Loading...
HomeMy WebLinkAboutB17-0142_GA File WP 1296_1500670380 (2).pdf I ==.-600-2006 FIRE RESISTANCE DESIGN MANUAL WALLS AND INTERIOR PARTITIONS, NONCOMB ec01° 1 GA FILE NO. WP 1296 L PROPRIETARY* 1 HOUR l 40 to 143 eft. b FIRE SO GYPSUM WALLBOARD,STEEL STUDS, ,)IQo MINERAL FIBER INSULATION, FIBER-CEMENT BOARD I I _-.e layer 5/8" proprietary type X gypsum wallboard applied parallel to ONE SIDE of 35/8" 07/21/1- steel studs 16"o.c.with 1"Type S drywall screws 8"o.c. at vertical joints and 12" o.c. i i . , ; , , at intermediate studs. 31/2" mineral fiber insulation, 3.0 pcf,friction fit in stud space. + .` t j ++� + 2RPOSITE SIDE: One layer 7/16 proprietary fiber-cement board applied parallel to studs ,', f. . 4with 1" No. 8-18 x 0.323" head diameter ribbed bugle head screws 6"o.c. (NLB) PROPRIETARY GYPSUM BOARD Thickness: 43/4" 9 B America Inc. 5/8" ProRoc®Type X Gypsum Panels Approx.Weight: 7.5 psf Fire Test: OPL 11710-92783,2-13-92 Sound Test: See WP 1350 (NGC 2385,7-28-70) GA FILE NO. WP 1311 1 PROPRIETARY* 1 1 HOUR 1 I 35 to 39 STC FIRE I i SOUND SOLID GYPSUM WALLBOARD One layer 1/2" regular gypsum wallboard or gypsum veneer base applied parallel to each I j I i side of 1" x 24" proprietary type X gypsum panels with laminating compound combed over the entire contact surface and 15/is" Type S screws 24" o.c. horizontally and ' 1 vertically. 1"gypsum coreboard panels attached to 25 gage 1"x 21/4" high "L" runners along floor and ceiling lines with two 15/16"Type S screws at top and bottom.Wallboard layers attached to"L" runners with 17/s"Type S screws 12"o.c. Joints staggered 12"each layer and side. (NLB) Thickness: 2" PROPRIETARY GYPSUM BOARD Limiting Height: 11'0" Approx.Weight: 8 psf National Gypsum Company - 1"Gold Bond®Brand FIRE-SHIELD® Shaftliner Fire Test: FM WP-671, 6-28-82 Sound Test: Based on NGC 2359, 11-18-69 GA FILE NO. WP 1330 I GENERIC 1 HOUR 35 to 39 STC FIRE SOUND SEMI-SOLID GYPSUM WALLBOARD, GYPSUM STUDS ' One layer 5/8"type X gypsum wallboard or gypsum veneer base applied parallel to each side of 6"wide gypsum studs 24"o.c. with 1"Type G drywall screws 20"o.c. and with 4- { i laminating compound. Gypsum studs fabricated from 2 or 3 layers of 1/2" or 5/8" laminated gypsum panels. Fire tested with 1"thick gypsum studs. Sound tested with 5/8"thick gypsum studs. (NLB) Thickness: Varies Limiting Height: 12'0" Approx.Weight: 8 psf Fire Test: UL R2717-19,-21,6-3-57, UL Design U510; ULC Design W502 Sound Test: Based on G&H BW-8FT, 8-1-62 pi 6 'C nt z' manufacturer for more detailed information on proprietary products.