Loading...
HomeMy WebLinkAboutB17-0284_F-100_1507158060.pdf4 5 9 F-100 4 5 9 F-100 DOOR D01 1 HR RATING 1HR FIRE RATING 4 5 9 F-100 10 F-100 11 F-100 CANOPY 1 HR RATED 1HR FIRE RATING 4 5 9 F-100 1HR FIRE RATING DECK 1 HR RATED 4 5 9 F-100 1HR FIRE RATING 1 HR 2HR RATED WALLS NOTE: LEVEL 2 DOOR D01 & CANOPY PROJECTION SHALL HAVE A 1HR FIRE- RESISTANCE RATING. DOOR GLAZING TO BE FIRELITE AND 1 HR RATING 4 5 3" / 12" 3" / 12" 3" / 12" 3" / 12" DECK BELOW CURVED DORMER CURVED DORMER FLAT ROOF CHIMNEY CHIMNEY 9 F-100 2HR RATED PARTY WALL TO UNDERSIDE OF ROOF DECKING PER CODE STANDING SEAM ALUMINUM - ANODIZED DARK BRONZE 12" WIDTHS MANUFACTURUER TBD, COMPLIES WITH UL-790 CLASS A FIRE RATING. R1A-1HR R1A-1HR R1A-1HR R1A-1HR R1C-1HR LEVEL 02 8167' - 5" LEVEL 03 8177' - 10" LEVEL 04 8188' - 5" LEVEL 05 8199' - 10" LEVEL 01 8160' - 8" 4 5 2HR RATED PARTY WALL TO UNDERSIDE OF ROOF DECKING PER CODE STANDING SEAM ALUMINUM - ANODIZED DARK BRONZE 12" WIDTHS MANUFACTURUER TBD, COMPLIES WITH UL-790 CLASS A FIRE RATING. LEVEL 02 8167' - 5" LEVEL 03 8177' - 10" LEVEL 04 8188' - 5" LEVEL 05 8199' - 10" 4 5 DOOR D01 & PROJECTION CANOPY 1 HR RATED LEVEL 03 8177' - 10" LEVEL 04 8188' - 5" LEVEL 05 8199' - 10" 4 5 EXTERIOR INTERIOR 1HR RATED - SIM W2A, W2B W2C WOOD FRAMING WITH APPLIED SIDING RE: INTERIOR DWGS FOR FINISH BLOW-IN BLANKET INSULATION; R 3.7 PER INCH 2X6 WOOD FRAMING RE: STRUCT DWGS PLYWOOD SHEATHING RE: STRUCT DWGS 1.25" RIGID MINERAL WOOL INSULATION SHEATHING BOARD; R-5 PER INCH CRINKLE BUILDING WRAP 5/8" 5/8" 5/8" TYPE "X" GYPSUM WALLBOARD 5/8" TYPE "X" GYPSUM WALLBOARD RE: STRUCT DWGS FINISH SIDING MATERIAL; REFER TO WALL TYPES INTERIOR REINFORCED CONCRETE WALL, RE: STRUCTURAL DWGS 2HR CONCRETE PARTY WALL W/ UNIT STUD WALLS VAPOR BARRIER RE: PLANS RE: STRUCT DWGS AT PARTY WALL ADJOINING TOWNHOME 5/8" TYPE "X" GYPSUM WALLBOARD BLOW-IN BLANKET INSULATION; R 3.7 PER INCH INTERIOR 5/8" TYPE "X" GYPSUM WALLBOARD PROJECT: SHEPHERD RESOURCES INC/AIA 970 949 3302 M O C . T C E T I H R A I R P B OX 8 40 105 EDWAR DS BLVD O ST FFI C E O S U I T E C103 E D W A R DS C O 81 6 3 2 V I LLAGE F-100 1408.04 August 31, 2017 LOT 9 303 GORE CREEK DRIVE GALVIN RESIDENCE PERMIT REVISION RATED ASSEMBLIES SCALE: 1/8" = 1'-0" 1 LEVEL 1 PLAN - MECHANICAL LEVEL SCALE: 1/8" = 1'-0" 2 LEVEL 2 PLAN - LOWER LEVEL SCALE: 1/8" = 1'-0" 3 LEVEL 03 SCALE: 1/8" = 1'-0" 4 LEVEL 04 SCALE: 1/8" = 1'-0" 5 LEVEL 05 SCALE: 1/8" = 1'-0" 8 ROOF FIRE RATING SCALE: 1/8" = 1'-0" 9 RATED WALL SECTION SCALE: 1/8" = 1'-0" 10 NORTH ELEVATION - RATED WALLS SCALE: 1/8" = 1'-0" 11 SOUTH ELEVATION - RATED WALLS DATE ISSUE 2/20/2017 DRB Final Review 5/15/2017 DRB Final Review 07/21/2017 PERMIT 08/31/2017 Permit Review Comments SCALE: 1 1/2" = 1'-0" 1HR RATED EXTERIOR WALL TYPICAL SCALE: 1 1/2" = 1'-0" 2HR PARTY WALL TYPICAL 10/04/17