HomeMy WebLinkAboutPEC17-0010_A604_1508779466.pdf 4,;,‘0,640*114"F g'4 .15
Z 4
TOWN OF VAIL USE
II ....1,
0.
PEC
APPROVED
5/22/2017 12:00:00 AM
6"CAP STONE W/ 1" OVERHANG
W/ DRIP EDGE,SLOPED FOR
DRAINAGE,SEALANT USED AT
ALLSKYWARDJOINTS,TYP.
LAP SELF-ADHERING
WATERPROOF MEMBRANE OVER / CONT.COPPER FLASHING CLOSURE WITH
TOP OF WALL.EXTEND OVER TOP / / ,
/
WATERPROOFING,TYP.
/ / DRIP EDGE TO EXTEND OVER
OF WATERPROOFING,TYP. / i i'
• WATERPROOFINGTO EXTEND UP SIDES OF
W. PLANTER TO CONCEAL FULL SOIL DEPTH
CASING BEAD
CONTINUOUS SELF-ADHERING III I I I I I I I I—I I I VERIFY REQUIRED DEPTH OF PLANTER t o COt on
WATERPROOF MEMBRANE,ALL 111=11 I I I I I I SOIL W/ LANDSCAPE/STRUCT. 4V '1,9
SIDES,TYP. I I I I I I I I I '�Q �', IAN �O
COORDINATE CONCEALED DRIP = I II II
SYSTEM FOR PLANTER W/ MEP& >;I = _ • �� I$, ITO_
LANDSCAPE. ��—�_� p BIEKER
•tt���ice• eio w
< < < < < - • SLOPE FOR DRAINAGE C1(<‘/I: 'PP 4/
PLANTER DRAIN,CONNECT TO GX\\
PERIMETER DRAIN,RE:CIVIL DWGS. I RECESSED COPPER GUTTER W/CONT. F� AR
GRATE
WRB(DASHED) I I 1 X 1 ANGLE EMBEDDED IN MORTAR
CONT.WATERPROOF MEMBRANE,EXTEND
r v i UP WALL.
SPRAY FOAM INSULATION ,� �-
■■u�■■■■mm■■i
6"RIGID XPS INSULATION 4240 Architecture Inc
■■■■■■■mmom
5 I • -: 111111111 '' OWNEh 43-45 RIVA RIDGE LLC
2 LAYERSg" EXTERIOR 950 WINTER ST,#4600
TYPE X GWB 'I T ., . T '- "` ifil41
1 - WALTHAM, MA 02451
��1111' '1' vlkOWNER MT.BELVEDERE 45 LLC
5„ ,`� _A_ _&_ . �1�1� � .1950 WINTER ST,#4600
$ EXTERIORTYPEX GWB GWB CEILING WALTHAM, MA 02451
� " RE: RCP
" LAil
ARCHITECT 4240 ARCHITECTURE
BALCONY DRAIN 3507 RINGSBY CT. STUITE 117
„ � DENVER, CO 80216
STAINED TIMBER LINTEL s..�.��� 2 LAYERSg"TYPE X GWB
STUCCO WALL BEYOND ... �. .is... CIVIL ALPINE ENGINEERING,INC.
�`, ENGINEER 34510 HIGHWAY 6 UNIT A-9
EDWARDS, CO 81632
/\ RE:WINDOW SCHEDULES LANDSCAPE SHERRY DORWARD
�/ ARCHITECT P.O. BOX 3766
VAIL, CO 81658
11 PLANTER �a N. WALL STRUCTURAL MONROE NEWELL
ENGINEER 70 BENCHMARK RD. SUITE 204
MJZ� 1" = 1'-0" AVON, CO 81620
MEP DMCE ENGINEERING
ENGINEER 5737 6TH AVE.
LAKEWOOD, CO 80214
INTERIORS ASSOCIATES III INTERIOR DESIGN
1516 BLAKE STREET
4 DENVER, CO 80202
Z
4 O
.1 .111IFA STONE VENEER
SAM F�A�' RIGID POLY ISO INSULATION
�; �IlI, ���,,yy'B WRB
7 • l a 8"CMU WALL,GROUTED a
'4 Asp Z DIAMETER SIMPSON TITEN HD ANCHOR WITH 1-3/4"
D'ny,eEMBEDMENT DEPTH® 2'-0"SPACING >11
H Aid STONE VENEER WALL ANCHOR,
��•�l���II girt, RE:SPEC.04-43-13 FOR
■■I ' MAXIMUM SPACING&TYPE. O
■■I � DRAINAGE MAT, RE:SPEC.
W
3 STONE ATTACHMENT CMU CC
a@ CLLU_____ 1" = 1'-0" w LP N
LL1 CD N
■ MoiraSTONE VENEER w 0 O co
��1 RIGID POLYISO INSULATION Z LD Q
Mara
O O'
■ ■'rte WRB = -E;
■ ■'ii1 �,� m O
EXISTING BRICK BACKUP WALL O N
■■I STONE VENEER WALLANCHOR, M J M
■ ■���11 �� RE:SPEC.04-43-13 FOR � Q o
00
■ ■'��11 � MAXIMUM SPACING&TYPE. >. 0)
. •i ., DRAINAGE MAT, RE:SPEC. il
CO
2 STONE ATTACHMENT dal BRICK WALL
CLLn__1 1" = 1-0"
IIIN STONE VENEER
rAg
VIII d RIGID POLY ISO INSULATION T
��p WRB +
lOP
iw._��Op 2" PLYWOOD SHEATHING
I F Nd
IIIA: SPRAY FOAM INSULATION
In irr
Ion STONE VENEER WALL ANCHOR,
lin RE:SPEC.04-43-13 FOR
Iii,■■, - MAXIMUM SPACING&TYPE.
IIIiA■■ DRAINAGE MAT, RE:SPEC.
lg■■
1 STONE ATTACHMENT ® STUD WALL
7.1_77__ 1' = 1-0"
04 PERMIT REVISIONS 2017-09-22
02 PERMIT REVISIONS 2017-08-25
ISS.# DESCRIPTION DATE
PROJECT NO.: 21074.00
EXTERIOR DETAILS
A