HomeMy WebLinkAboutB17-0396_NW-1_1506985217.pdfDESCRIPTION
NO.
SHEET INDEX
SYSTEM INFORMATION
NANAWALL PRODUCT DRAWINGS
SHEET NUMBER
DETAIL NUMBER
FIELD APPLIED SEALANT BY GLAZING SUB CONTRACTOR
DIMENSIONAL REFERENCE / ELEVATION
DENOTES BACKER ROD OR CAULK ROPE
NOT NECESSARILY ONE PIECE
DENOTES BLOCKING OR SHIM, NOT CONTINUOUS,
S
WORK POINT
FASTENER LOCATION
SYMBOLS
DETAIL INDICATOR
ELEVATION / PLAN SECTION TITLE
DETAIL / SECTION TITLE
SYSTEM TYPE
A WATER RATING IS RELATIVE AND EVEN THE HIGHEST RATED PRODUCT MIGHT LEAK UNDER
SEVERE, UNUSUAL, OR UNFORESEEN CLIMATIC CONDITIONS. PERFORMANCE OF NANAWALL
PRODUCTS DEPENDS ON PROPER INSTALLATION AND USE OF THE PRODUCTS, AS WELL AS
SELECTION OF THE PROPER SYSTEM FOR THE SITE CONDITIONS.
NANAWALL WILL NOT BE RESPONSIBLE FOR ANY COSTS ASSOCIATED WITH FIELD TESTING OF
ANY NANAWALL PRODUCT. ANY TESTING OF NEWLY INSTALLED PRODUCT MUST BE
PERFORMED IN COMPLIANCE WITH AAMA 502, INCLUDING WATER PENETRATION TESTING AT
2/3 TESTED LABORATORY PERFORMANCE. NANAWALL MUST RECEIVE ADEQUATE NOTICE OF
TESTING AND OPPORTUNITY TO ATTEND. NANAWALL WILL REMEDIATE ANY PRODUCT FAILURE
IT CONFIRMS. FAILURE OF TESTED PRODUCT DOES NOT EQUATE TO A FAILURE OF OTHER
PRODUCTS. TESTING OF PRODUCT INSTALLED LONGER THAN SIX (6) MONTHS MUST BE
TESTED IN COMPLIANCE WITH AAMA 511 AND BE DIRECTED AT RECREATION OF AN EXISTING
IN-SERVICE CONDITION.
BUYER TO CONFIRM FROM APPLICABLE NANAWALL DESIGN WINDLOAD CHARTS THAT
POSITIVE AND NEGATIVE DESIGN PRESSURES FOR THE PROJECT ARE MET FOR THE PANEL
6,=(6 2) 7+( 81,76 ,1 7+( 25'(5 7+(6( :,1'/2$' &+$576 +$9( %((1 '(5,9(' )520
COMPARATIVE ANALYSIS OF STRUCTURAL LOAD TEST RESULTS PER ASTM E330 OF A TEST
63(&,0(1 7+( 86( 2) 7+(6( :,1'/2$' &+$576 :,// %( 68%-(&7 72 7+( /,0,7$7,216
STATED ON THEM.
8. PROTECTION. ALL GLASS AND FINISHED MATERIAL MUST BE PROTECTED DURING THE
CONSTRUCTION PHASE FROM ALL TYPES OF CONSTRUCTION OPERATIONS SUCH AS CEMENT
SPLATTER, TAR, PAINT, WELDING OPERATIONS, FIREPROOFING OR ANY OTHER PROCESS
THAT MAY BE HARMFUL TO THE APPEARANCE OR PERFORMANCE OF THE PROJECT
MATERIALS.
9. UNLOADING PRODUCT. FOR STANDARD DELIVERY, UNLOADING OF PRODUCT FROM THE
DELIVERY TRUCK IS THE RESPONSIBILITY OF BUYER. DUE TO THE WEIGHT OF THE PRODUCT,
APPROPRIATE MANPOWER AND/OR EQUIPMENT WILL BE NEEDED. FIRST THRESHOLD
DELIVERY IS AVAILABLE FOR MOST PRODUCTS FOR AN EXTRA CHARGE.
10. TEMPERED GLASS. ON RARE OCCASIONS, TEMPERED GLASS PANES SPONTANEOUSLY
BREAK FOR NO APPARENT REASON. ONE POSSIBLE CAUSE IS NICKEL SULFIDE INCLUSIONS IN
TEMPERED GLASS THAT CANNOT BE COMPLETELY PREVENTED. IN NANAWALL ALL GLASS
SYSTEMS WITH NO VERTICAL STILES, ANOTHER POSSIBLE REASON FOR SPONTANEOUS
GLASS BREAKAGE IS STRESS CONCENTRATIONS AROUND NICKS OR CHIPS NEAR THE EDGE
OF THE GLASS PANES. PANELS SHOULD BE MOVED WITH CARE TO PREVENT GLASS-TO-GLASS
CONTACT BETWEEN PANELS. INSTALL THE GLASS PROTECTOR GASKETS PROVIDED BY
NANAWALL TO MINIMIZE THE CHANCE OF BREAKAGE SHOULD GLASS CONTACT OCCUR. ANY
DAMAGED GLASS PANES ARE NOT THE RESPONSIBILITY OF NANAWALL AND SHOULD BE
REPLACED AS SOON AS POSSIBLE.
11. NANAWALL DRAWINGS. THESE COPYRIGHTED DRAWINGS HAVE BEEN PREPARED IN
ACCORDANCE WITH NANAWALL'S ORDER AGREEMENT AND ANY ACCEPTED CHANGE ORDER.
FINAL APPROVAL BY THE BUYER CONSTITUTES ACCEPTANCE OF ALL DEVIATIONS TO THE
CONTRACT DOCUMENTS MADE BY NANAWALL IN THESE DRAWINGS.
THESE DRAWINGS REPRESENT NANAWALL'S INTERPRETATION OF THE APPLICATION OF
PRODUCTS TO THIS PROJECT IN FUNCTIONAL COMPLIANCE WITH THE ORDER AGREEMENT. IT
IS IMPORTANT THAT THIS INTERPRETATION BE REVIEWED DIMENSIONALLY AND
FUNCTIONALLY WITH RESPECT TO THE ARCHITECT'S ACTUAL INTENT, INTERFACING
CONDITIONS, MATERIALS AND JOB SITE CONDITIONS. NANAWALL ASSUMES NO
RESPONSIBILITY FOR ERRORS RESULTING FROM THE USE OF THESE DRAWINGS BY OTHER
TRADES.
ANY CHANGES IN DIMENSIONS, DESIGN OR LAYOUT MADE AFTER PRODUCT DRAWINGS ARE
PREPARED MAY RESULT IN THE NEED FOR REVISED DRAWINGS. REVISED DRAWINGS WILL
RESULT IN AN EXTRA CHARGE TO BE DETERMINED BY NANAWALL AND PAID BY CUSTOMER
BEFORE THE DRAWINGS ARE REVISED.
ALL DRAWINGS ARE ACCURATE IN METRIC DIMENSIONS. ENGLISH DIMENSIONS SHOWN ARE
ROUNDED TO THE NEAREST 1/16". PRODUCT DRAWINGS SHOULD NOT BE SCALED. SCALE
NOTED ON DRAWINGS ARE BASED ON A 24" X 36" PAPER FORMAT.
12. UNAUTHORIZED USE OF DRAWINGS. IN NO EVENT SHALL BUYER DISCLOSE, COPY OR USE
ANY OF THE PRODUCT DRAWINGS PREPARED BY NANAWALL FOR ANY PURPOSE OTHER THAN
IN RELATION TO THE PURCHASE OR INSTALLATION OF NANAWALL PRODUCT. ANY OTHER USE
OF THESE PRODUCT DRAWINGS IS EXPRESSLY PROHIBITED WITHOUT THE PRIOR WRITTEN
CONSENT OF NANAWALL. NANAWALL IS ENTITLED TO LIQUIDATED DAMAGES IN THE AMOUNT
OF 20% OF THE PURCHASE PRICE OF THE CONTRACT FOR SALE FOR EACH VIOLATION.
GENERAL NOTES
1. MATERIAL SUPPLIER. NANA WALL SYSTEMS INC. ³1$1$:$//´ IS A MATERIAL SUPPLIER OF
SLIDING & FOLDING PANEL SYSTEMS. NANAWALL DOES NOT PROVIDE INSTALLATION
SERVICES OR DESIGN/ENGINEER SURROUNDING CONDITIONS AROUND THE OPENINGS TO
WHICH NANAWALL'S SYSTEMS ARE TO BE INSTALLED. ANY SURROUNDING CONDITIONS
SHOWN IN THESE DRAWINGS ARE MEANT FOR ILLUSTRATIVE PURPOSES ONLY AND WHAT IS
SHOWN MAY NOT BE SUITABLE FOR ANY PARTICULAR PROJECT.
2. CUSTOMER RESPONSIBILITY. IT IS THE SOLE RESPONSIBILITY OF THE ARCHITECT, BUILDING
OWNER, CONTRACTOR AND/OR CONSUMER (COLLECTIVELY "CUSTOMER") TO ENSURE
COMPLIANCE WITH PROJECT PLANS AND SPECIFICATIONS AS WELL AS ALL APPLICABLE
CODES AND REGULATIONS, INCLUDING FEDERAL, STATE AND LOCAL REQUIREMENTS. IT IS
THE SOLE RESPONSIBILITY OF CUSTOMER TO DETAIL AND INSTALL NANAWALL PRODUCT IN
AN OPENING WITH PROPER STRUCTURAL INTEGRITY AND FLASHING DETAILS NECESSARY TO
ENSURE A WATER RESISTANT INSTALLATION.
3. ASSEMBLY & INSTALLATION. PRODUCTS ARE SUPPLIED ³.12&.(' '2:1´ FOR ASSEMBLY
AND INSTALLATION BY OTHERS. PROPER ASSEMBLY, INSTALLATION, OPERATION AND
MAINTENANCE IS ESSENTIAL FOR PROPER PERFORMANCE. WRITTEN INSTRUCTIONS ARE
PROVIDED TO ALL CUSTOMERS TO FOLLOW. IT IS HIGHLY RECOMMENDED THAT AN
EXPERIENCED INSTALLER OF NANAWALL'S PRODUCTS BE USED FOR RELEVANT ASPECTS OF
ASSEMBLY AND INSTALLATION.
THE ROUGH OPENINGS MUST BE PLUMB, LEVEL, SQUARE AND WITHIN SPECIFIED BUILDING
TOLERANCES. HEAD TRACK AND SILL (BOTTOM TRACK) COMPONENTS MAY BE SHIPPED IN
SEGMENTS THAT WILL NEED TO BE FIELD JOINED PER NANAWALL INSTRUCTIONS. MAKE SURE
THAT WHEN INSTALLED, THE JOINTS BETWEEN THE HEAD TRACK AND SILL COMPONENTS ARE
SMOOTH AND TIGHT.
SPECIFIC AND DETAILED INSTALLATION METHODS AND MATERIALS MUST BE PROVIDED BY
OTHERS, INCLUDING BUT NOT LIMITED TO FASTENER SELECTION AND METHOD OF
ATTACHMENT, CAULKING/SEALANT AT DISSIMILAR MATERIALS, FLASHING, AND
INCORPORATION INTO THE BUILDING ENVELOPE FOR APPROPRIATE WATERPROOFING.
4. STRUCTURAL SUPPORT. THE STRUCTURAL INTEGRITY OF THE FLOOR, HEADER AND/OR
OVERHEAD SUPPORT FOR THE OPENING, AND ANY STACKING AREAS, IS CRITICAL FOR
PROPER PERFORMANCE AND OPERATION. THE CALCULATIONS, MATERIALS AND
INSTALLATION DETAILS MUST BE PROVIDED BY OTHERS.
THE VERTICAL DEFLECTION AT THESE AREAS UNDER FULL LIVE AND DEAD LOADS SHOULD BE
THE LESSER OF L/720 OF THE SPAN OR 1/4". THE HEADER, SURROUNDING WALLS AND FLOOR
MUST ALSO BE ABLE TO SUPPORT ANY LATERAL LOADS. PERIMETER FASTENERS AND
SUBSTRATE MUST BE CAPABLE OF WITHSTANDING REACTION FORCES IMPOSED BY WIND
AND/OR DEAD LOAD. THERE MAY BE ADDITIONAL STRUCTURAL REQUIREMENTS NOT
MENTIONED HERE.
SPECIFIC AND DETAILED STRUCTURAL SUPPORT REQUIREMENTS MUST BE PROVIDED BY
OTHERS, INCLUDING, BUT NOT LIMITED TO, SIZES, LOCATIONS OR FREQUENCY OF PERIMETER
FASTENERS; ANCHORING TO THE SUBSTRATE; STRUCTURAL CALCULATIONS; AND
ENGINEERING OF DETAILED ALUMINUM, WOOD AND GLASS SYSTEMS.
5. UNIT SIZES & ROUGH OPENING. CHECK SIZES ON DRAWINGS CAREFULLY AND NOTE THE
MEASUREMENT POINTS FOR UNIT WIDTH AND UNIT HEIGHT. APPROPRIATE SHIM SPACE MUST
BE ADDED ON ALL FOUR (4) SIDES OF THE OPENING TO OBTAIN THE ROUGH OPENINGS. NOTE
THE POSITION OF THE SILL RELATIVE TO THE FINISH FLOOR OR FINISH COUNTERTOP. ANY
CHANGES ON WIDTH OR HEIGHT WILL REQUIRE REVISED DRAWINGS FOR FINAL APPROVAL.
6. ORIENTATION OF DRAWINGS. ELEVATIONS ARE VIEWED FROM THE INTERIOR FOR ALL
NANAWALL SYSTEMS, WITH THE EXCEPTION OF THE HSW75, FSW75 AND CSW75 WHICH ARE
VIEWED FROM THE EXTERIOR. CAREFULLY CHECK THE CONFIGURATIONS SHOWN FOR
ACCURACY, INCLUDING NUMBER OF PANELS ON EACH SIDE OF THE OPENING AND DIRECTION
OF SWING. FOR FOLDING SYSTEMS, THERE MUST BE AN ODD NUMBER OF PANELS IN EITHER
DIRECTION TO HAVE A SWING PANEL THAT CAN BE OPERATED LIKE A MAN DOOR.
7. PRODUCT PERFORMANCE & TESTING. NANAWALL HAS NOT TESTED EACH PRODUCT FOR
AIR LEAKAGE, WATER RESISTANCE AND STRUCTURAL LOADING CAPABILITIES. TESTING
RESULTS AVAILABLE FROM NANAWALL ARE ONLY APPLICABLE FOR THE SPECIFIC UNITS AND
CONFIGURATIONS TESTED IN LABORATORY CONDITIONS. TEST RESULTS WILL DEPEND ON
VARIABLES SUCH AS THE SYSTEM, SILL, LOCKING MECHANISM, SIZE AND CONFIGURATION.
DEPENDING ON SITE CONDITIONS, SILLS MAY NEED TO BE SITE MODIFIED BY OTHERS WITH
WEEP HOLES FOR PROPER DRAINAGE. THE HIGH PERFORMANCE (RAISED) SILL IS CAPABLE OF
A HIGHER WATER RESISTANCE CAPABILITY. NON-STANDARD UNITS, E.G. SEGMENTED OR
CORNERLESS UNITS, WILL HAVE A LOWER PERFORMANCE RATING THAN A STANDARD UNIT.
SEE NANAWALL LITERATURE AND WEBSITE FOR FURTHER INFORMATION.
GENERAL NOTES - continued
QUOTE NUMBER: 357609
ORDER NUMBER: 0
PROJECT NAME: Vail Resorts
CUSTOMER: Burke Harrington Construction
SYSTEM ON THIS DRAWING: SL70 FOLDING SYSTEMS (ALU)
CONFIGURATION: OUTWARD 4 LEFT
TYPE OF GLASS: DOUBLE GLAZED LOW E INSULATED TEMPERED 70 , SPACER BAR
WITH SILVER GRAY FINISH
HARDWARE MAIN DOOR: TWO POINT LOCKING WITH L SHAPED HANDLE ON THE INSIDE
AND STANDARD HANDLE ON THE OUTSIDE. THUMBTURN ON
THE INSIDE AND KEY OPERATION ON THE OUTSIDE.
HARDWARE ON FOLDING: STANDARD HANDLE STAINLESS STEEL WITH BRUSHED
SATIN FINISH
HINGE FINISH: POWDER COATED MATCH
SILL TYPE: THERMALLY BROKEN LOW PROFILE SADDLE
SILL FINISH: CLEAR ANODIZED
EXTRA INFORMATION
0.38
CLEAR ANODIZED
WOOD DESCRIPTION:
POWDER COATED ALUMINUM
ANODIZED ALUMINUM
PROFILE FINISH SCHEDULE
1 COVER SHEET
3
4 DETAIL SHEET(S)
ELEVATIONS & PLAN SECTIONS
2 INSTALLATION DETAIL SHEET(S)
ROUGH OPENING
OVERALL FRAME DIMENSION
SIMULATED DIVIDED LITE
=
=
=
=
=
RO
SDL
OFD
DAYLIGHT OPENING
NOT BY NANAWALL
ABOVE FINISH FLOOR
OPENING DIMENSION
ELEVATION
EL
=
=
=
=
NTS
OD
NBN
FF
FS
NOT TO SCALE
FRAME SIZE
FINISH FLOOR
=
=
=
=
=
= L
C
DO
DLO
DIM.
AFF
CENTER LINE
DIMENSION
DOOR OPENING
ABBREVIATIONS
= UNIT WIDTH
UW
TO BE DETERMINED
TBD
= MILIMETERS
MM
EQUAL
EQ =
A REASONABLE DEGREE OF COLOR/FINISH VARIATION CAN
BE EXPECTED BETWEEN ANY SAMPLE PROVIDED AND
352'8&7,21 /,1( $33/,&$7,21 ¬)25 :22' 352'8&76
THE COLOR AND TEXTURE CAN VARY, EVEN WITHIN THE
SAME PIECE OF WOOD.
NOTE:
NFRC:
IF YOU WOULD LIKE TO RECEIVE ELEVATION, FLOOR PLAN AND CROSS SECTION
DETAILS IN AUTOCAD, PLEASE CONTACT NANAWALL
#22418'&
#22418#.
241,'%6 +0(14/#6+10
#22418'&
&9)
24+06'& 0#/'
$;
'
215+6+10
(+456 57$/+66#.
5*''6
14&'4
5%#.'
&4#90 $;
3716'
1(
065
0&)
\initial_1_1\
10/02/17