Loading...
HomeMy WebLinkAboutPEC17-0010_A600_1508779452.pdf 04" °FII' Z.1"61 1., TOWN OF VAIL USE CV IN, PEC APPROVED 5/22/2017 12:00:00 AM II / of /1 OL 041 Eli"' 9 lQ DA,, IAN 7,0% NJ • 1X6 EXT.WOOD DECKING AT UNDERSIDE BIEKER OF BALCONY C 1 1400 0 V '' 21 WRB OVER SHEATHING,TYP. DOUBLE 4X4 OUTRIGGERS®48" O.C., /t/ c\ ' 2" CONT. INSULATION RE:STRUCT. c;p AgG FRAME&PANEL, L3 FINISHED FLOOR ��- = RE: ELEVATION EL. 124'- 2" DOUBLE 4X10 BEAMS DECORATIVE , , rEND CUT, RE:STRUCT. QUARTER ROUND TRIM - 'J lx VERTICAL BATTEN 4X 8 BRACKET WITH CAP FLASHING i�� DOUBLE 3X WOOD POSTS ABOVE 424o Architecture Inc i , c„_,, ,. PP F P 1 (� — — ,� - 5 OWNEh 43-45 RIVA RIDGE LLC I`" CO ER LASHING,LA UNDER WRB AT" li,- %la& ���__��� 950 WINTER ST,#4600 'I SHEATHING AND PROVIDE DRIP EDGE a� rWALTHAM, MA 02451 A A', " ' �� — — �""'� — — — � '� — I OWNER MT.BELVEDERE 45 LLC IIl '�_�, ` .411y. _ I I- _ 1 950 WINTER ST #4600 i .1i\ - �� ~ -- - - .1-1 WALTHAM, MA 02451 �. :41 BLOCKING OVER CONTINUOUS INSULATION , ■ I-VPI 1x6 T&G DECKING,ALIGN W/ INT. CEILING I1��� ��� ARCHITECT 4240 ARCHITECTURE 3507 RINGSBY CT. STUITE 117 DOUBLE 4x6 OUTRIGGERS,RE. RCP DENVER, CO 80216 po oil fern Ii iJ :0'4':di' 2x WOOD TRIM ADDITIONAL LAYER OF ICE&WATER SHIELD OVERCIVILALPINE ENGINEERING,INC. I,IIlx WOOD TRIMIII EAVE FLASHING/RIM SYSTEM, SHINGLE LAPPED ENGINEER 34510 HIGHWAY 6 UNIT A-9 WRB OVER SHEATHING TYP. ,„„lily WITH HIGH TEMPERATURESELF ADHERING LEAVE 3" MIN. BTWN. B.O. MEMBRANE UNDERLAYMENT EDWARDS, CO 81632 CLADDING/B.O. BATTEN & LANDSCAPE SHERRY DORWARD h. LAP FLEX FLASHING OVER COPPER CLEAT `III COPPER ROOFING. 3/4"P.T.EXT. PLYWOOD SHEATHING ARCHITECT P.O. BOX 3766 CONTINUOUS INTERLOCKING COPPER CLEAT •i1Jj ROVERFLASHINGWITH STRUCTURAL MONROE NEWELL / COPPER HALF ROUND GUTTER,TYP. ENGINEER 70 BENCHMARK RD. SUITE 204 HEMMED EDGE INTERLOCKING COPPER FLASHING EXTENDING 8" UP WALL li! ==_�_- - �_m_ _e_____� m _mom��.,. / AVON, CO 81620 INEFIBMBEINIP .e.., VS SSSSS SSSSS SSSSSSSSS SSSSS SS%sssss SS% SS SSSS ENGINEERING 7 / ENGINEER 5737 EXTEND WRB TO WALL SHEATHING ABOVE , ,,,.• R.ccacctaccta LAKEWOOD, CO 80214 S S INTERIORS ASSOCIATES III INTERIOR DESIGN SPRAY FOAM INSULATION 1516 BLAKE STREET — CHAMFERED END CUT ON WOOD TRIM BOARDS DENVER, CO 80202 1 PARTIAL RCP I°° % ►• :_ 3 FJL—_ 1' = 1'-0" I 1 1x6 T&G DECKING,TYP.AT SOFFIT j °° :\°\I\� DOUBLE 4X6 OUTRIGGERS,RE: RCP lx WOOD TRIM OVER 2" RIGID INSULATION SPF INSUALTION \i N )\ SPRAY FOAM INSUALTION t- ' DOUBLE 4x12 WOOD RAFTERS,NOTE LOCATIONS OF STEEL . PAIRED BEAM W/3/4" RIGID INSULATION BTWN., RE:STRUC. PLATE BETWEEN RAFTERS RE:STRUCT. DWGS. BACKER ROD&SEALANT,TYP. L2 WDW HEAD ® EAST ROOF SOFFIT Z 1 O L2 ROOF ®a EAST WALL \11 9 1'-0 CL1_77_ 1 = 1 O ;I�fF 11 BACKER ROD&SEALANT,TYP. ,_ �, WIRE BRUSHED 2x WOOD TRIM,TYP. ALUMINUM CLAD WOOD WINDOW SYSTEM,TYP. EXTERIOR&INTERIOR WOOD COLUMN TRIM, MATCH 1 P=II � SPF INSULATION,TYP. �I.... WINDOW SPECIES AND FINISH 11-41-, 2" CONTINUOUS INSULATION OVER lfilll� _ HSS COLUMN, RE:STRUC. 4111< PLll 0111 F WRB OVER SHEATHING,TYP. WRB OVER SHEATHING,TYP. 3 7Y4" 7-1/" '� I« PLAN DETAIL COLUMN, RE:STRUC. � �, HEAVY TIMBER COLUMN CLADDINGS =�_ // co > ll rLLn_I 1' = 1._0.. Fil ‘10 :±-44. r=' \WI -Nr .7.,,,---.1- _ \— ommn mim EXTEND WRB OVER SILL SHEATHING & 11�\ I. IIIN \ \ W w IIJ FORM BACK DAM AT ALL WINDOWS BACKER ROD&SEALANT,TYP. - 1 Ce 6y,f of of /11 of ii1,-•-•‘ 5,... BRAKE METAL FLASHING BELOW0 i � WOOD SILL 91 114 7� LSA N 'lam° II BACKER ROD& BRAKE METAL COVER, MATCH TYP. W i p - i'I SEALANT,TYP. WINDOW FINISH / / w N' SLOPE 2x WOOD SILL30° 2x8 WOOD CAP,SLOPE 1/8" PER FOOT CC N HEMMED DRIP EDGE AT FLASHING (7) O co PARTIAL PLAN _~ -WOOD CLADDING 2/ RUSTIC CHAMFER COPPER FLASHING AND CLEAT 7:1_—_11" = 1'-0" lx VERTICAL BATTEN,TYP. Z LD -<:( O C 'II I 1 2" CONTINUOUS INSULATION OVER 8v, 'II' III —RABBET IN RAILING&HEMMED DRIP EDGE r = = WRB OVER SHEATHING,TYP. I 1%"O.D. STL.PIPE, PTD. m O 'I \ SIR -THREADED ROD L - - 1=1OU N III RECESSED COPPER GUTTER W/CONT.GRATE COVER ►':;/1 00 I WOOD CAP,SLOPE 1/8" PER FOOT, 1"x1" ANGLE EMBED IN MORTAR COPPER CAP SIM. TO UPPER CAP RAIL M J o II 3/4"STONE TILE,SEE FLOOR FINISH PLAN FOR LAYOUT Q 07 I SNOW MELT SYSTEM IN MORTAR BED .f ■ ■ ■ M1/4"DRAIN BD. ICOUNTERSUNK FASTENERS CONT.WATERPROOFING MEMBRANE __ __ _ _ [_ _ SLOPED MORTAR OVER SLIP SHEET(1/8"PER FT.MIN.) :11 r DOUBLE 3X WOOD POSTS CEMENT BACKER UNIT $" ,, II, EXTEND WATERPROOFING MEMBRANE _. COU TER UNK AS NER ■ ■ ■ ■ "s � 12" MIN. UP WALL&LAP WRB OVER III RE:INTERIORS FOR FINISHES WATERPROOFING MEMBRANE SLOPED WOOD RAIL, FLUSH WITH TOP OF DECK LEAVE 8" MIN. GAP AT BASE OF ' EL FINISH FLOOR IIV ' CLADDING FOR DRAINAGI �I PRESSURETREATED BLOCKING - - - - - / ��IZ■1II''I�LU ■11■ � �� m.. o-' ;: 'a . ._A � -•tea. �/ KNIFE PLATE ATTACHMENT BETWEEN POSTS, RE: _ vdl7lrolllYlr/O� i��� STRUC. jk L2 TOP OF PLYWOOD T.T,T T. T T T N■■■■■■■■■■■m■m■m■■■■■■■ i i■■■■■■mm■■■ �■■■■■ ' 1111' BRAKE METAL FLASHING FROM BALCONY EL. 109'- 4 5/8" ■■■■■■■■■■■■0■0■0■■■■■■■ im■■■■■■■■■__■■■ �■■■■■� ■■■■■■■■■■■■�■�■�■■■■■■■ �m■■■■■■■■■�m■■■ ■■■■■� WATERPROOFING,UNDER GUTTER,AND DOWN FACE OF ■■■■■■■■■■■■m■m■m■■■■■■■ OA x ■■■■■■■■■■■■_■_■_■■■■■■. ■���������■■��� ■11111 2x TRIM Ayifiii •■■■■■■■■■■■m.■�■�■■■■■■■ ■■■■■� 6" RIGID XPS INSULATION 1 "THICK WARMBOARD FLOOR SHEATHING =-------------------------= AAS $ "MAI/1�Il.Aj 1 LrimmEM I LI I I RAFTER, RE:STRUC. RE:FLOOR ASSEMBLIES FOR TYP.DETAILS / lig, 1111i, 8CHAMFERED END CUT ON WOOD GUARDRAIL BOARDS �1��W1�. , �1�1�I 41W,L _EN ' PLYWOOD SOUND BATTS WHEREVERPOSSIBLEAT L1 `�� `.'^"U"""'""'."W"""'"~'JUIril - 2 LAYERSB" EXTERIOR,TYPE GWB 4II 1-K-----i — MAINTAIN EXISTING FIRE RATED ASSEMBLY& ' Li' - T&G DECKING BATT INSULATION BACKER ROD &SEALANT SPRINKLERSYSTEM s 2 LAYERS;"TYPE X GWBik 4X8 BRACKET WITH CAP FLASHING J BEAD AND FIRESTOPPING,TYP BOTH SIDES COPPER CAP FLASHING AT COLUMN BEYOND,TYP. 1-K----1 I HEAVY TIMBER BEAM, RE:STRUC. I BACKER ROD &SEALANT,TYP. 4" RIGID INSULATION WDW HEAD @ BALCONY SOFFIT L__ __ __ __ __ _ _ Aa 2�4il =____J=____J1" = 1'-0" A600 I BRAKE METAL CLOSURE,MATCH WINDOW FINISH L2 EAST BALCONY & WIDW SILL ltl \ N cTYP. HORIZONTAL MULLION liq IIlL_n__ 1" = 1'-0„ / IIIALUMINUM CLAD WOOD WINDOW // WOOD TRIM BEYOND BACKER ROD AND SEALANT,TYP. Alk - -- -- -- -- - ALIGN F.O.SHEATHING WITH F.O.CONCRETEr_ A600 M wILI ` TIMBER SILL W/ DRIP EDGE 1 CONTINUE WRB DOWN OVER FDN DAMPPROOFING _ STONE VENEER OVER DRAIN BOARD GWB �,'■Iww COORDINATE WITH TOWN PAVER SYSTEM, RE:CIVIL :B 04 PERMIT REVISIONS 2017-09-22 CONTINUOUS VAPOR RETARDER II�,� 1%"RIGID INSULATION 03 FOR CONSTRUCTION 2017-09-07 UP TO F.O.SHEATHING II® FINISHED GRADE 02 PERMIT REVISIONS 2017-08-25 A PROVIDE BASE TRIM TO MATCH EXISTING IIS r. -- EL.VARIES, RE:CIVIL 01 BUILDING PERMIT ISSUE 2017-07-21 II�; L1 FINISH FLOOR MATCH EXISTING FLOOR FINISH a II����..� GALVANIZED STONE LEDGER,RE:STRUC. / ISS.# DESCRIPTION DATE I%/��.- EL. 100'- 2.. DETAIL N 0 T E S — — — — — — — — — Joh— — PROJECT NO.: 21074.00 ... • s -six-„ a nl��_ {{iiii- L2 TOP OF PLYWOOD Sn5n5n5n5n5n5n5n5n5n5n5n5$$$5$$$> I I III I FIJH I I _ =11==IIIE JO=E-III= EL. 100' 0" iii iii=iii-iii-iii-iii-iii=ni FWEWEWEWEWEWEHE 111 dill#iiiiiiiii#11i 1iiii#111iiiiiiiiiii 1 i1 ' "' "'_"' BASE aC� EAST WALL ENLARGED ELEVATION EXTERIOR DETAILS 1. REFERTO A250 SERIES FOR INSULATION DEPTH AND R VALUE. ii i- - - _ _ _ iiH EI I iH EI I iiiii=i t ,iiftilliiill1iillliipl i iiiiiiiiiiiiHE 11_77___J 1" = 1'-O" UJ�� 1" = 1'-O" A J ,iii-iii-iii-iii-iii-iii-iii-iii