Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PEC17-0010_A255_1508779460.pdf
.,„..........00„4, „a.,, z 4 BUILDING SECTION NOTES BUILDING SECTION ASSEMBLIES BUILDING SECTION ASSEMBLIES TOWN OF VAIL USE 13 1. COORDINATENEW WORKWITH DEMOLITION PLANS. TYPICAL ROOF ASSEMBLY TYPICAL WOOD SIDING WALL ASSEMBLY (LEVEL 2 & 3) Jig 1 TYPICAL LEVEL 1 FLOOR ASSEMBLY TYPICAL STONE VENEER WALL ASSEMBLY 2. RE:STRUC.FOR NEW COLUMN LOCATIONS,R EINFOR CEDCOLUMNS&BEAMS,AND FLOOR&CEILING PENETRATIONS. PEC 3. RE:MEP FOR DUCT&VENT LOCATIONS COPPER ROOF SHINGLE PANELS STAINED RUSTIC WOOD LAP SIDING WITH LIVE EDGE OVER APPROVED 4. VERIFY EXISTING DIMENSIONS&CONSTRUCTION ASSEMBLIES PR IORTO PROCEEDING WITH WORK. EXISTING FLOOR FINISH OVER 4" STONE VENEER W/WEEPS AS REQ'D 5/22/201712:00:00AM W/ COPPER CLEATS OVER EXISTING PLYWOOD SUBFLOOR 301t BLDG. PAPER ON 1/8" DRAINAGE MAT 5. FINALEXTERIORINSULATION R-VALUEANDTHICKNESSDEPENDENTON LOCATION. 30 LB. ROOFING FELT OVER (HIGH-HEAT) OVER EXISTING 2X WOOD JOIST 3/4" EXT. PLYWOOD SHEATHING (R-O.8) OVER 2" RIGID POLYISO (R-11.4) OVER WEATHER RESISTIVE BARRIER OVER 6. MAINTAIN ALLREQUIREDFIRERATED ASSEMBLIES. ICE & WATER SHIELD UNDERLAYMENT OVER EXISTING GWB CEILING 1/8" DRAINAGE MAT OVER 5/8" EXT PLYWOOD SHEATHING (R-0.6) ON 7. PROVIDEACOUSTICISOLATIONBETWEENRESIDENCE&TENANTSPACEWHEREVERPOSSIBLE. ATLAS-ACFOAM 4-1/2" NAILBASE, EXISTING SPRINKLER SYSTEM 2" TYP. (R-11.4) RIGID POLYISO INSULATION OVER 8. INTER IORFINISHES TBD. 2X6 EXISTING or NEW STUD WALL PER STR L. WITH CLOSED CELL 9. SEE ELEVATIONS FOR WALL FINISHES. INSULATION (ASSUME TOTAL R-VALUE=24.2) OVER WEATHER RESISTIVE BARRIER OVER SPRAY INSULATION (R-33) 4-1/2" POLYISO INSULATION (ASSUME Total R-VALUE =26.8) OVER 5/8" EXT. PLYWOOD SHEATHING (R-0.6) ON or SELF-ADHERING MEMBRANE AIR/VAPOR BARRIER OVER TYPICAL BASEMENT LEVEL FLOOR ASSEMBLY 2X6 EXISTING or NEW STUD WALL PER STRL. WITH CLOSED-CELL DOUBLE WIDTH BRICK WALL WITH 2" INSULATION IN CAVITY (R-10) EXISTING CONSTRUCTION TO REMAIN; NO WORK 1/2" PLYWOOD PER STRUCTURAL OVER, (ASSUME TOTAL SPRAY INSULATION (R-33) 5/8" G.W.B. (R-0.6), IN THESE AREAS EXCEPT AS OTHERWISE REQ'D R-VALUE=0.62) OVER EXISTING FLOOR FINISH OVER 5/8" G.W.B.• RE: STRUCT. & SPEC., TYP. IN DRAWINGS & SPECIFICATIONS. T&G DOUG-FIR ROOF DECKING, (ASSUME TOTAL R-VALUE=3), RE:SPEC. EXISTING CONCRETE SLAB RE: STRUCT. & SPEC., TYP. FINAL INTERIOR FINISH TBD Q OVER FINAL INTERIOR FINISH TBD COPPER BYLIN ROOF ICE MELT SYSTEM AT PERIMETER 1 HR RATED ASSEMBLY, RE:SHEET G010 EXPOSED ROOF BEAMS, RAFTERS & PUR LINS PER STR L. TYPICAL EXTERIOR BALCONY FLOOR ASSEMBLY OVER HEATED SPACE TYPICAL WOOD FRAME & PANEL SIDING ASSEMBLY TYPICAL STUCCO WALL ASSEMBLY SNOW GUARD PER ROOF PLAN VERIFY ALL NEW OR REMODELED ASSEMBLIES COMPLY WITH 2015 IECC CHAPTER5 PER SCR IPTIVEAPPROACH 3/4" STONE TILE & THINSET ON WOOD FRAME & PANEL SIDING (R-0.8) OVER ±7/8" STUCCO VENEER (R-0.2) OVER TOWN OF VAIL THERMALCLIMATEZONE:6B TYPICAL LEVEL 3 FLOOR ASSEMBLY SLOPED WATERPROOFING ON 30# BLDG. PAPER ON 2 LAYERS WATER RESISTANT BARRIER INSULATION VALUES: 1 1/2" MORTAR BED WITH RADIANT SNOW MELT ON 3/4" EXT. PLYWOOD SHEATHING (R-0.8) OVER 5/8" CEMENT BOARD (R-0.3) OVER ROOF: R-49 MIN (R-54 PROVIDED) 3/4" WOOD FLOORING (TILE IN BATHROOMS, WOOD or CAR PET IN 1/4" DRAIN BD. ON 1/8" DRAINAGE MAT OVER 2" TO 4" (R-11.4 TO R-41.3) RIGID POLYISO INSULATION OVER WOOD FRAMED WALL: R-13+ R-7.5ci-or-R-20+ R-3.8ci(R-43-74 PROVIDED) BEDROOMS & CLOSETS) CONT. WATERPROOF MEMBRANE ON 2" (R-11.4) RIGID POLYISO INSULATION OVER WEATHER RESISTIVE BARRIER OVER MASS WALL: R-15.2ci(R-22 PROVIDED) 1-1/8" WARMBOARD-S SLOPED MORTAR OVER SLIP SHEET (1/8" PER FT. MIN.) ON WEATHER RESISTIVE BARRIER OVER 5/8" EXT. PLYWOOD SHEATHING BELOW GRADEWALLS: R-10ci(NO NEW BELOW GRADEWALLS ENCLOSING HABITABLESPACE) 11-7/8" BCI'S PER STRUCTURAL 3/4" EXT PLYWOOD SHEATHING ON 5/8" EXT. PLYWOOD SHEATHING (R-0.6) ON 2X6 EXISTING or NEW STUD WALL PER STRL. WITH CLOSED-CELL WOOF FRAMED FLOORS: R-30(R-30 MIN. PROVIDED) 3-1/2" DROPPED FURRING EXISTING 2X WOOD JOISTS OR REINFORCED FRAMING PER STRUCT. 2X6 STUD WALL PER STRL. WITH CLOSED-CELL SPRAY INSULATION SPRAY INSULATION (R-33) HEATED SLAB ON GRADE: R-20 FOR 48" BELOW(R-20 MIN. PROVIDED) 1/2" SOUND BOARD WITH R-30 MIN. SPRAY FOAM INSULATION (R-33) or UNHEATED S.O.B.: R-15 FOR 24" BELOW 1/2" RESILIENT CHANNEL EXISTING OR NEW 5/8" GWB CEILING (FIRE SEPARATION AS REQ'D) 5/8" G.W.B., DOUBLE WIDTH BRICK WALL WITH 2" INSULATION IN CAVITY (R-10) OPAQUE NONSWINGING DOORS: R-4.75 3/4" WOOD PANELING EXISTING SPRINKLER SYSTEM RE: STRUCT. & SPEC., TYP. 5/8" G.W.B.(R-0.6), WOOD DOORS: U-0.5(U-0.5 OR BETTERPROVIDED) NEW SPRINKLER SYSTEM FINAL INTERIOR FINISH TBD RE: STRUCT. & SPEC., TYP. GLAZEDDOORS: U-0.55(U-0.32 PROVIDED ATCOMMERCIALDOOR5,U-0.32 PROVIDED AT R ESIDENTIALDOOR S) RE: RCP's FOR DROPPED CEILING LOCATIONS TYPICAL EXTER IOR OVERHANGING BALCONY FLOOR ASSEMBLY FINAL INTERIOR FINISH TBD 4240 Architecture Inc FIXED FENESTRATION: U-0.36(U-0.32 PROVIDED) OPERABLEFENESTRATION: U-0.43 (U-0.32 PROVIDED) 3/4" STONE TILE & THINSET ON ENTRANCEDOORS: U-0.77 (U-0.77 OR BETTERPROVIDED) TYPICAL LEVEL 2 FLOOR ASSEMBLY SLOPED WATERPROOFING ON TYPICAL STONE WALL ASSEMBLY AT CHIMNEYS 43-45 RIVA RIDGE LLC 954600 SKYLIGHTS(N/A): U-0.5, SHGC: 0.40 (N/A) 1 1/2" MORTAR BED WITH RADIANT SNOW MELT ON WALTHAM,0 WINTERAST, 451 3/4" WOOD FLOORING (TILE IN BATHROOMS) 4" STONE VENEER W/WEEPS AS REQ'D MA 02451 SHGC PF<0.2: SEW:0.40, N:0.53 1/4" DRAIN BD. ON SHGC 0.2 <PF<0.5 SEW:0.48, N:0.58 1-1/8" WARMBOARD-S CONT. WATERPROOF MEMBRANE ON 1/8" DRAINAGE MAT OWNER MT. BELVEDERE 45 LLC SHGC>0.5 SEWN:0.64 2X3 SLEEPERS WITH ACOUSTIC INSULATION ON MORTAR OVER SLIP SHEET (1/8" PER FT. MIN.) ON 2" RIGID POLYISO (R-11.4) OVER WEATHER RESISTIVE BARRIER OVER 950 WINTER ST, *4600 1/8" ACOUSTIC MATDOUBLE WIDTH BRICK WALL WITH 2" INSULATION IN CAVITY (R-10) WALTHAM, MA 02451 1" MIN. SLOPED POLYISO INSULATION ON 30-LB FELT ISOLATION BARRIER 2X6 EXT. T&G EXPOSED FROM UNDERSIDE ON EXISTING CLAY FLUE ARCHITECT 4240 ARCHITECTURE EXISTING 3/4" PLYWOOD SUBFLOOR OR NEW 3/4" PT PLYWOOD EXPOSED REINFORCED PURLINS PER STRUCT. RE: STRUCT. & SPEC., TYP. 3507 RINGSBY CT. STUITE 117 SUBFLOOR ON EXPOSED BEAMS FINAL INTERIOR FINISH TBD DENVER, CO 80216 EXISTING 2X WOOD JOISTS OR REINFORCED FRAMING PER STRUCT. RE: ELEVATIONS, SECTIONS, RCP'S & STRUCT. (W/R-30 MIN. OVER EXT. SPACE) CIVIL ALPINE ENGINEERING, INC. ENGINEER 34510 HIGHWAY 6 UNIT A-9 EXISTING OR NEW 5/8" GWB CEILING (FIRE SEPARATION AS REQ'D) EDWARDS, CO 81632 EXISTING SPRINKLER SYSTEM LANDSCAPE SHERRY DORWARD ARCHITECT P.O. BOX 3766 VAIL, CO 81658 STRUCTURAL MONROE NEWELL ENGINEER 70 BENCHMARK RD.SUITE 204 AVON, CO 81620 MEP DMCE ENGINEERING ENGINEER 5737 6TH AVE. LAKEWOOD, CO 80214 INTERIORS ASSOCIATES III INTERIOR DESIGN 1516 BLAKE STREET DENVER, CO 80202 TYPICAL ROOF ASSEMBLY 0 Q 0 ® mCIEEA AA A B D GI m II © ® O CI CI III 0 © ® O 0 RE: MEP FOR VENT REQUIREMENT, RE: 1/A250 FOR LOCATION & NOTES, COORDINATE WITH INTERIORS SAUNA EQUIP. PER MEP LL' Ce lii -I - -T- _ TOP OF EXISTING PEAK W �n c� EL. 137'- 3 1/4" w N 1 if I 17 j III -III II I I) N o RE: STRUCTURAL FOR LOWERED CSD • \ I ��I A l_ Z C_� / I� ISI L - - - .- N.1 Ii II I■ Q SHALLOW DECK BEAMS 1 J��LI ( - - - _ ' _ ( J1� RE: STRUCT. FOR SHALLOW FRAMING Cl = Z - _ •• ���� Jam_ O = v RI f J. - O mom L. gym\ 1 N NI►=1 - u ( 1, ,m / 1, 11 .- L.) - TYPICAL LEVEL 3 FLOOR ASSEMBLY I I' II I IMASTER MASTER I I IA YOgA I ���� I �� I I I I I I I c J M -BEDROOM CLOSETII STU IC I [ �'/ ( if �� Q 0 A70 I ' 301 304 �f �J TYPICAL EXT. BALCONY ASSEMBLY OVER HEATED SPACE 4 , > M -- D=11 _ 0 0 AINE�_� L3 FINISH FLOOR I'iItIl.Ii 1' M�_��-_I _ • _- II _ -Ii � ��l l� • 1iUUU• • iiEiTS USUT, !�y � ��'w.iUSU %�\ RE: INTERIORS FOR FINISHES,TYP. ''���'''`1 I '' RE: ROOF PLAN FOR SNOW FENCING ���` I �♦ I OUT SWING WINDOW FOR SHELF PER INT. ( I I�, ® ® I I I il '-- - MEM -.1 I '„: _ :1111_ _tiri,;;A____ ♦e I > ti. : -ED TYPICAL LEVEL 2 FLOOR ASSEMBLY �i.. ,M ; 1 _ ,�,,I�, pl 1 1 , 11 11 HALL ��� I BEDROOM �'��' I. ��� s� ���� iiiiii SOUTH �� �im I I� ��I��. CLOSET HALL u I I I I I I LIVING AIM �� BALCONY 213 11?ihI in NORTHWEST YPICAL WOOD SIDING WALL ASSEMBLY (LEVEL 2 & 3) 11 •' KITCH: N *AIRY/RY/ 1 1 BALCONY TYPICAL BALCONY FLOOR ASSEMBLY OVER HEATED SPACE 231 C� 7 1 203 o. o o 233 ns�o/ - ���■ 1IE �.m IIII �Los;r YPICAL EXT. BALCONY ASSEMBLY OVER HEATED SPACE v ,Pr -.RI__ . ., lii�1':ai�l I1._ I =1 0 d O ` it / III o L2 FINISH FLOOR - I EL. 109'- 9" / 1 r ii M IIIIIII i_. NIL -"EMI , - - _ L2 TOP OF PLYWOOD - - - - 1.31111MIII ■' N EL. 109'- 4 5/8" if 2 I I I I I I I I I I I I I I u I V�;W I TENANT SPACE 151 TYPICAL LEVEL 1 FLOOR ASSEMBLYitit= 0 L1 FINISH FLOOR 11-:\ - / EL. 100'- 2" L1 TOP OF PLYWOOD - EL. 100'- 0" I I I I TENANT I SPACE 03 FOR CONSTRUCTION 2017-09-07 051 I 02 PERMIT REVISIONS 2017-08-25 I I I I I I I I I I I I I I 01 BUILDING PERMIT ISSUE 2017-07-21 I ISS.# DESCRIPTION DATE TYPICAL BASEMENT FLOOR ASSEMBLY IPROJECT NO.: 21074.00 EXISTING FLOOR FINISH OVER _ _ LO TOP OF CONC. EXISTING CONCRETE SLAB WV / I I I I I I I I I I I I I ) 1 I EL.90'- 73/4" BUILDING SECTION 1 UILDING SECTION ..77_77_1 1/4" = 1'-O"