Loading...
HomeMy WebLinkAboutB17-0285_F-100_1507158106.pdf1 2 3 7 F-100 2HR FIRE RATING W1A CRAWLSPACE 1 2 3 7 F-100 REC / BUNK ROOM BATH #1 BEDROOM #2 HALL ELEVATOR LAUNDRY #1 BATH #2 CLOSET #2 CLOSET W2C-1HR W2C SIM 1' - 2 1/2" 9 F-100 DOOR D01 1 HR RATED 1 2 3 BEDROOM #3 SKI ROOM CLOSET #3 ELEVATOR BATH #3 TLT #3 SHWR #3 LAUNDRY #2 POWDER #1 ENTRY HALL TRASH CLOSET ELEC CL 7 F-100 W2C-1HR W2C-1HR 18" +12' - 0 1/4" 9 F-100 10 F-100 CANOPY PROJECTION 1 HR RATED 1HR FIRE RATING 1HR FIRE RATING 1 2 3 7 F-100 FAMILY / DINING KITCHEN LIVING ROOM ELEVATOR W2C-1HR W2A-1HR SIM 9 F-100 10 F-100 1HR FIRE RATING 1 2 3 7 F-100 MASTER BEDROOM FAMILY/OFFICE BATH #4 MASTER BATH WALK-IN CLOSET ELEVATOR CLOSET HALL LINEN TLT #4 W2A-1HR W2A-1HR 9 F-100 10 F-100 1 2 3 7 F-100 7 F-100 9 F-100 10 F-100 2HR RATED PARTY WALL TO UNDERSIDE OF ROOF DECKING PER CODE STANDING SEAM ALUMINUM - ANODIZED DARK BRONZE 12" WIDTHS MANUFACTURUER TBD, COMPLIES WITH UL- 790 CLASS A FIRE RATING. R1A-1HR R1A-1HR R1A-1HR R1A-1HR R1C-1HR R1C-1HR 1 HR 2HR RATED WALLS NOTE: LEVEL 2 DOOR D01 & CANOPY PROJECTION SHALL HAVE A 1HR FIRE- RESISTANCE RATING. DOOR GLAZING TO BE FIRELITE AND 1 HR RATING. LEVEL 2 8167' - 5" LEVEL 3 8177' - 10" LEVEL 4 8188' - 5" LEVEL 5 8199' - 10" LEVEL 1 8160' - 8" 1 2 3 2HR RATED PARTY WALL TO UNDERSIDE OF ROOF DECKING PER CODE STANDING SEAM ALUMINUM - ANODIZED DARK BRONZE 12" WIDTHS MANUFACTURUER TBD, COMPLIES WITH UL-790 CLASS A FIRE RATING. EXTERIOR INTERIOR 1HR RATED - SIM W2A, W2B W2C WOOD FRAMING WITH APPLIED SIDING RE: INTERIOR DWGS FOR FINISH BLOW-IN BLANKET INSULATION; R 3.7 PER INCH 2X6 WOOD FRAMING RE: STRUCT DWGS PLYWOOD SHEATHING RE: STRUCT DWGS 1.25" RIGID MINERAL WOOL INSULATION SHEATHING BOARD; R-5 PER INCH CRINKLE BUILDING WRAP 5/8" 5/8" 5/8" TYPE "X" GYPSUM WALLBOARD 5/8" TYPE "X" GYPSUM WALLBOARD RE: STRUCT DWGS FINISH SIDING MATERIAL; REFER TO WALL TYPES LEVEL 3 8177' - 10" LEVEL 4 8188' - 5" LEVEL 5 8199' - 10" 1 2 3 DOOR D01 & PROJECTION CANOPY 1 HR RATED LEVEL 3 8177' - 10" LEVEL 4 8188' - 5" LEVEL 5 8199' - 10" 1 2 INTERIOR REINFORCED CONCRETE WALL, RE: STRUCTURAL DWGS 2HR CONCRETE PARTY WALL W/ UNIT STUD WALLS VAPOR BARRIER RE: PLANS RE: STRUCT DWGS AT PARTY WALL ADJOINING TOWNHOME 5/8" TYPE "X" GYPSUM WALLBOARD BLOW-IN BLANKET INSULATION; R 3.7 PER INCH INTERIOR 5/8" TYPE "X" GYPSUM WALLBOARD PROJECT: SHEPHERD RESOURCES INC/AIA 970 949 3302 M O C . T C E T I H R A I R P B OX 8 40 105 EDWAR DS BLVD O ST FFI C E O S U I T E C103 E D W A R DS C O 81 6 3 2 V I LLAGE F-100 1408.04 AUGUST 31, 2017 LOT 10 303 GORE CREEK DRIVE GALVIN RESIDENCE PERMIT REVISIONS RATED WALL ASSEMBLIES SCALE: 1/8" = 1'-0" 1 LEVEL 1 FIRE RATING SCALE: 1/8" = 1'-0" 2 LEVEL 2 FIRE RATING SCALE: 1/8" = 1'-0" 3 LEVEL 3 FIRE RATING SCALE: 1/8" = 1'-0" 4 LEVEL 4 FIRE RATING SCALE: 1/8" = 1'-0" 5 LEVEL 5 FIRE RATING SCALE: 1/8" = 1'-0" 6 ROOF FIRE RATING SCALE: 1/8" = 1'-0" 7 RATED WALL SECTION SCALE: 1 1/2" = 1'-0" 1HR RATED EXTERIOR WALL TYPICAL SCALE: 1/8" = 1'-0" 9 NORTH ELEVATION - CREEK SIDE SCALE: 1/8" = 1'-0" 10 SOUTH ELEVATION - STREET SIDE SCALE: 1 1/2" = 1'-0" 2HR PARTY WALL TYPICAL DATE ISSUE 02/20/2017 DRB Final Review 05/15/2017 DRB Modification to Approved Plans 07/21/2017 Permit 8/31/2017 Permit Review Comments 10/04/17