B17-0284_A-800_1507158050.pdf
WINDOW NOTES #1 - PROVIDE WINDOW OPERATION CONTROL DEVICES WITH FALL PROJECTION R312.2 TO MEET CODE COMPLIANCE. #2 - ALL BROMBAL WINDOWS AND DOORS ARE DESIGNED WITH TEMPERED GLAZING. #3 - EGRESS WINDOW WILL MEET 5.7 SQ FT, HARDWARE WILL ALLOW WINDOW OPENING AND OPERATION TO MEET CODE COMPLIANCE. PROJECT: SHEPHERD RESOURCES INC/AIA 970 949 3302 M O C . T C E T I H R A I R P B OX 8 40 105 EDWAR DS B LVD OST FF I C E O S U I T E C103 E D W A R DS CO 81 6 3 2 V I LLAGE A-800 1408.04 August 31, 2017 LOT 9 303 GORE CREEK DRIVE GALVIN RESIDENCE PERMIT REVISION SCHEDULES EXTERIOR DOOR SCHEDULE MARK ROOM OPERATION MANUFACTURER WIDTH HEIGHT THICKNESS SAFTEY GLAZING U-VALUE SOLAR HEAT GAIN COEFFCIENT FIRE RATING COMMENTS LEVEL 02 D01 REC / BUNK ROOM HINGED TBD 3' - 0" 6' - 8" 1 3/4" Yes .21 0.3400 BTU/(h·ft ·°F) 1 HR GLAZING TO BE FIRELITE LEVEL 03 D02 ELEC CLOSET HINGED PAIR CUSTOM 4' - 8" 7' - 0" 1 3/4" Yes D03 TRASH CLOSET HINGED CUSTOM 3' - 0" 7' - 6" 1 3/4" D04 HINGED CUSTOM 2' - 0" 7' - 0" 1 3/4" D05 SKI ROOM HINGED BROMBAL 3' - 0" 7' - 6" 1 3/4" .21 0.3400 BTU/(h·ft ·°F) D06 ENTRY HINGED BROMBAL 3' - 0" 7' - 6" 1 3/4" LEVEL 04 D07 LIVING LIFT & SLIDE BROMBAL 7' - 6" 9' - 0" 2" Yes .26 0.3900 BTU/(h·ft ·°F) D08 LIVING LIFT & SLIDE BROMBAL 7' - 6" 9' - 0" 2" Yes .26 0.3900 BTU/(h·ft ·°F) D09 FAMILY / DINING LIFT & SLIDE BROMBAL 13' - 0" 9' - 0" 2" Yes .26 0.3900 BTU/(h·ft ·°F) LEVEL 05 D10 FAMILY / OFFICE SLIDING BROMBAL 12' - 0" 9' - 0" 2" Yes .26 0.3900 BTU/(h·ft ·°F) INTERIOR DOOR SCHEDULE MARK ROOM OPERATION WIDTH HEIGHT THICKNESS FIRE RATING COMMENTS LEVEL 01 101 MECHANICAL / STORAGE HINGED 3' - 0" 5' - 0" 1 3/4" 3/4 HR 102 HINGED 3' - 0" 5' - 6" 1 3/4" SELF CLOSING HINGES 103 HINGED 3' - 0" 5' - 6" 1 3/4" SELF CLOSING HINGES LEVEL 02 201 CLOSET SLIDING 2' - 8" 7' - 6" 1 3/4" 202 BATH #2 HINGED 2' - 4" 7' - 6" 1 3/4" 203 BEDROOM #2 HINGED 2' - 8" 7' - 6" 1 3/4" 204 TLT #2 HINGED 2' - 4" 7' - 6" 1 3/4" 205 HALL HINGED 2' - 10" 7' - 6" 1 3/4" 206 LAUNDRY #1 HINGED 2' - 8" 7' - 6" 1 3/4" 207 HALL HINGED 3' - 0" 7' - 6" 1 3/4" 208 REC / BUNK ROOM HINGED 2' - 8" 7' - 6" 1 3/4" 209 REC / BUNK ROOM SLIDING 2' - 4" 7' - 6" 1 3/4" 210 BATH #1 POCKET 2' - 4" 7' - 6" 1 3/4" 211 BATH #1 HINGED 2' - 0" 7' - 6" 1 3/4" LEVEL 03 301 SKI ROOM HINGED 2' - 8" 7' - 6" 1 3/4" 302 POWDER #1 HINGED 2' - 4" 7' - 6" 1 3/4" 303 LAUNDRY #2 HINGED 2' - 8" 7' - 6" 1 3/4" 304 HALL HINGED 4' - 0" 7' - 0" 1 3/4" 305 HALL HINGED 3' - 0" 7' - 6" 1 3/4" 306 BEDROOM #3 HINGED 2' - 8" 7' - 6" 1 3/4" 307 CLOSET #3 POCKET 2' - 4" 7' - 6" 1 3/4" 308 BATH #3 HINGED 2' - 4" 7' - 6" 1 3/4" 309 TLT #3 POCKET 2' - 4" 7' - 6" 1 3/4" LEVEL 04 401 KITCHEN STORED BI-FOLD 3' - 8" 7' - 6" 1 3/4" 402 KITCHEN HINGED 3' - 0" 7' - 6" 1 3/4" LEVEL 05 501 HALL HINGED 2' - 8" 7' - 0" 1 3/4" 502 BATH #4 POCKET 2' - 4" 7' - 0" 1 3/4" 503 BATH #4 POCKET 2' - 4" 7' - 0" 1 3/4" 504 HALL HINGED 2' - 6" 7' - 0" 1 3/4" 505 HALL HINGED 3' - 0" 7' - 0" 1 3/4" 506 MASTER BEDROOM HINGED 2' - 8" 7' - 0" 1 3/4" 508 MASTER BATH HINGED 2' - 6" 7' - 0" 1 3/4" 509 MASTER BATH POCKET 2' - 4" 7' - 0" 1 3/4" D12 HINGED 2' - 4" 7' - 0" 1 3/4" D13 2' - 4" 6' - 8" 1 3/4" MILLWORK DOOR SCHEDULE MARK ROOM OPERATION WIDTH HEIGHT THICKNESS COMMENTS LEVEL 02 MWK6 HINGED 2' - 4" 7' - 6" 1" MWK8 2' - 0" 7' - 0" 1" MWK7 REC / BUNK ROOM HINGED 2' - 4" 7' - 6" 1" LEVEL 04 MWK2 KITCHEN HINGED 1' - 6" 7' - 6" 1" BUILT IN CUSTOM CABINETS MWK1 KITCHEN HINGED 1' - 6" 7' - 6" 1" BUILT IN CUSTOM CABINETS LEVEL 05 MWK3 MASTER BEDROOM HINGED PAIR 3' - 0" 7' - 0" 1" BUILT IN CUSTOM CABINETS WINDOW SCHEDULE MARK ROOM OPERATION / VENTALATION WIDTH HEIGHT EGRESS MANUFACTURER HEAD HEIGHT SILL HEIGHT SAFTEY GLAZING U-VALUE SOLAR HEAT GAIN COEFFCIENT COMMENTS LEVEL 02 201 BEDROOM #2 CASEMENT 3' - 8" 6' - 0" Yes Brombal 8' - 0" 2' - 0" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #2, #3 202 REC / BUNK ROOM CASEMENT 3' - 0" 5' - 2" Yes Brombal 8' - 8" 3' - 6" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #2, #3 203 REC / BUNK ROOM FIXED 4' - 8" 5' - 2" Brombal 8' - 8" 3' - 6" Yes .19 0.3200 BTU/(h·ft ·°F) NOTE #2 204 REC / BUNK ROOM CASEMENT 3' - 0" 5' - 2" Yes Brombal 8' - 8" 3' - 6" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #2, #3 LEVEL 03 301 SKI ROOM CASEMENT 2' - 0" 2' - 8" Brombal 7' - 2" 4' - 6" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #2 302 BEDROOM #3 CASEMENT 3' - 0" 6' - 10" Yes Brombal 8' - 2" 1' - 4" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #1, #2, #3 303 BEDROOM #3 FIXED 4' - 8" 6' - 10" Brombal 8' - 2" 1' - 4" Yes .19 0.3200 BTU/(h·ft ·°F) NOTE #2 304 BEDROOM #3 CASEMENT 3' - 0" 6' - 10" Yes Brombal 8' - 2" 1' - 4" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #1, #2, #3 305 CLOSET #3 ARCHED TOP CASEMENT 2' - 0" 3' - 0" Brombal 7' - 6" 4' - 6" .24 0.0000 BTU/(h·ft ·°F) NOTE #2 LEVEL 04 401 KITCHEN FIXED 7' - 8" 6' - 0" Custom 9' - 4" 3' - 4" Yes .19 0.3200 BTU/(h·ft ·°F) CUSTOM INTERIOR WINDOW LEVEL 05 501 MASTER BEDROOM CASEMENT 3' - 0" 5' - 10" Yes Brombal 6' - 10" 1' - 0" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #1, #2, #3 502 MASTER BEDROOM FIXED 7' - 0" 5' - 10" Brombal 6' - 10" 1' - 0" Yes .19 0.3200 BTU/(h·ft ·°F) NOTE #2 503 MASTER BEDROOM CASEMENT 3' - 0" 5' - 10" Yes Brombal 6' - 10" 1' - 0" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #1, #2, #3 504 HALL FIXED 3' - 0" 6' - 6" No Brombal 7' - 0" 6" Yes .19 0.3200 BTU/(h·ft ·°F) CUSTOM INTERIOR WINDOW 505 FAMILY / OFFICE ARCHED TOP 3' - 0 1/2" 1' - 1" No Brombal 10' - 1" 9' - 0" .19 0.3200 BTU/(h·ft ·°F) NOTE #2 506 FAMILY / OFFICE ARCHED TOP 3' - 0 1/2" 1' - 1" No Brombal 10' - 1" 9' - 0" .19 0.3200 BTU/(h·ft ·°F) NOTE #2 507 FAMILY / OFFICE ARCHED TOP 5' - 11" 2' - 0" No Brombal 10' - 11 1/2" 8' - 11 1/2" .19 0.3200 BTU/(h·ft ·°F) NOTE #2 NO SCALE LIGHT & VENTILATION CALCULATIONS 4 4 DATE ISSUE 2/20/2017 DRB Final Review 5/15/2017 DRB Final Review 07/21/2017 PERMIT 08/31/2017 Permit Review Comments 10/04/17