Loading...
HomeMy WebLinkAboutB17-0285_A-401_1507158104.pdfEXTERIOR INTERIOR NOTE: WATERPROOFING MEMBRANE AT ALL WALLS BELOW FINISHED GRADE REINFORCED CONCRETE WALL, RE: STRUCTURAL DWGS HOT FLUID-APPLIED RUBBERIZED ASPHALT WATERPROOFING TO 18" A.F. GRADE 2" INSULATED DRAINAGE BOARD (R-10) W1A CONCRETE WALL RE: STRUCT DWGS EXTERIOR REINFORCED CONCRETE WALL, RE: STRUCTURAL DWGS 2" INSULATED DRAINAGE BOARD (R-10) W1B CONCRETE WALL W/ FURRING WATERPROOFING MEMBRANE TO 18" MIN. ABOVE FINISH GRADE (2) LAYERS AIR INFILTRAION BARRIER ABOVE CONTINUOUS REINFORCED VAPOR RETARDER RE: PLANS RE: STRUCT DWGS RE: INTERIOR DWGS FOR FINISH BLANKET (BATT) INSULATION 2X FURRING RE:PLANS FOR DEPTH INTERIOR NOTE: WATERPROOFING MEMBRANE AT ALL WALLS BELOW FINISHED GRADE EXTERIOR EXTERIOR W1C CONCRETE WALL W/ STONE VENEER REINFORCED CONCRETE WALL, RE: STRUCTURAL DWGS 1/2" INSULATED DRAINAGE BOARD MORTAR SETTING BED STONE VENEER; ANCHORED TO STRUCTURE AS REQD WATERPROOFING MEMBRANE TO 18" MIN. ABOVE FINISH GRADE (2) LAYERS AIR INFILTRAION BARRIER ABOVE RE: STRUCT DWGS MASONRY TIES AS REQ'D WEEP HOLES AS REQ'D HOT FLUID-APPLIED RUBBERIZED ASPHALT WATERPROOFING TO 18" A.F. GRADE 2" INSULATED DRAINAGE BOARD (R-10) EXTERIOR EXTERIOR W1C.1 CONCRETE WALL W/ STONE VENEER BOTH SIDES REINFORCED CONCRETE WALL, RE: STRUCTURAL DWGS 1/2" INSULATED DRAINAGE BOARD WATERPROOFING MEMBRANE TO 18" MIN. ABOVE FINISH GRADE (2) LAYERS AIR INFILTRAION BARRIER ABOVE RE: STRUCT DWGS NOTE: MATERIALS ARE SAME BOTH SIDES MASONRY TIES AS REQ'D WEEP HOLES AS REQ'D STONE VENEER; ANCHORED TO STRUCTURE AS REQD EXTERIOR INTERIOR REINFORCED CONCRETE WALL, RE: STRUCTURAL DWGS MORTAR SETTING BED DRAINAGE MAT/ PROTECTION BOARD RE: STRUCT DWGS 2X WOOD FRAMING RE: STRUCT DWGS RE: INTERIOR DWGS FOR FINISH W1C.2 CONCRETE WALL W/ STONE VENEER - 2x FURRING STONE VENEER; ANCHORED TO STRUCTURE AS REQD WATERPROOFING MEMBRANE TO 18" MIN. ABOVE FINISH GRADE (2) LAYERS AIR INFILTRAION BARRIER ABOVE BLANKET (BATT) INSULATION INTERIOR EXTERIOR REINFORCED CONCRETE WALL, RE: STRUCTURAL DWGS 1/2" INSULATED DRAINAGE BOARD MORTAR SETTING BED RE: STRUCT DWGS 2X WOOD FRAMING RE: STRUCT DWGS RE: INTERIOR DWGS FOR FINISH 1/2" RESILIENT CHANNEL; CLARK DIETRICH OR APPROVED EQUAL W1C.3 CONCRETE WALL - STONE VENEER - RESILIENT CHANNEL STONE VENEER; ANCHORED TO STRUCTURE AS REQD BLANKET (BATT) INSULATION EXTERIOR INTERIOR REINFORCED CONCRETE WALL, RE: STRUCTURAL DWGS 1 1/2" RIGID INSULATION 2X FURRING RE:PLANS FOR DEPTH W1F CONCRETE - WOOD SIDING RE: STRUCT DWGS WOOD SIDING EXTERIOR INTERIOR W2A WOOD FRAMING w/ WOOD SIDING RE: INTERIOR DWGS FOR FINISH BLOW-IN BLANKET INSULATION; R 3.7 PER INCH 2X6 WOOD FRAMING RE: STRUCT DWGS PLYWOOD SHEATHING RE: STRUCT DWGS 1.25" RIGID MINERAL WOOL INSULATION SHEATHING BOARD; R-5 PER INCH CRINKLE BUILDING WRAP WOOD SIDING RE: STRUCT DWGS EXTERIOR INTERIOR W2B WOOD FRAMING w/ METAL SIDING BLOW-IN BLANKET INSULATION; R 3.7 PER INCH 2X6 WOOD FRAMING RE: STRUCT DWGS PLYWOOD SHEATHING RE: STRUCT DWGS 1.25" RIGID MINERAL WOOL INSULATION SHEATHING BOARD; R-5 PER INCH CRINKLE BUILDING WRAP 5 1/2" RE: STRUCT DWGS METAL SIDING RE: INTERIOR DWGS FOR FINISH EXTERIOR INTERIOR W2C WOOD FRAMING w/ STONE VENEER BLOW-IN BLANKET INSULATION; R 3.7 PER INCH 2X6 WOOD FRAMING RE: STRUCT DWGS PLYWOOD SHEATHING RE: STRUCT DWGS 1.25" RIGID MINERAL WOOL INSULATION SHEATHING BOARD; R-5 PER INCH CRINKLE BUILDING WRAP 5 1/2" RE: STRUCT DWGS RE: INTERIOR DWGS FOR FINISH STONE VENEER; ANCHORED TO STRUCTURE AS REQD MORTAR SETTING BED WEEP HOLES AS REQ'D MASONRY TIES AS REQ'D EXTERIOR EXTERIOR W2C.1 WOOD FRAMING w/ STONE VENEER - BOTH SIDES BLOW-IN BLANKET INSULATION; R 3.7 PER INCH 2X6 WOOD FRAMING RE: STRUCT DWGS PLYWOOD SHEATHING RE: STRUCT DWGS 1.25" RIGID MINERAL WOOL INSULATION SHEATHING BOARD; R-5 PER INCH CRINKLE BUILDING WRAP RE: STRUCT DWGS STONE VENEER; ANCHORED TO STRUCTURE AS REQD MORTAR SETTING BED WEEP HOLES AS REQ'D VAPOR BARRIER W2I 2x4 WOOD FRAMING w/ GWB BOTH SIDES INTERIOR INTERIOR FULL DEPTH NATURAL FIBER SOUND BATT INSULATION 5/8" TYPE "X" GYPSUM WALLBOARD 2X WOOD FRAMING RE: STRUCT DWGS W2I.1 2x2 WOOD FRAMING w/ GWB BOTH SIDES INTERIOR INTERIOR 5/8" TYPE "X" GYPSUM WALLBOARD 2X4 LAID FLAT W2I.2 2x6 WOOD FRAMING w/ GWB BOTH SIDES INTERIOR INTERIOR 5/8" TYPE "X" GYPSUM WALLBOARD 2X6 WOOD FRAMING RE: STRUCT DWGS 5/8" TYPE "X" GYPSUM WALLBOARD FULL DEPTH NATURAL FIBER SOUND BATT INSULATION W2K 2x4 WOOD FRAMING - GWB INTERIOR INTERIOR FULL DEPTH NATURAL FIBER SOUND BATT INSULATION 2X WOOD FRAMING RE: STRUCT DWGS 5/8" TYPE "X" GYPSUM WALLBOARD W2L 2x4 WOOD FRAMING 2-LAYERS GWB INTERIOR INTERIOR FULL DEPTH NATURAL FIBER SOUND BATT INSULATION 2X WOOD FRAMING RE: STRUCT DWGS 5/8" TYPE "X" GYPSUM WALLBOARD (2) LAYERS 2X6 WOOD FRAMING RE: STRUCT DWGS 5/8" TYPE "X" GYPSUM WALLBOARD MORTAR-BED TILING CERAMIC TILE W2O WOOD FRAMING w/ 1/4" TILE RE: INTERIOR DWGS FOR FINISH WALL NOTES: WHEN GWB IS INDICATED ON INTERIORS DRAWINGS, STANDARD WALLS SHALL BE TYPE X". DAMP LOCATIONS REQUIRE GREENBOARD. WET LOCATIONS REQUIRE GREENBOARD. WET LOCATIONS REQUIRE CEMENT BOARD. SILL GASKET TYPICAL AT BASE OF WALL INTERIOR INTERIOR FULL DEPTH NATURAL FIBER SOUND BATT INSULATION PROJECT: SHEPHERD RESOURCES INC/AIA 970 949 3302 M O C . T C E T I H R A I R P B OX 8 40 105 EDWAR DS BLVD O ST FFI C E O S U I T E C103 E D W A R DS C O 81 6 3 2 V I LLAGE A-401 1408.04 AUGUST 31, 2017 LOT 10 303 GORE CREEK DRIVE GALVIN RESIDENCE PERMIT REVISIONS WALL TYPES SCALE: 1 1/2" = 1'-0" TYPICAL EXTERIOR & INTERIOR WALL TYPES DATE ISSUE 02/20/2017 DRB Final Review 05/15/2017 DRB Modification to Approved Plans 07/21/2017 Permit 8/31/2017 Permit Review Comments 10/04/17