HomeMy WebLinkAboutB17-0284_A-401_1507158057.pdfEXTERIOR INTERIOR
NOTE:
WATERPROOFING
MEMBRANE AT ALL
WALLS BELOW
FINISHED GRADE
REINFORCED CONCRETE
WALL, RE: STRUCTURAL
DWGS
HOT FLUID-APPLIED
RUBBERIZED ASPHALT
WATERPROOFING TO 18"
A.F. GRADE
2" INSULATED DRAINAGE
BOARD (R-10)
W1A
CONCRETE WALL
RE: STRUCT DWGS
EXTERIOR
REINFORCED CONCRETE
WALL, RE: STRUCTURAL
DWGS
2" INSULATED DRAINAGE
BOARD (R-10)
W1B
CONCRETE WALL W/ FURRING
WATERPROOFING
MEMBRANE TO 18" MIN.
ABOVE FINISH GRADE
(2) LAYERS AIR
INFILTRAION BARRIER
ABOVE
CONTINUOUS
REINFORCED VAPOR
RETARDER
RE: PLANS RE: STRUCT DWGS
RE: INTERIOR DWGS
FOR FINISH
BLANKET (BATT)
INSULATION
2X FURRING
RE:PLANS FOR DEPTH
INTERIOR
NOTE:
WATERPROOFING
MEMBRANE AT ALL
WALLS BELOW
FINISHED GRADE
EXTERIOR EXTERIOR
W1C
CONCRETE WALL W/ STONE VENEER
REINFORCED CONCRETE
WALL, RE: STRUCTURAL
DWGS
1/2" INSULATED
DRAINAGE BOARD
MORTAR SETTING BED
STONE VENEER;
ANCHORED TO
STRUCTURE AS REQD
WATERPROOFING
MEMBRANE TO 18" MIN.
ABOVE FINISH GRADE
(2) LAYERS AIR
INFILTRAION BARRIER
ABOVE
RE: STRUCT DWGS
MASONRY TIES AS REQ'D
WEEP HOLES AS REQ'D
HOT FLUID-APPLIED
RUBBERIZED ASPHALT
WATERPROOFING TO 18"
A.F. GRADE
2" INSULATED DRAINAGE
BOARD (R-10)
EXTERIOR EXTERIOR
W1C.1
CONCRETE WALL W/ STONE VENEER BOTH SIDES
REINFORCED CONCRETE
WALL, RE: STRUCTURAL
DWGS
1/2" INSULATED
DRAINAGE BOARD
WATERPROOFING
MEMBRANE TO 18" MIN.
ABOVE FINISH GRADE
(2) LAYERS AIR
INFILTRAION BARRIER
ABOVE
RE: STRUCT DWGS
NOTE:
MATERIALS ARE
SAME BOTH SIDES
MASONRY TIES AS REQ'D
WEEP HOLES AS REQ'D
STONE VENEER;
ANCHORED TO
STRUCTURE AS REQD
EXTERIOR
INTERIOR
REINFORCED CONCRETE
WALL, RE: STRUCTURAL
DWGS
MORTAR SETTING BED
DRAINAGE MAT/
PROTECTION BOARD
RE: STRUCT DWGS
FURRING 24" O.C.
RE: INTERIOR DWGS
FOR FINISH
W1C.2
CONCRETE WALL W/ STONE VENEER - 2x FURRING
STONE VENEER;
ANCHORED TO
STRUCTURE AS REQD
WATERPROOFING
MEMBRANE TO 18" MIN.
ABOVE FINISH GRADE
(2) LAYERS AIR
INFILTRAION BARRIER
ABOVE
BLANKET (BATT)
INSULATION
INTERIOR EXTERIOR
REINFORCED CONCRETE
WALL, RE: STRUCTURAL
DWGS
1/2" INSULATED
DRAINAGE BOARD
MORTAR SETTING BED
RE: STRUCT DWGS
FURRING 24" O.C.
RE: INTERIOR DWGS
FOR FINISH
1/2" RESILIENT
CHANNEL; CLARK
DIETRICH OR
APPROVED EQUAL
W1C.3
CONCRETE WALL - STONE VENEER - RESILIENT CHANNEL
STONE VENEER;
ANCHORED TO
STRUCTURE AS REQD
BLANKET (BATT)
INSULATION
EXTERIOR
INTERIOR
REINFORCED CONCRETE
WALL, RE: STRUCTURAL
DWGS
1 1/2" RIGID
INSULATION
2X FURRING
RE:PLANS FOR DEPTH
W1F
CONCRETE - WOOD SIDING
RE: STRUCT DWGS
WOOD SIDING
EXTERIOR INTERIOR
W2A
WOOD FRAMING w/ WOOD SIDING
RE: INTERIOR DWGS
FOR FINISH
BLOW-IN BLANKET
INSULATION; R 3.7 PER
INCH
2X6 WOOD FRAMING RE:
STRUCT DWGS
PLYWOOD SHEATHING
RE: STRUCT DWGS
1.25" RIGID MINERAL
WOOL INSULATION
SHEATHING BOARD; R-5
PER INCH
CRINKLE BUILDING
WRAP
WOOD SIDING
RE: STRUCT DWGS
EXTERIOR INTERIOR
W2B
WOOD FRAMING w/ METAL SIDING
BLOW-IN BLANKET
INSULATION; R 3.7 PER
INCH
2X6 WOOD FRAMING RE:
STRUCT DWGS
PLYWOOD SHEATHING
RE: STRUCT DWGS
1.25" RIGID MINERAL
WOOL INSULATION
SHEATHING BOARD; R-5
PER INCH
CRINKLE BUILDING
WRAP
5 1/2"
RE: STRUCT DWGS
METAL SIDING
RE: INTERIOR DWGS
FOR FINISH
EXTERIOR
INTERIOR
W2C
WOOD FRAMING w/ STONE VENEER
BLOW-IN BLANKET
INSULATION; R 3.7 PER
INCH
2X6 WOOD FRAMING RE:
STRUCT DWGS
PLYWOOD SHEATHING
RE: STRUCT DWGS
1.25" RIGID MINERAL
WOOL INSULATION
SHEATHING BOARD; R-5
PER INCH
CRINKLE BUILDING
WRAP
5 1/2"
RE: STRUCT DWGS
RE: INTERIOR DWGS
FOR FINISH
STONE VENEER;
ANCHORED TO
STRUCTURE AS REQD
MORTAR SETTING BED
WEEP HOLES AS REQ'D
MASONRY TIES AS REQ'D
EXTERIOR
EXTERIOR
W2C.1
WOOD FRAMING w/ STONE VENEER - BOTH SIDES
BLOW-IN BLANKET
INSULATION; R 3.7 PER
INCH
2X6 WOOD FRAMING RE:
STRUCT DWGS
PLYWOOD SHEATHING
RE: STRUCT DWGS
1.25" RIGID MINERAL
WOOL INSULATION
SHEATHING BOARD; R-5
PER INCH
CRINKLE BUILDING
WRAP
RE: STRUCT DWGS
STONE VENEER;
ANCHORED TO
STRUCTURE AS REQD
MORTAR SETTING BED
WEEP HOLES AS REQ'D
VAPOR BARRIER
W2I
2x4 WOOD FRAMING w/ GWB BOTH SIDES
INTERIOR INTERIOR
FULL DEPTH NATURAL
FIBER SOUND BATT
INSULATION
5/8" TYPE "X" GYPSUM
WALLBOARD
FURRING 24" O.C.
W2I.1
2x2 WOOD FRAMING w/ GWB BOTH SIDES
INTERIOR INTERIOR
5/8" TYPE "X" GYPSUM
WALLBOARD
2X4 LAID FLAT
W2I.2
2x6 WOOD FRAMING w/ GWB BOTH SIDES
INTERIOR INTERIOR
5/8" TYPE "X" GYPSUM
WALLBOARD
2X6 WOOD FRAMING RE:
STRUCT DWGS
5/8" TYPE "X" GYPSUM
WALLBOARD
FULL DEPTH NATURAL
FIBER SOUND BATT
INSULATION
W2K
2x4 WOOD FRAMING - GWB
INTERIOR INTERIOR
FULL DEPTH NATURAL
FIBER SOUND BATT
INSULATION
FURRING 24" O.C.
5/8" TYPE "X" GYPSUM
WALLBOARD
W2L
2x4 WOOD FRAMING 2-LAYERS GWB
INTERIOR INTERIOR
FULL DEPTH NATURAL
FIBER SOUND BATT
INSULATION
FURRING 24" O.C.
5/8" TYPE "X" GYPSUM
WALLBOARD (2) LAYERS
2X6 WOOD FRAMING RE:
STRUCT DWGS
5/8" TYPE "X" GYPSUM
WALLBOARD
MORTAR-BED TILING
CERAMIC TILE
W2O
WOOD FRAMING w/ 1/4" TILE
RE: INTERIOR DWGS
FOR FINISH
WALL NOTES:
WHEN GWB IS INDICATED ON INTERIORS
DRAWINGS, STANDARD WALLS SHALL BE TYPE X".
DAMP LOCATIONS REQUIRE GREENBOARD.
WET LOCATIONS REQUIRE GREENBOARD.
WET LOCATIONS REQUIRE CEMENT BOARD.
SILL GASKET TYPICAL AT BASE OF WALL
INTERIOR INTERIOR
FULL DEPTH NATURAL
FIBER SOUND BATT
INSULATION
PROJECT:
SHEPHERD RESOURCES INC/AIA
970 949 3302
M
O C . T C E T I H R A I R
P B OX 8 40
105 EDWAR DS BLVD
O ST FFI C E O
S U I T E C103
E D W A R DS C O 81 6 3 2
V I LLAGE
A-401
1408.04
August 31, 2017
LOT 9
303 GORE CREEK
DRIVE
GALVIN
RESIDENCE
PERMIT REVISION
WALL TYPES
SCALE: 1 1/2" = 1'-0"
TYPICAL EXTERIOR & INTERIOR WALL
TYPES
DATE ISSUE
08/31/2017 Permit Review Comments
10/04/17