RE: ROOF PLAN ROOFING SYSTEM, RE: ROOF PLAN EXPOSED RAFTER ROOF STRUCTURE; RE: STRUCT DWGS 2X6 T&G WOOD SOFFIT BOARDS EXTERIOR 5/8" TYPE "X" GYPSUM WALLBOARD STANDING SEAM ALUMINUM - ANODIZED DARK BRONZE 12" WIDTHS MANUFACTURUER TBD, COMPLIES WITH UL-790 CLASS A FIRE RATING. R1C-IHR EPDM OR TPO ROOF INTERIOR EXTERIOR ROOF STRUCTURE RE: STRUCT DWGS PLYWOOD SHEATHING, RE: STRUCT DWGS 2" FOIL-FACED, RIGID INSULATION WHERE REQ'D DRAINAGE MAT/ PROTECTION BOARD RE: INTERIOR DWGS FOR FINISH POLYURETHANE FOAM SPRAY INSULATION; R 6.5 PER INCH ADHESIVE THERMOPLASTIC-POLYOLEFIN ROOFING 5/8" TYPE "X" GYPSUM WALLBOARD CONTINUOUS REINFORCED VAPOR RETARDER 5/8" TYPE "X" GYPSUM WALLBOARD T O P REF TO PLANS CLG. HEIGHT REF TO INTERIOR DOCS 2 1/8" 6" R-VALUE INSULATION R6.5 x 6" =R39 R6 x 2" =R12 =R51 SLOPE & ROOF DRAINS NOT SHOWN ON DETAIL; REFER TO ROOF PLAN A-102 & DETAILS A-404 CONNECTION TO STANDING SEAM METAL ROOFING AS SPECIFIED BY MANUFACTURE: REFER ROOF PLAN FOR SNOW FANCE LOCATIONS EXTERIOR EXTERIOR T O P REF TO PLANS TIMBER DECK JOISTS RE: STRUCT DWGS WATERPROOFING MEMBRANE PLYWOOD SHEATHING RE: STRUCT DWGS T&G DECKING RE: TO STRUCT DWGS DRAINAGE MAT/ PROTECTION BOARD RADIANT TUBING WHERE INDICATED MORTAR SETTING BED STONE OR PAVERS SLOPE AS REQUIRED F4C-1HR THICK SET STONE FLOORING ON TAPERED 2X SLEEPER w/ INSULATION ON TIMBER STRUCTURE TAPERED 2X SLEEPERS SLOPED AS REQUIRED W/ PLYWD DECK 5/8" TYPE "X" GYPSUM WALLBOARD NOTE: EXPOSED TIMBERS AND DECKING MEETS EAGLE COUNTY WILDFIRE HAZARD REQUIREMENTS. EXTERIOR EXTERIOR RADIANT TUBING WHERE REQUIRED T O P REF TO PLANS WOOD FLOOR JOIST; RE: STRUCT DWGS PLYWOOD SHEATHING RE: STRUCT DWGS 3" POLYURETHANE FOAM SPRAY; R 6.5 PER INCH 2X6 T&G WOOD SOFFIT BOARDS WATERPROOFING MEMBRANE DRAINAGE MAT/ PROTECTION BOARD STONE OR PAVERS SLOPE AS REQUIRED MORTAR SETTING BED F2C.4 1HR THICK SET STONE FLOORING ON TAPERED 2X SLEEPERS INSULATION ON WOOD JOISTS w/ SOFFIT OVER EXTERIOR SPACE TAPERED 2X SLEEPERS SLOPED AS REQUIRED W/ PLYWD DECK CRINKLE BUILDING WRAP 5/8" TYPE X, MOLD AND MOISTURE RESISTANT, FIRE-RESISTANT CORE 5/8" TYPE X, MOLD AND MOISTURE RESISTANT, FIRE-RESISTANT CORE LEVEL 02 8167' - 5" LEVEL 03 8177' - 10" LEVEL 04 8188' - 5" LEVEL 05 8199' - 10" W2C SIM F2A FF4 BLOW-IN BLANKET INSULATION; R 3.7 PER INCH W2E 1HR W2C SIM F2A W2E 1HR FF6 FF4 F2A W2E 1HR W2E 1HR R1A-1HR R1A-1HR 7 1/4" MASTER BEDROOM FAMILY / DINING BEDROOM #3 REC / BUNK ROOM STANDING SEAM METAL ROOF 2X6 T&G WOOD SOFFIT BOARDS 7 1/4" POLYURETHANE FOAM SPRAY; R 6.5 PER INCH BLOW-IN BLANKET INSULATION; R 3.7 PER INCH POLYURETHANE FOAM SPRAY INSULATION; R 6.5 PER INCH BLOW-IN BLANKET INSULATION; R 3.7 PER INCH BLOW-IN BLANKET INSULATION; R 3.7 PER INCH POLYURETHANE FOAM SPRAY INSULATION; R 6.5 PER INCH BLOW-IN BLANKET INSULATION; R 3.7 PER INCH BLOW-IN BLANKET INSULATION; R 3.7 PER INCH BLOW-IN BLANKET INSULATION; R 3.7 PER INCH BLOW-IN BLANKET INSULATION; R 3.7 PER INCH BLOW-IN BLANKET INSULATION; R 3.7 PER INCH TWO POLE SNOW GUARD 2" FOIL-FACED, RIGID INSULATION WHERE REQ'D CONCRETE FOOTING, RE: STRUCTURAL DWGS CONCRETE FOOTING, RE: STRUCTURAL DWGS CONTINUOUS REINFORCED VAPOR RETARDER W1B SIM HOT FLUID-APPLIED RUBBERIZED ASPHALT WATERPROOFING TO 18" A.F. GRADE 2" FOIL-FACED, RIGID INSULATION WHERE REQ'D UNIT 8/10 ROOF AND WALL CONDITION TO BE COORDINATED STANDING SEAM ALUMINUM - ANODIZED DARK BRONZE 12" WIDTHS MANUFACTURUER TBD, COMPLIES WITH UL-790 CLASS A FIRE RATING. METAL SIDING 1" CONTINUOUS RIGID INSULATION (R-5 PER INCH) 5/8" TYPE X, MOLD AND MOISTURE RESISTANT, FIRE-RESISTANT CORE 5/8" TYPE X, MOLD AND MOISTURE RESISTANT, FIRE-RESISTANT CORE 5/8" TYPE X, MOLD AND MOISTURE RESISTANT, FIRE-RESISTANT CORE 5/8" TYPE "X" GYPSUM WALLBOARD R1A-1HR W1B-2HR PROJECT: SHEPHERD RESOURCES INC/AIA 970 949 3302 M O C . T C E T I H R A I R P B OX 8 40 105 EDWAR DS BLVD O ST FFI C E O S U I T E C103 E D W A R DS C O 81 6 3 2 V I LLAGE A-400 1408.04 August 31, 2017 LOT 9 303 GORE CREEK DRIVE GALVIN RESIDENCE PERMIT REVISION TYPICAL WALL SECTION, ROOF & FLOOR TYPES SCALE: 1 1/2" = 1'-0" FLOOR TYPES SCALE: 1 1/2" = 1'-0" ROOF TYPES NO SCALE STANDING SEAM SNOW FENCE DATE ISSUE 08/31/2017 Permit Review Comments SCALE: 3/4" = 1'-0" 1 WALL SECTION SCALE: 1 1/2" = 1'-0" 13 SECTION VIEW SOUTH ROOF AT PARTYWALL 10/04/17