Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PEC17-0010_A254_1508779465.pdf
.,„._.......,..ii,„4,, , ,e., 4 BUILDING SECTION NOTES BUILDING SECTION ASSEMBLIES BUILDING SECTION ASSEMBLIES TOWN OFVAILUSE irc (77.71 iV 1. COORDINATE NEW WORK WITH DEMOLITION PLANS. TYPICAL ROOF ASSEMBLY TYPICAL WOOD SIDING WALL ASSEMBLY (LEVEL 2 &3) Jig0)10 TYPICAL LEVEL 1 FLOOR ASSEMBLY TYPICAL STONE VENEER WALL ASSEMBLY 2. RE:STRUC.FOR NEW COLUMN LOCATIONS,REINFORCED COLUMNS&BEAMS,AND FLOOR&CEILING PENETRATIONS. PEC 3. RE:MEP FOR DUCT&VENT LOCATIONS COPPER ROOF SHINGLE PANELS STAINED RUSTIC WOOD LAP SIDING WITH LIVE EDGE OVER APPROVED 4. VERIFY EXISTING DIMENSIONS&CONSTRUCTION ASSEMBLIES PRIOR TO PROCEEDING WITH WORK. EXISTING FLOOR FINISH OVER 4" STONE VENEER W/WEEPS AS REQ'D 5/22/201712:00:00AM W/ COPPER CLEATS OVER EXISTING PLYWOOD SUBFLOOR 30#BLDG. PAPER ON 1/8" DRAINAGE MAT 5. FINAL EXTERIORINSULATION R-VALUEAND THICKNESS DEPENDENT ON LOCATION. 30 LB. ROOFING FELT OVER (HIGH-HEAT) OVER EXISTING 2X WOOD JOIST 3/4" EXT. PLYWOOD SHEATHING (R-0.8) OVER 2" RIGID POLYISO (R-11.4) OVER WEATHER RESISTIVE BARRIER OVER 6. MAINTAIN ALL REQUIRED FIRE RATEDASSEMBLIES. ICE&WATER SHIELD UNDERLAYMENT OVER EXISTING GWB CEILING 1/8" DRAINAGE MAT OVER 5/8" EXT PLYWOOD SHEATHING (R-0.6) ON 7. PROVIDEACOUSTICISOLATION BETWEEN RESIDENCE&TENANT SPACE WHEREVERPOSSIBLE. ATLAS-ACFOAM 4-1/2" NAILBASE, EXISTING SPRINKLER SYSTEM 2"TYP. (R-11.4) RIGID POLYISO INSULATION OVER 8. INTERIOR FINISHES TBD. 2X6 EXISTING or NEW STUD WALL PER STRL. WITH CLOSED-CELL 9. SEE ELEVATIONS FOR WALL FINISHES. INSULATION (ASSUME TOTAL R-VALUE=24.2) OVER WEATHER RESISTIVE BARRIER OVER SPRAY INSULATION (R-33) 4-1/2" POLYISO INSULATION (ASSUME Total R-VALUE =26.8) OVER 5/8" EXT. PLYWOOD SHEATHING (R-0.6) ON or SELF-ADHERING MEMBRANE AIR/VAPOR BARRIER OVER TYPICAL BASEMENT LEVEL FLOOR ASSEMBLY 2X6 EXISTING or NEW STUD WALL PER STRL. WITH CLOSED-CELL DOUBLE WIDTH BRICK WALL WITH 2" INSULATION IN CAVITY(R-10) EXISTING CONSTRUCTION TO REMAIN; NO WORK 1/2" PLYWOOD PER STRUCTURAL OVER, (ASSUME TOTAL SPRAY INSULATION (R-33) 5/8" G.W.B. (R-0.6), I IN THESE AREAS EXCEPT AS OTHERWISE REQ'D R-VALUE=0.62) OVER EXISTING FLOOR FINISH OVER 5/8" G.W.B., RE: STRUCT. &SPEC.,TYP. IN DRAWINGS&SPECIFICATIONS. T&G DOUG-FIR ROOF DECKING, (ASSUME TOTAL R-VALUE=3), RE: SPEC. EXISTING CONCRETE SLAB RE: STRUCT. &SPEC.,TYP. FINAL INTERIOR FINISH TBD A OVER FINAL INTERIOR FINISH TBD COPPER BYLIN ROOF ICE MELT SYSTEM AT PERIMETER Of CO j 0 1 HR RATED ASSEMBLY, RE: SHEET G010 EXPOSED ROOF BEAMS, RAFTERS &PURLINS PER STRL. TYPICAL EXTERIOR BALCONY FLOOR ASSEMBLY OVER HEATED SPACE TYPICAL WOOD FRAME & PANEL SIDING ASSEMBLY TYPICAL STUCCO WALL ASSEMBLY .. SNOW GUARD PER ROOF PLAN 11)..„, VERIFY ALL NEW OR REMODELED ASSEMBLIES COMPLY WITH 2015 IECC CHAPTER5 PERSCRIPTIVEAPPROACH 3/4" STONE TILE&THINSET ON WOOD FRAME& PANEL SIDING (R-O.8) OVER ±7/8" STUCCO VENEER (R-0.2) OVER jQ D° IAN O TOWN OFVAIL THERMALCLIMATEZONE:6B TYPICAL LEVEL 3 FLOOR ASSEMBLY SLOPED WATERPROOFING ON 30#BLDG. PAPER ON 2 LAYERS WATER RESISTANT BARRIER 0 �� �A _ INSULATION VALUES: 1 1/2" MORTAR BED WITH RADIANT SNOW MELT ON 3/4" EXT. PLYWOOD SHEATHING (R-0.8) OVER 5/8" CEMENT BOARD (R-O.3) OVER BIEKER ROOF: R-49 MIN (R-54 PROVIDED) 3/4" WOOD FLOORING (TILE IN BATHROOMS,WOOD or CARPET IN 1/4" DRAIN BD. ON 1/8" DRAINAGE MAT OVER 2"TO 4" (R-11.4 TO R-41.3) RIGID POLYISO INSULATION OVER ' i1�404 _ WOOD FRAMED WALL: R-13 +R-7.5ci -or-R-20 +R-3.8ci (R-43-74 PROVIDED) BEDROOMS&CLOSETS) CONT. WATERPROOF MEMBRANE ON 2" (R-11.4) RIGID POLYISO INSULATION OVER WEATHER RESISTIVE BARRIER OVER �� Y `. AI �V MASS WALL: R-15.2ci (R-22 PROVIDED) 1-1/8" WARMBOARD-S SLOPED MORTAR OVER SLIP SHEET(1/8" PER FT. MIN.) ON WEATHER RESISTIVE BARRIER OVER 5/8" EXT. PLYWOOD SHEATHING ,t, ctiy �� BELOW GRADE WALLS: R-10ci (NO NEW BELOW GRADE WALLS ENCLOSING HABITABLESPACE) 11-7/8" BCI'S PER STRUCTURAL 3/4" EXT PLYWOOD SHEATHING ON 5/8" EXT. PLYWOOD SHEATHING (R-0.6) ON 2X6 EXISTING or NEW STUD WALL PER STRL. WITH CLOSED-CELL • A9S' WOOF FRAMED FLOORS: R-30 (R-30 MIN. PROVIDED) 3-1/2" DROPPED FURRING EXISTING 2X WOOD JOISTS OR REINFORCED FRAMING PER STRUCT. 2X6 STUD WALL PER STRL. WITH CLOSED-CELL SPRAY INSULATION SPRAY INSULATION (R-33) HEATED SLAB ON GRADE: R-20 FOR 48"BELOW(R-20 MIN. PROVIDED) 1/2" SOUND BOARD WITH R-30 MIN. SPRAY FOAM INSULATION (R-33) or UNHEATED S.O.B.: R-15 FOR 24" BELOW 1/2" RESILIENT CHANNEL EXISTING OR NEW 5/8" GWB CEILING (FIRE SEPARATION AS REQ'D) 5/8" G.W.B., DOUBLE WIDTH BRICK WALL WITH 2" INSULATION IN CAVITY(R-10) OPAQUE NONSWINGING DOORS: R-4.75 3/4" WOOD PANELING EXISTING SPRINKLER SYSTEM RE: STRUCT. &SPEC.,TYP. 5/8" G.W.B.(R-0.6), WOOD DOORS: U-0.5 (U-0.5 OR BETTERPROVIDED) NEW SPRINKLER SYSTEM FINAL INTERIOR FINISH TBD RE: STRUCT. &SPEC.,TYP. GLAZED DOORS: U-0.55 (U-0.32 PROVIDED AT COMMERCIALDOORS,U-0.32 PROVIDEDAT RESIDENTIALDOORS) RE: RCP's FOR DROPPED CEILING LOCATIONS TYPICAL EXTERIOR OVERHANGING BALCONY FLOOR ASSEMBLY FINAL INTERIOR FINISH TBD 4240 Architecture Inc FIXED FENESTRATION: U-0.36 (U-0.32 PROVIDED) OPERABLEFENESTRATION: U-O.43 (U-0.32 PROVIDED) 3/4" STONE TILE&THINSET ON ENTRANCEDOORS: U-0.77 (U-0.77 OR BETTERPROVIDED) TYPICAL LEVEL 2 FLOOR ASSEMBLY SLOPED WATERPROOFING ON TYPICAL STONE WALL ASSEMBLY AT CHIMNEYS 43-45 RIVA RIDGE LLC SKYLIGHTS(N/A): U-0.5, SHGC:0.40(N/A) 1 1/2" MORTAR BED WITH RADIANT SNOW MELT ON 950 WINTER ST,#4600 3/4" WOOD FLOORING (TILE IN BATHROOMS) 4" STONE VENEER W/WEEPS AS REQ'D WALTHAM, MA 02451 SHGC PF<0.2: SEW:0.40, N:0.53 1/4" DRAIN BD. ON SHGC 0.2 <PF<0.5 SEW:0.48, N:0.58 1-1/8" WARMBOARD-S CONT. WATERPROOF MEMBRANE ON 1/8" DRAINAGE MAT OWNER MT.BELVEDERE 45 LLC SHGC>0.5 SEWN:0.64 2X3 SLEEPERS WITH ACOUSTIC INSULATION ON MORTAR OVER SLIP SHEET(1/8" PER FT. MIN.) ON 2" RIGID POLYISO (R-11.4) OVER WEATHER RESISTIVE BARRIER OVER 950 WINTER ST,#4600 1/8"ACOUSTIC MATDOUBLE WIDTH BRICK WALL WITH 2" INSULATION IN CAVITY(R-10) WALTHAM, MA 02451 1" MIN. SLOPED POLYISO INSULATION ON 30-LB FELT ISOLATION BARRIER 2X6 EXT.T&G EXPOSED FROM UNDERSIDE ON EXISTING CLAY FLUE ARCHITECT 4240 ARCHITECTURE EXISTING 3/4" PLYWOOD SUBFLOOR OR NEW 3/4" PT PLYWOOD EXPOSED REINFORCED PURLINS PER STRUCT. RE: STRUCT. &SPEC.,TYP. 3507 RINGSBY CT.STUITE 117 SUBFLOOR ON EXPOSED BEAMS FINAL INTERIOR FINISH TBD DENVER,CO 80216 EXISTING 2X WOOD JOISTS OR REINFORCED FRAMING PER STRUCT. RE: ELEVATIONS, SECTIONS, RCP'S&STRUCT. CIVIL ALPINE ENGINEERING.INC. (W/R-30 MIN. OVER EXT. SPACE) ENGINEER 34510 HIGHWAY 6 UNIT A-9 EXISTING OR NEW 5/8" GWB CEILING (FIRE SEPARATION AS REQ'D) EDWARDS,CO 81632 EXISTING SPRINKLER SYSTEM LANDSCAPE SHERRY DORWARD ARCHITECT P.O. BOX 3766 VAIL,CO 81658 STRUCTURAL MONROE NEWELL ENGINEER 70 BENCHMARK RD.SUITE 204 AVON,CO 81620 MEP DMCE ENGINEERING ENGINEER 5737 6TH AVE. LAKEWOOD,CO 80214 INTERIORS ASSOCIATES III INTERIOR DESIGN 1516 BLAKE STREET DENVER,CO 80202 Z O TYPICAL ROOF ASSEMBLY EXTEND EXISTING MASONRY CHIMNEY TO MIN. HEIGHT REQUIRED TO MEET CODE REQUIREMENTS, 00000 O O © O O CO 0 C QQ,_ AA Go ® EEA0 0 Ei_.i KK ® RPROVIDE E: STRUCTU RAL FOR SUPPORTRRESTOR T.O. CHIMN9" EY CAP O / EL. 140'- RE: ROOF PLAN FOR LOCATION OF CHIMNEY TO STAIR ROOF 2 \ A703 I MIN.:10.11,� - - - TOP 039 EXISTING CHIM'-NEY W I WAVE 14PAMI TOP OF EXISTING PEAK vic - - - - - - - - - - /\ - _I - - F A C- In EL. 137'- 3 1/4" 10'-0" �/ I ■ LU N so MAINTAIN ALL REQUIRED W _ ism /' � I i CLEARANCES TO COMBUSTIBLES W O CV tet • �:•,,-■ _� / 2" POLYISO INSULATION OVER (� O Lp 1 I iiiii; ��� \, Ill 111 r = - ■ WEATHER RESISTIVE AIR LU Z ■ ==1� ��® ��II imiiii BARRIER,TYP. Z pQ OTOP OF EXISTING PEAK o I' I �' ' I I I !-II I I II I _ _ TOP OF EXISTING PEAK 0 = z 417 EL. 132'- 4 3/8" �'\ � II„ - - - EL. 132'- 4 3/8" �`i4` I k� / ASTER I ' SOUTH O N uii s,- YOGA STUDIO c.��= ��/.. ��I �� I 703 BAl1CONY I HALL I� C I B,TH300V I • : BALCONY O TYPICAL LEVEL 3 FLOOR ASSEMBLY _ • _ .....w..01 , ,,��� �� L III 309 3 302 �� 1 331 M _ o 111 VIIIit414,fta,„_4_ < �� _ _ Q01_ . NTE• �� / ■■ > c� 111 CARETAKER'S IIjIN I ! !1V i111 L3 FINISH FLOOR co WEST BALCONI .���� . -1111 ■ - -_�- �=�1- T - - - TYPICAL EXTERIOR BALCONY ASSEMBLY OVER HEATED SPACE �� III I - - EL. 124'- 2" 333 _� i� Oe �-� I�� ME. . ............11111111111111111111111111111311111111111a- maI� - _ _ _ „ R SPEC 10-32-00 FOR FIREPLACE DOOR �� / \ l I® ■• •• •„ ;; ■• •• 11■� E ■I=,■■■=I=, I &DAMPER REQUIREMENTS AT GAS LOG ° 7 I -e--,�' , 1 SET FIREPLACE PB RR PP111 / Ca11:1. �, I LI M I ijilli!ME I i I �I TYPICAL STONE WALL ASSEMBLY AT CHIMNEYS L2.5 FINISH FLOOR 111 ...IOW. i�-'' / .MMAral mmalli li` `�,,__ i \ EL. 119'- 11" ►�� \ -___I .� 1 = `I� 4" THICK, 2'-9" WIDE STONE IIS .__■■_w_ __ _■■__ TYPICAL WOOD SIDING WALL ASSEMBLY -_I __ _I-�� � ='-- - - - 1�,___. / 1:__■■_��i__�_■■__ 11r HEARTH BELOW RAISED Ch -___I- ___ __III_ , t l t +� --■ --- --■�-- I ■■ limio 4"4 SHALLOW HEARTH TYP. EXT. BALCONY FL. ASSEMBLY OVER HEATED SPACE �,!41 I IE- .��' 1 -i-_ 101 ■■ 1 II MI IF 1 pH pH 1 .7 „ izi 1 M mmm'I� •--' -'I�- ■■ II STAIR / +� .___.. I _..__ ■■ 1 �- t - - SOUTH -___I-v �i. __I-_ ®I ®® ECEPTION ■■ 210 OOM BALCONY 219 `�� N E:mm 611 BIM 209 iiii III 1 ,.. 0 A 231 ■i■ M �_- ___■�_ ITimiono ■ 111 ■■I■ I111 �■ ■ ■moi TYPICAL LEVEL 2 FLOOR ASSEMBLY I I I AllI.1111111 MEM 1 ailli .wes=rm-i I&Tea : N1' Q rikL2 FINISH FLOOR 11111111111 le EL. 109'- 9" •mi °1 1111n1�1�1r I_ w__■ Miliejl ME / �._. , ..._,-- L2 TOP OF PLYWOOD Ii=11= II EL. 109'- 4 5/8" ____- lippro 1 oih1 ■ VITRINE BEYOND BEAM, COLUMN,&FRAMING REINFORCING PERl 'I 1RY �IMilli knumya SPACE -�' STRUCTURAL,TYP. • / II I I I I I IIIL I. 1 I 1 MII L \ viri J TYPICAL LEVEL 1 FLOOR ASSEMBLY II' ► , L1 FINISH FLOOR I Off- --- -----_ ; EL. 100'- 2,. . ■� II� flu w■ - - - / LI TOP OF PLYWOOD 4 EL. 100- 0 I I ' 1 Il • TENANT 04 PERMIT REVISIONS 2017-09-22 SPACE 03 FOR CONSTRUCTION 2017-09-07 I I I I 051 I I 02 PERMIT REVISIONS 2017-08-25 01 BUILDING PERMIT ISSUE 2017-07-21 TYPICAL BASEMENT FLOOR ASSEMBLY ISS.# DESCRIPTION DATE I - - LO TOP OF CONC. EL.90'- 7 3/4" PROJECT NO.: 21074.00 I I I I I I I I I I I I I I I I I I I I I I MM BUILDING SECTION 1 BUILDING SECTION '-O"