Loading...
HomeMy WebLinkAboutDRB17-0480_M0.0_1507921380.pdf itr 1411 % ISSUE LOG MECHANICAL SYSTEMS LEGEND 0. ',IF/ / / / / / MECHANICAL SHEET INDEX �0 '� / PIPING DESIGNATIONS PIPING SYMBOLS EQUIPMENT ABBREVIATIONS PLAN ABBREVIATIONS DRB APPROVED 10/13/2017 C 90° ELBOW DN AHU AIR HANDLING UNIT AAV AIR ADMITTANCE VALVE 12:00:00 AM HYDRONIC PIPING 0— 90° ELBOW UP AS AIR SEPARATOR ABV ABOVE —CS— CONDENSER SUPPLY # TITLE C TEE DOWN B BOILER(HOT WATER) AFF ABOVE FINISHED FLOOR —CR— CONDENSER RETURN �Z7 TEE UP BB BASE BOARD AFG ABOVE FINISHED GRADE Q i i / M0.0 MECHANICAL COVER SHEET AND SCHEDULES 4 -Iii- BUTTERFLY VALVE BT BUFFER TANK AUTO AUTOMATIC M0.1 MECHANICAL SPECIFICATIONS 4 —HWS— HEATING WATER SUPPLY —04— SHUT OFF(BALL,GATE, BUTTERFLY) CC COOLING COIL BCS BUILDING CONTROL SYSTEM —HWR— HEATING WATER RETURN —IA— GLOBE VALVE CH CHILLER BDD BACK DRAFT DAMPER z o M1.0 SNOWMELT SYSTEM SITE PLAN J HWS(LT)- HEATING WATER SUPPLY(LOW TEMP) d 0 M1.1 GAS PIPING SITE PLAN 4 —iii— CHECK VALVE CP CIRC PUMP BFG BELOW FINISHED GRADE _ p o HWR(LT)- HEATING WATER RETURN(LOW TEMP) 0 —D.I— FLOW CONTROL VALVE CT COOLING TOWER BLDG BUILDING Oo - I- g) HWS(HT)- HEATING WATER SUPPLY(HIGH TEMP) M2.0 MECHANICAL ROOM PLANS - —a— BALL VALVE CUH CABINET UNIT HEATER B/N BETWEEN o 3 HWR(HT)- HEATING WATER RETURN (HIGH TEMP) (' o -_2 PLUG OR BALANCING VALVE CV CONSTANT VOLUME BOX C COMMON(OR CLOSED) Z -. cnw ID M3.0 MECHANICAL DIAGRAMS 4 — z FLOW BALANCING VALVE DC DUCT COIL CA COMBUSTION AIR 0 N w —SMS— SNOWMELT SUPPLYp J PLUG VALVE IN RISER DEF DISHWASHER EXHAUST FAN CC CONTROLS CONTRACTOR E Z ISSUE LOG KEY: —SMR— SNOWMELT RETURN GATE OR GLOBE VALVE IN RISER EBH ELECTRIC BASEBOARD HEATER 0 CDBBC CONTINUATION DESIGN BUILD '.\1' ISSUED AS PART OF A SETLLI BY CONTRACTOR CO 4-, ' ' NOT PART OF SET N DRAIN VALVE W/HOSE END ECU EVAPORATIVE COOLING UNIT n� H w *' ISSUED FOR INFORMATION ONLY o — FCS — FLOOR COOLING SUPPLY CFM CUBIC FEET PER MINUTE(AIR FLOW RATE) e >. 5 Q � TEMPERATURE CONTROL VALVE(2-WAY) EF EXHAUST FANrn — FCR — FLOOR COOLING RETURN -0i- CIP CAST IN PLACE H w M TEMPERATURE CONTROL VALVE(3 WAY) ERU ENERGY RECOVERY UNIT CLG CEILING(OR COOLING) , § PRESSURE REDUCING VALVE ET EXPANSION TANK CO CLEANOUT Q M IPLUMBING PIPING SOLENOID VALVE EWH ELECTRIC WATER HEATER BOILER SCHEDULE -G- NATURAL GAS CONC CONCRETE VENTURI/FLOW INDICATOR F FURNACE COND CONDENSATE —MG— MEDIUM PRESSURE GAS PUMP&EQUIPMENT CONNECTOR FC FAN COIL HEATING CAPACITY BURNER CONN CONNECT(OR CONNECTION) BOILER FUEL TURNDOWN INPUT L.W.T. E.W.T. VENT MANUFACTURER* Ali— PIPE UNION FP FAN POWERED BOX CONTR'R CONTRACTOR MARK SERVICE TYPE TYPE RATIO @ S.L. OUTPUT MINIMUM (°F) (°F) WATTS VOLT/ TYPE & MODEL# ACCESSORIES REMARKS — D — DRAIN PIPE apo- DOUBLE CHECK BACKFLOW PREVENTER GF GLYCOL FEEDER COTG CLEANOUT TO GRADE (MBH) @ALT. A.F.U.E. PH —X— PIPE ANCHOR H HUMIDIFIER SOS— FUEL OIL SUPPLY CW COLD WATER HEATING FIRE TUBE 6"CAT LOCHINVAR —C1=13— PIPE EXPANSION JOINT HC HEATING COIL B-2 WATER CONDENSING NAT.GAS 7:1 850 800 97 180 160 1440 120/1 IV FTX850N A B —FOR— FUEL OIL RETURN DHR DOMESTIC HOT WATER RECIRC DIRECT FLEXIBLE CONNECTOR HP HEAT PUMP DHW DOMESTIC HOT WATER —FOV— FUEL OIL VENT *- SAFETY RELIEF VALVE HX HEAT EXCHANGER HEATINGB VENT DN DOWN B-1 WATER EXISTING NAT.GAS N/A 1800 - 80 180 160 - 120 CAT 1 EXISTING TO REMAIN - - —FOF— FUEL OIL FILL } AIR VENT KEF KITCHEN EXHAUST FAN DW DOMESTIC WATER T PRESSURE-TEMP.TAP MAU MAKE-UP AIR UNIT DWR DOMESTIC HOT WATER RECIRC —CW— DOMESTIC WATER PRESSURE GAUGE W/PIG TAIL&COCK MCC MOTOR CONTROL CENTER —HW— DOMESTIC HOT WATER (E) EXISTING iiiMV MIXING VALVE EA EXHAUST AIR —HWC— DHW RECIRCULATION THERMOMETER - _ _ - - _ - - - - - - - - - - P PUMP EAT ENTERING AIR TEMPERATURE 140°HW- DOMESTIC HOT WATER(TEMP. SHOWN) y VACUUM BREAKER RF RETURN(OR RELIEF)AIR FAN MANUFACTURERS: I =NS— NON-SOFTENED DOMESTIC WATER EC ELECTRICAL CONTRACTOR STRAINER W/BLOW OFF VALVE RZ RADIANT ZONE EWT ENTERING WATER TEMPERATURE * N/A GENERAL NOTES: —1:41-IM Fs FLOW SWITCH SB SUMP BASIN SHOCK ABSORBER SA SNOWMELT AREA EXH EXHAUST —F— FIRE LINE A: MOTORIZED ISOLATION VALVE;VARIABLE SPEED BOILER CIRCULATOR; CONDENSATE NEUTRALIZATION KIT; FLOW SWITCH. (F) FUTURE B: DIRECT VENT TO EXTERIOR; COMBUSTION AIR FROM ROOM. 0 HORIZONTAL CLEANOUT SF SUPPLY FAN FA FREE AREA —W— WASTE PIPE II VERTICAL CLEANOUT SP SUMP PUMP 0 11.1 —V— PLUMBING VENT PIPE FBO FURNISHED BY OWNER 0 Q FLOOR DRAIN ST STORAGE TANK FCO FLOOR CLEANOUT Lt HEAT EXCHANGER SCHEDULE ® FLOOR SINK TMV THERMOSTATIC MIXING VALVE FCT FOR CONTINUATION 0 —GW— GREASE WASTE PIPE ROOF DRAIN UH UNIT HEATER ® FD FIRE DAMPER 0 MAX HEAT —GV— GREASE VENT •Of DECK/ROOF DRAIN ABOVE VR VARIABLE VOLUME BOX W/REHEAT E.W.T. L.W.T. FOULING MANUFACTURER* & \/ FFI FOR FURTHER INFORMATION MARK SERVICE TYPE SIDE GPM FLUIDPRESSURE TRANSFER ACCESSORIES REMARKS —ST— STORM DRAIN PIPE — Z ti (°F) (°F) FACTOR MODEL# _ Tc TEMPERATURE CONTROLLER OR SENSOR VV VARIABLE VOLUME BOX DROP (PSI) (MBH) FSD COMBINATION FIRE/SMOKE DAMPER Q Z -ST(OF)- STORM DRAIN OVERFLOW H B WH WATER HEATER > O co HOT 30 20%GLYCOL 180 150 6 —SD— SECONDARY DRAIN HOSE BIBS GC GENERAL CONTRACTOR — 00 00 BRAZED «1��1 I (n HX-1 SNOWMELT 1.0 500 TRIANGLE TUBE TB1OT - - GHX GROUND HEAT EXCHANGER PLATE COLD 30 50%GLYCOL 110 140 7.3 —SO— SAND AND OIL WASTEW H z O GPM GALLONS PER MINUTE(WATER FLOW RATE) w Q CD HOT WALL HYDRANT PLAN SYMBOLS w 0 O _ _ _ _ _ _ _ _ HP HORSEPOWER Q d COLD - - - - - I STEAM TRAP TEST CHAMBER G CONTROL PANEL/RADIANT MANIFOLD HW HOT WATER X 2 MANUFACTURERS: REFERENCE SAMPLE © p CARBON DIOXIDE SENSOR W 0 0 STEAM TRAP: HWC HOT WATER RECIRC w J o * B&G, PATTERSON-KELLY,TACO,TRANTER FT-FLOAT&THERMOSTATIC 9 CARBON MONOXIDE SENSOR J w O TD-THERMODYNAMIC CO (/) U) ILO IN LIEU OF GENERAL NOTES: RE: B/M400 FFI 0 HUMIDISTAT U IB INVERTED BUCKET CDWATTS TS THERMOSTATIC p REMOTE TEMPERATURE SENSOR D >- J B: KAT LEW O NG AIR TEMPERATURE O u) Q Z B. FFI = FOR FURTHER INFORMATION BP BALANCED PRESSURE 0 THERMOSTAT Q FCT=FOR CONTINUATION LF LINEAR FOOT H > f SP DUCT STATIC PRESSURE SENSOR O SHEET NUMBER NOTES 0 ROOM PRESSURE SENSOR LWT LEAVING WATER TEMPERATURE W PUMP SCHEDULEEMERGENCY POWER OFF SWITCH DRAWING NUMBER OR MC MECHANICAL CONTRACTOR Z DIAGRAM LETTER 1. ALL SYMBOLS,ABBREVIATIONS,AND DESIGNATIONS ON LEGEND SHEET ARE NOT NECESSARILY USED ON P MFG MANUFACTURER MOTOR MANUFACTURER* e PLUMBING/HVAC RISER O x MARK SERVICE TYPE GPM TDH (FT) FLUID VOLT/ ACCESSORIES REMARKS REFER TO: THIS PROJECT. MOD MOTOR OPERATED DAMPER Z 8 in WATTS RPM PH & MODEL# DIAGRAM CONTINUATION REFERENCE w 2. THIS DRAWING SET CONSISTS OF DATA GENERATED, IN SECTION CUT LETTER/SHEET SHOWN ON (N) NEW PART, BY OTHER PARTIES. NOT ALL SYMBOLOGIES AND mBP-1 EXISTING IN-LINE - - 20% PROP - - - EXISTING TO REMAIN N/A N/A NOTATION CONVENTIONS OCCURRING IN THIS WI POINT OF DISCONNECTIONCC NC NORMALLY CLOSED Q CD GLYCOL DRAWING SET ARE NECESSARILY DEFINED ON THESE NEC NATIONAL ELECTRIC CODE D- LEGENDS.CONSULT THE ENGINEER IN THE EVENT 0 POINT OF NEW CONNECTION NIC NOT IN CONTRACT SYMBOLOGY OR NOTATION INTERPRETATION IS n 20% PROP VARIABLE ACCESS PANEL BP-2 B-2 IN-LINE 55 5 600 120/1 PROVIDED WITH BOILER REQUIRED. in GLYCOL SPEED G NO NORMALLY OPEN } SNOWMELT MANIFOLD c) OA OUTSIDE AIR Current Issue: H SNOWMELT 20% PROP JSMHXP-1 HEAT IN-LINE 60 20 640 3 SPEED 208/3 GRUNDFOS UPS 50-80/4 F CONTROL RELAY - OBD OPPOSED BLADE VOLUME DAMPER w GLYCOL 2 EXCHANGER PERMIT SET OC ON CENTER 0 50%PROP OSA OUTSIDE AIR z SP-1 SNOWMELT IN-LINE 60 40 GLYCOL 1300 3 SPEED 208/3 GRUNDFOS UPS 50-160 F CONTROL RELAY PROJECT ALTITUDE CD RA RETURN AIR Issued: 8150' ABOVE SEA LEVEL RE: REFER TO: X W REQ'D REQUIRED PERMIT ET 10.10.2017 J > MANUFACTURERS: REQ'MTS REQUIREMENTS in * N/A SA SUPPLY AIR in CC GENERAL NOTES: SF SQUARE FOOT(FEET) m A. SP STATIC PRESSURE D B: 0 SS STAINLESS STEEL 0 o TA THROW-AWAY(TRANSFER AIR) MISCELLANEOUS MECHANICAL EQUIPMENT SCHEDULE17 TYP TYPICAL oo u) UNO UNLESS NOTED OTHERWISE I- ELECTRICAL U MANUFACTURER* W/ WITH in MARK SERVICE TYPE CAPACITY VOLT/ ACCESSORIES REMARKS 3 WATTS PH & MODEL# W/O WITHOUT Sheet Title: CD SNOWMELT WCO WALL CLEANOUT MECHANICAL m AS-2 AIR IN-LINE LINE SIZE N/A N/A TACO ACO25-125 - WRT WITH REGARD TO HEPERATOR COVER SHEET Q W/C WATER COOLED 0 SNOWMELT AND SCHEDULES C Q EXT-2 EXPANSION BLADDER 23/10 N/A N/A TACO CX84-125 - - VTR VENT THRU ROOF TANK XFR TRANSFER CC SNOWMELT w LOW LEVEL ALARM 0 DIAMETER Date: 10.10.2017 U GF-2 GLYCOL N/A 55 GALLON 84 120/1 AXIOM SF100 - CD FEEDER PANEL Designed: DAL Reviewed: DAL m_ MANUFACTURERS: No: 9714.03 • � t a GENERAL NOTES: k Sheet No: 11 A: O B. 4) `F4;., i; . COi. • N - M0 . 0 N. ■ Nu d Scale: As Shown