Loading...
HomeMy WebLinkAboutB17-0396_NW-1_1506985217.pdfDESCRIPTION NO. SHEET INDEX SYSTEM INFORMATION NANAWALL PRODUCT DRAWINGS SHEET NUMBER DETAIL NUMBER FIELD APPLIED SEALANT BY GLAZING SUB CONTRACTOR DIMENSIONAL REFERENCE / ELEVATION DENOTES BACKER ROD OR CAULK ROPE NOT NECESSARILY ONE PIECE DENOTES BLOCKING OR SHIM, NOT CONTINUOUS, S WORK POINT FASTENER LOCATION SYMBOLS DETAIL INDICATOR ELEVATION / PLAN SECTION TITLE DETAIL / SECTION TITLE SYSTEM TYPE A WATER RATING IS RELATIVE AND EVEN THE HIGHEST RATED PRODUCT MIGHT LEAK UNDER SEVERE, UNUSUAL, OR UNFORESEEN CLIMATIC CONDITIONS. PERFORMANCE OF NANAWALL PRODUCTS DEPENDS ON PROPER INSTALLATION AND USE OF THE PRODUCTS, AS WELL AS SELECTION OF THE PROPER SYSTEM FOR THE SITE CONDITIONS. NANAWALL WILL NOT BE RESPONSIBLE FOR ANY COSTS ASSOCIATED WITH FIELD TESTING OF ANY NANAWALL PRODUCT. ANY TESTING OF NEWLY INSTALLED PRODUCT MUST BE PERFORMED IN COMPLIANCE WITH AAMA 502, INCLUDING WATER PENETRATION TESTING AT 2/3 TESTED LABORATORY PERFORMANCE. NANAWALL MUST RECEIVE ADEQUATE NOTICE OF TESTING AND OPPORTUNITY TO ATTEND. NANAWALL WILL REMEDIATE ANY PRODUCT FAILURE IT CONFIRMS. FAILURE OF TESTED PRODUCT DOES NOT EQUATE TO A FAILURE OF OTHER PRODUCTS. TESTING OF PRODUCT INSTALLED LONGER THAN SIX (6) MONTHS MUST BE TESTED IN COMPLIANCE WITH AAMA 511 AND BE DIRECTED AT RECREATION OF AN EXISTING IN-SERVICE CONDITION. BUYER TO CONFIRM FROM APPLICABLE NANAWALL DESIGN WINDLOAD CHARTS THAT POSITIVE AND NEGATIVE DESIGN PRESSURES FOR THE PROJECT ARE MET FOR THE PANEL 6,=(6 2) 7+( 81,76 ,1 7+( 25'(5 7+(6( :,1'/2$' &+$576 +$9( %((1 '(5,9(' )520 COMPARATIVE ANALYSIS OF STRUCTURAL LOAD TEST RESULTS PER ASTM E330 OF A TEST 63(&,0(1 7+( 86( 2) 7+(6( :,1'/2$' &+$576 :,// %( 68%-(&7 72 7+( /,0,7$7,216 STATED ON THEM. 8. PROTECTION. ALL GLASS AND FINISHED MATERIAL MUST BE PROTECTED DURING THE CONSTRUCTION PHASE FROM ALL TYPES OF CONSTRUCTION OPERATIONS SUCH AS CEMENT SPLATTER, TAR, PAINT, WELDING OPERATIONS, FIREPROOFING OR ANY OTHER PROCESS THAT MAY BE HARMFUL TO THE APPEARANCE OR PERFORMANCE OF THE PROJECT MATERIALS. 9. UNLOADING PRODUCT. FOR STANDARD DELIVERY, UNLOADING OF PRODUCT FROM THE DELIVERY TRUCK IS THE RESPONSIBILITY OF BUYER. DUE TO THE WEIGHT OF THE PRODUCT, APPROPRIATE MANPOWER AND/OR EQUIPMENT WILL BE NEEDED. FIRST THRESHOLD DELIVERY IS AVAILABLE FOR MOST PRODUCTS FOR AN EXTRA CHARGE. 10. TEMPERED GLASS. ON RARE OCCASIONS, TEMPERED GLASS PANES SPONTANEOUSLY BREAK FOR NO APPARENT REASON. ONE POSSIBLE CAUSE IS NICKEL SULFIDE INCLUSIONS IN TEMPERED GLASS THAT CANNOT BE COMPLETELY PREVENTED. IN NANAWALL ALL GLASS SYSTEMS WITH NO VERTICAL STILES, ANOTHER POSSIBLE REASON FOR SPONTANEOUS GLASS BREAKAGE IS STRESS CONCENTRATIONS AROUND NICKS OR CHIPS NEAR THE EDGE OF THE GLASS PANES. PANELS SHOULD BE MOVED WITH CARE TO PREVENT GLASS-TO-GLASS CONTACT BETWEEN PANELS. INSTALL THE GLASS PROTECTOR GASKETS PROVIDED BY NANAWALL TO MINIMIZE THE CHANCE OF BREAKAGE SHOULD GLASS CONTACT OCCUR. ANY DAMAGED GLASS PANES ARE NOT THE RESPONSIBILITY OF NANAWALL AND SHOULD BE REPLACED AS SOON AS POSSIBLE. 11. NANAWALL DRAWINGS. THESE COPYRIGHTED DRAWINGS HAVE BEEN PREPARED IN ACCORDANCE WITH NANAWALL'S ORDER AGREEMENT AND ANY ACCEPTED CHANGE ORDER. FINAL APPROVAL BY THE BUYER CONSTITUTES ACCEPTANCE OF ALL DEVIATIONS TO THE CONTRACT DOCUMENTS MADE BY NANAWALL IN THESE DRAWINGS. THESE DRAWINGS REPRESENT NANAWALL'S INTERPRETATION OF THE APPLICATION OF PRODUCTS TO THIS PROJECT IN FUNCTIONAL COMPLIANCE WITH THE ORDER AGREEMENT. IT IS IMPORTANT THAT THIS INTERPRETATION BE REVIEWED DIMENSIONALLY AND FUNCTIONALLY WITH RESPECT TO THE ARCHITECT'S ACTUAL INTENT, INTERFACING CONDITIONS, MATERIALS AND JOB SITE CONDITIONS. NANAWALL ASSUMES NO RESPONSIBILITY FOR ERRORS RESULTING FROM THE USE OF THESE DRAWINGS BY OTHER TRADES. ANY CHANGES IN DIMENSIONS, DESIGN OR LAYOUT MADE AFTER PRODUCT DRAWINGS ARE PREPARED MAY RESULT IN THE NEED FOR REVISED DRAWINGS. REVISED DRAWINGS WILL RESULT IN AN EXTRA CHARGE TO BE DETERMINED BY NANAWALL AND PAID BY CUSTOMER BEFORE THE DRAWINGS ARE REVISED. ALL DRAWINGS ARE ACCURATE IN METRIC DIMENSIONS. ENGLISH DIMENSIONS SHOWN ARE ROUNDED TO THE NEAREST 1/16". PRODUCT DRAWINGS SHOULD NOT BE SCALED. SCALE NOTED ON DRAWINGS ARE BASED ON A 24" X 36" PAPER FORMAT. 12. UNAUTHORIZED USE OF DRAWINGS. IN NO EVENT SHALL BUYER DISCLOSE, COPY OR USE ANY OF THE PRODUCT DRAWINGS PREPARED BY NANAWALL FOR ANY PURPOSE OTHER THAN IN RELATION TO THE PURCHASE OR INSTALLATION OF NANAWALL PRODUCT. ANY OTHER USE OF THESE PRODUCT DRAWINGS IS EXPRESSLY PROHIBITED WITHOUT THE PRIOR WRITTEN CONSENT OF NANAWALL. NANAWALL IS ENTITLED TO LIQUIDATED DAMAGES IN THE AMOUNT OF 20% OF THE PURCHASE PRICE OF THE CONTRACT FOR SALE FOR EACH VIOLATION. GENERAL NOTES 1. MATERIAL SUPPLIER. NANA WALL SYSTEMS INC. ³1$1$:$//´ IS A MATERIAL SUPPLIER OF SLIDING & FOLDING PANEL SYSTEMS. NANAWALL DOES NOT PROVIDE INSTALLATION SERVICES OR DESIGN/ENGINEER SURROUNDING CONDITIONS AROUND THE OPENINGS TO WHICH NANAWALL'S SYSTEMS ARE TO BE INSTALLED. ANY SURROUNDING CONDITIONS SHOWN IN THESE DRAWINGS ARE MEANT FOR ILLUSTRATIVE PURPOSES ONLY AND WHAT IS SHOWN MAY NOT BE SUITABLE FOR ANY PARTICULAR PROJECT. 2. CUSTOMER RESPONSIBILITY. IT IS THE SOLE RESPONSIBILITY OF THE ARCHITECT, BUILDING OWNER, CONTRACTOR AND/OR CONSUMER (COLLECTIVELY "CUSTOMER") TO ENSURE COMPLIANCE WITH PROJECT PLANS AND SPECIFICATIONS AS WELL AS ALL APPLICABLE CODES AND REGULATIONS, INCLUDING FEDERAL, STATE AND LOCAL REQUIREMENTS. IT IS THE SOLE RESPONSIBILITY OF CUSTOMER TO DETAIL AND INSTALL NANAWALL PRODUCT IN AN OPENING WITH PROPER STRUCTURAL INTEGRITY AND FLASHING DETAILS NECESSARY TO ENSURE A WATER RESISTANT INSTALLATION. 3. ASSEMBLY & INSTALLATION. PRODUCTS ARE SUPPLIED ³.12&.(' '2:1´ FOR ASSEMBLY AND INSTALLATION BY OTHERS. PROPER ASSEMBLY, INSTALLATION, OPERATION AND MAINTENANCE IS ESSENTIAL FOR PROPER PERFORMANCE. WRITTEN INSTRUCTIONS ARE PROVIDED TO ALL CUSTOMERS TO FOLLOW. IT IS HIGHLY RECOMMENDED THAT AN EXPERIENCED INSTALLER OF NANAWALL'S PRODUCTS BE USED FOR RELEVANT ASPECTS OF ASSEMBLY AND INSTALLATION. THE ROUGH OPENINGS MUST BE PLUMB, LEVEL, SQUARE AND WITHIN SPECIFIED BUILDING TOLERANCES. HEAD TRACK AND SILL (BOTTOM TRACK) COMPONENTS MAY BE SHIPPED IN SEGMENTS THAT WILL NEED TO BE FIELD JOINED PER NANAWALL INSTRUCTIONS. MAKE SURE THAT WHEN INSTALLED, THE JOINTS BETWEEN THE HEAD TRACK AND SILL COMPONENTS ARE SMOOTH AND TIGHT. SPECIFIC AND DETAILED INSTALLATION METHODS AND MATERIALS MUST BE PROVIDED BY OTHERS, INCLUDING BUT NOT LIMITED TO FASTENER SELECTION AND METHOD OF ATTACHMENT, CAULKING/SEALANT AT DISSIMILAR MATERIALS, FLASHING, AND INCORPORATION INTO THE BUILDING ENVELOPE FOR APPROPRIATE WATERPROOFING. 4. STRUCTURAL SUPPORT. THE STRUCTURAL INTEGRITY OF THE FLOOR, HEADER AND/OR OVERHEAD SUPPORT FOR THE OPENING, AND ANY STACKING AREAS, IS CRITICAL FOR PROPER PERFORMANCE AND OPERATION. THE CALCULATIONS, MATERIALS AND INSTALLATION DETAILS MUST BE PROVIDED BY OTHERS. THE VERTICAL DEFLECTION AT THESE AREAS UNDER FULL LIVE AND DEAD LOADS SHOULD BE THE LESSER OF L/720 OF THE SPAN OR 1/4". THE HEADER, SURROUNDING WALLS AND FLOOR MUST ALSO BE ABLE TO SUPPORT ANY LATERAL LOADS. PERIMETER FASTENERS AND SUBSTRATE MUST BE CAPABLE OF WITHSTANDING REACTION FORCES IMPOSED BY WIND AND/OR DEAD LOAD. THERE MAY BE ADDITIONAL STRUCTURAL REQUIREMENTS NOT MENTIONED HERE. SPECIFIC AND DETAILED STRUCTURAL SUPPORT REQUIREMENTS MUST BE PROVIDED BY OTHERS, INCLUDING, BUT NOT LIMITED TO, SIZES, LOCATIONS OR FREQUENCY OF PERIMETER FASTENERS; ANCHORING TO THE SUBSTRATE; STRUCTURAL CALCULATIONS; AND ENGINEERING OF DETAILED ALUMINUM, WOOD AND GLASS SYSTEMS. 5. UNIT SIZES & ROUGH OPENING. CHECK SIZES ON DRAWINGS CAREFULLY AND NOTE THE MEASUREMENT POINTS FOR UNIT WIDTH AND UNIT HEIGHT. APPROPRIATE SHIM SPACE MUST BE ADDED ON ALL FOUR (4) SIDES OF THE OPENING TO OBTAIN THE ROUGH OPENINGS. NOTE THE POSITION OF THE SILL RELATIVE TO THE FINISH FLOOR OR FINISH COUNTERTOP. ANY CHANGES ON WIDTH OR HEIGHT WILL REQUIRE REVISED DRAWINGS FOR FINAL APPROVAL. 6. ORIENTATION OF DRAWINGS. ELEVATIONS ARE VIEWED FROM THE INTERIOR FOR ALL NANAWALL SYSTEMS, WITH THE EXCEPTION OF THE HSW75, FSW75 AND CSW75 WHICH ARE VIEWED FROM THE EXTERIOR. CAREFULLY CHECK THE CONFIGURATIONS SHOWN FOR ACCURACY, INCLUDING NUMBER OF PANELS ON EACH SIDE OF THE OPENING AND DIRECTION OF SWING. FOR FOLDING SYSTEMS, THERE MUST BE AN ODD NUMBER OF PANELS IN EITHER DIRECTION TO HAVE A SWING PANEL THAT CAN BE OPERATED LIKE A MAN DOOR. 7. PRODUCT PERFORMANCE & TESTING. NANAWALL HAS NOT TESTED EACH PRODUCT FOR AIR LEAKAGE, WATER RESISTANCE AND STRUCTURAL LOADING CAPABILITIES. TESTING RESULTS AVAILABLE FROM NANAWALL ARE ONLY APPLICABLE FOR THE SPECIFIC UNITS AND CONFIGURATIONS TESTED IN LABORATORY CONDITIONS. TEST RESULTS WILL DEPEND ON VARIABLES SUCH AS THE SYSTEM, SILL, LOCKING MECHANISM, SIZE AND CONFIGURATION. DEPENDING ON SITE CONDITIONS, SILLS MAY NEED TO BE SITE MODIFIED BY OTHERS WITH WEEP HOLES FOR PROPER DRAINAGE. THE HIGH PERFORMANCE (RAISED) SILL IS CAPABLE OF A HIGHER WATER RESISTANCE CAPABILITY. NON-STANDARD UNITS, E.G. SEGMENTED OR CORNERLESS UNITS, WILL HAVE A LOWER PERFORMANCE RATING THAN A STANDARD UNIT. SEE NANAWALL LITERATURE AND WEBSITE FOR FURTHER INFORMATION. GENERAL NOTES - continued QUOTE NUMBER: 357609 ORDER NUMBER: 0 PROJECT NAME: Vail Resorts CUSTOMER: Burke Harrington Construction SYSTEM ON THIS DRAWING: SL70 FOLDING SYSTEMS (ALU) CONFIGURATION: OUTWARD 4 LEFT TYPE OF GLASS: DOUBLE GLAZED LOW E INSULATED TEMPERED 70 , SPACER BAR WITH SILVER GRAY FINISH HARDWARE MAIN DOOR: TWO POINT LOCKING WITH L SHAPED HANDLE ON THE INSIDE AND STANDARD HANDLE ON THE OUTSIDE. THUMBTURN ON THE INSIDE AND KEY OPERATION ON THE OUTSIDE. HARDWARE ON FOLDING: STANDARD HANDLE STAINLESS STEEL WITH BRUSHED SATIN FINISH HINGE FINISH: POWDER COATED MATCH SILL TYPE: THERMALLY BROKEN LOW PROFILE SADDLE SILL FINISH: CLEAR ANODIZED EXTRA INFORMATION 0.38 CLEAR ANODIZED WOOD DESCRIPTION: POWDER COATED ALUMINUM ANODIZED ALUMINUM PROFILE FINISH SCHEDULE 1 COVER SHEET 3 4 DETAIL SHEET(S) ELEVATIONS & PLAN SECTIONS 2 INSTALLATION DETAIL SHEET(S) ROUGH OPENING OVERALL FRAME DIMENSION SIMULATED DIVIDED LITE = = = = = RO SDL OFD DAYLIGHT OPENING NOT BY NANAWALL ABOVE FINISH FLOOR OPENING DIMENSION ELEVATION EL = = = = NTS OD NBN FF FS NOT TO SCALE FRAME SIZE FINISH FLOOR = = = = = = L C DO DLO DIM. AFF CENTER LINE DIMENSION DOOR OPENING ABBREVIATIONS = UNIT WIDTH UW TO BE DETERMINED TBD = MILIMETERS MM EQUAL EQ = A REASONABLE DEGREE OF COLOR/FINISH VARIATION CAN BE EXPECTED BETWEEN ANY SAMPLE PROVIDED AND 352'8&7,21 /,1( $33/,&$7,21 ¬)25 :22' 352'8&76 THE COLOR AND TEXTURE CAN VARY, EVEN WITHIN THE SAME PIECE OF WOOD. NOTE: NFRC: IF YOU WOULD LIKE TO RECEIVE ELEVATION, FLOOR PLAN AND CROSS SECTION DETAILS IN AUTOCAD, PLEASE CONTACT NANAWALL #22418'& #22418#. 241,'%6 +0(14/#6+10 #22418'& &9)  24+06'& 0#/' $; &#6' 215+6+10 (+456 57$/+66#.  5*''6 14&'4 5%#.' &4#90 $; 3716' 1(     065 0&) \initial_1_1\ 10/02/17