HomeMy WebLinkAboutB17-0285_A-400_1507158103.pdfINTERIOR
COMPACTED OR
INDISTURBED EARTH
F1A
CONCRETE SLAB
T O C
REF TO PLANS
GRAVEL BASE;
RE: SOILS REPORT
CONTINUOUS
REINFORCED VAPOR
RETARDER
REINFORCED CONCRETE
SLAB; RE STRUCTURAL
DWGS
F1B
CONCRETE SLAB w/ RADIANT HEAT
COMPACTED OR
INDISTURBED EARTH
FLOOR FINISH; RE:
INTERIOR DWGS
MIN.
1 1/2"
T O C
REF TO PLANS
REINFORCED CONCRETE
SLAB-ON-GRADE
RE: STRUCTURAL DWGS;
SLOPE AS REQUIRED
RADIANT TUBING
WHERE INDICATED
2" FOIL-FACED RIGID
INSULATION (3" WITHIN
4'-0" OF EXT. WALLS)
CONTINUOUS
REINFORCED VAPOR
RETARDER
GRAVEL BASE;
RE: SOILS REPORT
INTERIOR
GRAVEL BASE;
RE: SOILS REPORT
COMPACTED OR
INDISTURBED EARTH
REINFORCED CONCRETE
SLAB-ON-GRADE
RE: STRUCTURAL DWGS;
SLOPE AS REQUIRED
F1C.1
CONCRETE - STONE - RADIANT HEATING
STONE OR PAVERS
SLOPE AS REQUIRED
RADIANT TUBING
WHERE INDICATED
MORTAR SETTING BED
1 1/2"
2" FOIL-FACED RIGID
INSULATION, HIGH
COMPRESSIVE
STRENGTH WHERE
REQUIRED
T O C
REF TO PLANS
EXTERIOR
CONTINUOUS
REINFORCED VAPOR
RETARDER
F2A
WOOD JOIST FLOOR - OVER
UNCONDITIONED SPACE
INTERIOR
UNCONDITIONED
SPACE
BLOW-IN BLANKET
INSULATION; R 3.7 PER
INCH
PLYWOOD SHEATHING
RE: STRUCT DWGS
FLOOR FINISH; RE:
INTERIOR DWGS
WOOD FLOOR JOIST;
RE: STRUCT DWGS
T O P
REF TO PLANS
CONTINUOUS
REINFORCED VAPOR
RETARDER
R-VALUE INSULATION
R3.7 x 11" =R40.7
INTERIOR
3" POLYURETHANE FOAM
SPRAY; R 6.5 PER INCH
PLYWOOD SHEATHING
RE: STRUCT DWGS
FLOOR FINISH; RE:
INTERIOR DWGS
WOOD FLOOR JOIST;
RE: STRUCT DWGS
EXTERIOR
F2A.1
WOOD JOIST FLOOR - OVER EXTERIOR SPACE
T O P
REF TO PLANS
CLG. HEIGHT
REF TO
INTERIOR DOCS
CRINKLE BUILDING
WRAP
T&G SOFFIT
CONTINUOUS
REINFORCED VAPOR
RETARDER
1/2" PLYWOOD
BLOW-IN BLANKET
INSULATION; R 3.7 PER
INCH
8" 3"
R-VALUE INSULATION
R6.5 x 3" =R19.5
R3.7 x 8" =R29.6
=R49.1
GRAVEL BASE;
RE: SOILS REPORT
COMPACTED OR
INDISTURBED EARTH
F6C.1
STONE OR PAVERS SAND SET w/ RADIANT HEAT
STONE OR PAVERS
SLOPE AS REQUIRED
SAND SETTING BED
2" FOIL-FACED RIGID
INSULATION, HIGH
COMPRESSIVE
STRENGTH WHERE
REQUIRED
RADIANT TUBING
WHERE INDICATED
EXTERIOR
EXTERIOR RADIANT TUBING
WHERE INDICATED
T O P
REF TO PLANS
CLG. HEIGHT
REF TO
INTERIOR DOCS
WOOD FLOOR JOIST;
RE: STRUCT DWGS
PLYWOOD SHEATHING
RE: STRUCT DWGS
INTERIOR
FINISH CEILING
RE: INTERIOR DWGS
STONE OR PAVERS
SLOPE AS REQUIRED
MORTAR SETTING BED
3" POLYURETHANE FOAM
SPRAY; R 6.5 PER INCH
F2C.3
THICK SET STONE FLOORING
w/ SLOPED SLEEPERS OVER HABITABLE SPACE
DRAINAGE MAT/
PROTECTION BOARD
WATERPROOFING
MEMBRANE
TAPERED 2X SLEEPERS
SLOPED AS REQUIRED
W/ PLYWD DECK
CONTINUOUS
REINFORCED VAPOR
RETARDER
5/8" TYPE "X" GYPSUM
WALLBOARD
BLOW-IN BLANKET
INSULATION; R 3.7 PER
INCH
8" 3"
R-VALUE INSULATION
R6.5 x 3" =R19.5
R3.7 x 8" =R29.6
=R49.1
EXTERIOR
INTERIOR
POLYURETHANE FOAM
SPRAY INSULATION; R
6.5 PER INCH
R1A -1HR
ROOF
ROOF FRAMING,RE:
STRUCT DWGS
SELF-ADHERING SHEET
MEMBRANE
WATERPROOFING (2)
LAYERS GRACE ULTRA
PLYWOOD SHEATHING,
RE: STRUCT DWGS
2" SLOPED NAILABLE
RIGID INSULATION
5/8" TYPE "X" GYPSUM
WALLBOARD
12
VARIES
RE: ROOF
PLAN
VARIE S
ROOFING SYSTEM,
RE: ROOF PLAN
FINISH CEILING
RE: INTERIOR DWGS
R-VALUE INSULATION
R6.5 x 6" =R39
R6 x 2" =R12
=R51
6"
2"
PLYWOOD SHEATHING,
RE: STRUCT DWGS
5/8" TYPE "X" GYPSUM
WALLBOARD
STANDING SEAM ALUMINUM -
ANODIZED DARK BRONZE 12" WIDTHS
MANUFACTURUER TBD, COMPLIES
WITH UL-790 CLASS A FIRE RATING.
CONTINUOUS
REINFORCED VAPOR
RETARDER
R1D-IHR
EXTERIOR TO ACCOMPANY
R1A-1HR ON TIMBER RAFTERS
EXTERIOR
SELF-ADHERING SHEET
MEMBRANE
WATERPROOFING (2)
LAYERS GRACE ULTRA
PLYWOOD SHEATHING,
RE: STRUCT DWGS
2" SLOPED NAILABLE
RIGID INSULATION
PLYWOOD SHEATHING,
RE: STRUCT DWGS
12
VARIES
RE: ROOF
PLAN
ROOFING SYSTEM,
RE: ROOF PLAN
EXPOSED RAFTER ROOF
STRUCTURE; RE: STRUCT
DWGS
2X6 T&G WOOD SOFFIT
BOARDS
EXTERIOR
5/8" TYPE "X" GYPSUM
WALLBOARD
STANDING SEAM ALUMINUM -
ANODIZED DARK BRONZE 12" WIDTHS
MANUFACTURUER TBD, COMPLIES
WITH UL-790 CLASS A FIRE RATING.
R1C-IHR
EPDM OR TPO ROOF
INTERIOR
EXTERIOR
ROOF STRUCTURE RE:
STRUCT DWGS
PLYWOOD SHEATHING,
RE: STRUCT DWGS
2" FOIL-FACED, RIGID
INSULATION WHERE
REQ'D
DRAINAGE MAT/
PROTECTION BOARD
RE: INTERIOR DWGS
FOR FINISH
POLYURETHANE FOAM
SPRAY INSULATION; R
6.5 PER INCH
ADHESIVE
THERMOPLASTIC-POLYOLEFIN
ROOFING
5/8" TYPE "X" GYPSUM
WALLBOARD
CONTINUOUS
REINFORCED VAPOR
RETARDER
5/8" TYPE "X" GYPSUM
WALLBOARD
T O P
REF TO PLANS
CLG. HEIGHT
REF TO
INTERIOR DOCS
2 1/8" 6" R-VALUE INSULATION
R6.5 x 6" =R39
R6 x 2" =R12
=R51
SLOPE & ROOF
DRAINS NOT SHOWN
ON DETAIL; REFER TO
ROOF PLAN A-102 &
DETAILS A-404
CONNECTION TO STANDING
SEAM METAL ROOFING AS
SPECIFIED BY MANUFACTURE:
REFER ROOF PLAN FOR SNOW
FANCE LOCATIONS
EXTERIOR
EXTERIOR
T O P
REF TO PLANS
TIMBER DECK JOISTS
RE: STRUCT DWGS
WATERPROOFING
MEMBRANE
PLYWOOD SHEATHING
RE: STRUCT DWGS
T&G DECKING
RE: TO STRUCT DWGS
DRAINAGE MAT/
PROTECTION BOARD
RADIANT TUBING
WHERE INDICATED
MORTAR SETTING BED
STONE OR PAVERS
SLOPE AS REQUIRED
F4C-1HR
THICK SET STONE FLOORING ON TAPERED 2X
SLEEPER w/ INSULATION ON TIMBER STRUCTURE
TAPERED 2X SLEEPERS
SLOPED AS REQUIRED
W/ PLYWD DECK
5/8" TYPE "X" GYPSUM
WALLBOARD
NOTE:
EXPOSED TIMBERS AND
DECKING MEETS EAGLE
COUNTY WILDFIRE
HAZARD REQUIREMENTS.
EXTERIOR
EXTERIOR
RADIANT TUBING
WHERE REQUIRED
T O P
REF TO PLANS
WOOD FLOOR JOIST;
RE: STRUCT DWGS
PLYWOOD SHEATHING
RE: STRUCT DWGS
3" POLYURETHANE FOAM
SPRAY; R 6.5 PER INCH
2X6 T&G WOOD SOFFIT
BOARDS
WATERPROOFING
MEMBRANE
DRAINAGE MAT/
PROTECTION BOARD
STONE OR PAVERS
SLOPE AS REQUIRED
MORTAR SETTING BED
F2C.4 1HR
THICK SET STONE FLOORING ON TAPERED 2X SLEEPERS
INSULATION ON WOOD JOISTS w/ SOFFIT OVER EXTERIOR SPACE
TAPERED 2X SLEEPERS
SLOPED AS REQUIRED
W/ PLYWD DECK
CRINKLE BUILDING
WRAP
5/8" TYPE X, MOLD AND
MOISTURE RESISTANT,
FIRE-RESISTANT CORE
5/8" TYPE X, MOLD AND
MOISTURE RESISTANT,
FIRE-RESISTANT CORE
UNIT 9 ROOF AND
WALL CONDITION TO
BE COORDINATED
W2K-SIM
R1A-1HR
W2B
SIM
STANDING SEAM ALUMINUM -
ANODIZED DARK BRONZE 12"
WIDTHS
MANUFACTURUER TBD,
COMPLIES WITH UL-790
CLASS A FIRE RATING.
METAL SIDING
1" CONTINUOUS RIGID
INSULATION (R-5 PER
INCH)
5/8" TYPE X, MOLD AND
MOISTURE RESISTANT,
FIRE-RESISTANT CORE
5/8" TYPE X, MOLD AND
MOISTURE RESISTANT,
FIRE-RESISTANT CORE
5/8" TYPE X, MOLD AND
MOISTURE RESISTANT,
FIRE-RESISTANT CORE
LEVEL 2
8167' - 5"
LEVEL 3
8177' - 10"
LEVEL 4
8188' - 5"
LEVEL 5
8199' - 10"
2
A-302
5
A-404
W2A-1HR
SIM
W2A-1HR
W2C-1HR
FF4
FF6
FF4
FF4
R1D-1HR R1A-1HR
W2C
SIM
F2A 9' - 5" 1' - 0" 9' - 7" 1' - 0" 10' - 5" 1' - 0" 7' - 2"
F2A
F2A
F1A
REC / BUNK ROOM
BEDROOM #3
FAMILY / DINING
WALK-IN
CLOSET
BLOW-IN BLANKET
INSULATION; R 3.7 PER
INCH
1X6 RECLAIMED WOOD
WALL CLADDING
5/8" TYPE "X" GYPSUM
WALLBOARD
4" STONE VENEER;
ANCHORED TO
STRUCTURE AS REQD
7 1/4"
POLYURETHANE FOAM
SPRAY INSULATION; R
6.5 PER INCH
2X6 T&G WOOD ROOF
DECKING
BLOW-IN BLANKET
INSULATION; R 3.7 PER
INCH
BLOW-IN BLANKET
INSULATION; R 3.7 PER
INCHBLOW-IN BLANKET
INSULATION; R 3.7 PER
INCH
BLOW-IN BLANKET INSULATION; R
3.7 PER INCH
BLOW-IN BLANKET
INSULATION; R 3.7 PER
INCH
2" POLYURETHANE FOAM
SPRAY; R 6.5 PER INCH
2" POLYURETHANE FOAM
SPRAY; R 6.5 PER INCH
2" POLYURETHANE FOAM
SPRAY; R 6.5 PER INCH
2" FOIL-FACED, RIGID
INSULATION WHERE
REQ'D
1" CONTINUOUS RIGID
INSULATION (R-5 PER
INCH)
2" FOIL-FACED, RIGID
INSULATION WHERE
REQ'D
HOT FLUID-APPLIED
RUBBERIZED ASPHALT
WATERPROOFING TO 18"
A.F. GRADE
---
-
A-404
4
CONCRETE FOOTING, RE:
STRUCTURAL DWGS
CONTINUOUS
REINFORCED VAPOR
RETARDER
TWO POLE SNOW GUARD
STONE FLOORING
MASONRY MORTAR
3/16" ACOUSTIC
UNDERLAYMENT
3/4" WOOD FLOORING
1-1/2" GYPSUM CONCRETE
TOPPING
FLOOR FINISH VARIES;
RE: INTERIOR DWGS
1-1/2" GYPSUM CONCRETE
TOPPING
3/16" ACOUSTIC
UNDERLAYMENT
SHEET CARPETING
1-1/2" GYPSUM CONCRETE
TOPPING
3/16" ACOUSTIC
UNDERLAYMENT
3/16" ACOUSTIC
UNDERLAYMENT
FF4
FF5 FF3
FF6
PROJECT:
SHEPHERD RESOURCES INC/AIA
970 949 3302
M
O C . T C E T I H R A I R
P B OX 8 40
105 EDWAR DS BLVD
O ST FFI C E O
S U I T E C103
E D W A R DS C O 81 6 3 2
V I LLAGE
A-400
1408.04
AUGUST 31, 2017
LOT 10
303 GORE CREEK
DRIVE
GALVIN
RESIDENCE
PERMIT REVISIONS
TYPICAL WALL SECTION,
ROOF & FLOOR TYPES
SCALE: 1 1/2" = 1'-0"
FLOOR TYPES
DATE ISSUE
02/20/2017 DRB Final Review
05/15/2017 DRB Modification to Approved Plans
07/21/2017 Permit
8/31/2017 Permit Review Comments
4
SCALE: 1 1/2" = 1'-0"
ROOF TYPES
NO SCALE
STANDING SEAM SNOW FENCE
SCALE: 1 1/2" = 1'-0"
2
ROOF AT PARTY WALL
SCALE: 3/4" = 1'-0"
1
TYPICAL WALL SECTION
NO SCALE
FINISH FLOOR TYPES
10/04/17