HomeMy WebLinkAboutB17-0396_E1.0_1506985227.pdfH/P HEAT/PHOTOELECTRIC SMOKE DETECTOR ELECTRICAL LEGEND (NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT) RECESSED OR SURFACE DOWNLIGHT WALL MOUNTED LIGHT FIXTURE RECESSED FLUOR. LIGHT FIXTURE SURFACE FLUOR. LIGHT FIXTURE Aa Aa FIXTURE DESIGNATIONS: UPPER CASE - FIXTURE TYPE LOWER CASE - SWITCH DESIGNATION SHADING ON FIXTURE INDICATES EMERG. BATTERY BACKUP FLUORESCENT STRIP FIXTURE TRACK LIGHT AS NOTED OR SCHEDULED WALL WASHER POLE-MOUNTED FIXTURE POST (BOLLARD) FIXTURE CEILING OR WALL MOUNTED EXIT LIGHT EMERGENCY BATTERY LIGHTS DUPLEX RECEPTACLE @ 18" UNLESS NOTED DOUBLE DUPLEX RECEPTACLE @ 18" UNLESS NOTED SPECIAL OUTLET AS NOTED FLUSH FLOOR DUPLEX RECEPTACLE DUPLEX RECEPTACLE HALF-SWITCHED @ 18" UNLESS NOTED TELE-POWER POLE JUNCTION BOX IN FLOOR, CEILING OR IN WALL MULTI-OUTLET PLUG STRIP J J J COMPUTER/TELEPHONE OUTLET IN FLOOR OR WALL CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING TELEPHONE BACKBOARD CIRCUIT HOMERUN CONDUIT RUN BELOW FLOOR OR GRADE CONDUIT STUB-UP - CAP & MARK LIGHT SWITCH AT 46" UNLESS NOTED SUBSCRIPTS: 2 = 2-POLE SWITCH 3 = 3-WAY SWITCH 4 = 4-WAY SWITCH K = KEY-OPERATED SWITCH TO = THERMAL OVERLOAD SWITCH P = SWITCH WITH PILOT LIGHT DIMMER SWITCH W/ WATTAGE MAGNETIC MOTOR STARTER DISCONNECT SWITCH PANELBOARD OR LOAD CENTER, FLUSH OR SURFACE MOUNTED SWITCHBOARD, MOTOR CONTROL CENTER OR DISTRIBUTION BOARD TRANSFORMER GROUND PUSHBUTTON CONTROL STATION PHOTOELECTRIC CELL TIME SWITCH THERMOSTAT AT 60" UNLESS NOTED DIVISION 15 EQUIPMENT CIRCUIT BREAKER MOTOR OUTLET AUTOMATIC TRANSFER SWITCH FOOD SERVICE EQUIPMENT D T PC TS T M ATS ABBREVIATIONS - ABOVE COUNTER AC AFF - ABOVE FINISHED FLOOR - ABOVE FINISHED GRADE AFG - ALUMINUM AL - EMERGENCY EM - GROUND GND - GROUND FAULT INTERRUPTER GFI NIC - NOT IN CONTRACT NL - NIGHT LIGHT NTS - NOT TO SCALE UG - UNDERGROUND WP - WEATHER PROOF XFMR - TRANSFORMER +18" - MOUNTING HEIGHT TO CENTERLINE OF DEVICE AFF OR AFG FIRE ALARM SYSTEM FIRE ALARM CONTROL PANEL ANN FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM PULL STATION ALARM HORN OR SPEAKER COMBINATION HORN/STROBE OR SPEAKER/STROBE THERMAL HEAT DETECTOR H SMOKE/IONIZATION DETECTOR I PHOTOELECTRIC SMOKE DETECTOR P DUCT DETECTOR S R SPRINKLER SYSTEM FLOW SWITCH SPRINKLER SYSTEM TAMPER SWITCH STROBE SMOKE/FIRE DAMPER CONNECTION REMOTE INDICATOR LIGHT F D COMMUNICATION SYSTEM SPEAKER IN CEILING OR WALL VOLUME CONTROL AT 60" UNLESS NOTED MICROPHONE OUTLET IN FLOOR BOX OR WALL M M CALL-IN SWITCH C PROGRAM BELL INTERCOM CLOCK V I S S B A AMPLIFIER TELEVISION OUTLET CONTACT DOOR SWITCH IN JAMB OR HINGE SECURITY SYSTEM DC INTRUSION MOTION DETECTOR AS SPECIFIED, CORRIDOR/ROOM P C OR R KEY-OPERATED ACCESS SWITCH K SURVEILLANCE CAMERA DISTRIBUTION EQUIPMENT SYMBOLS DISCONNECT SWITCH FUSES CIRCUIT BREAKER CURRENT TRANSFORMER TRANSFORMER METER M CU - COPPER STEP LIGHT FACP M = MOTION-OPERATED SWITCH POP-UP RECEPTACLE - ELECTRICAL CONTRACTOR EC - AUTHORITY HAVING JURISDICTION AHJ - MECHANICAL CONTRACTOR MC - PLUMBING CONTRACTOR PC UTP - UNSHIELDED TWISTED PAIR - GENERAL CONTRACTOR GC - REFERENCE REF 1. WALL ASSEMBLY - THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 HR FIRE RATED ASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16 IN. (406 MM) OC WITH NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM) WIDE BY 1-3/8 IN. (35 MM) DEEP CHANNELS SPACED MAX 24 IN. (610 MM) OC. B. GYPSUM BOARD* - NOM 1/2 OR 5/8 IN. (13 OR 16 MM) THICK, 4 FT. (122 CM) WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 26 IN. (660 MM). 2. THROUGH PENETRANT - ONE CONDUIT INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM) (POINT CONTACT) TO MAX 2 IN. (51 MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: A. CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) STEEL CONDUIT OR NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING 3. FILL,VOID OR CAVITY MATERIAL* - CAULK OR SEALANT - MIN 5/8. 1-1/4,1-7/8 AND 2-1/2 IN. (16, 32, 48 AND 64 MM) THICKNESS OF CAULK FOR 1, 2, 3 AND 4 HR RATED ASSEMBLIES, RESPECTIVELY, APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. MIN 1/4 IN. (6 MM) DIAM BEAD OF CAULK APPLIED TO GYPSUM BOARD/PENETRANT INTERFACE AT POINT CONTACT LOCATION ON BOTH SIDES OF WALL. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS SHOWN IN THE FOLLOWING TABLE. THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS TABULATED TO THE LEFT. 3M COMPANY - CP 25WB+ CAULK OR FB-3000 WT SEALANT, *BEARING THE UL CLASSIFICATION MARKING PENETRATION THROUGH A FIRE-RATED WALL D T J 18"(1'6") 46"(3'10") 48"(4'-0") 80"(6'8") TYPICAL DEVICE MOUNTING HEIGHTS MAIN CIRCUIT BREAKER & BRANCH CIRCUIT BREAKERS MAXIMUM MOUNTING HEIGHT IS 79", MINIMUM IS 18". GENERAL NOTES ALL SHEETS THE ELECTRICAL CONTRACTOR WILL PROVIDE A WALK THROUGH WITH THE OWNER/ARCHITECT PRIOR TO FINAL ROUGHIN AS FOLLOWS: · CONFIRM ALL LOCATIONS FOR LIGHT SWITCHES; ADD THREE WAYS IF FOUND NECESSARY. · REVIEW RECEPTACLE LOCATIONS; MOVE AS REQUIRED. PROVIDE UNIT PRICING IF ADDITIONAL RECEPTACLES ARE REQUIRED. · REVIEW RECEPTACLE LOCATIONS AT COUNTERS AND CONFIRM IF THOSE RECEPTACLES SHOULD BE ABOVE COUNTER OR BELOW. MOVE AS REQUIRED. IN GENERAL CONFIRM POWER AND LIGHTING REQUIREMENTS. THE ELECTRICIAN SHOULD BE PREPARED TO REWORK SOME DEVICE LOCATIONS. SIGNIFICANT REWORK SHOULD BE FLAGGED AND UNIT PRICING PROVIDED AND WRITTEN AUTHORIZATION FOR ADDITIONAL COSTS APPROVED PRIOR TO PROCEEDING. UNO - UNLESS NOTED OTHERWISE NOT TO SCALE NOTES: 1. HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE. 2. DEVICES ABOVE DOORS SHALL BE CENTERED BETWEEN TOP OF DOOR TRIM AND CEILING LINE. 3. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS AND NOTED ON ELECTRICAL FLOOR PLANS SHALL GOVERN OVER THOSE SHOWN ABOVE. 4. FOR CEILING HEIGHTS HIGHER THAN 7'2", INSTALL FIRE ALARM NOTIFICATION AUDIO AND VISUAL APPLIANCES AT 80"AFF OTHERWISE INSTALL AT 6" BELOW CEILING. 5. MOUNTING HEIGHTS PER IBC 2009 AND ADA CODES NOT TO SCALE FINISHED FLOOR TYPICAL 8'0" CEILING CEILING MOUNT MOTION SENSOR M electrical apparatus as shown on single line diagram and Complete provision, installation and connection of lighting fixtures, exit signs and lamps as specified and as shown on drawings. Complete branch circuit wiring required for the connection of emergency lighting and exit signs to existing emergency stand Complete feeder(s) installation as required for new and/or devices, new control devices, etc. for a complete lighting and including new panelboards, new conduits, new wires, new wiring Complete wiring system for new lighting and power as shown, contract. Electrical work shall include, but not limited to, these major as indicated on drawing and as specified, as necessary to complete the SCOPE: Furnish all materials and labor required to execute this work 2. A. ELECTRICAL SPECIFICATIONS 1. drawings. by power system. and power system. b. a. items: A. Contractor shall submit shop drawings for engineer review and approval. Lighting fixtures. Shop drawing submittal shall include: Panelboard(s). CONDUIT AND WIRE: B. 13. A. B. 2. 1. SHOP DRAWINGS AND SUBMITTAL: 12. A. General Requirements 14. Convenience receptacles will be 20 amp, commercial grade Light switches will be 20 amp, commercial grade, B. ELECTRICAL DEVICES A. decora style. Finish per owner or architect. Provide decora style, finish per owner or architect. Dimming switches will be a minimum of 600W or as noted. C. 15. Support all electrical equipment independent of accessible ceilings as required by NEC. SUPPORT A. All mounting heights will conform to ADA guidelines. Typical receptacle D. heights will be +18"AFF and switch heights will be +46"AFF unless noted otherwise. 16. At fire rated wall, space electrical boxes at opposite sides of the wall no less than 24" horizontal distance. ELECTRICAL BOXES A. When phone, TV & power receptacles are shown on plan next to each other. Locate respective receptacles next to each other on site with no more B. than 1" separating cover plates. Provide GFI type receptacles at kitchens, bathrooms, garages, exterior etc. as required by code. E. equipment, etc. furnish by mechanical - refer to both electrical and and mechanical drawing for scope and work and additinal infor- Complete connection of HVAC/Plumbing motor(s), water heater(s), Fire alarm system will be by electrical contractor. 3. 4. 6. 5. Provide grounding and bonding Facilities. Complete all electrical demolition as required. mation. and contractor shall have written approvals from building owner prior Core drilling and patching of existing building structure required for Operating, Maintenance and identification instructions manuals, if electrical work. Core drilling shall follow Building Standard procedures Applicable codes: National Electric Code (2017) PERMITS AND FEES: Obtain and pay for all necessary permits, inspec- tions, examinations and fees or charges necessary for execution and and to the requirements of Federal, State or other City agencies Town of Vail Electrical Code, pertinent NFPA publications Conform to the prevailing edition and amendments thereto of the to start of any work. Test of entire system and work. REGULATIONS AND CODES: having jurisdiction. completion of electrical work. 11. A. 7. 9. 8. 10. any. decora style. Finish per owner or architect. All dwelling unit receptacles to be tamper-resistant per NEC 406.11. MC cable permitted per local codes. Run hard pipe from panel to local junction box, and run MC cable from junction box to device. CONDUCTOR SIZES AND TYPES: For sizes #1/0 AWG and larger, use coppper THW or aluminum XHHW. For sizes #1 AWG and smaller, use only copper wire with 600V insulation, types TW, THHN, or THW - stranded in sizes #8 and larger, solid in sizes #10 and smaller. Control wiring shall be #14, stranded. Use type THHN for wires entering or passing through fluorescent lighting fixtures. All motors shall be wired with copper conductors only. 17. METERING A. EC shall coordinate whether or not meters require lever bypass with local utility and provide all meters with a lever bypass when required. Copyright © 2017 by Zehren & Associates Inc. 10/02/17