Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PEC17-0010_A252_1508779461.pdf
.,„.,....." 0„4, , ,e.,, z 4 BUILDING SECTION NOTES BUILDING SECTION ASSEMBLIES BUILDING SECTION ASSEMBLIES TOWN OFVAILUSE7.71 iV 1. COORDINATENEW WORK WITHDEMOLITIONPLANS. TYPICAL ROOF ASSEMBLY TYPICAL WOOD SIDING WALL ASSEMBLY (LEVEL 2 &3) T10YPICAL TYPICAL LEVEL 1 FLOOR ASSEMBLY ) TYPICAL STONE VENEER WALL ASSEMBLY 2. RE:STRUC.FOR NEW COLUMN LOCATI ONS,REI NFORCEDCOLUMNS&BEAMS,AND FLOOR&CEI LI NGPENETRATI ONS. PEC 3. RE:MEP FOR DUCT&VENT LOCATIONS COPPER ROOF SHINGLE PANELS STAINED RUSTIC WOOD LAP SIDING WITH LIVE EDGE OVER APPROVED 4. VERIFYEXISTI NGDIMENSIONS&CONSTRUCTIONASSEMBLIESPRIORTOPROCEEDINGWITHWORK. EXISTING FLOOR FINISH OVER 4" STONE VENEER W/WEEPS AS REQ'D 5/22/201712:00:00AM W/ COPPER CLEATS OVER EXISTING PLYWOOD SUBFLOOR 30#BLDG. PAPER ON 1/8" DRAINAGE MAT 5. FI NAL EXTERI ORI NSULATI ONR-VALUE AND THI CKNESSDEPENDENT ON LOCATION. 30 LB. ROOFING FELT OVER (HIGH-HEAT) OVER EXISTING 2X WOOD JOIST 3/4" EXT. PLYWOOD SHEATHING (R-0.8) OVER 2" RIGID POLYISO (R-11.4) OVER WEATHER RESISTIVE BARRIER OVER 6. MAINTAINALLREQUIREDFIRERATEDASSEMBLIES. ICE&WATER SHIELD UNDERLAYMENT OVER EXISTING GWB CEILING 1/8" DRAINAGE MAT OVER 5/8" EXT PLYWOOD SHEATHING (R-0.6) ON 7. PROVI DEACOUSTICISOLATI ONBETWEEN RESI IJENCE&TENANT SPACE WHEREVER POSSIBLE. ATLAS-ACFOAM 4-1/2" NAILBASE, EXISTING SPRINKLER SYSTEM 2"TYP. (R-11.4) RIGID POLYISO INSULATION OVER 8. INTERIORFINISHESTBD. 2X6 EXISTING or NEW STUD WALL PER STRL. WITH CLOSED-CELL 9. SEE ELEVATI ONSFOR WALL FINISHES. INSULATION (ASSUME TOTAL R-VALUE=24.2) OVER WEATHER RESISTIVE BARRIER OVER SPRAY INSULATION (R-33) 4-1/2" POLYISO INSULATION (ASSUME Total R-VALUE =26.8) OVER 5/8" EXT. PLYWOOD SHEATHING (R-0.6) ON or SELF-ADHERING MEMBRANE AIR/VAPOR BARRIER OVER TYPICAL BASEMENT LEVEL FLOOR ASSEMBLY 2X6 EXISTING or NEW STUD WALL PER STRL. WITH CLOSED-CELL DOUBLE WIDTH BRICK WALL WITH 2" INSULATION IN CAVITY(R-10) EXISTING CONSTRUCTION TO REMAIN; NO WORK 1/2" PLYWOOD PER STRUCTURAL OVER, (ASSUME TOTAL SPRAY INSULATION (R-33) 5/8" G.W.B. (R-0.6), I IN THESE AREAS EXCEPT AS OTHERWISE REQ'D R-VALUE=0.62) OVER EXISTING FLOOR FINISH OVER 5/8" G.W.B., RE: STRUCT. &SPEC.,TYP. IN DRAWINGS&SPECIFICATIONS. T&G DOUG-FIR ROOF DECKING, (ASSUME TOTAL R-VALUE=3), RE: SPEC. EXISTING CONCRETE SLAB RE: STRUCT. &SPEC.,TYP. FINAL INTERIOR FINISH TBD A OVER FINAL INTERIOR FINISH TBD COPPER BYLIN ROOF ICE MELT SYSTEM AT PERIMETER Of C0 j 0 1 HR RATED ASSEMBLY, RE: SHEET 6010 EXPOSED ROOF BEAMS, RAFTERS&PURLINS PER STRL. TYPICAL EXTERIOR BALCONY FLOOR ASSEMBLY OVER HEATED SPACE TYPICAL WOOD FRAME & PANEL SIDING ASSEMBLY TYPICAL STUCCO WALL ASSEMBLY •S(<1 4) SNOW GUARD PER ROOF PLAN '9 10 VERIFYALL NEW OR REMODELEDASSEMBLIESCOMPLYWITH2015 I ECC CHAPTERS PERSCRIPTIVE APPROACH 3/4" STONE TILE&THINSET ON WOOD FRAME& PANEL SIDING (R-0.8) OVER ±7/8" STUCCO VENEER (R-0.2) OVER jQ D° IAN O TOWN OF VAILTHERMALCLIMATEZONE:68 TYPICAL LEVEL 3 FLOOR ASSEMBLY SLOPED WATERPROOFING ON 30#BLDG. PAPER ON 2 LAYERS WATER RESISTANT BARRIER 0 �� l, _ INSULATIONVALUES: 1 1/2" MORTAR BED WITH RADIANT SNOW MELT ON 3/4" EXT. PLYWOOD SHEATHING (R-0.8) OVER 5/8" CEMENT BOARD (R-0.3) OVER BIEKER ROOF: R-49 MI N(R-54 PROVIDED) 3/4" WOOD FLOORING (TILE IN BATHROOMS,WOOD or CARPET IN 1/4" DRAIN BD. ON 1/8" DRAINAGE MAT OVER 2"TO 4" (R-11.4 TO R-41.3) RIGID POLYISO INSULATION OVER /.... C 0 0400 0 WOOD FRAMED WALL: R-13 + R-7.5ci-or-R-20+ R-3.8ci(R-43-74 PROVIDED) BEDROOMS&CLOSETS) CONT. WATERPROOF MEMBRANE ON 2" (R-11.4) RIGID POLYISO INSULATION OVER WEATHER RESISTIVE BARRIER OVER � . AI �V MASS WALL: R-15.2ci (R-22 PROVIDED) 1-1/8" WARMBOARD-S SLOPED MORTAR OVER SLIP SHEET(1/8" PER FT. MIN.) ON WEATHER RESISTIVE BARRIER OVER 5/8" EXT. PLYWOOD SHEATHING <% . 'PP �� BELOW GRADE WALLS: R-10ci (NO NEW BELOW GRADE WALLSENCLOSINGHABITABLESPACE) 11-7/8" BCI'S PER STRUCTURAL 3/4" EXT PLYWOOD SHEATHING ON 5/8" EXT. PLYWOOD SHEATHING (R-0.6) ON 2X6 EXISTING or NEW STUD WALL PER STRL. WITH CLOSED-CELL •Y ED ARG‘ WOOF FRAMED FLOORS: R-30(R-30 MIN.PROVIDED) 3-1/2" DROPPED FURRING EXISTING 2X WOOD JOISTS OR REINFORCED FRAMING PER STRUCT. 2X6 STUD WALL PER STRL. WITH CLOSED-CELL SPRAY INSULATION SPRAY INSULATION (R-33) HEATED SLAB ON GRADE: R-20 FOR 48"BELOW(R-20 MI N.PROVIDED) 1/2" SOUND BOARD WITH R-30 MIN.SPRAY FOAM INSULATION (R-33) or UNHEATED S.O.B.: R-15 FOR 24"BELOW 1/2" RESILIENT CHANNEL EXISTING OR NEW 5/8" GWB CEILING (FIRE SEPARATION AS REQ'D) 5/8" G.W.B., DOUBLE WIDTH BRICK WALL WITH 2" INSULATION IN CAVITY(R-10) OPAQUE NONSWI NGI NGDOORS: R-4.75 3/4" WOOD PANELING EXISTING SPRINKLER SYSTEM RE: STRUCT. &SPEC.,TYP. 5/8" G.W.B.(R-0.6), WOOD DOORS: U-0.5(U-0.5 OR BETTER PROVIDED) NEW SPRINKLER SYSTEM FINAL INTERIOR FINISH TBD RE: STRUCT. &SPEC.,TYP. GLAZED DOORS: U-0.55(U-0.32 PROVIDEDAT COMMERCIALDOORS,U-0.32 PROVIDEDAT RESI DENTIALDOORS) RE: RCP's FOR DROPPED CEILING LOCATIONS TYPICAL EXTERIOR OVERHANGING BALCONY FLOOR ASSEMBLY FINAL INTERIOR FINISH TBD 4240 Architecture Inc FIXEDFENESTRATION: U-0.36 (U-0.32 PROVIDED) OPERABLEFENESTRATION: U-0.43(U-0.32 PROVIDED) 3/4" STONE TILE&THINSET ON ENTRANCE DOORS: U-0.77(U-0.77 OR BETTER PROVIDED) TYPICAL LEVEL 2 FLOOR ASSEMBLY SLOPED WATERPROOFING ON TYPICAL STONE WALL ASSEMBLY AT CHIMNEYS 43-45 RIVA RIDGE LLC SKYLIGHTS(N/A): U-0.5,SHGC:0.40(N/A) 1 1/2" MORTAR BED WITH RADIANT SNOW MELT ON 950 WINTER ST,#4600 3/4" WOOD FLOORING (TILE IN BATHROOMS) 4" STONE VENEER W/WEEPS AS REQ'D WALTHAM, MA 02451 SHGC PF<0.2: SEW:0.40,N:0.53 1/4" DRAIN BD. ON SHGC 0.2<PF<0.5 SEW:0.48,N:0.58 1-1/8" WARMBOARD-S CONT. WATERPROOF MEMBRANE ON 1/8" DRAINAGE MAT OWNER MT.BELVEDERE 45 LLC SHGC>0.5 SEWN:0.64 2X3 SLEEPERS WITH ACOUSTIC INSULATION ON MORTAR OVER SLIP SHEET(1/8" PER FT. MIN.) ON 2" RIGID POLYISO (R-11.4) OVER WEATHER RESISTIVE BARRIER OVER 950 WINTER ST,#4600 1/8"ACOUSTIC MAT1" MIN. SLOPED POLYISO INSULATION ON DOUBLE WIDTH BRICK WALL WITH 2" INSULATION IN CAVITY(R-10) WALTHAM, MA 02451 30-LB FELT ISOLATION BARRIER 2X6 EXT.T&G EXPOSED FROM UNDERSIDE ON EXISTING CLAY FLUE ARCHITECT 4240 ARCHITECTURE EXISTING 3/4" PLYWOOD SUBFLOOR OR NEW 3/4" PT PLYWOOD EXPOSED REINFORCED PURLINS PER STRUCT. RE: STRUCT. &SPEC.,TYP. 3507 RINGSBY CT.STUITE 117 SUBFLOOR ON EXPOSED BEAMS FINAL INTERIOR FINISH TBD DENVER,CO 80216 EXISTING 2X WOOD JOISTS OR REINFORCED FRAMING PER STRUCT. RE: ELEVATIONS, SECTIONS, RCP'S&STRUCT. (W/R-30 MIN. OVER EXT. SPACE) CIVIL ALPINE ENGINEERING,INC. ENGINEER 34510 HIGHWAY 6 UNIT A-9 EXISTING OR NEW 5/8" GWB CEILING (FIRE SEPARATION AS REQ'D) EDWARDS,CO 81632 EXISTING SPRINKLER SYSTEM LANDSCAPE SHERRY DORWARD ARCHITECT P.O. BOX 3766 VAIL,CO 81658 STRUCTURAL MONROE NEWELL ENGINEER 70 BENCHMARK RD.SUITE 204 AVON,CO 81620 MEP DMCE ENGINEERING ENGINEER 5737 6TH AVE. LAKEWOOD,CO 80214 INTERIORS ASSOCIATES III INTERIOR DESIGN 1516 BLAKE STREET DENVER,CO 80202 TYPICAL ROOF ASSEMBLY Z O 0 © O 41:178 STRUYA 000 0 0 0 0 16 41) 18 19 20 0 0 0 . . Q TIE RODS PER �e\ STRUCTURAL,TYP. RE: ROOF PLAN FOR CHIMNEY \'�- I _ _ _ I _ _ _ _ _110'-0" R[f:A670 FOR TYPICAL 4 / CLEARANCE TO ANY TOP OF CHI MNEYCAP \ _ / \ 3 CHIMNEY DETAILS AND NOTE , \ CONSTRUCTION WITHIN 10'-0" EL.138'- 6" o I i �!� I /� TY . \ 0TOP OF EXISTINGPEAK I ■� �\ 7 EL.137'- 3 1/4"DROPPED CEILING, RE: RCP FOR M®_ I �/ `� ` TOP OF CHIMNEY CAPHEIGHTS I :11;11 ■ ■ ■ '" '`%■'■ I �� \ EL.135'- 11" �' �'� ' j -°'� `,% RE:A604 FOR TYPICAL STONE \\ = TYPICAL STONE WALL ASSEMBLY AT CHIMNEYS ■ ■ i i till.% / %jf® 'I 1 `4- A TACHMENT DETAI SEVA Ce 2" POLYISO INSULATION OVERI ■ ■I ■ ■ � �■II'�'�"�'�J■ � �� `,% 1/ : ®I - -i i - Lr) N WEATHER RESISTIVE AIR I �'� °' _ _ _ \ TOP OF EXISTINGPEAK W LU O i I 11111 - © BARRIER,TYP. I ■ ■ ■ ■ 11111 II �� EL.132'- 4 3/8" N EXPOSED ROOF STRUCTURE IN a NI Win YOGA STUDIO I YOGA YOGA STUDIO . ■ ■ ■ EXTEND EXISTING MASONRY CHIMNEY ~ O (. CEILING OF BEDROOM I i : ION BALCONY STUDIO BALCONY0 11 o co TYPICAL LEVEL 3 FLOOR ASSEMBLY 332 308 332 TO MIN. HEIGHT NEEDED TO MEET = w O O � i CODE REQUIREMENTS, RE: O Q � ■ ■ ■ ■ - STRUCTURAL FOR SUPPORT O Lr I : : I I. I M_ 1 I TYPICAL STONE WALL ASSEMBLY AT CHIMNEYS EXTEND EXISTING CHIMNEY TO : : !!! !___ �� ��'MIN. HEIGHT REQUIRED TO ■ ■ ��� ��� 2" POLYISO INSULATION OVER NMEET CODE REQUIREMENTS, RE: ■ . ■ . - � `�� O - I � � ��� . T ��� �� �� �� -- �� Ir.- 1 WEATHER RESISTIVE AIR BARRIER, � pp I ® �� TYP. M J M G. STRUCTURAL FOR SUPPORT ■ ■ ,■ ■ ■ ■ ■ ■ ■ ■ ■ � ■ ■ ' itigi ' ' ME NEW STONE VENEER AT INTERIOR AND ilm 1 �! 1 I II _ I ®® _ L3 FINISHFLOOR M EXTERIOR OF FIREPLACE&CHIMNEY �" 1� �, _ ------ - ----® - - --------�_■ "" � I % EL.124'- 2" 11 II i■p■I� IIII' ' ■- h ii ��os •I ■ MAINTAIN ALL REQ'D CLEARANCES TO A TOP OF[XI STI NGPEAK _ ,�■ , ! III1i: IjiI� I = ,i �_ -� - EL.122'- 8" IIII� III1�IIIIIIIIIIIII COMBUSTIBLES EXISTING DAMPER TO RERPEC© REQUIREMENTS AT GAS LOG SET11 FIREPLACE � 11*1 0 1 1 I' 1 11111.1111 � - EXISTING DAMPER TO REMAIN AT■' I iili) �' l\II II =II II II 1 Illi -" EXISTING WOOD BURNING FIREPLACE li ,= EXISTING FIREBOX OPENING ILJI +1 MAIII AIN EXIST. BRICK : \ I ' TYPICAL STUCCO WALL ASSEMBLY WITH NEW GAS LOG SET MI"'1 ANTEL AT INTERIOR■ - I 1 \ EXISTING WOOD BURNING FIREPLACE, 414" THICK, 2'-5" WIDE STONE 'll \ 0 il‘ 1 � ' ®_ ■ ■. I • , Tr,�i' lij��.' 1�1 NO CHANGE TO OPENING, OPTIONAL HEARTH BELOW RAISED ! ® BEDROOM 2 ► .T :A ■ '1 I ■ - �' ■ �i 'I STONE VENEER AT INT. SHALLOW HEARTH41A 211 1121° r / _ TYP. EXT. BALCONY FLOOR ASSEMBLY OVER HEATED SPACE A RE:A604 FOR TYPICAL STONEIII ■ LI- IG IF ■ I FULI�jIBUILT- �7_ illjildi= TYPICAL LEVEL 2 FLOOR ASSEMBLY ATTACHMENT DETAILS 1114111 1 0 1 10 0 0 0 = I 0 - lill111` \ ■ o o L2 FINISHFLOOR WMIllnipip. I 111 11117111121_ �-i 10 - o e ' EL.109'- 9" TYP. EXT. OVERHANGING BALCONY FLOOR ASSEMBLY 111111 ' IM■■I 0 �I II II-1 ■1■1_ iil■■ � �___�m!! _ -■ !- -- - �__:_, !1 I4 ■I■I I L2 TOP OF PLYWOOD Ill I ' I � . ■®���11�1���_� _ - _ _ ' ,�� =1=11111=11.1 1111 ==='11111=2 1 :i.lk _ 1 ■i 1111111 I EL.109'- 4 5/8„ P I I I � �"�C� �1�1►.,► - --'s.PI III TENANTiIllilliv NEWFIREBRICKINBASE, 1/4" IIISPACE ! IliBELOWFINISHFLOORI ' �; 151 e,;