Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PEC17-0040_A0.00_1507668480.pdf
.4,112".. 4401. 5 a cc IS ir ROCKLEDGE ROAD RESIDENCE 011 PEC APPROVED 10/9/2017 12:00:00 A 307 ROCKLEDGE RVAIL, CO 81657 MATERIAL SYMBOLS : ABBREVIATIONS: GENERAL NOTES: DRAWING INDEX: GENERAL AND SITE N o 11 HI HI A0.00 COVER b U EARTH // // PLYWOOD Nr 11 HI IIIABV ABOVE L LENGTH 01 DO NOT SCALE DRAWINGS TOPOGRAPHIC SURVEY m AFF ABOVE FINISHED FLOOR LDT LIGHT AND DRAPERY TROUGH o r AP ACCESS PANEL LT LIGHT TROUGH ° L o POROUS FILL/DRAINAGE �f .- FINISH WOOD AC ACOUSTICAL LTL LINTEL 02 VERIFY ALL DIMENSIONS, CONDITIONS AND UTILITY LOCATIONS ON A1 .01 ARCHITECTURAL SITE PLAN u ADD ADDENDUM LVR LOUVER THE JOB SITE PRIOR TO BEGINNING ANY WORK OR ORDERING u ADJ ADJACENT MH MANHOLE ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR E ALT ALTERNATE MFR MANUFACTURE (ER) DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. DRAWING INDEX: ARCHITECTURAL �� �� 03 AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY a ////j%, STONE MASONRY WOOD ROUGH ALUM ALUMINUM MO MASONRY OPENING a� ARCH ARCHITECT (URAL) MIL METAL RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECT BEFORE A2.00 GRFA/SITE COVERAGE CALCULATIONS _c BSMT BASEMENT MAX MAXIMUM CONSTRUCTION CONTINUES IN THOSE AREAS. E BRG BEARING MECH MECHANIC (AL) A2.01 LOWER LEVEL PLAN BVL BEVELED MC MEDICINE CABINET STRUCTURAL CONCRETE BLOCKING 04 PLAN DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE, Zt° BIT BITUMINUOUS MEM MEMBRANE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE A2.02 MAIN LEVEL PLAN !i o BLK BLOCK M METER (S) TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BLKG BLOCKING MM MILLIMETER (S) BEAMS UNLESS OTHERWISE NOTED. A2.03 UPPER LEVEL PLAN 1111C 1.11 cN. CONCRETE MASONRY UNIT GYPSUM BOARD BOT BOTTOM MIN MINIMUM AZ.O4 ROOF PLAN X �" 0 BLDG BUILDING MIR MIRROR 05 PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. _ w CPT CARPET (ED) MISC MISCELLANEOUS LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL A3.00 BASEMENT EXCLUSION CALCULATIONS N 0 CSMT CASEMENT MULL MULLION MOUNTED FIXTURES,TOILETS,TOILET ACCESSORIES, CABINETRY, w N BATT INSULATION C CAULK (ING) NAT NATURAL COUNTERTOPS,SHELVES AND CLOSET RODS. A3.01 BUILDING ELEVATION Ur CLG CEILING NR NOISE REDUCTION Q n 0 CT CERAMIC TILE NOM NOMINAL 06 n DENOTES DOORS. REFER TO FLOOR PLANS FOR LOCATIONS. REFER A3.02 BUILDING ELEVATION CLR CLEAR NIC NOT IN CONTRACT TO DOOR SCHEDULE FOR DOOR TYPES. RIGID INSULATION COD CARBON MONOXIDE DETECTOR NTS NOT TO SCALE COL COLUMN OPG OPENING 07 O DENOTES WINDOWS. REFER TO WINDOWS AND FLOOR PLANS FOR A3.03 BUILDINGELEVATION CONC CONCRETE OPP OPPOSITE LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. A3.04 BUILDING ELEVATION CMU CONCRETE MASONRY UNIT OPH OPPOSITE HAND 1/ // I STEEL/METAL AS NOTED CONST CONSTRUCTION OH OVERHEAD A4.01 BUILDING SECTION 1111 CONT CONTINUOUS PR PAIR 08 COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT CJT CONTROL JOINT PK PARKING WITHIN CEILING, FLOOR AND WALLS SPACES. VERIFY LOCATIONS WITH A4.02 BUILDING SECTION (1111) CPR COPPER PVMT PAVEMENT CARPET CUST CUSTOM PL PLASTIC LAMINATE ARCHITECT. 11111111 DT DRAPERY TROUGH PT POINT DTL DETAIL PSF POUNDS PER SQUARE FOOT 09 IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BYZ DIM DIMENSION PSI POUNDS PER SQUARE INCH THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECTS OF THIS DR DOOR PL PROPERTY LINE PROJECT, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE DRW DRAWING QT QUARRY TILE ARCHITECT. 1111 DF DRINKING FOUNTAIN REF REFERENCE I Alk ELEC ELECTRIC (AL) REF REFRIGERATOR 0 EL ELEVATION (S) REIN REINFORCE (D), (ING) 10 THE CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL A4.00 A4.00APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED ELEV ELEVATOR REQ REQUIRED EQ EQUAL RES RESILIENT APPROVALS. THIS PROJECT IS GOVERNED BY THE INTERNATIONAL EXH EXHAUST REV REVISION (D), (ING) BUILDING CODE. CODE COMPLIANCE IS MANDATORY.THE - BUILDING SECTION REFERENCE ELEVATION REFERENCE EXTG EXISTING REV REVERSE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES EXT EXTERIOR RH RIGHT HAND NOT CONFORM TO ALL RELEVANT CODES INCLUDING IBC AND ALL FOC FACE OF CONCRETE R RISER LOCAL AND REGIONAL CODES. (1) FOF FACE OF FINISH R&S ROD AND SHELF FOM FACE OF MASONRY RD ROOF DRAIN 11 THE CONTRACTOR SHALL FIELD COORDINATE AND OBTAIN Q1.1.1 j FOS FACE OF STUDS RDT RECESSED DRAPERY TRACK APPROVAL FROM THE ARCHITECT & ENGINEER BEFORE ANY a A400 1 A4.00 FIN FINISH (ED) RFG ROOFING CUTTING, NOTCHING OR DRILLING OF ANY CAST-IN-PLACE 4 g ..-.../ FFE FINISHED FLOOR ELEVATION RM ROOM CONCRETE,STEEL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS FE FIRE EXTINGUISHER RO ROUGH OPENING WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDING. FDC FIRE DEPARTMENT CONNECTION R/S ROUGH SAWN LY DETAIL REFERENCE DETAIL REFERENCE FHC FIRE HOSE CONNECTION S SEALANT (EXTERIOR) CI 0 FEC FIRE EXTINGUISHER CABINET SHTG SHEATHING W FP FIREPLACE SHH SHOWER HEAD 12 THE CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND STAKE . 0 MAIN 1 FPS FIREPROOFING, SPRAYED SHC SHOWER CONTROLS OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT 1,1,10 FLG FLASHING SM SHEET METAL APPROVAL PRIOR TO BEGINNING ANY SITE WORK. V J 100'-0" A4.00 0 FLR FLOOR (ING) SIM SIMILAR cc Ci ZE FD FLOOR DRAIN SC SOLID CORE 13 IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE HEIGHT REFERENCE FTG FOOTING SPEC SPECIFICATON (S) CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, h SECTION REFERENCE FND FOUNDATION SQ SQUARE MATERIALS,TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC.TO OBTAIN M 12 FBO FURNISHED BY OTHERS STD STANDARD A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE ^.„0,w) FPHB FREEZE PROOF HOSE BIB ST STAIN INDUSTRY. FUR FURRED (ING) STL STEEL ROOM NAME GA GAGE, GAUGE SD STORM DRAIN 14 ALL BUILDINGS TO FIT WITHIN PROPERTY LINES WITHOUT CROSSING GALV GALVANIZED STR STRUCTURAL EASEMENTS OR SETBACKS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 1111 AGC GENERAL CONTRACT (OR) TEL TELEPHONE REVISION REFERENCE GL GLASS, GLAZING TV TELEVISION ROOM NAME GYP GYPSUM BOARD THR THRESHOLD 15 PROVIDE ACCESS PANEL TO MOTOR FOR ALL WHIRLPOOL-TYPE TUBS. HB HOSE BIB T&G TONGUE AND GROOVE COORDINATE ACCESS LOCATIONS WITH INTERIOR DESIGNER AND HDW HARDWARE TOS TOP OF SLAB ARCHITECT TO PROVIDE INCONSPICUOUS LOCATION. HDR HEADER TOS TOP OF STEEL HTG HEATING TOW TOP OF WALL GRID W11 HVAC HEATING/VENTILATING/AC TB TOWEL BAR HT HEIGHT TR TRANSOM PROJECT SUMMARY. CIII) HC HOLLOW CORE T TREAD GRID BUBBLE WALL TYPE REFERENCE HM HOLLOW METAL TYP TYPICAL 0 HOR HORIZONTAL UNO UNLESS NOTED OTHERWISE Code: HWH HOT WATER HEATER VB VAPOR BARRIER International Residential Code 2015 1 INCL INCLUDE (D), (ING) VIF VERIFY IN FIELD Occupancy: One-Family Dwelling ID INSIDE DIAMETER VERT VERTICAL IBC INSTALLED BY CONTRACTOR 'BO INSTALLED BY OWNER VCT VINYL COMPOSITION WC WATER CLOSET Separations: 4 A8.1 2 1 Hour (residence/garage) 11 CC INS INSULATE (D), (ION) WP WATER PROOFING 1 Hour (residence/mechanical) 3 INT INTERIOR WWF WELDED WIRE FABRIC JC JANITOR'S CLOSET W WIDTH, WIDE Special Attributes: ent Addressable Fire Alarm INTERIOR ELEVATION REFERENCE WINDOW TAG KIT KITCHEN WDW WINDOW Intelligent ISSUED FOR: DATE: LAM LAMINATE (D) WO WITHOUT Automatic Sprinkler System as LAV LAVATORY WD WOOD required by Town of Vail SCHEMATIC DESIGN 6.13.17 LH LEFT HAND TOV CONCEPTUAL REVIEW 6.26.17 ® STN---/--TILE DOOR TAG MATERIAL BREAK COPY RIGHT RESERVATION The drawings, specifications and other documents prepared by the Architect (Michael Suman Architect, LLC) for this project are instruments of the Architect's service for use solely with respect to this Project and, unless otherwise provided in writing, the Architect shall be deemed the sole and exclusive author of these documents and shall retain,without limitation, all common law, statutory and other reversed rights, includingthe copyright hereof. No person,whether © 2017 MICHAEL SUMAN ARCHITECT,LLC. ALL RIGHTS RESERVED. having come rightly into possession hereof or otherwise, shall employ these documents on any other project, nor SCALE: for additions to this Project nor for the completion of this DRAWN: MDS Project by others, unless with the prior express written consent of the Architect and upon appropriate compensation to the Architect in an amount and kind PROJECT#: 1601 satisfactory to the Architect. The Architect expressly SHEET TITLE: COVER SHEET claims all proprietary rights in the material which is issued in confidence for design and/or construction purposes of this Project as noted. These materials may not be copied, modified, nor employed in any way without the specific prior written consent and permission of the Architect. A0100 ©2017 Michael Suman Architect, LLC. All rights reserved.