Loading...
HomeMy WebLinkAboutDRB17-0454_Pier location for PRMT Casolar_1507668000.pdf 0 *n IS11.4 „00::;J: 0 00 DRB APPROVED 10/10/2017 12:00:00 AM V 0 W Di Xo- + b PS E z ,_ ,_ ,,, j01 wO STRUCTURAL DESIGNS PO BOX 6230 N/ EAGLE, CO 81631 EE 'RAM NOTE: � / EXST NG BMOz — I PH. a70-331-640 /\ FAX. 1-888-362-4685 •TEMPORARY SHORING / INFO®bPSE.NET PER CONTRACTOR. WWW.bPSE.NET O 2' 4' 8' •• CONTRACTOR TO -1 JACK-UP DECK TO THESE PLANS AND WRITTEN 6. LEVEL. 2 MATERIAL,HEREIN,ARE •UN-AFFECTED DOORS $ / INSTRUMENTS OF SERVICE AND SGAL I/4" = I -O" WINDOWS, NOT SHOWN ARE THE(bPSE). USE SE OF THSFOF bPSE,DRAININGG / OR ANY INFORMATION CONTAINED FOR CLARITY. z WITHIN;ON A PROJECT OTHER THAN NOTES: EXSTNG BM 0 INDICATED IN THE TITLE BLOCK, 15 PROHIBITED WITHOUT WRITTEN PERMISSION FROM bPSE. bPSE 15 �--'•111 0 NOT RESPONSIBLE FOR ERRORS • EXISTING EXTERIOR DECK FLOOR SYSTEM IS 2X10 FLOOR JOISTS W/ 2X DECKING. DUE TO SCALED DRAWINGS. // I REFER ANY QUESTIONS OR • CONTRACTOR TO PROVIDE ICE/ WATER SHIELD AT DECK/ WALL INTERFACE PER ARCH. j Q DISCREPANCIES TO bPSE PRIOR REQUIREMENTS. % EJ NEW 6X6/8X8 TO OR DURING CONSTRUCTION. m COLUMN • ❑ INDICATES COLUMN DOWN OR THRU FRAMING. // • ® INDICATES EXTERIOR WALL . / 4 • - XXXX"-XX" - INDICATES TOP OF BEAM ELEVATION. 6111 • ALL WOOD SILL PLATES IN CONTACT WITH CONCRETE; PROVIDE "GREEN" TREATED HOOD EXSTNG BM cla 0 SILL PLATES ON INSECT AND MOISTURE SUB-SILL SHIELD IN BETWEEN CONCRETE AND PLATE. %� 0 • VERIFY PLATE HEIGHT ELEVATIONS W/ EXISTING CONDITIONS. N • ALL EXTERIOR WALLS ARE ASSUMED TO BE CONSTRUCTED OF 2X6 STUDS SPACED AT 16" / X NEW SIMPSON O.G., TYPICAL, U.N.O. (RE: STRUCTURAL GENERAL NOTES) W/ 1/2" EXTERIOR PLYWOOD. / HHUS HANGER • RE: CONTRACTOR FOR HANDRAIL FRAMING. / W \ / . • THE ENGINEER HAS NOT BEEN ENGAGED FOR CONSTRUCTION SUPERVISION OF ANY KIND, AND -', EXSTNG BM \ z Li) ASSUMES NO RESPONSIBLITY FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN \ U~1 CONNECTION WITH THE CONSTRUCTION WORK. 2 X EXSTNG 2X DECK lU JOISTS, TY'''. �. 0 ;I NEW HOT-TUB PER I— OWNER/ARCH — EXSTNG BM (UN-AFFECTED) Z r� iii in 1.1.1 }K d'� O w < - _1 —1 U O <c LLJ < 0 v >1.. = O \ ATO\ A\ cri V) 0 2' 4' 8' 1.1°611 I- -I 0 SCALE: 1/4 = I -O _CDs Imsom — NOTES: I_ _I am.)0 • FOOTING ELEVATIONS SHOWN ARE BASED ON FINDING ADEQUATE SOIL CONDITIONS AS 0 DETAILED IN THE THE GEOTECHNICAL REPORT. • L] INDICATES CONCRETE FOOTING; SPREAD AND/ OR ISOLATED. • = INDICATES CONCRETE FOUNDATION WALL OR PIER. 1 Z • ( XXXX"-XX" ) INDICATES TOP OF CONC. FOOTING ELEVATION. 0 • [ XXXX"-XX" ] INDICATES TOP OF CONC. FOUNDATION WALL OR PIER ELEVATION. I NEW STEEL • COORDINATE ALL DIMENSIONS AND DETAILS WITH ARCHITECTURAL DRAWINGS. HELICAL PIER W/ 12" 0 CONCRETE • CONTRACTOR SHALL COORDINATE FOUNDATION PLACEMENT WITH AN APPROVED SITE PLAN. 0 PIER CAP 0 1 0 z PLACEMENT INCLUDES ORIENTATION WITHIN BUILDING ENVELOPE/ SETBACK AND 0 1 - 10-kip LOAD - w EV 0 VERIFICATION/ SETTING OF FOUNDATION WALL HEIGHT ELEVATIONS W/ DATUM. Z 0 z • ALL SITE WALLS NOT SHOWN ON THIS PLAN SHALL BE BUILT PER THE SITE PLAN AND __ 0 DETAILS. SITE WALLS SHALL NOT BE CONNECTED TO THE BUILDING UNLESS OTHERWISE I i'a 11 b z z ~ , NOTED. p v v EL 0_ IL tu • THE ENGINEER HAS NOT BEEN ENGAGED FOR CONSTRUCTION SUPERVISION OF ANY KIND, AND \ O I [ 6" ABV GRADE, TYP ] IU ASSUMES NO RESPONSIBLITY FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, 0 * 0 II O O O SEQUENCES AND PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN 0 p p CONNECTION WITH THE CONSTRUCTION WORK. �p 1W ® zo- 0. W W A ,.-- t (� =fos OUCF�+,1 V�L�I••. .P•• Itet \ f r i— , y/� 11 (1 l 1 T / _.1794 I j w w CK/f!-$.1, 09/t9/77 Atel F -I -0- L _I I- -I 1_7_1 O •e - S iONALt \\�\\\\``� IL PROJECT: 0 1401 STRT DT: 8/201/ DRWN BY: PUP SHEET 52 . 1