Loading...
HomeMy WebLinkAboutPEC17-0010_A253_1508779455.pdf .,„_....„00,,,4„ , ,e.,, BUILDING SECTION NOTES BUILDING SECTION ASSEMBLIES BUILDING SECTION ASSEMBLIES TOWN OFVAIL USE 1. COORDINATE NEW WORK WITH DEMOLITION PLANS. TYPICAL ROOF ASSEMBLY TYPICAL WOOD SIDING WALL ASSEMBLY (LEVEL 2 & 3) g0)113 TYPICAL LEVEL 1 FLOOR ASSEMBLY TYPICAL STONE VENEER WALL ASSEMBLY 2. RE:STRUC.FOR NEW COLUMN LOCATIONS,REINFORCED COLUMNS&BEAMS,AND FLOOR&CEILING PENETRATIONS. PEC 3. RE:MEP FOR DUCT&VENT LOCATIONS COPPER ROOF SHINGLE PANELS STAINED RUSTIC WOOD LAP SIDING WITH LIVE EDGE OVER APPROVED 4. VERIFY EXISTING DIMENSIONS&CONSTRUCTION ASSEMBLIESPRIOR TO PROCEEDING WITH WORK. EXISTING FLOOR FINISH OVER 4" STONE VENEER W/WEEPS AS REQ'D 5/22/201712:00:00AM W/ COPPER CLEATS OVER EXISTING PLYWOOD SUBFLOOR 30# BLDG. PAPER ON 1/8" DRAINAGE MAT 5. FINAL EXTERIOR INSULATION R-VALUEAND THICKNESS DEPENDENT ON LOCATION. 30 LB. ROOFING FELT OVER (HIGH-HEAT) OVER EXISTING 2X WOOD JOIST 3/4" EXT. PLYWOOD SHEATHING (R-0.8) OVER 2" RIGID POLYISO (R-11.4) OVER WEATHER RESISTIVE BARRIER OVER 6. MAINTAIN ALL REQUIRED FIRE RATEDASSEMBLIES. ICE & WATER SHIELD UNDERLAYMENT OVER EXISTING GWB CEILING 1/8" DRAINAGE MAT OVER 5/8" EXT PLYWOOD SHEATHING (R-0.6) ON 7. PROVIDE ACOUSTIC ISOLATION BETWEEN RESIDENCE&TENANT SPACE WHEREVERPOSSIBLE. ATLAS-ACFOAM 4-1/2" NAILBASE, EXISTING SPRINKLER SYSTEM 2" TYP. (R-11.4) RIGID POLYISO INSULATION OVER 8. INTERIOR FINISHES TBD. 2X6 EXISTING or NEW STUD WALL PER STRL. WITH CLOSED CELL 9. SEE ELEVATIONS FOR WALL FINISHES. INSULATION (ASSUME TOTAL R-VALUE=24.2) OVER WEATHER RESISTIVE BARRIER OVER SPRAY INSULATION (R-33) 4-1/2" POLYISO INSULATION (ASSUME Total R-VALUE =26.8) OVER 5/8" EXT. PLYWOOD SHEATHING (R-0.6) ON or SELF-ADHERING MEMBRANE AIR/VAPOR BARRIER OVER TYPICAL BASEMENT LEVEL FLOOR ASSEMBLY 2X6 EXISTING or NEW STUD WALL PER STRL. WITH CLOSED-CELL DOUBLE WIDTH BRICK WALL WITH 2" INSULATION IN CAVITY (R-10) EXISTING CONSTRUCTION TO REMAIN: NO WORK 1/2" PLYWOOD PER STRUCTURAL OVER, (ASSUME TOTAL SPRAY INSULATION (R-33) 5/8" G.W.B. (R-0.6), IN THESE AREAS EXCEPT AS OTHERWISE REQ'D R-VALUE=0.62) OVER EXISTING FLOOR FINISH OVER 5/8" G.W.B.• RE: STRUCT. & SPEC.,TYP. IN DRAWINGS & SPECIFICATIONS. T&G DOUG-FIR ROOF DECKING, (ASSUME TOTAL R-VALUE=3), RE: SPEC. EXISTING CONCRETE SLAB RE: STRUCT. & SPEC.,TYP. FINAL INTERIOR FINISH TBD OVER FINAL INTERIOR FINISH TBD COPPER BYLIN ROOF ICE MELT SYSTEM AT PERIMETER I I 1 HR RATED ASSEMBLY, RE: SHEET G010 EXPOSED ROOF BEAMS, RAFTERS & PURLINS PER STRL. TYPICAL EXTERIOR BALCONY FLOOR ASSEMBLY OVER HEATED SPACE TYPICAL WOOD FRAME & PANEL SIDING ASSEMBLY TYPICAL STUCCO WALL ASSEMBLY SNOW GUARD PER ROOF PLAN VERIFYALLNEW OR REMODELEDASSEMBLIESCOMPLY WITH 2015 IECC CHAPTER 5 PERSCRIPTIVE APPROACH 3/4" STONE TILE & THINSET ON WOOD FRAME & PANEL SIDING (R-0.8) OVER ±7/8" STUCCO VENEER (R-0.2) OVER TOWN OF VAIL THERMAL CLIMATE ZONE:6B TYPICAL LEVEL 3 FLOOR ASSEMBLY SLOPED WATERPROOFING ON 30# BLDG. PAPER ON 2 LAYERS WATER RESISTANT BARRIER INSULATION VALUES: 1 1/2" MORTAR BED WITH RADIANT SNOW MELT ON 3/4" EXT. PLYWOOD SHEATHING (R-0.8) OVER 5/8" CEMENT BOARD (R-0.3) OVER ROOF: R-49 MIN (R-54 PROVIDED) 3/4" WOOD FLOORING (TILE IN BATHROOMS, WOOD or CARPET IN 1/4" DRAIN BD. ON 1/8" DRAINAGE MAT OVER 2" TO 4" (R-11.4 TO R-41.3) RIGID POLYISO INSULATION OVER WOOD FRAMED WALL: R-13 +R-7.5ci-or-R-20+ R-3.8ci(R-43-74 PROVIDED) BEDROOMS & CLOSETS) CONT. WATERPROOF MEMBRANE ON 2" (R-11.4) RIGID POLYISO INSULATION OVER WEATHER RESISTIVE BARRIER OVER MASS WALL: R-15.2ci (R-22 PROVIDED) 1-1/8" WARMBOARD-S SLOPED MORTAR OVER SLIP SHEET (1/8" PER FT. MIN.) ON WEATHER RESISTIVE BARRIER OVER 5/8" EXT. PLYWOOD SHEATHING BELOW GRADE WALLS: R-10ci (NO NEW BELOW GRADE WALLS ENCLOSING HABITABLESPACE) 11-7/8" BCI'S PER STRUCTURAL 3/4" EXT PLYWOOD SHEATHING ON 5/8" EXT. PLYWOOD SHEATHING (R-0.6) ON 2X6 EXISTING or NEW STUD WALL PER STRL. WITH CLOSED-CELL WOOF FRAMED FLOORS: R-30(R-30 MIN. PROVIDED) 3-1/2" DROPPED FURRING EXISTING 2X WOOD JOISTS OR REINFORCED FRAMING PER STRUCT. 2X6 STUD WALL PER STRL. WITH CLOSED-CELL SPRAY INSULATION SPRAY INSULATION (R-33) HEATED SLAB ON GRADE: R-20 FOR 48"BELOW(R-20 MIN.PROVIDED) 1/2" SOUND BOARD WITH R-30 MIN. SPRAY FOAM INSULATION (R-33) or UNHEATEDS.O.B.: R-15 FOR 24"BELOW 1/2" RESILIENT CHANNEL EXISTING OR NEW 5/8" GWB CEILING (FIRE SEPARATION AS REQ'D) 5/8" G.W.B., DOUBLE WIDTH BRICK WALL WITH 2" INSULATION IN CAVITY (R-10) OPAQUE NONSWINGING DOORS: R-4.75 3/4" WOOD PANELING EXISTING SPRINKLER SYSTEM RE: STRUCT. & SPEC.,TYP. 5/8" G.W.B.(R-0.6), WOOD DOORS: U-0.5(U-0.5 OR BETTER PROVIDED) NEW SPRINKLER SYSTEM FINAL INTERIOR FINISH TBD RE: STRUCT. & SPEC.,TYP. GLAZEDDOORS: U-0.55(U-0.32 PROVIDEDAT COMMERCIAL DOORS,U-0.32 PROVIDEDAT RESIDENTIAL DOORS) RE: RCP's FOR DROPPED CEILING LOCATIONS TYPICAL EXTERIOR OVERHANGING BALCONY FLOOR ASSEMBLY FINAL INTERIOR FINISH TBD 4240 Architecture Inc FIXED FENESTRATION: U-0.36 (U-0.32 PROVIDED) OPERABLEFENESTRATION: U-0.43(U-0.32 PROVIDED) 3/4" STONE TILE & THINSET ON ENTRANCE DOORS: U-0.77 (U-0.77 OR BETTER PROVIDED) TYPICAL LEVEL 2 FLOOR ASSEMBLY SLOPED WATERPROOFING ON TYPICAL STONE WALL ASSEMBLY AT CHIMNEYS 43-45 RIVA RIDGE LLC SKYLIGHTS(N/A): U-0.5,SHGC:0.40(N/A) 1 1/2" MORTAR BED WITH RADIANT SNOW MELT ON 950 WINTER ST,#4600 3/4" WOOD FLOORING (TILE IN BATHROOMS) 4" STONE VENEER W/WEEPS AS REQ'D WALTHAM, MA 02451 SHGC PF<0.2: SEW:0.40,N:0.53 1/4" DRAIN BD. ON SHGC 0.2<PF<0.5 SEW:0.48,N:0.58 1-1/8" WARMBOARD-S CONT. WATERPROOF MEMBRANE ON 1/8" DRAINAGE MAT OWNER MT. BELVEDERE 45 LLC SHGC>0.5 SEWN:0.64 2X3 SLEEPERS WITH ACOUSTIC INSULATION ON MORTAR OVER SLIP SHEET (1/8" PER FT. MIN.) ON 2" RIGID POLYISO (R-11.4) OVER WEATHER RESISTIVE BARRIER OVER 950 WINTER ST,#4600 1/8" ACOUSTIC MAT DOUBLE WIDTH BRICK WALL WITH 2" INSULATION IN CAVITY (R-10) WALTHAM, MA 02451 1" MIN. SLOPED POLYISO INSULATION ON 30-LB FELT ISOLATION BARRIER 2X6 EXT. T&G EXPOSED FROM UNDERSIDE ON EXISTING CLAY FLUE ARCHITECT 4240 ARCHITECTURE EXISTING 3/4" PLYWOOD SUBFLOOR OR NEW 3/4" PT PLYWOOD EXPOSED REINFORCED PURLINS PER STRUCT. RE: STRUCT. & SPEC.,TYP. 3507 RINGSBY CT. STUITE 117 SUBFLOOR ON EXPOSED BEAMS FINAL INTERIOR FINISH TBD DENVER, CO 80216 EXISTING 2X WOOD JOISTS OR REINFORCED FRAMING PER STRUCT. RE: ELEVATIONS, SECTIONS, RCP'S & STRUCT. (W/R-30 MIN. OVER EXT. SPACE) CIVIL ALPINE ENGINEERING,INC. ENGINEER 34510 HIGHWAY 6 UNIT A-9 EXISTING OR NEW 5/8" GWB CEILING (FIRE SEPARATION AS REQ'D) EDWARDS, CO 81632 EXISTING SPRINKLER SYSTEM LANDSCAPE SHERRY DORWARD ARCHITECT P.O. BOX 3766 VAIL, CO 81658 STRUCTURAL MONROE NEWELL ENGINEER 70 BENCHMARK RD. SUITE 204 AVON, CO 81620 MEP DMCE ENGINEERING ENGINEER 5737 6TH AVE. LAKEWOOD, CO 80214 INTERIORS ASSOCIATES III INTERIOR DESIGN 1516 BLAKE STREET DENVER, CO 80202 Z O io M M K K cll CI G G ID O A A A B €111 -"*/ GO O O O © O O © ® O ® © 1T.O.CHIMNEY CAP QEL.140'- 9" \ - I 1 TYPICAL ROOF ASSEMBLY TOP OF EXISTING CHIMNEYEL.±139'- 9" I I I I I I I I I A7o3 I I I I I I I I I I I I I 0 l ] TOP OF EXISTING PEAK y I i( -L L J( Z EL.137'- 3 1/4" 11 / I( C --- LLI T T I / `.: RE: ROOF PLAN FOR SNOW FENCING, .evo TYP. Ds ,..,� 111 IIr - ��I, = w III ,� , , ,.� .:. ��C I( J ��( ( J��ICC 1=:::! IC TOP OF EXISTING PEAK wCC' N 12 3\ c �1II I. =1Uni ��i �1\ \\ 1r J� �/� e. u ( II I 1 �\ EL.132'- 4 3/8" o LL ����( M M �_ 1 I� T Illr I HALL I 1711 I I �����L �� -®�� i� ��� ®=�� 1- - 1 - - L -1:8:w Z Q Lu o l Jl l( Illr ���� I 309 I Ti - p =rill 1 \) ( MI. . . - - �,,.:�?��� ''' �I�I ARETAKER'S �I �� �]� om� I4 ■I� -` �- ; STUDIO \1�:;`.,4410:.:04:,:71_,......., , � �\ m pN■ ■ ■ ,I k11 ,�� 01111 311 I �� 0 .- c__) - • co " I( =( ► 1111 o ■ ■ ■ ■ ■ ■ ��_'O. TYPICAL WOOD SIDING WALL ASSEMBLY co J o � �C • I -! 1 ■ . ' . ' . ' . ' . ' . ' . ' . � oIll I1111111118111114,1_ �t �� I BED I I , \\ I I •, I Q rn L3 FINISH FLOOR (r �\ I� _t 1 ,I ,�_,� PLATFORM ■, \ > co rik _ _ �_ - - - 11 I I I I I I ,� !! ���1 __ �i� !� �t�l�l Iimmili _ " BATHROON \ SHOWERl J/ � ' I I ■■ ■• ■■ ■■ ■■ ���■�� Illeopi � rT . . NICHE TYPICAL LEVEL 3 FLOOR SSEMBLYEL.124'- 2" ( IUB _� - -� A11 Jl I( ► i■� .w!:'��+ � ' _ E ■_r® \1 �� off:. .a® ,,�1 ,lig>®a�e����a,�� ®�- ,A� �: lil - ` �� ,_. I 1 W vir TYPICAL WOOD PANELED WALL ASSEMBLY ■■ ■■-■I■ ■■-■I■-■■ I ■I■- STAIR i ®.► ®�®®;►,,ems '�' _,� -SWI 1C . /�� . .....%. / `, I� ,�, I A700/ BEYOND i 1MEW,1 it II I` • p �1_ : / i = .11,17...4„:4;•,,:V.:4;4` 11111 `'-% C� ®. � I L2.5 FINISH FLOOR n( ;� it ,1' � 417(1h EL.119'- 11" ...... ■ ■■ ■I■ ■■ ■I■ ■■�=■I■��•1 CONDENSING TYPICAL STUCCO WALL ASSEMBLY �r / UNIT SCREEN 1I 1 I Bil I/ SII 'I ■■I I� WALL, RE: MEP 11 I ■ h l27,.\\---..• I .. II STRiI F- I EAST I I i ■. I 111111111 �� 225 11 )/ 1( ��i - DLCO ��� - � ���� 1' DA --- --- Z �� �� o234 ■■ ����� ������ �I �I L� ��I _ 5210 III'Ill1,6"111.111111111111 ©� HALpL ■ �i� �t I = I ��_� A701 FOR DETAILS ■■ • CONT. WOOD SCREEN WALL, RE: A700 & -F II SOC 11 1' - I ,�� I� !I f iu;J( I i( I II■IIIIIaI ( �-_- TYPICAL LEVEL 2 FL00R ASSEMBLY �� O �� 10M.� . .�'�.°.�'�.�'�.�'�.�'�.°.�'�.�'�.�'�.°.�'�.�'�.° )r1 \ �r� � ■ ■ � ° I 111111 ■ HMV -:V ��- L2 FINISH FLOOR 1( II ' o I � 417 ELIOT- 9„ e II J _� -- - - _ =mal�lE .. --_ ���. L2 TOP OF PLYWOOD =� �I �r:� i��i '' iC�� 7� �I �n'i:iil�ll lll�ll'� 1I I A`� ' II - ?'� EL.109'- 4 5/8„ ■ Cii • ilOgrillnliNIPIPIRIPI1 MeV TAIR I 1 I l'll -�I ;I I -II I � I ' .. I I I I I �I ��C i � I [ JP I •• I ��- 1125 !i ==� �C =_ (� `■I I TENANT Z = ■� TYPICAL STONE WALL ASSEMBLYI Il 1 11 ENTRY I SPACE I��="- 1�' II Ctrl E STAIR 101] I 151 I ��; I_-�; BEAM, COLUMN, & FRAMING REINFORCING l �1' 110 _ ��■„ PER STRUCT.(E)1 HR ASSEMBLY ' I TYPICAL LEVEL 1 FLOOR ASSEMBLY -_ - 1( /C )I 1 _ Ill )� I I I �M=�� I STORAGE 1 BETWEEN ENTRY I I 1 I 1 I I I I ���,c - AND RETAIL TO dll ■ Aim. ���. i � of i- I- - - L1 FINISH FLOOR /� �� �/ �� I REMAIN � 417 /3\ L1 ENTRY FINISH FLOOR - _ _ l� �' 'II■ -' ► � EL.100'- 2" EL.100'- 8 1/2" - - - - ■� - - - Mt / ■ - twill i ��i / L1 TOP OF PLYWOOD I I ISI I VI I II -II II -� I F I I + I I I I I I I I 2 ♦` (E)1-HR ASSEMBLY • BETWEEN RESIDENCE STAIR ■E TENANT AND RETAIL TO SPACE REMAIN I I I I I I I I I 051 I I 1 I 1 I I I I I I I I TYPICAL BASEMENT FLOOR ASSEMBLY - - LO TOP OF CONC. 03 FOR CONSTRUCTION 2017-09-07 I I I I I I I I I I I I I I 1 I I I I I I EL.90.- 7 3/4" 01 BUILDING PERMIT ISSUE 2017-07-21 ( ) I II ISS.# DESCRIPTION DATE • ) L PROJECT NO.: 21074.00 BUILDING SECTION 1 PROPOSED BUILDING SECTION A253Zr�- 1/4"