Loading...
HomeMy WebLinkAboutF17-0048_CS2987 Material Submittal_1507565040.pdf7026 South Tucson Way Centennial, CO 80112 (303) 792-0022 Fax (303) 792-9049 Fire Protection Hydraulic and Equipment Submittal Pancanowski Residence 520 Lionshead Loop Unit 302 Vail, CO 81658 WSFP #CS2987 Prepared by: Joshua Adam Project Manager Western States Fire Protection Co. 7026 South Tucson Way Centennial. CO 80112 (720) 895-5216 Email: josh.adam@wsfp.us Vail Fire & Emergency Services 10/09/17 Hydraulic Summary Report Description: Light Hazard Job Number: CS2987 Node Flow(gpm) Total Hose Streams 0.0 Safety Margin Required Available Node Hose Flow Static Residual Flow Total Demand (gpm) (psi) (psi) (gpm) (psi) (gpm) (psi) (psi) @ @ Name 5 128.9 104.0 25.0 200.0 0.0 150.0 69.3 Water Supply Design Engineer Job Number Total Water Required (Including Hose Allowance) 69.3 Maximum Pressure Unbalance In Loops 0.0 Additional Hose Supplies 0.0 Hose Allowance At Source Supplies 397.0gal Light Hazard 0.10gpm/ft² 225.00ft² 1500.00ft² (Actual 378.62ft²) 3 Occupancy Area of Application Coverage Per Sprinkler Number Of Sprinklers Calculated Density Job Suffix AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Volume capacity of Dry Pipes Volume capacity of Wet Pipes Maximum Velocity Under Ground 16.98 between nodes 2 and 1 Maximum Velocity Above Ground 4.4 K-Factor 22.0 at 25.0 Most Demanding Sprinkler Data System Vail, CO 81658 Job Site/Building 520 Lionshead Loop Unit 302 AHJ Pacanowski Residence Job State Certification/License Number Job Name: Josh Adam CS2987 Contractor Contractor Number 21 Name of Contractor: Western States Fire Protection Address 1 7026 S. Tucson Way Address 2 Centennial, CO 80112 Contact Name Contact Title Extension Phone 303-792-0022 FAX E-mail josh.adam@wsfp.us Web-Site Joshua Adam Address 3 Address 1 Address 2 Drawing Name CS2987 Vail Lionshead Center Unit 302 -1 System Flow Demand 69.3 Remote Area(s) Address 3 10/3/2017 © M.E.P.CAD, Inc. Page 1 AutoSPRINK® 12 v12.0.61.0 7:06:05PM Vail Fire & Emergency Services 10/09/17 Hydraulic Graph Report Description: Light Hazard Job Number: CS2987 0.0 @ 200.0 Residual: Pressure 150.0 Static: Pressure Water Supply at Node 5 Hydraulic Graph Water Supply at Node 5 104.0 @ 69.3 104.0 @ 69.3 Available Pressure at Time of Test 128.9 @ 69.3 System Demand System Demand (Including Hose Allowance at Source) © M.E.P.CAD, Inc. 10/3/2017 Page 2 AutoSPRINK® 12 v12.0.61.0 7:06:08PM Vail Fire & Emergency Services 10/09/17 Device (gpm) Actual Flow Minimum Flow (gpm) (K) K-Factor (psi) Pressure Summary Of Outflowing Devices Report Description: Light Hazard Job Number: CS2987 Sprinkler 101 25.0 22.0 4.4 32.2 Sprinkler 102 22.0 22.0 4.4 25.0 Sprinkler 103 22.3 22.0 4.4 25.7 Most Demanding Sprinkler Data © M.E.P.CAD, Inc. 10/3/2017 Page 3 AutoSPRINK® 12 v12.0.61.0 7:06:10PM Vail Fire & Emergency Services 10/09/17 Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: CS2987 Report Description: Light Hazard • • • • • Route 1 • • • • • Pf Pe Pv BL 1.055 22.0 8.07 0.099911 7'-2-5/8 0.7 102 9'-0 22.0 4.4 25.0 103 9'-0 25.7 7'-2-5/8 150 Sprinkler Pf Pe Pv BL 1.055 44.3 16.26 0.364966 18'-0¼ 9.5 103 9'-0 22.3 4.4 25.7 8'-0 3.9 1 0'-0 39.1 26'-0¼ 150 Sprinkler, 4E(2'-0) Pf Pe Pv BL 1.291 69.3 16.98 0.312014 9'-7 3.9 1 0'-0 25.0 39.1 3'-0 2 0'-0 43.0 12'-7 150 Flow (q) from Route 2 PO(3'-0) Pf Pe Pv CM 1.527 69.3 12.14 0.137749 225'-0 31.8 2 0'-0 43.0 6'-0 3 0'-0 74.9 231'-0 150 Tr(1'-0), 2E(2'-6) Pf Pe Pv CM 2.009 69.3 7.01 0.036214 200'-0 7.4 3 0'-0 74.9 3'-6 21.7 4 -50'-0 103.9 203'-6 150 E(3'-6) Pf Pe Pv CM 6.357 69.3 0.70 0.000200 200'-0 0.0 4 -50'-0 103.9 5 -50'-0 104.0 200'-0 120 Water Supply 69.3 0.0 Hose Allowance At Source 5 • • • • • Route 2 • • • • • Pf Pe Pv SP 1.055 25.0 9.16 0.126149 16'-2-1/8 3.0 101 9'-0 25.0 4.4 32.2 8'-0 3.9 1 0'-0 39.1 24'-2-1/8 150 Sprinkler, 2E(2'-0), 2T(2'-0) 1.51 4.87 ) ( 150 1.33 140 1.16 130 0.713 100 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter = Factor C Value Multiplier Value Of C Multiplying Factor © M.E.P.CAD, Inc. 10/3/2017 Page 4 AutoSPRINK® 12 v12.0.61.0 7:06:12PM Vail Fire & Emergency Services 10/09/17 Pipe Type Diameter Flow Velocity Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length HWC Hydraulic Analysis Job Number: CS2987 Report Description: Light Hazard Pipe Type Legend AO Arm-Over BL Branch Line CM Cross Main DN Drain DR Drop DY Dynamic FM Feed Main FR Feed Riser MS Miscellaneous OR Outrigger RN Riser Nipple SP Sprig ST Stand Pipe UG Underground Units Legend Diameter Inch Elevation Foot Flow gpm Discharge gpm Velocity fps Pressure psi Length Foot Friction Loss psi/Foot HWC Hazen-Williams Constant Pt Total pressure at a point in a pipe Pn Normal pressure at a point in a pipe Pf Pressure loss due to friction between points Pe Pressure due to elevation difference between indicated points Pv Velocity pressure at a point in a pipe Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Ee1 11¼° Elbow Ee2 22½° Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc. 10/3/2017 Page 5 AutoSPRINK® 12 v12.0.61.0 7:06:12PM Vail Fire & Emergency Services 10/09/17 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bulletin176Rev.A Bulletin 176 Rev. A ModelF1ResSprinklersengineeredforthelowestflows tomeettheminimumdesigndensityof.05gpm/ft2 Types: 1. F1 Res 49 Pendent 2. F1 Res 49 Recessed Pendent/F1 3. F1 Res 49 Recessed Pendent/FP 4. F1 Res 49 CCP Pendent 5. F1 Res 58 Pendent 6. F1 Res 58 Recessed Pendent/F1 7. F1 Res 58 Recessed Pendent/FP 8. F1 Res 58 CCP Pendent 9. F1 Res 44 & 58 HSW 10. F1 Res 44 & 58 HSW Recessed HSW/F2 11. F1 Res 44 SWC 12. F1 Res 76 Pendent 13. F1 Res 76 Recessed Pendent/F1 14. F1 Res 76 Recessed Pendent/FP 15. F1 Res 76 CCP Pendent Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) 2. NYC MEA 258-93-E Product Description Model F1Res Pendent sprinklers (Figs. 1, 2, 3 & 4) combine excellent durability, high sensitivity glass-bulb and low profile decorative design. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow F1 Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard * Upon fire conditions, rising heat causes a sprinkler’s heat-sensitive glass-bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. F1Res49,58&76 RecessedPendent/F1 F1Res49,58&76 RecessedPendent/FP F1 Res 49, 58 & 76 CCPPendent UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 & 58 Pendent Sprinklers Technical Data:  Thermal Sensor: Nominal 3mm glass-bulb  SprinklerFrame : Brass Casting  Sprinklers’ Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi  Thread Size: ½” NPT (R1/2)  K-Factor:4.9(Actual)-F1Res49PendentSprinkler 5.8 (Actual) - F1Res58Pendent&HSWSprinkler 7.6 (Actual) - F1 Res 76 Pendent Sprinkler 4.4 (Actual) - F1 Res 44 HSWSprinkler  Density: Minimum 0.10 gpm/ft2 F1 Res 44 & 58 Recessed HSW/F2 Model F1 Residential Sprinklers for Design Density of .10 gpm/ft2 F1 Res 44 SWC * Effective date 7/12/02 Vail Fire & Emergency Services 10/09/17 Application Model F1 Res Sprinklers are used for Residential Fire Protection according to UL 1626 Standard*.Besure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The National Fire Protection Association or the approving authority having jurisdiction. When using F1 Residential Sprinklers for systems design to NFPA 13D or NFPA 13R, use listed area of coverageandminimumflowandpressurerequirements shown in Bulletin 135. For systems designed to NFPA 13, use information in thisbulletin.Thenumberofdesignsprinklersshallbethe most hydraulically demanding sprinklers as required by NFPA 13. Flows and pressures can not be below the baseline flows and pressurers. NFPA 13 ForresidentialsprinklersystemsdesignedtoNFPA13, aminimumdensityof0.1gpm/ft2 must beprovidedover the “design area” that includes the four(4) hydraulically most demanding sprinklers for the actual coverage areasbeingprotectedbythe4sprinklers. Theminimum required discharge from each of the four most hydraulically demanding sprinklers shall be the greater of the following: 1.The flow rates given in the Reliable Residential Sprinkler Technical Bulletins referenced in Table A forNFPA13Dand 13R as a function of temperature rating and maximum allowable coverage area (for actual coverage areas less than or between those indicated in the respective technical bulletin, it is required to use the minimum required flow for the next largest coverage area); or 2.A minimum discharge density of 0.1 gpm/ft2 appliedoverthe“designarea”consistingofthefour most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. The maximum dimension of the actual coverage area cannot be any greater than the maximum coverage area indicated in the technical bulletins referenced in Table A. Design Note: Using the As =SxLmethodto determine the sprinklerprotection areaofcoverage in accordance with NFPA 13, apply the 0.1 gpm/ft2 density to this area to determine the minimum required flow. Compare this flow to the minimum 0.05 gpm/ft2 cULus Listed flow for the appropriate coverage area in the technical bulletin for the specificresidentialsprinkler. Iftheflowstatedinthe technical bulletin is less than the calculated 0.1 gpm/ft2 density flow required, the .1 density flow must then be used in the equation Q=K P, solving for P, to establish the minimum required pressure using the sprinkler K-factor. Note: In many cases the listed flow of individual residential sprinklers may exceed the required minimum 0.05 gpm/ft2 density.Reliablehasavailableresidentialsprinklers with larger K-factors (K=5.8 and K=7.6) that will provide lower pressure demands for 0.1 gpm/ft2 densities in NFPA 13 residential applications. Example No. 1 Room Size= 12 ft x 20 ft (3.6 m x 6.1 m) Coverage Area= 12 x 20 = 240 ft2 (22.3 m2) Flow @ 0.10 gpm/ft2 density= 240 x 0.10 = 24 gpm Using an F1 Res 49 Pendent Sprinkler, K=4.9 Pressure= (24/4.9)2 =24psi(1.65bar) The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) coverage area using the baseline density of 0.05 gpm/ft2 will be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Therefore, the minimum flowrequired is 24 gpm @ 24 psi (90.8 L/min @ 1.65 bar). Example No. 2 RoomSize=8ftx20ft(2.4mx6.1m) Coverage Area= 8 x 20 = 160 ft2 (14.9 m2) Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm Using an F1 Res 49 Pendent Sprinkler, K=4.9 Pressure= (16/4.9)2 = 10.7 psi (0.74 bar) The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) coverage area using the baseline density of 0.05 gpm/ft2 will be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Therefore, the minimum flowrequired is 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Example No. 3 Room Size= 10 ft x 16 ft (3.0 m x 4.91 m) Coverage Area= 10 x 16 = 160 ft2 (14.9 m2) Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm Using an F1 Res 76 Pendent Sprinkler, K=7.6 The baseline flow for a 16 ft x 16 ft coverage area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the minimum flow and pressure is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Example No. 4 Room Size= 14 ft x 18 ft (4.3 m x 5.5 m) Coverage Area= 14 x 18 = 252 ft2 (23.6 m2) Flow @ 0.10 gpm/ft2 density= 252 x 0.10 = 25.2 gpm (94.6 L/min) Using an F1 Res 76 Pendent Sprinkler, K=7.6 Pressure= (252/7.6)2 =11psi(0.76bar) The baseline flow and pressure of an 18 ft x 18 ft coverage area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the minimum flow and pressure is 25.2 gpm@11psi(94.6L/min@0.76bar). In general residential sprinklers require flows and pressures as listed for 0.05 densities to achieve the proper spray pattern so the flows and pressures at0.05 densityare the baseline flows and pressures. Flows and pressures below the listed 0.05 density shall not be used. 2. Vail Fire & Emergency Services 10/09/17 Model F1 Res 49, 58 & 76 Pendent Model F1 Res 49, 58 & 76 Recessed Pendent /F1/F2 Fig. 1 Fig. 2 F1 escutcheon, 3 4 (19mm) adjustment 3. Installation Models F1 Res sprinklers are to be installed as shown. Model F1, F2 and FP Escutcheons, illustrated herewith,aretheonlyrecessedescutcheonstobeused with Model F1 Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res Pendent sprinklers use only the Model D sprinkler Wrench; for installing Models F1 Res Recessed Pendent, CCP sprinklers use only the Model GFR2 sprinkler wrench; for installing Model F1 Res recessed HSW sprinklers use only the Model GFR2 Sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Note:A‘leaktight”sprinklerjointcanbeobtainedwith the following torque:  ¾” NPT (R3/4) – 14-20 ft-lbs (19 - 27.1 N-m)  ½” NPT (R1/2) – 8-18 ft-lbs (10.8 – 24.4 N-m) Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. Note: See escutcheon table fordimensions. Vail Fire & Emergency Services 10/09/17 4. Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. Actual K Factor Sprinkler Length Inch (mm) F C F C 1 2 NPT (R1 2) 7 16" (11) 155 175 68 79 175 (12) 100 150 38 66 4.9 2.25 (57) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identification Number (SIN) 12 x 12 (3.6x3.6) 13 (49) 7.0 (0.48) R3516 14 x 14 (4.3x4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9x4.9) 13 (49) 7.0 (0.48) 18 x 18 (5.5x5.5) 17 (64.3) 12.0 (0.83) 20 x 20 (6.1x6.1) 20 (75.7) 16.7 (1.14) Deflector- to - ceiling Maximum 1 (25mm) to 4 (100mm) Type Adjustment Inch(mm) “A” Inch(mm) Faceoffittingto ceiling Inch(mm) F1 3 4 (19.0) Min.= 3 4 (19.1) Max.=11 2 (38.1) 3 16 -15 16 (4.7 - 24.0) F2 1 2 (12.7) Min.=15 16 (23.8) Max.=11 2 (38.1) 3 16 -11 16 (4.7 - 17.4) Escutcheon*, F1 or F2, Data: * Note: Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identification Number (SIN) 12 x 12 (3.6x3.6) 15 (57) 9.4 (0.65) R3516 14 x 14 (4.3x4.3) 16 (60.5) 10.6 (0.73) 16 x 16 (4.9x4.9) 17 (64.3) 12.0 (0.83) 18 x 18 (5.5x5.5) 19 (72) 15.0 (1.0) 20 x 20 (6.1x6.1) 22 (83.2) 20.2 (1.4) *Deflector- to - ceiling Maximum 4 (100mm) to 8 (203mm) *Note: The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth = 7 (178mm) 2.Beamspacingatorgreaterthan7.5ft.(2.3m)oncenter. Technical Data: F1 Res 49 Pendent and Recessed Pendent Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) F C F C ½ NPT (R½) 1 2" (13) 155 175 68 79 175 (12) 100 150 38 66 5.8 2.25 (57) Max. Sprinkler Spacing ft (m) Flow gpm(Lpm) Pressure psi(bar) Ceiling-to- Deflector Inch(mm) Sprinkler Identification Number(SIN) 12 x 12 (3.6x3.6) 16 (61) 7.6 (0.53) 1-4 (25-100) R3513 14 x 14 (4.3x4.3) 16 (61) 7.6 (0.53) 16 x 16 (4.9x4.9) 16 (61) 7.6 (0.53) 18 x 18 (5.5x5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1x6.1) 22 (83.3) 14.4 (1.0) Technical Data: F1 Res 58 Pendent and Recessed Pendent **Baseline flows and pressures for 0.05 density **Baseline flows and pressures for 0.05 density **Calculate for a .10 density but in no case go below the baseline flows & pressures Vail Fire & Emergency Services 10/09/17 5. Model F1 Res 49, 58 & 76 CCP Pendent Model F1 Res 49, 58 & 76 Recessed Pendent /FP FP push-on/thread-off escutcheon Fig. 4 Fig. 3 NOTE: The F1 Res 76 will use a 1" x ¾" reducer. Technical Data: F1 Res 76 Pendent and Recessed Pendent Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) F C F C 3 4 NPT (R3 4) 17 32" (13.5) 155 175 68 79 175 (12) 100 150 38 66 7.6 2.25 (57) Max. Sprinkler Spacing ft (m) Flow gpm(Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12 x 12 (3.6x3.6) 21 7.6 (0.53) R7618 14 x 14 (4.3x4.3) 21 7.6 (0.53) 16 x 16 (4.9x4.9) 21 7.6 (0.53) 18 x 18 (5.5x5.5) 21 7.6 (0.53) 20 x 20 (6.1x6.1) 23 9.2 (0.63) Type Adjustment Inch (mm) “A” Inch(mm) Faceoffittingto ceiling Inch(mm) F1 3 4 (19.0) Min.= 3 4  (19.1) Max.=11 2 (38.1) 3 16 -15 16 (4.7 - 24.0) F2 1 2 (12.7) Min.= 15 16 (23.8) Max.=11 2 (38.1) 3 16 -11 16 (4.7 - 17.4) *Baseline flows and pressures for 0.05 density *Calculate for a .10 density but in no case go below the baseline flows & pressures Vail Fire & Emergency Services 10/09/17 6. Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) F C F °C F C ½ NPT (R½) 7 16" (11) 155 68 135 57 175 (12) 100 38 4.9 2.25 (57) Max. Sprinkler Spacing ft (m) Flow gpm(Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12 x 12 (3.6x3.6) 13 (49) 7.0 (0.48) R3516 14 x 14 (4.3x4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9x4.9) 14 (53) 8.2 (0.56) 18 x 18 (5.5x5.5) 18 (68.1) 13.5 (0.93) 20 x 20 (6.1x6.1) 20 (75.7) 16.7 (1.14) “A” Cover Adjustment Inch (mm) “B” CCP Height Inch (mm) 1 2 (12.7) 15 16 (24) 3 16 (4.7) 3 4 (19) CCP Options Data: FP Position “A” Inch (mm) Max. Recessed 7 16 (11) Min. Recessed 15 16 (24) FP Data “A”: Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent /FP Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) F C F °C F C  NPT (R½) ½" (13) 155 68 135 57 175 (12) 100 38 5.8 2.25 (57) Max. Sprinkler Spacing ft (m) Flow gpm(Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12 x 12 (3.6x3.6) 16 (61) 7.6 (0.53) R3513 14 x 14 (4.3x4.3) 16 (61) 7.6 (0.53) 16 x 16 (4.9x4.9) 16 (61) 7.6 (0.53) 18 x 18 (5.5x5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1x6.1) 22 (83.3) 14.4 (1.0) Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating CCP Assembl yTemp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) F C F °C F C ¾ NPT (R3/4) 17 32" (13.5) 155 175 68 79 135 57 175 (12) 100 150 38 66 7.6 2.25 (57) Max. Sprinkler Spacing ft (m) Flow gpm(Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12 x 12 (3.6x3.6) 21 7.6 (0.53) R7618 14 x 14 (4.3x4.3) 21 7.6 (0.53) 16 x 16 (4.9x4.9) 21 7.6 (0.53) 18 x 18 (5.5x5.5) 22 8.4 (0.58) 20 x 20 (6.1x6.1) 25 10.8 (0.74) Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP *Baseline flows and pressures for 0.05 density *Baseline flows and pressures for 0.05 density *Baseline flows and pressures for 0.05 density *Calculate for a .10 density but in no case go below the baseline flows & pressures Vail Fire & Emergency Services 10/09/17 Model F1 Res 44 & 58 HSW Model F1 Res 44 & 58 Recessed HSW/F2 F2 escutcheon, 1 2 (13mm) adjustment Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) F C F C ½ NPT (R½) 3 8" (10) 155 175 68 79 175 (12) 100 150 38 66 4.4 2.45 (62) Type Adjustment Inch(mm) FaceofFitting to wall Inch(mm) F2 1 2 (13) 3 16 -11 16 (4.7 - 17.4) Escutcheon, F2, Data: Technical Data: F1 Res 44 HSW & HSW/F2 Max.Sprinkler Spacing ft(m) “A” Ceiling-to- Deflector Inch(mm) SprinklerTemp. Rating F(C) Flow gpm (Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12 x 12 (3.6x3.6) 4-6 (101-152) 155 (68) 175 (79) 12 (45.4) 7.5 (0.52) R3531 14 x 14 (4.3x4.3) 155 (68) 175 (79) 14 (53.0) 10.2 (0.71) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 16 (60.6) 13.3 (0.92) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 18 (68.1) 16.8 (1.16) 18 x 18 (5.5x5.5) 155 (68) 175 (79) 19 (72.0) 18.7 (1.29) 16 x 20 (4.9x6.1) 155 (68) 175 (79) 23 (87.1) 27.4 (1.89) 12 x 12 (3.6x3.6) 6-12 (152-305) 155 (68) 175 (79) 14 (53.0) 10.2 (0.71) 14 x 14 (4.3x4.3) 155 (68) 175 (79) 16 (60.6) 13.3 (0.92) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 17 (64.4) 15.0 (1.04) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 20 (75.7) 20.7 (1.43) 16 x 20 (4.9x6.1) 155 (68) 175 (79) 23 (87.1) 27.4 (1.89) *Baseline flows and pressures for 0.05 density *Calculate for a .10 density but in no case go below the baseline flows & pressures 7. Vail Fire & Emergency Services 10/09/17 8. Model F1 Res 44 SWC Fig. 5 Max.Sprinkler Spacing ft(m) “A” Ceiling-to- Deflector Inch(mm) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identification Number(SIN) 12 x 12 (3.6x3.6) 4-6 (101-152) 13 (49.2) 8.7 (0.60) R3531 14 x 14 (4.3x4.3) 14 (53.0) 10.2 (0.71) 16 x 16 (4.9x4.9) 17 (64.3) 15.0 (1.1) 16 x 18 (4.9x5.5) 19 (71.8) 18.7 (1.13) 16 x 20 (4.9x6.1) 23 (87.1) 27.4 (1.89) 12 x 12 (3.6x3.6) 6-12 (152-305) 14 (52.9) 10.2 (0.71) 14 x 14 (4.3x4.3) 15 (56.7) 11.7 (0.81) 16 x 16 (4.9x4.9) 18 (68.1) 16.8 (1.16) 16 x 18 (4.9x5.5) 20 (75.6) 20.7 (1.43) *Baseline flows and pressures for 0.05 density Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating CoverTemp. Rating Max. Pressure psi (bar) Max. AmbientTemp. K Factor Sprinkler Length Inch (mm) F C F °C F C ½ NPT (R½) 3 8" (10) 155 68 135 57 175 (12) 100 38 4.4 2.45 (62) Technical Data: F1 Res 44 SWC *Calculate for a .10 density but in no case go below the baseline flows & pressures Vail Fire & Emergency Services 10/09/17 Thread Size Nominal Orifice Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) F C F C ½ NPT (R½) 1 2" (13) 155 175 68 79 175 (12) 100 150 38 66 5.8 2.45 (62) Type Adjustment Inch(mm) Face ofFitting to wall Inch(mm) F2 1 2 (13) 3 16 -11 16 (4.7 - 17.4) Escutcheon, F2, Data: Technical Data: F1 Res 58 HSW & HSW/F2 Max.Sprinkler Spacing ft(m) “A” Ceiling-to- Deflector Inch(mm) SprinklerTemp. Rating F(C) Flow gpm (Lpm) Pressure psi(bar) Sprinkler Identification Number(SIN) 12 x 12 (3.6x3.6) 4-6 (101-152) 155 (68) 175 (79) 16 (60.6) 7.6 (0.53) R3533 14 x 14 (4.3x4.3) 155 (68) 175 (79) 18 (68.2) 9.7 (0.67) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 21 (79.5) 13.2 (0.91) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 25 (94.7) 18.6 (1.28) 16 x 20 (4.9x6.1) 155 (68) 175 (79) 29 (109.8) 25 (1.73) 12 x 12 (3.6x3.6) 6-12 (152-305) 155 (68) 175 (79) 22 (83.3) 14.4 (1.0) 14 x 14 (4.3x4.3) 155 (68) 175 (79) 22 (83.3) 14.4 (1.0) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 26 (98.4) 20.1 (1.39) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 31 (117.4) 28.6 (1.97) *Baseline flows and pressures for 0.05 density 9. *Calculate for a .10 density but in no case go below the baseline flows & pressures Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish Standard Finishes Sprinkler F1, F2, FP Escutcheons Bronze Chrome Plated White Polyester Coated Brass Bright Chrome Plated White Painted Special Application Finishes Sprinkler F1, F2, Escutcheons Bright Brass Black Plated Black Paint Off White Satin Chrome Bright Brass Black Plated Black Paint Off White Satin Chrome Finishes(1) (1) Other finishes and colors are available on special order. Consult factory for details. Vail Fire & Emergency Services 10/09/17 10. Maintenance Model F1 Res 49, F1 Res 58 & F1 Res 76 Sprinklers should be inspected quarterly, and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R. Donotcleansprinklerwithsoapandwater,Ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which hasbeenpainted (otherthanfactory applied)ordamaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. Thiswillminimizethepotentialfordamagetosprinklersthat could cause improper operation or non-operation. Model F1RES 49 Residential Sprinkler Specifications Model F1 Res 49 & 58 Pendent Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical datasheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installedunderslopedceilingshavingapitchofupto[4/12] [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1” to 8” maximum.Sprinklerframeanddeflectorshallbeofbronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washerandtop-loadedextrudedcupwith3mmglassbulb containing no plastic parts, and having a temperature rating of [155F(68C)] [175F(79C)]. Sprinklers shall have a nominal K-factor of 4.9 & 5.8. Standard finish: [Bronze][Chrome-plated][WhitePolyester][Specialfinish– specify]. Residential pendent sprinklers shall be Reliable ModelF1Res49&58,SINR3516&R3513(Bulletin135). Model F1 Res 49 & 58 Recessed Pendent/F1, Model F1 Res 49 & 58 Recessed Pendent/F2, Model F1 Res 49 & 58 Recessed Pendent/FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pendent sprinklers engineered to provide a minimum designdensityof0.10gpm/ft2overthelistedcoveragearea. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with themanufacturer’s installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1” to 8” maximum. Sprinkler frame and deflectorshall be of bronze frame construction having a½” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155F(68C)] [175F(79C)]. Sprinklers shall have a nominal K-factor of 4.9 (70). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½” adjustment(Model F2)] [with ¾” adjustment (Model F1)] [of push-on and thread off design with ½” adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 49 & 58 Recessed Pendent/F1] [Model F1 Res 49 & 58 Recessed Pendent/F2] [Model F1 Res 49 & 58 Recessed Pendent/FP] SIN R3516 & R3513 (Bulletin 135). ModelF1Res49&58CCPPendent(Concealed) Sprinklers shall be [cULus Listed] [NewYorkCityMEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified bythe manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155F(68C). Cover plate assemblyshallconsistofabrasscoverplateandcopper alloy retainerflange. Method of attaching the coverplate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” cover plate adjustment. Cover plate temperature rating shall be 135F(57C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color– specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 49 & 58 CCP, SIN R3516 & R3513 (Bulletin 135). Vail Fire & Emergency Services 10/09/17 11. Model F1 Res 44 & 58 Horizontal Sidewall Sprinkler Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed forsuch use. Sprinklerframe and deflectorshall beofbronzeframeconstructionhavinga½”NPTthread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155F(68C)] [175F (79C)]. Sprinklers shall have a nominal K-factor of 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester][Specialfinish–specify].Residentialhorizontal sidewall sprinklers shall be Reliable Model F1 Res 58, SIN R3513 (Bulletin 135). Model F1 Res 44 & 58 Recessed Horizontal Sidewall Sprinkler Use description for the Model F1 Res 58 horizontal sidewall sprinkler with the following modifications: Replace “horizontal sidewall sprinkler” with “recessed horizontal sprinkler.” Add: Recessed escutcheon assemblyshall be a steel, two-piece escutcheon with ½” adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish– specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 58/F2, SIN R3513 (Bulletin 135). Model F1 Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum designdensityof0.10gpm/ft2overthelistedcoveragearea. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed inconformancewiththemanufacturer’s installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame constructionhavinga¾”NPTthread. Watersealassembly shallconsistofaTeflon-coatedBellevillespringwasherand machined cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155F(68C)] [175F(79C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 76, SIN R7618 (Bulletin 135). Model F1 Res 76 Recessed Pendent/F1, Model F1 Res 76 Recessed Pendent/F2, Model F1 Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and machined cupwith3mmglassbulbcontainingnoplasticparts,and having a temperature rating of [155F(68C)] [175F (79C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½” adjustment (Model F2)] [with ¾” adjustment(ModelF1)][ofpush-onandthreadoffdesign with ½” adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 76 Recessed Pendent/F1] [Model F1 Res 76 Recessed Pendent/F2] [Model F1 Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model F1 Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum designdensityof0.10gpm/ft2overthelistedcoveragearea. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed inconformance with themanufacturer’sinstallation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame constructionhavinga¾” NPTthread. Watersealassembly shallconsistofaTeflon-coatedBellevillespringwasherand machined cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155F(68C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” cover plate adjustment. Cover plate temperature rating shall be 135F(57C). A plasticprotectivecapshallbeprovidedandfactoryinstalled inside the sprinkler cup to protect the sprinkler from damage, which could occurduring construction before the cover plate is installed. Standard coverplate finish: [White] [Custom Color– specify]. ]. Concealed pendent sprinklers shallbeReliableModelF1Res76CCP,SINR7618(Bulletin 135). Vail Fire & Emergency Services 10/09/17 Reliable...For Complete Protection Reliable offers a wide selection ofsprinklercomponents. Following are some ofthe many precision-madeReliableproductsthatguardlifeandpropertyfromfirearoundtheclock.  Automatic sprinklers  Flush automatic sprinklers  Recessed automatic sprinklers  Concealed automatic sprinklers  Adjustable automatic sprinklers  Dry automatic sprinklers  Intermediate level sprinklers  Open sprinklers  Spray nozzles  Alarm valves  Retarding chambers  Dry pipe valves  Accelerators for dry pipe valves  Mechanical sprinkler alarms  Electrical sprinkler alarm switches  Water flow detectors  Deluge valves  Detector check valves  Check valves  Electrical system  Sprinkler emergency cabinets  Sprinkler wrenches  Sprinklerescutcheonsandguards  Inspectors test connections  Sight drains  Ball drips and drum drips  Control valve seals  Air maintenance devices  Air compressors  Pressure gauges  Identification signs  Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable. ProductsmanufacturedanddistributedbyRELIABLEhavebeenprotectinglifeandpropertyforover80years,andareinstalledandservicedbythemosthighlyqualifiedandreputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Revision lines indicate updated or new data. EG. Printed in U.S.A. 05/08 P/N 9999970322 Recycled Paper Vail Fire & Emergency Services 10/09/17