HomeMy WebLinkAboutPEC17-0040_A4.02_1507668480.pdf " OF 1'4 4G;* a cc X IS ir 3q0/' PEC GENERAL ASSEMBLY NOTES: APPROVED ROOF CEILING ASSEMBLY 10/9/201712:00:00nA •STANDING SEAM METAL ROOF OVER • ROOF WATERPROOF MEMBRANE OVER •3 2" RIGID INSULATION AND SHEATHING_R-18 MIN. •STRUCTURAL PLYWOOD SHEATHING OVER (RE:STRUCTURAL) OVER • 2"SPRAY FOAM INSULATION AT BOTTOM SIDE OF SHEATHING_R-12.4 MIN. •STRUCTURAL ROOF JOISTS (RE: STRUCTURAL) • 12" BLOWN-IN BLANKET INSULATION AT JOIST CAVITIES_R-48 MIN. (R-78.4 MIN.TOTAL) • 2 MIL SMART MEMBRANE VAPOR RETARDER • lx6 T&G DECKING OR DRYWALL PER REFLECTED CEILING PLANS FLAT ROOF CEILING ASSEMBLY - o \\ • STONE BALLAST ON ui •• P OTECT ON LAYER OVER 7 t, • FULLY-ADHERED EPDM ROOFING MEMBRANE ON o m \\ \ • ADHERED COVER BOARD OVER a U - MECHANICALLY-ATTACHED RIGID BOARD INSULATION 3"MINIMUM AT DRAINS OVER HABITABLE 0 --- � c SPACER 18.0 MIN. 0 • TAPERED RIGID INSULATION E • STRUCTURAL PLYWOOD SHEATHING OVER (RE: STRUCTURAL) H \ 30' 0" HEIGHT LINE • 2"SPRAY FOAM INSULATION AT BOTTOM SIDE OF SHEATHING R-12.4 MIN. • STRUCTURAL ROOF JOISTS UNLESS NOTED OTHERWISE (RE: STRUCTURAL) C \\ s-.. \\ 33' 0" HEIGHT LINE • 12" BLOWN IN BLANKET INSULATION IN CAVITY OVER HABITABLE SPACER 48 MIN. (R-78.4 TOTAL) -, \ • 2 MIL SMART MEMBRANE VAPOR RETARDER E • 1x6 T&G DECKING OR DRYWALL PER REFLECTED CEILING PLANS WI) c) �\ �- I- 12 STEEL ROOF SUPPORTS AND ALL STEEL STRUCTURE AT EXTERIOR TO INTERIOR TRANSITION 44 v • ENCAPSULATE AT INTERIOR SIDE WITH 1 1/2"MIN. SPRAY FOAM INSULATION TO MIN. 4'-0" o --...I..----2 \\ INSIDE FROM EXT RIOR FACE OF EXTERIOR WALLS; MAKE CONTINUOUS WITH SPRAY FOAM o \ \ INSULATION IN R OF AND WALLS tik _ 12 1.-- \ FLOOR CEILING ASSEMB U 6' N 0 I t •SEE PLANS FOR FI ISH Ix w N \ VI At • _ \\ \ \ • 1 2' GYP-CRETE WTTH RADIANT HEAT LOOPS OVER \ • PLYWOOD DECKI JG (RE:STRUCTURAL)OVER i : •STRUCTURAL MEN BERS (RE:STRUCTURAL) \ • BLOWN-IN BLANI -T INSULATION AT JOIST CAVITIES_R-38 MIN. --- •2' HAT CHANNEL CR$'SUSPENDED METAL GRID PER SECTIONS 11 :----------s- ----- - � •SEE RCP'S FOR CEILING FINISH I la SLAB ON GRADE ASSEMB Y(INTERIOR FLOOR SLABS ONLY) •SEE PLANS FOR FI ISH •STRUCTURAL CO CRETE SLAB WITH • HYDRONIC HEAT UBING OVER • 15 MIL POLYETHY NE VAPOR DIFFUSION RETARDER OVER I- II r \ • RIGID INSULATIO R-10 MIN. OVER (1) I • 6"GRAVEL BALLAfTZ L_ --- FRAMED EXTERIOR WALL la • SEE ELEVATIONS F R FINISH • HOME SLICKER RAI SCREEN OVER ,�i -... ,. • AIR BARRIER/WE HER-RESISTIVE BARRIER OVER • t �OOD SHEA HING ON � \ � • 2X6 WOO�'ST-UpSJ I ENTRY - \\ • 3"SPRAY FOAM If�Si`}L,ATION AT INSIDE FACE OF SHEATHING_R 18.6 MIN. 12 - - • 2.5"BLOWN-IN BL NKET IN�U.LATION_R-10 MIN. (R-28.6 TOTAL) R R F FOUNDATION-WALLS • DRAIN ARIDDR OARD BY MAR-FLEX -1&)OVER • HOT-FLUID APPLI -9/'A-TE PROOFING OVER\ lin • i OPEN STEEL TRUSS TYP. II • 2x FURRING AONDINSULOATION PE AN ONNTERIO\9 MINIMUM a CNCRETEWALL (RE:STRUCTURAby 11111 ___, FRAMED INTERIOR ARTITION WALLS \ \ 1 .-5 \ \ I ® • BLOWN-IN CELLU OSE INSULATION \ \ WCC 1 CONDITIONED CR WLSPACE WALLSCC \ \ 0 0 117 • DRAIN AND DRY OARD BY MAR-FLEXR-10 OVER • HOT-FLUID APPLIJ � O W WATERPROOFING OVER \ \ 1 LIVING • CONCRETE FOU ATION WALL (RE:STRUCTURAL) \ \ k v = ROOM 1 • 2X FURRING AND INSULATION PER PLAN ON INTERIOR_R-9 MINIMUM\\ \\ O J STORAGE/ - Q LAUNDRY N \\ N - IEEE W O & .... 1.1= I 1 CI) WINE ROOM N FAMILY ROOM 1 - i CC HISTORICAL GRADE LINE y'^ ISSUED FOR: DATE: FEEM6_ I � I SCF6C DESIGN DDITH.17 • •o I TOV CONCEPTUAL REVIEW 6.26.17 1•461 l O l I I (/ 20MICHAEL SUMAN ARCHITECT,LLC. \�� ALL RIGHTS RESERVED. SCALE: 1/4"=V-0" DRAWN: PROJECT#: 1601 I I SHEET TITLE: SECTIONS 1 SITE SECTION A4. 02 A4.02 SCALE: 1/4" = 1-0"