Loading...
HomeMy WebLinkAboutB17-0285_A-800_1507155420.pdfWINDOW NOTES #1 - PROVIDE WINDOW OPERATION CONTROL DEVICES WITH FALL PROJECTION R312.2 TO MEET CODE COMPLIANCE. #2 - ALL BROMBAL WINDOWS AND DOORS ARE DESIGNED WITH TEMPERED GLAZING. #3 - EGRESS WINDOW WILL MEET 5.7 SQ FT, HARDWARE WILL ALLOW WINDOW OPENING AND OPERATION TO MEET CODE COMPLIANCE. PROJECT: SHEPHERD RESOURCES INC/AIA 970 949 3302 M O C . T C E T I H R A I R P B OX 8 40 105 EDWAR DS B LVD OST FF I C E O S U I T E C103 E D W A R DS CO 81 6 3 2 V I LLAGE A-800 1408.04 AUGUST 31, 2017 LOT 10 303 GORE CREEK DRIVE GALVIN RESIDENCE PERMIT REVISIONS SCHEDULES INTERIOR DOOR SCHEDULE MARK ROOM OPERATION WIDTH HEIGHT DOOR THICKNESS FIRE RATING COMMENTS LEVEL 1 101 STORAGE HINGED 3' - 0" 5' - 0" 1 3/4" 3/4 HR SELF CLOSING HINGES 102 STORAGE HINGED 3' - 0" 5' - 6" 1 3/4" 3/4 HR SELF CLOSING HINGES 103 STORAGE HINGED 3' - 0" 5' - 6" 1 3/4" 3/4 HR SELF CLOSING HINGES LEVEL 2 201 HALL HINGED 2' - 10" 7' - 6" 1 3/4" 3/4 HR SELF CLOSING HINGES 202 HALL HINGED 2' - 8" 7' - 6" 1 3/4" 203 BEDROOM #2 HINGED 2' - 4" 7' - 6" 1 3/4" 204 TLT #2 HINGED 2' - 4" 7' - 6" 1 3/4" 205 CLOSET #2 WALL HUNG SLIDING 2' - 8" 7' - 6" 1 3/4" 206 HALL HINGED 2' - 8" 7' - 6" 1 3/4" 207 BATH #1 POCKET 2' - 4" 7' - 6" 1 3/4" 208 HALL HINGED 3' - 0" 7' - 6" 1 3/4" 209 REC / BUNK ROOM HINGED 2' - 8" 7' - 6" 1 3/4" 210 CLOSET WALL HUNG SLIDING 2' - 4" 7' - 6" 1 3/4" 211 TLT #1 HINGED 2' - 0" 7' - 6" 1 3/4" LEVEL 3 301 SKI ROOM HINGED 2' - 8" 7' - 6" 1 3/4" 302 POWDER #1 HINGED 2' - 4" 7' - 6" 1 3/4" 303 LAUNDRY #2 HINGED 2' - 8" 7' - 6" 1 3/4" 304 HALL HINGED PAIR 4' - 0" 7' - 6" 1 3/4" 305 HALL HINGED 3' - 0" 7' - 6" 1 3/4" 306 BEDROOM #3 HINGED 2' - 8" 7' - 6" 1 3/4" 307 BATH #3 HINGED 2' - 4" 7' - 6" 1 3/4" 308 TLT #3 POCKET 2' - 4" 7' - 6" 1 3/4" 309 CLOSET #3 POCKET 2' - 6" 7' - 0" 1 3/4" LEVEL 4 401 KITCHEN STORED BI-FOLD 3' - 8" 7' - 6" 1 3/8" 402 KITCHEN HINGED 3' - 0" 7' - 6" 1 3/4" LEVEL 5 501 HALL HINGED 2' - 8" 7' - 0" 1 3/4" 502 BATH #4 POCKET 2' - 4" 7' - 0" 1 3/4" 503 TLT #4 POCKET 2' - 4" 7' - 0" 1 3/4" 504 HALL HINGED 2' - 6" 7' - 0" 1 3/4" 505 HALL HINGED 3' - 0" 7' - 0" 1 3/4" 506 MASTER BEDROOM HINGED 2' - 8" 7' - 0" 1 3/4" 507 MASTER BEDROOM HINGED 2' - 6" 7' - 0" 1 3/4" 508 TLT POCKET 2' - 4" 7' - 0" 1 3/4" 509 MASTER BEDROOM HINGED 2' - 6" 6' - 8" 1 3/4" 510 WALK-IN CLOSET HINGED 2' - 6" 6' - 8" 1 3/4" MILLWORK DOOR SCHEDULE MARK ROOM OPERATION WIDTH HEIGHT THICKNESS COMMENTS LEVEL 2 MW1 REC / BUNK ROOM HINGED 2' - 4" 7' - 6" 1" MW3 TLT #1 HINGED PAIR 2' - 0" 7' - 0" 1" MW2 REC / BUNK ROOM HINGED 2' - 4" 7' - 6" 1" LEVEL 4 MW4 KITCHEN HINGED 1' - 6" 7' - 6" 1" BUILT IN CUSTOM CABINETS MW5 KITCHEN HINGED 1' - 6" 7' - 6" 1" BUILT IN CUSTOM CABINETS LEVEL 5 MW6 CLOSET HINGED PAIR 3' - 0" 7' - 0" 1" BUILT IN CUSTOM CABINETS EXTERIOR DOOR SCHEDULE MARK ROOM OPERATION MANUFACTURER WIDTH HEIGHT THICKNESS SAFETY GLAZING U-VALUE SOLAR HEAT GAIN COEFFCIENT FIRE RATING COMMENTS LEVEL 2 D01 HINGED TBD 3' - 0" 6' - 8" 2" Yes 0.2200 BTU/(h·ft ·°F) 1 HR GLAZING TO BE FIRELITE LEVEL 3 D02 ENTRY HINGED BROMBAL 3' - 0" 7' - 6" 2" Yes 0.2200 BTU/(h·ft ·°F) D03 SKI ROOM HINGED BROMBAL 3' - 0" 7' - 6" 2" Yes 0.2200 BTU/(h·ft ·°F) D04 TRASH CLOSET HINGED CUSTOM 3' - 0" 7' - 0" 1 3/4" No D05 ELEC CL HINGED PAIR CUSTOM 4' - 8" 7' - 0" 1 3/4" No 3/4 HR D06 HINGED CUSTOM 3' - 0" 7' - 0" 1 3/4" No EXTERIOR GEAR STORAGE LEVEL 4 D07 LIVING ROOM LIFT & SLIDE BROMBAL 13' - 0" 9' - 0" 2" Yes .26 0.3900 BTU/(h·ft ·°F) D08 FAMILY / DINING LIFT & SLIDE BROMBAL 13' - 0" 9' - 0" 2" Yes .26 0.3900 BTU/(h·ft ·°F) LEVEL 5 D09 FAMILY/OFFICE LIFT & SLIDE BROMBAL 12' - 0" 8' - 0" 2" Yes .26 0.3900 BTU/(h·ft ·°F) WINDOW SCHEDULE MARK ROOM OPERATION / VENTILATION WIDTH HEIGHT EGRESS MANUFACTURER HEAD HEIGHT SILL HEIGHT SAFETY GLAZING U-VALUE SOLAR HEAT GAIN COEFFCIENT COMMENTS LEVEL 2 201 REC / BUNK ROOM CASEMENT 3' - 0" 4' - 6" Yes Brombal 8' - 0" 3' - 6" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #2, #3 202 REC / BUNK ROOM FIXED 4' - 8" 4' - 6" Brombal 8' - 0" 3' - 6" Yes .19 0.3200 BTU/(h·ft ·°F) NOTE #2 203 REC / BUNK ROOM CASEMENT 3' - 0" 4' - 6" Yes Brombal 8' - 0" 3' - 6" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #2, #3 204 BEDROOM #2 CASEMENT 3' - 8" 6' - 0" Yes Brombal 8' - 0" 2' - 0" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #2, #3 LEVEL 3 301 SKI ROOM CASEMENT 2' - 0" 2' - 8" Brombal 7' - 2" 4' - 6" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #2 302 BEDROOM #3 CASEMENT 3' - 0" 7' - 4" Yes Brombal 8' - 2" 10" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #1, #2, #3 303 BEDROOM #3 FIXED 4' - 8" 7' - 4" Brombal 8' - 2" 10" Yes .19 0.3200 BTU/(h·ft ·°F) NOTE #2 304 BEDROOM #3 CASEMENT 3' - 0" 7' - 4" Yes Brombal 8' - 2" 10" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #1, #2, #3 LEVEL 4 401 KITCHEN FIXED 7' - 8" 6' - 0" Brombal 9' - 4" 3' - 4" Yes .19 0.3200 BTU/(h·ft ·°F) INTERIOR WINDOW - CUSTOM LEVEL 5 501 MASTER BEDROOM CASEMENT 4' - 8" 5' - 10" Yes Brombal 6' - 10" 1' - 0" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #1, #2, #3 502 WALK-IN CLOSET CASEMENT 2' - 6" 3' - 4" Brombal 6' - 6" 3' - 2" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #2 503 MASTER BEDROOM CASEMENT 4' - 8" 5' - 10" Yes Brombal 6' - 10" 1' - 0" Yes .24 0.3300 BTU/(h·ft ·°F) NOTE #1, #2, #3 504 FAMILY/OFFICE FIXED 6' - 0" 3' - 0" Brombal 11' - 8" 8' - 8" Yes .19 0.3200 BTU/(h·ft ·°F) NOTE #2 505 FAMILY/OFFICE FIXED 6' - 0" 3' - 0" Brombal 11' - 8" 8' - 8" Yes .19 0.3200 BTU/(h·ft ·°F) NOTE #2 506 FAMILY/OFFICE FIXED 3' - 0" 6' - 6" Brombal 7' - 2 1/2" 8 1/2" Yes N/A 0.0000 BTU/(h·ft ·°F) INTERIOR WINDOW DATE ISSUE 02/20/2017 DRB Final Review 05/15/2017 DRB Modification to Approved Plans 07/21/2017 Permit 8/31/2017 Permit Review Comments 4 NO SCALE LIGHT & VENTILATION CALCULATIONS 10/04/17