Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PEC17-0010_A510_1508779462.pdf
2 3 TOWN OF VAIL USE WINDOW SCHEDULE WINDOW SCHEDULECONTINUED -- o.)"0- PEC SUB NOMINAL SIZE SAFETY DIVIDED SUB NOMINAL SIZE SAFETY DIVIDED 5/22/2017E1D2:OO:OOAM MARK GROUP DESCRIPTION WIDTH HEIGHT HEAD HEIGHT MODEL SHUTTER U FACTOR GLAZING LITES REMARKS MARK GROUP DESCRIPTION WIDTH HEIGHT HEAD HEIGHT MODEL SHUTTER U FACTOR GLAZING LITES REMARKS TENANT RESIDENTIAL T101 FIX ED GROUPING ±7'-8 3/4" 5' - 6" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY LEVEL 2.5 A FIXED 1' - 10" 1' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY R312 FRENCH CASEMENT 3' - 2" 2' - 6" ±7' - 1 3/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 4 VERIFY R.O. W/HEADER/RAFTERS, ADJ. ROOF & PLATFORM B FIXED 1' - 10" 4' - 2" 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY R313 MIXED GROUPING 5' - 0" ±6' - 6 1/2" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER C FIXED ±3' - 5 3/4" 1' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY A FIX EDTRAPEZOID 2' - 6" ±1' - 91/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER D FIXED ±3' - 5 3/4" 4' - 2" 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY B FIX EDTRAPEZOID 2' - 6" ±2' - 61/2" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER T102 COMBINATION GROUPING EXTERIORVITRINE 6'-4" 5' - 6" ±8' - 2 3/4" SIERRA PACIFIC- ASPEN DESIGNER SASH N/A U-FACTOR 0.22 AT EAST ELEV,S.G. WHERE REQ'D PER GRADE C FRENCH CASEMENT 5' - 0" 3' - 8" 6' - 8" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 8 VERIFY HEIGHT OF PLATFORM A FIXED 1-4 2/3" 1' - 6" ±8' - 2 3/4" SIERRA PACIFIC- ASPEN DESIGNER SASH N/A RE ELEV.FOR QUANTITY R314 FIX EDTRAPEZOID ±6' - 0 3/4" ±3' - 81/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X R.O. DEPENDENT ON RAFTER,& DOORS 311a & 311b B OUTSWING CASEMENT WITH LOCK 4' - 2" 4' - 2" ±6' - 10 3/4" SIERRA PACIFIC- ASPEN DESIGNER SASH N/A X RE ELEV.FOR QUANTITY R315 MIX ED GROUPING 5' - 0" ±6' - 61/2" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER T103 COMBINATION GROUPING AT INTERIOR 6'-4" 5' - 6" ±8' - 2 3/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 INTERIOR STAIR WINDOW A FIXEDTRAPEZOID 2' - 6" ±2' - 61/2" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER A FIXED 1' - 3 3/4" 1' - 2" ±8' - 2 3/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY B FIX ED TRAPEZOID 2' - 6" ±1' - 9 1/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER B FIXED 1' - 3 3/4" 4' - 2" ±6' - 10 3/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY C FRENCH CASEMENT 5' - 0" 3' - 8" 6' - 8" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 8 C FIXED ±3' - 1 3/4" 1' - 2" ±8' - 2 3/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY R316 FRENCH CASEMENT 3' - 2" 4' - 2" ±6' - 1" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 4 VERIFY R.O. WITH HEADER/RAFTERS D OUTSWING CASEMENT WITH LOCK ±3' - 5 3/4" 4' - 2" ±6' - 10 3/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X ACCESS TO VITRINE FROM EXTERIOR R317 FRENCH CASEMENT 3' - 2" 2' - 11" ±6' - 1" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 4 VERIFY R.O. WITH HEADER/RAFTERS T104 FIX ED GROUPING 6'-4" 5' - 6" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY LEVEL 3 A FIXED ±2' - 5 1/2" 1' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY,ALIGN WITH T105 R301 FIXED BUTT GLAZED CORNER GROUPING ±3' - 3 3/4" ±8' - 5 3/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 PART OF WINDOW R325 UNIT, VERIFY WIDTH, SEE PLAN B FIXED ±2' - 5 1/2" 4' - 2" 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY,ALIGN WITH T105 A FIX EDTRIANGLE ±3' - 3 3/4" ±11 3/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 ACTUAL GLAZING IN UNIT T.B.D., R.O. PER RAFTER 2 o Architecture Inc T105 FIX ED GROUPING 6' - 8 3/4" 5' - 6" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON DOUBLE COLUMN SPACING B FIXED ±3' - 3 3/4" 7' - 0" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X PART OF WINDOW R325 UNIT 4 4 A FIXED 1' - 6" 1' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY R302 FIX ED GROUPING 1' - 7 1/2" ±9' - 3" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER 43-45 RIVA RIDGE LLC B FIXED 1' - 6" 4' - 2" 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY A FIX EDTRAPEZOID 1' - 71/2" ±1' - 91/2" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 950 WINTER ST,#4600 WALTHAM,MA 02451 C FIXED ±3' - 1 3/4" 1' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY B FIXED 1' - 71/2" 7' - 0" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X OWNER MT.BELVEDERE 45 LLC D FIXED ±3' - 1 3/4" 4' - 2" 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY R303 FIX EDTRAPEZOID OVER DOOR 6' - 4" ±3' - 91/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X R.O. DEPENDENT ON RAFTER& DOOR 301b BELOW 950 WINTER ST,#4600 T106 FIX ED GROUPING WITH DOOR 1' - 4" 6' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X R.O. DEPENDENT ON DOOR 151g R304 FIX ED GROUPING 1' - 71/2" ±11' - 3 1/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER WALTHAM,MA 02451 T107 CASEMENT or FIX EDTBD 2' - 3" 2' - 91/2" 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 4 HEAD ALIGNMENT WITH T108, OPTIONAL FIX ED,TBD A FIX EDTRAPEZOID 1' - 71/2" ±3' - 91/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 ARCHITECT 3507 RINGS ARCHIY CT.STUITE RINGSBY CT.STUITE 117 T108 FIXED GROUPING WITH DOOR ±4' - 8" 5' - 6" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY B FIXED 1' - 7 1/2" 7' - 0" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X DENVER,CO 80216 A FIXED 1' - 2" 1' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY R305 FIX EDTRAPEZOID OVER DOOR 6' - 4" ±3' - 1 1/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X R.O. DEPENDENT ON RAFTER& DOOR 301c BELOW CIVIL ALPINE ENGINEERING,INC. ENGINEER 34510 HIGHWAY 6 UNIT A-9 B FIXED 1' - 2" 4' - 2" 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY R306 FIXEDGROUPING ±4' - 4" ±8' - 5 3/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER EDWARDS,CO 81632 C FIXED ±2' - 4" 1' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY A FIX EDTRIANGLE ±2' - 8" ±11 3/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 ACTUAL GLAZING IN UNIT T.B.D., R.O. PER RAFTER LANDSCAPE SHERRY DORWARD D FIXED ±2 - 4 4 - 2 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY B FIXED ARCHITECT P.O. BOX 3766 ' _4' - 4" 7' - 0" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X WINDOW R.O. DEPENDENT ON CHIMNEY STONE VAIL,co 81658 T109 FIX ED GROUPING ±9' - 1 1/2" 5' - 6" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY R307 NOT USED STRUCTURAL MONROE NEWELL A FIXED ±2' - 71/4" 1' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY R308 FIXED GROUPING OR SINGLE B PER ELEV. 3' - 11" ±7' - 21/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER ENGINEER 70 BENCHMARK RD.SUITE 204 AVON,CO 81620 B FIXED ±2' - 71/4" 4' - 2" 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY A FIXED 3' - 11" ±1 -7" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEVATIONS FOR LOCATIONS OF SINGLE B MEP DMCE ENGINEERING C FIXED 3' - 4" 1' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY B FIXED 3' - 11" 5' - 1 1/2" 8' - 3 1/2" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 9 ENGINEER 5737 6TH AVE. LAKEWOOD,CO 80214 D FIXED 3' - 4" 4' - 2" 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY R309 FIXED GROUPING 5' - 8" ±8' - 3 1/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER INTERIORS ASSOCIATES III INTERIOR DESIGN T110 FIX ED GROUPING ±6' - 2 3/4" 5' - 6" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY A FIX ED TRAPEZOID 5' - 8" ±2' -7 3/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X TRAPEZOID 1516 BLAKE STREET DENVER,CO 80202 A FIXED 1' - 3" 1' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY B FIXED 2' - 10" 5' - 1 1/2" 8' - 3 1/2" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 6 WINDOW R.O. DEPENDENT ON CHIMNEY STONE B FIXED 1' - 3" 4' - 2" 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY R310 FIXED GROUPING 3' - 11" ±7' - 21/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER C FIXED ±3' - 1 3/4" 1' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY A FIXED 3' - 11" ±1' -7" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER D FIXED ±3' - 1 3/4" 4' - 2" 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY B FIXED 3' - 11" 5' - 1 1/2" 8' - 3 1/2" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 9 T111 FIX ED GROUPING ±4' - 10 3/4" 5' - 6" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY R311 FIXED 3' - 11" ±6' - 81/2" 2' - 6" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 12 AT STAIR LANDING A FIXED 1' - 6" 1' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY R318 FIXED 2' - 6" 7' - 0" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE: ELEV MATCH DOOR 309a, SOLID PANEL AT BASE B FIXED 1' - 6" 4' - 2" 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY R319 FIXEDTRAPEZOID ±4' - 3 1/4" ±2' - 01/4" ±10' - 01/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 2 HEAD HT. PER RAFTER,WIDTH & MUNTINS PER DOOR 308e C FIXED ±3' - 1 1/4" 1' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY R320 FIX ED TRAPEZOID ±8' - 7 1/2" ±3' - 5 1/4" ±11' - 51/4" SIERRA PACIFIC- ASPEN DESIGNER SASH X 0.32 4 HEAD HT. PER RAFTER,WIDTH & MUNTINS PER 308d/308e Z D FIXED ±3' - 1 1/4" 4' - 2" 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY R321 FIX EDTRAPEZOID ±4' - 3 1/4" ±2' - 0 1/4" ±10' - 01/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 2 HEAD HT. PER RAFTER,WIDTH & MUNTINS PER DOOR 308d RESIDENTIAL R322 CASEMENT WITH SHUTTER 2' - 6" 2' - 6" 6' - 6" SIERRA PACIFIC- ASPEN DESIGNER SASH X 0.32 ® SHOWER RE ELEV.FOR SWING, SHUTTER LOCATION& QUANTITY Q SUB NOMINAL SIZE SAFETY DIVIDED R323 FRENCH CASEMENT 3' - 4" 5' - 3 1/2" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON STONE SIDE WALL& HEARTH MARK DESCRIPTION HEAD HEIGHT MODEL SHUTTER U FACTOR REMARKS R324 FIXED 3' - 4" 7' - 0" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X R.O. DEPENDENT ON BEAM GROUP WIDTH HEIGHT GLAZING LITES LEVEL 1 R325 FIXED BUTT GLAZED CORNER ±3' - 61/4" 7' - 0" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X PART OF WINDOW R301 UNIT, VERIFY WIDTH, SEE PLAN R101 FIX ED GROUPING WITH DOOR ±1' - 2" 5' - 6" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON DOOR 125a R326 CASEMENT ±1' - 2 1/4" 4' - 0" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 3 PART OF WINDOW R327 & R328 UNIT a R327 CASEMENT 1' - 9" 4' - 0" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 3 PART OF WINDOW R326 & R328 UNIT A FIXED ±1' - 2" 1' - 2" 7' - 4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X B FIXED ±1' 2" 4' - 2" 6' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X R328 FRENCH CASEMENT 3' - 6" 4' - 0" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 6 PART OF WINDOW R326 & R327 UNIT LEVEL 2 R329 CASEMENT WITH SHUTTER 2' - 0 3/4" 4' - 0" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 6 MATCH PROPORTIONS OF R330 O R201 FIXED BUTT GLAZED CORNER GROUPING ±3' - 3 3/4" ±11 - 7 1/4" ±11' - 71/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 PART OF WINDOW R223 UNIT, VERIFY WIDTH, SEE PLAN R330 FRENCH CASEMENT WITH SHUTTERS 4' - 1 1/2" 4' - 0" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 12 MATCH PROPORTIONS OF R329 3' - 3 3/4" ±3' - 1 1/4" R331 FIX ED GROUPING ±5' - 7 3/4" 5' - 1 1/2" 8' - 3 1/2" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 A FIXED ±11' - 71/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 4 VERIFY DIVIDED LITE LAYOUT AS UNIT WRAPS B FIXED ±3' - 3 3/4" 8' - 0" 8' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X A FIXED ±2' - 9 3/4" 5' - 1 1/2" 8' - 3 1/2" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 6 R202 FIX ED GROUPING WITH DOOR 8' - 7 1/2" ±11' - 7 1/4" ±11' - 7 1/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 1 WINDOW R.O. DEPENDENT ON DOORS 201a & 201b R332 FIXED 2' - 8" 5' - 1 1/2" 8' - 3 1/2" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 6 LLI A FIXED 1' - 71/2" ±3' - 1 1/4" ±11' - 71/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 2 RE ELEV.FOR QUANTITY NOTES: _ = B FIXED 1' - 7 1/2" 8' - 0" 8' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X RE ELEV.FOR QUANTITY G.C. TO COORDINATE ROUGH OPENINGS PER MANUFACTURERS SPECIFICATIONS. w N - 2 3' - 1 1/4" G.C. TO PREPAREEXTERIOROPENINGS PER ASTM E2112-01. Lu co C FIXED 3 ±11' - 7 1/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 IF REQ'D 4 RE ELEV.FOR QUANTITY PROVIDE WOOD STRUCTURAL PANELS,IMPACT PANELS OR IMPACT RESISTANCE GLAZING FOR OPENING PROTECTIVESAT ALL NEW WINDOWS, AND DOORS IN ACCORDANCE WITH LD I ( o R203 FIX ED GROUPING ±2' - 8" ±11' - 7 1/4" ±11' - 7 1/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 WINDOW R.O. DEPENDENT ON CHIMNEY STONE SECTION 1609.1.2 OF THE 2012 INTERNATIONAL BUILDING CODE. FASTENING SHALL BE BY MEANS OF CORROSION RESISTANT MACHINE SCREWS FASTENED TO PERMANENTLY cn o cn A FIXED ±2' - 8" ±3' - 1 1/4" ±11' - 7 1/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 4 RE ELEV.FOR OFFSET DIV. LITES,MATCH R202 INSTALLED THREADED RECEIVERS LAG BOLTED INTO THE FRAMING. EACH VIBRATION-RESISTANT RECEIVER SHALL HAVE A MINIMUM WITHDRAWAL CAPACITY OF 490 POUNDS. SEAL Z w o (= B FIXED ±2' - 8" 8' - 0" 8' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X AROUND EACH RECEIVER WITH A SUITABLE SEALANT. ALL PANELS MUST BE LABELEDAND STORED ON SITE. o cc z R204 CASEMENT,VERIFY SWING DIRECTION ±3' - 4" 4' - 3" 8' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 4 RE ELEV.FOR CASEMENT SWING DIRECTION, RE:A600 OWNER DP RATING 50 OR APPROVED EQUIVALENT. 4 , m o R205 CASEMENT ±3' - 3" 4' - 3" 8' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 4 RE:A600 O cv PROVIDE SAFETY GLAZING AT DOORS & WINDOWS PER 2015 IBC 2406. �--� R206 FRENCH CASEMENT 3' - 6" ±4' - 8" ±6' - 8" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 ADJ. DOOR 6 WINDOW R.O. DEPENDENT ON BEAM ABOVE REFER TO ELEVATIONS FOR SHUTTER LOCATIONS. M J m R207 FRENCH CASEMENT ±3' - 4" ±4' - 8" ±6' - 8" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 6 WINDOW R.O. DEPENDENT ON BEAM ABOVE > a) R208 MIXED GROUPING ±5' - 91/2" ±7' - 71/2" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 WINDOW R.O. DEPENDENT ON DOOR 209a co A FIXEDTRAPEZOID ±3' - 4" ±1'-9" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 WINDOW R.O. DEPENDENT ON RAFTER ABOVE B FRENCH CASEMENT ±3' - 4" ±4'-8" ±6' - 8" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 6 ALIGN WITH WINDOWS R206 & R207 CO C FIX EDTRAPEZOID ±1' - 11 1/2" VARIES VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 WINDOW R.O. DEPENDENT ON RAFTER ABOVE D FIXED ±1' - 11 1/2" ±4'-8" ±6' - 8" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 3 ALIGN WITH WINDOWS R206 & R207 R209 FIX ED TRAPEZOID ±7' - 2 1/4" ±3' - 1 1/2" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X R.O. DEPENDENT ON BEAM ABOVE & DOOR 218f R210 CASEMENT WITH WINDOW BOX 2' - 3" ±2' - 91/2" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 ® STAIR 4 RE ELEV.FOR QUANTITY, MATCH MUNTINS R211 R211 CASEMENT WITH WINDOW BOX 2' - 6" 4' - 0" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 ® BATH 4 RE ELEV.FOR QUANTITY& WINDOW BOX LOCATION R212 NOT USED 0.32 R213 MIXED GROUPING WITH WINDOW BOX 2' - 0" 4' - 0" 7' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 6 RE ELEV.FOR QUANTITY,TYPE,WINDOW BOX & SWING = R214 MIXED GROUPING ±7' - 01/2" 4' - 0" 6' - 10" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON WINDOW HEADER/RAFTERS A CASEMENT 2' - 4" 4' - 0" 6' - 10" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 6 B FIXED 2' - 4" 4' - 0" 6' - 10" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 6 2'-03/4" SOLID WOOD FRAME SOLID WOOD FRAME C EGRESS CASEMENT 2' - 4" 4' - 0" 6' - 10" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 6 VERIFY OUTSWING CASEMENT MEETS EGRESS REQ. MATCH WINDOW R215 FIX EDTRAPEZOID ±1' - 61/4" ±4' - 9 3/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 6 ALIGN MUNTINS WITH ADJ. WINDOW T&G BOARDS 2, 6„ T&G BOARDS R216 MIXED GROUPING ±7' - 4 3/4" 4' - 0" 6' - 10" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON WINDOW HEADER/RAFTERS / MATCH WINDOW A CASEMENT 2' - 51/2" 4' - 0" 6' - 10" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 6 B FIXED 2' - 51/2" 4' - 0" 6' - 10" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 6 C EGRESS CASEMENT 2' - 51/2" 4' - 0" 6' - 10" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 6 VERIFY OUTSWING CASEMENT MEETS EGRESS REQ. PPrr R217 MIXED GROUPING 3' - 4" ±6' - 7 3/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER ABOVE - Z , � . N U A FIX ED TRAPEZOID 3' - 4" ±2' - 7 1/2" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 2 E B FRENCH CASEMENT 3' - 4" ±3'-6 1/4" ±6' - 8" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 4 N, R218 MIXED GROUPING 7' - 2" ±6' - 10 1/2" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 R.O. DEPENDENT ON RAFTER ABOVE \-f ', A FIXEDTRAPEZOID 3' - 4" ±2' - 10 1/4" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 2 N: ' ,s7 -••- B FRENCH CASEMENT 3' - 4" ±3'-6 1/4" ±6' - 8" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 4 INSWING CASEMENT FOR WINDOW BOX p1' ), 10 EQ BOARDS +3.. A FIXED 3' - 4" ±1' -7 1/2" VARIES SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 2s•• -//- LATCH R219 FIXED 1' - 5" ±6' - 8" ±6' - 8" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X WINDOW R.O. DEPENDENT ON BEAM ABOVE 8 EQ BOARDS +3„ R220 FIX ED GROUPING 11' - 01/2" 6' - 6" 10'-0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 RE ELEV.FOR QUANTITY LATCH A FIXED 3' - 4 1/4" 1' - 6" 10'-0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 2 RE ELEV.FOR QUANTITY B OUT-SWING CASEMENT 3' - 4 1/4" 4' - 6" 8'-0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 4 RE ELEV.FOR QUANTITY C FIXED 3' - 8" 1' - 6" 10'-0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 2 L3 FINISH FLOOR • • EL.124'- 2" D FIXED 3' - 8" 4' - 6" 8'-0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 4 WOOD SHUTTER FOR WINDOW WOOD SHUTTER FOR R221 FIXED 2' - 4" 6' - 6" 8' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X VERIFY HEIGHT WITH INT. HEARTH TYPE R329 & R330 WINDOW TYPE R322 R222 FIX ED GROUPING 2' -4" ±11' - 7 1/4" ±11' - 71/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 WINDOW R.O. DEPENDENT ON DOORS 201a & 201b A FIXED 2' -4" ±3' - 1 1/4" ±11' - 71/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 2 03 FOR CONSTRUCTION 2017-09-07 B FIXED 2' -4" 8' - 0" 8' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 02 PERMIT REVISIONS 2017-08-25 R223 FIXED BUTT GLAZED CORNER GROUPING ±3' - 6" ±11' - 7 1/4" ±11' - 7 1/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 PART OF WINDOW R201 UNIT, VERIFY WIDTH, SEE PLAN 01 BUILDING PERMIT ISSUE 2017-07-21 A FIXED ±3' - 6" ±3' - 1 1/4" ±11' - 7 1/4" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X 4 VERIFY DIVIDED LITE LAYOUT AS UNIT WRAPS _ ISS.# DESCRIPTION DATE B FIXED ±3' - 6" 8' - 0" 8' - 0" SIERRA PACIFIC- ASPEN DESIGNER SASH 0.32 X PROJECT NO.: 21074.00 0.32 WINDOW SCHEDULE & SHUTTER ELEVATIONS