PEC17-0010_E000_1508779474.pdf
ELECTRICAL LEGEND tiM,1.5, SYMBOL DESCRIPTION SYMBOL DESCRIPTION TOWN OF VAIL USE a. irc .; GENERAL PROJECT NOTES \ LIGHTING DEVICES DISTRIBUTION/RACEWAY ABBREVIATIONS 9 WALL NOTE: RE:ARCHITECTURAL DRAWINGS FOR ADDITIONALCONSTRUCTION REQUIREMENTS MOUNTED 0 RECESSED DOWN LIGHT JO CEILING JUNCTION BOX. ® SWITCHGEAR/SWITCHBOARD. A AMPERES 1:1 1 1. THE CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A COMPLETE, 6"MINAC ABOVE COUNTER _\_ \ WALL WASH ER I- JO WALL-JUNCTION BOX. PEC OPERATIONAL AND PROPERLY FUNCTIONING ELECTRICAL SYSTEMt 9 BRANCH CIRCUIT PANELBOARD. AFCI ARC-FAULT CIRCUIT INTERRUPTED APPROVED 5/22/2017 12:00:00 AM . 3"MI1-N WALL MOUNTED FIXTURE 111 I AF AMPERE FRAME,AMPERE FUSE 2. MATERIALS AND INSTALLATION SHALL COMPLY WITH CODES, LAWS AND ORDINANCES OF \ NON-FUSED DISCONNECT SWITCH. WALL MOUNTED LINEAR FIXTURE T TRANSFORMER. AFF ABOVE FINISH ED FLOOR FEDERAL,STATE AND LOCAL GOVERNING BODIES HAVINGJURISDICTION. \ I 1 I 3. MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY U.L.,ETL,CSA OR ANOTH ER ELEC Nj FUSED DISCONNECT SWITCH. AFG ABOVE FINISHED GRADE AIC AMPERES INTERRUPTING CAPACITY RECOGNIZED TESTING LAB.ALL MATERIAL,EQUIPMENT,WIRING DEVICES,ETC.SHALL BE NEW, TOP BREAKER EQUIP V V V TRACK LIGHTING WALL-DUPLEX RECEPTACLE ONE-LINE DIAGRAM ANN ANNUNCIATOR UNLESS SPECIFICALLY INDICATED AS EXISTING TO BE REUSED. LOAD SLASH INDICATES ABOVE-COUNTER AT AT AMPERE TRIP 4. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO GOVERNMENTAL AGENCIES ANY SHOP CENTER 0MOUNTING H EIGHT(TYPICALALL DEVICES) T # TRANSFORMER(#=KVA). ATS AUTOMATIC TRANSFER SWITCH DRAWINGS REQUIRED BY TH ESE AGENCIES FOR APPROVAL.TH E CONTRACTOR SHALL SECURE OTAWG AMERICAN WIRE GAUGE AND PAY FOR ALL PERMITS,GOVERNMENTAL FEES,TAXES AND LICENSES NECESSARY FOR THE - SURFACE TROFFER GFCI DUPLEX RECEPTACLE C CONDUIT PROPER EXECUTION AND COMPLETION OF THE ELECTRICAL WORK.THIS CONTRACTOR SHALL TTL, 1 U U TRANSFORMER WITH GROUND CATV CABLE TELEVISION SECURE AND PAY ALL FEES AND PERMITS PERTAINING TO THIS CONTRACT, SHALL BE 6-8 9 44" 50" 7 6 C FLOOR-DUPLEX RECEPTACLE (TIT AS NOTED.SECONDARY,KVA SIZE&VOLTAGE RATIO CB CIRCUIT BREAKER RESPONSIBLE FOR WORKER'S IDENTIFICATION AND BADGING, SAFETY, AND LIABILITY TOP OF BOXCCTV CLOSED CIRCUIT TELEVISION INSURANCE. PROVIDE BARRICADES, WARNING SIGNS, AND TRASH REMOVAL FOR THE SAFETY 6'-6"MAX C CEILING-MOUNT DUPLEX RECEPTACLE 0o— DISCONNECT SWITCH E EXISTING OF TH E WORK ERS UNDER TH IS CONTRACTOR'S EMPLOY. 48"MAX 48 DI SHADING INDICATES SPLIT WIRED EM EMERGENCY —Ii it FUSE EC EMPTY CONDUIT 5. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER/OWNER OF ANY MATERIALS OR APPARATUS BELIEVED TO BE INADEQUATE,UNSUITABLE,IN VIOLATION OF LAWS,ORDINANCES, O UTILITY METER EMT ELECTRIC METALLIC TUBING RULES OR REGULATIONS OF AUTH ORITIESHAVINGJURISDICTION. W O � 18"MAX \ IV RECESSED TROFFER ;;; WALL TWO DUPLEX RECEPTACLES IN TWO EP EXPLOSION PROOF GANG BOX. EPO EMERGENCY POWER OFF 6. THE CONTRACTOR SHALL PREPARE THE DOCUMENTS, INCLUDING DRAWINGS, REQUIRED TO •.. GFCI QUAD RECEPTACLE — GROUND EWC ELECTRICWATERCOOLER OBTAIN APPROVAL OF TH E EQUIPMENT AND LOCATIONS OF TH E DEVICES THAT COMPRISE TH E \ \ \ \ \ \ \ \ FA FIRE ALARM FIRE ALARM LIFE SAFETY SYSTEM.WH ERE REQUIRED,THE DRAWINGS AND CUT SHEETS SHALL FEEDER SCH EDULE FLOOR-TWO DUPLEX RECEPTACLES IN TWO FACP FIRE ALARM CONTROL PANEL BE PROVIDED TO A PROFESSIONAL ENGINEER FOR REVIEW AND APPROVAL. TH E APPROVED GENERAL N E RA L N OT E S. I 0 I FLUORESCENT STRIP LIGHT ■, GANG BOX G GROUND DRAWINGS WILL BE STAMPED, SIGNED AND RETURNED TO E.C. TO SUBMIT TO THE BUILDING GND GROUND DEPARTMENT. 1. DIMENSIONS ARE TO CENTER OF DEVICE WITH TRIM.A U.O.N. • DECORATIVE PENDANT CEILING TWO DUPLEX RECEPTACLES IN TWO GANG BOX LOAD CENTER/PANELBOARD GFI GROUND FAULT INTERRUPTER 7. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE, H OA HAND/OFF/AUTOMATIC AND THOROUGH LYBECOME FAMILIAR WITH THE BUILDING STANDARDS,LOCAL JURISDICTIONAL 2. ALL MOUNTING H EIGHTSSHALL CONFORM TO THE LATEST EDITION OK KEYLESS PORCELAIN LAMP H OLDERQ� WALL-SPECIAL PURPOSE RECEPTACLE, IG ISOLATED GROUND CODES AND REQUIREMENTS,AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO OF TH EAMERICANS WITH DISABILITIES ACT,(ADA). ' �✓ CONFIGURATION NOTED IMC INTERMEDIATE METAL CONDUIT 424.0 Architecture Inc DO SO WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE CONTRACT. CEILING MOUNTED EXIT SIGNS,SHADING FIRE ALARM ISC SHORTCIRCUITCURRENT SUBMISSION OF PROPOSAL IN CONNECTION WITH THIS WORK SHALL IMPLY THAT THE BIDDER ID INDICATES FACE(S)ARROW(S)AS V® FLOOR MOUNTED COMBO POWER/TELE/ KAIC KILO AMPERES INTERRUPTING CAPACITY DATA OUTLET © KCMIL TH HAS EXAMINED THE JOB SITE. NO EXTRA CHARGE WILL BE ALLOWED FOR CHANGES AS A INDICATED SMOKE DETECTOR. OWNER RESULT FROM FAILURE TO EXAMINE TH EJOB SITE. DEVICE MOUNTING HEIGHT DETAIL ,-,(4i WALL MOUNTED EXIT SIGNS,SHADING V FLOOR-TELECOMMUNICATIONS OUTLET THERMALDETECTOR. MAX MAXIMUM 8. THE CONTRACTOR SHALL PROVIDE TEMPORARY POWER AND WIRING FOR THE PERFORMANCE (Th INDICATES FACE(S)ARROW(S)AS F MCB MAIN CIRCUIT BREAKER V OF ALL TRADES, FOR THE ENTIRE PERIOD OF CONSTRUCTION AND SHALL REMOVE ALL NO SCALE INDICATED WALL-TELECOMMUNICATIONS OUTLET E MANUAL PULL STATION,MTD 46"A.F.F.UON. MCC MOTOR CONTROL CENTER ARCHITECT 4240 ARCHITECTURE TEMPORARY WIRING AT TH E COMPLETION OF CONSTRUCTION. MCM TH OUSANDCIRCULAR MILLIMETERS 3507 RINGSBY CT.STUITE 117 WALL-COAXIAL CABLE OUTLET F AUDIBLE/VISIBLE NOTIFICATION DENVER,CO 80216 EMERGENCY LIGHTING UNIT ❑QMTD MOUNTED 9. ALL MATERIALS AND EQUIPMENT SHALL BE ERECTED, INSTALLED, CONNECTED, CLEANED, APPLIANCE,MTD 80"A.F.F.OR 6"BELOW PANELA pg OCCUPANCY SENSOR MDC MAIN DISTRIBUTION CENTER CIVIL ALPINE ENGINEERING,INC. ADJUSTED, TESTED, CONDITIONED, AND PLACED IN SERVICE IN ACCORDANCE WITH THE VOLTAGE: 120/208 BUS AMPERES: 200 1 CEILING,UON. ENGINEER 34510 HIGHWAY 6 UNIT A-9 MANUFACTURER'S DIRECTIONS AND RECOMMENDATIONS. CONFIG: 3-PHASE, 4-WIRE MAIN DEVICE: MLO COMBINATION EXIT SIGN/EMERGENCY pp PHOTOELECTRIC SENSOR MIN MINIMUM EDWARDS,CO 81632 LIGHTING UNIT O F� VISIBLE ONLY NOTIFICATIONAPPLIANCE. MLO MAIN LUGS ONLY 10. ALL CUTTING, DRILLING AND PATCHING OF MASONRY, STEEL OR IRON WORK BELONGING TO MOUNTING FLUSH KAIC RATING: 10 SINGLE POLE SWITCH, SUBSCRIPT NEC NATIONAL ELECTRIC CODE LANDSCAPE SHERRY DORWARD THE BUILDING MUST BE DONE BY THIS CONTRACTOR IN ORDER THAT HIS WORK MAY BE ENCLOSUF NEMA 1 $a INDICATES SWITCH INGZONE N NEW ARCHITECT P.O. BOX 3766 PROPERLY INSTALLED,BUT UNDER NO CONDITIONS MAY STRUCTURAL WORK BE CUT, EXCEPTVAIL,CO 81658 CIRCUIT BREAKER LOAD WIRE $3 THREE-WAY SWITCH NIC NOT IN CONTRACT AT THE DIRECTION OF TH E ARCHITECT-DESIGNER OR TH EIR REPRESENTATIVE. ITEM DESCRIPTION NOTES NL NIGHT LIGHT STRUCTURAL MONROE NEWELL QTY POLE AMPS OPT AMPS VA SIZE FOUR-WAY ENGINEER 70 BENCHMARK RD.SUITE 204 11. ALL WORK REQUIRED FOR THE INSTALLATION AS SHOWN ON DRAWINGS INCLUDING LABOR, 1 WASHER 2 1 20 3000 3#12AWG CU-NM-Ba NC NORMALLY EQUIPMENT AND MATERIALS SHALL BE IN STRICT COMPLIANCE WITH THE BUILDING NO NORMALLY OPEN AVON,CO 81620 2 DRYER 2 2 30 10000 4#10AWG CU-NM-B DIMMER SWITCH STANDARDS. 3 BATH RM 4 1 20 150 3#12AWG CU NMB $D NTS NOT TO SCALE MEP DMCE ENGINEERING OC ON CENTER ENGINEER 5737 6TH AVE. 12. PROVIDE COMPLETE METAL RACEWAY SYSTEMS AND ENCLOSURES FOR ALL WIRING 4 BDRM 4 1 15 AFCI 3#14AWG CU-NM-B LOWVOLTAGESWITCH LAKEWOOD,CO 80214 LV OFCI OWNER FURNISH ED,CONTRACTOR TH ROUGH OUTTH E EXTENT OF TH E REQUIRED SYSTEM. 5 LIVING RM 3 1 15 AFCI 3#14AWG CU-NM-B INSTALLED 13. ALL TELE/ DATA BOXES SHALL BE PROVIDED WITH A 1/2" CONDUIT AND BUSHING WITH PULL 6 KITCHEN APPL CIRCS 2 1 20 3000 3#12AWG CU-NM-B $0S OCCUPANCY SENSOR SWITCH OF01 OWNER FURNISH ED,OWNER INSTALLED STRING RUN TO ACCESSIBLE LOCATION.ELECTRICAL METALLIC TUBING (EMT)SHALL BE USED 7 KITCHEN DISPOSAL 2 1 20 1728 3#12AWG CU-NM-B PC PULLCHAIN FOR ALL WALL OUTLETS&TELEPH ONEWIRING RUNNING IN WALLS OR ABOVE HARDCEILINGS. 8 KITCHEN DISHWASHER 2 1 15 2400 3#14AWG CU-NM-B RGS RIGID STEEL 14. ALL RECEPTACLES NOTED AS ISOLATED GROUND (IG) OR DEDICATED OR CIRCUITED AS 9 KITCHEN RANGE-IGNIT 1 1 20 250 3#12AWG CU-NM-B RL RELOCATE DEDICATED SHALL BE PROVIDEDWITH A DEDICATED GROUND AND NEUTRAL. 10 RANGE HOOD 1 1 15 696 3#14AWG CU-NM-B RM REMOVE 15. MINIMUM CONDUIT SIZE SHALL BE 3/4" UNLESS OTHERWISE INDICATED. CONDUITS LARGER 11 KITCHEN REF 2 1 20 2400 3#12AWG CU-NM-B RMS ROOT MEAN SQUARE THAN 2" DIAMETER OR CONDUITS OF ANY SIZE ROUTED OUTDOORS SHALL BE INTERMEDIATE 12 KITCHEN MICROW DRAWER 1 1 20 1500 3#12AWG CU NMB FEEDER SCHEDULE SB STANDBY 13 KITCHEN ESPRESSO 1 1 20 1600 3#12AWG CU-NM-B SC SPLIT CIRCUIT METAL CONDUIT(IMC). KEY/ 14 KITCHEN ICE 1 1 1 20 900 3#12AWG CU-NM-BSDP SUB-DISTRIBUTION PANEL 16. FLEXIBLE CONDUIT CONNECTIONS TO RECESSED LIGHTING FIXTURES SHALL BE MADE WITH AMPS FEEDER CONDUCTORS & CONDUIT 15 KITCHEN STEAM OVEN 1 2 50 6000 3#6, #1OG AWG CU-NM-B SERVICE ENTRANCE FEEDERS ST SHUNTTRIP FLEXIBLE STEEL CONDUIT,3/8 INCH MINIMUM. 16 KITCHEN ICE 1 1 20 900 3#12AWG CU-NM-B RESIDENTIAL DISTRIBUTION PANEL 400N 2[4#3/0, 2"C] SYM SYMMETRICAL 17. FINAL CONNECTIONS TO MOTORS SHALL BE MADE WITH LIQUID TIGHT FLEXIBLE STEEL 17 KITCHEN STEAM OVEN 1 2 50 6000 3#6, #1OG AWG CU-NM-B VOLTAGE: 120/208 BUS AMPERES: 400 600N 2[4#350, 3"C] TP TAMPER PROOF CONDUIT, 1/2 INCH MINIMUM. CONFIG: 3-PHASE, 4-WIRE MAIN DEVICE: MCB 800N 2[ ]4#500, 3-1/2"C TVSS TRANSIENT VOLTAGE SURGE 18 KITCHEN FREEZER 1 1 20 1200 3#12AWG CU NMB MOUNTING FLUSH KAIC RATING: 22 18. WIRE NO. 8 AND SMALLER INSTALLED IN DRY LOCATIONS SHALL BE TYPE THWN OR THHN 19 STEAM SHOWER/SAUNA 1 2 50 10000 3#6, #1OG AWG CU-NM-B 1000N 3[4#400, 3-1/2"C] SUPPRESSION THERMOPLASTIC 600V INSULATED COPPER CONDUCTORS. NO WIRE SMALLER THAN NO.12 20 HUMIDIFIER 1 1 20 1800 3#12AWG CU-NM-B ENCLOSUF NEMA 1 1200N 4[4#350, 3"C] TYP TYPICAL SHALL BE USED FOR LIGHTING OR POWER WIRING. WIRE NO. 8 AND LARGER SHALL BE 21 GAS FIREPLACE 2 1 15 1392 3#14AWG CU-NM-B CIRCUIT BREAKER LOAD WIRE 1600N 5[4#400, 3-1/2"C] UON UNLESS 0TH ERWISENOTED ITEM DESCRIPTION NOTES 2000N 6[4#100, 3-1/2"C] V VOLTS STRANDED.ALL CONDUCTORS INSTALLED IN EXTERIOR OR WET LOCATIONS SHALL BE TYPE 22 BEVERAGE COOLER 3 1 20 900 3#12AWG CU-NM-B QTY POLE AMPS OPT AMPS VA SIZE 2500N 7[4#500, 3-1/2"C] VFD VARIABLE FREQUENCY DRIVE THWN600V INSULATED COPPER CONDUCTORS. 23 MOTORIZED SHADES 2 1 20 1000 3#12AWG CU-NM-B 1 PANELA 1 3 200 RE: ONE-LINE 3000N 8[4#500, 3-1/2"C] W/ WITH O 19. ALL NEW CIRCUIT BREAKERS FOR NEW PANELBOARDS SHALL MATCH NEW BUILDING STANDARD 24 EXTERIOR LTS/RECPS ' 3 1 15 3#14AWG CU-NM-B 2 PANEL B 1 3 100 RE: ONE-LINE 3500N 10[4#500, 3-1/2"C] W/O WITH-OUT PANELBOARD MANUFACTURER AND BREAKER TYPE.THE CONTRACTOR SHALL PROVIDE NEW 25 EXTERIOR LTS/RECPS 3 1 15 3#14AWG CU-NM-B 3 PANEL MECH 1 3 200 RE: ONE-LINE 4000N 11[4#500, 3-112"C] WP WEATHERPROOF ACCURATE AND DETAILED TYPE WRITTEN PANEL DIRECTORIES PER NEC 408.4 FOR ALL NEW 26 AV EQUIPMENT 2 1 20 1800 3#12AWG CU-NM-B TOTAL CIRCUITS: 9 SUBTOTAL 0 VA SEPARATELY DERIVED SYSTEM FEEDERS XFMR TRANSFORMER PANELS.NUMBERED CIRCUITS ARE FOR CONVENIENCE OF DESIGN ONLY.E.C.TO FIELD VERIFY 27 JACUZZI TUB 1 1 20 1176 3#12AWG CU-NM-B 30S 4#10, 1#8G, 3/4"C ACTUAL CIRCUIT NUMBERS USED AND CORRECTLY INDICATE ON "AS-BUILT" DRAWINGS. THE 28 1ST FLOOR/ENTRY 1 1 15 3#14AWG CU-NM-B LOAD CALCULATIONS(PER NEC 220-30) 50S 4#6, 1#8G, 1-1/4"C E.C.SH ALL REMOVE ALL ABANDONED CIRCUITS. 100S 4#1, 1#6G, 1-1/2"C 29 GARAGE DOOR 1 1 20 696 3#12AWG CU-NM-B SUBTOTAL GENERAL LOAD PANELA 51775 VA 150S 4#1/0, 1#6G, 2"C 20. PROVIDE#10 FOR BRANCH CIRCUITS OVER 75'AT 120V. E.C.TO FIELD VERIFY BRANCH CIRCUIT 30 SPARE 8 1 20 SUBTOTAL GENERAL LOAD PANEL B 19282 VA 250S 4#250, 1#2G, 3"C LENGTH SAND SIZE CONDUCTORS FOR VOLTAGE DROP PER NEC. 31 SPACE 7 1 SUBTOTAL GENERAL LOAD PANEL MECH 0 VA 400S 2[4#3/0, 1#2G, 2"C] O WORK NOTE REFERENCE >11111 21. EACH SWITCH, LIGHT, RECEPTACLE AND ALL OTHER DEVICES SHALL BE PROVIDED AND TOTAL CIRCUITS: 72 SUBTOTAL 97082 VA 500S 2[4#250, 1#1/OG, 3"C] INSTALLED WITH A GALVANIZED OR SHERARDIZED PRESSED STEEL JUNCTION BOX OF NOT SUBTOTAL GENERAL LOAD: 71057 VA 800S 2[4#500, 1#2/0G, 3-112"C] O LOAD CALCULATIONS(PER NEC 220-30) 1000S 3[4#400, 1#4/OG, 3-1/2"C] ### MECHANICALEQUIPMENT REFERENCE LESS THAN NO. 14 U.S. GAUGE STEEL. CONDUITS SHALL BE FASTENED WITH LOCKNUTS AND 1600S 5[4#400, 1#350G, 3-1/2"C] BUSH INGS AND ALL UNUSED KNOCKOUTS MUST BE LEFT SEALED.TH ERE MUST BE SUFFICIENT Demand Factors: 1st 10 kVA @ 100% 10000 VA 2500S 7[4#500, 1#500G, 3-1/2"C] ### ROOM FOR WIRES AND BUSHINGS AND DEEP BOXES SHALL BE INSTALLED WH ERE REQUIRED. 5785 SF (Per 220.82(B)(1)) 3VA/SQFT 17355 VA (Per 220-82(B) Remaining kVA ©40% 24423 VA EQUIPMENT FEEDERS BOXES SHALL BE SECURELY AND ADEQUATELY SUPPORTED. SUBTOTAL FROM ABOVE (Per 220.82(B)) 97082 VA 20/W W#12, #12G, 3/4°C LINE TYPES �f 22. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SPECIAL OUTLET BOXES THAT MAY BE GENERAL LOAD AFTER DEMAND FACTOR: 34423 VA 30/W _ W#10, 1#10G, 3/4°C REQUIRED TO ENCLOSE RECEPTACLES. SUBTOTAL GENERAL LOAD: 114437 VA 40/W W#8, 1#1OG, 1"C ( ) BOLD LINES INDICATE NEW OR RELOCATEDEQUIPMENT. RELOCATEDEQUIPMENT MAY B-1 1 252 252 VA 50/W _ W#6, 1#10G, 1-1/4"C INCLUDE"RL". [� LII 23. PROVIDE LOCAL DISCONNECT SWITCHES FOR ALL MOTORS (PLENUM APPROVED WHERE 60/W W#4, 1#10G, 1-1/4"C F— REQUIRED). Demand Factors: 1st 10 kVA @ 100% 10000 VA B-2 1 240 240 VA _ LJ.J CSD N 70/W W#4, 1#8G, 1-1/4"C SCREENED LINES INDICATE EXISTING W (Per 220-82(B) Remaining kVA @ 40% 41775 VA B-3 1 252 252 VA 80/W _ W#3, 1#8G, 1-1/4"C ( N 25. THE E.C. SHALL INCLUDE IN HIS COST THE REMOVAL OF ALL EXISTING ELECTRICAL DEVICES, B-4 1 120 120 VA 90/W _ W#2, 1#8G, 1-1/2"C EQUIPMENT TO REMAIN. LD = C CONDUITS,FIXTURES GENERAL LOAD AFTER DEMAND FACTOR: 51775 VA IRH-1 1 4000 4000 VA 100/W W#1, 1#8G, 1-1/2"C (- -) DASHEDLINES INDICATE FUTURE. (/) (,p 26. AND EQUIPMENT THAT IS NOT TO BE REUSED DISCARD ALL EQUIPMENT AS REQUIRED. E.C. P-1 1 696 696 VA 110/W W#1, 1#6G, 2"C L 0 O SHALL BE RESPONSIBLE FOR DISCONNECTING PRIMARY SERVICE AND TEMPORARY POWER. P-2 1 348 348 VA 125/W W#1/0, 1#6G, 2"C ( ) SCREENED DASH ED LINES INDICATES ZJJ U Q 150/W W#1/0, 1#6G, 2"C EQUIPMENT TO BE DEMOLISH EDOR 27. PROVIDE WARRANTY GUARANTEED FOR A PERIOD OF ONE YEAR AFTER COMPLETION AND Total Feeder Load: 51775 VA P-3A 1 1920 1920 VA 175/W W#2/0, 1#6G, 2"C REMOVED. io CC �O z ACCEPTANCE.REPLACE ALL DEFECTIVE WORKMANSH IP,EQUIPMENT AND MATERIALS WITHOUT Demand Ampere : 143.7 A AT 208V/3PH P-3B 1 1920 1920 VA 200/W W#3/0, 1#6G, 2-1/2"C m J P-4 1 696 696 VA 225/W W#4/0, 1#4G, 2-1/2"C ADDITIONALCHARGES. Q � U N 28. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR TH E SAFEKEEPING OF H IS/H EROWN PROPERTY P-5 1 1656 1656 VA 0 W#250, 1#4G, 3"C - C 30 ON THE JOB SITE.THE OWNER OR TENANT ASSUMES NO RESPONSIBILITY FOR PROTECTION OF P-6 1 232 232 VA 300//W W W#350, 1#4G, 3"C M J Cr) 350/W _ W#500, 1#3G, 3-1/2"C — O TH IS CONTRACTOR'S PROPERTY AGAINST FIRE,TH EFT,OR ENVIRONMENTAL CONDITIONS. P-7 1 1656 1656 VA 400/W 2[W#3/0, 1#3G, 21I2"C] Q 07 VOLTAGE: 120/208 PANEL B BUS AMPERES: 100 P-8 1 696 696 VA io > M 29. WHERE CONDUIT, CABLES, DUCTWORK OR PIPING PASSES THROUGH FIRE RATED FLOORS, 450/W 2[W#4/0, 1#2G, 2-1/2"C] WALLS, OR PARTITIONS, THE SLEEVES SHALL BE COMPLETELY SEALED WITH A FIRE STOP CONFIG: 3-PHASE, 4-WIRE MAIN DEVICE: MLO P-9 1 348 348 VA 500/W 2[W#250, 1#2G, 3"C] MATERIAL THAT IS U.L. LISTED (EQUAL TO DOW CORNING) AND ACCEPTED BY THE BUILDING MOUNTING FLUSH KAIC RATING: 10 600/W P-10A 1 1920 1920 VA 2[W#350, 1#1G, 3"C] 700lW 2[W#500, 1#1/OG, 3-1/2"C] NOTE: P 10B 1 1920 1920 VA 1. NOT ALL SYMBOLS ON THIS LEGEND ARE NOT DEPARTMENT AND FIRE DEPARTMENT AS BEING SUITABLE FOR THE SERVICE. THIS MATERIAL ENCLOSUF N EMA 1 800/W 2[W#500, 1#1/OG, 3-112"C] SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTRUCTIONS IN P-11 1 696 696 VA NECESSARILY USED ON THIS PROJECT. CO CIRCUIT BREAKER LOAD WIRE 1000/W 3[W#400, 1#2/OG, 3-1/2"C] 2. ELEVATIONS INDICATED ON LEGEND ARE TO CENTER, ORDER TO MAINTAIN THE FIRE RATING OF THE PENETRATED WALL, FLOOR, OR PARTITION. ITEM DESCRIPTION NOTES P-12 1 1656 1656 VA 1200/W 4[W#350, 1#3/OG, 3"C] INSTALLATION SHALL BE A THROUGH-PENETRATION FIRESTOP SYSTEM INSTALLED AS TESTED IN QTY POLE AMPS OPT AMPS VA SIZE 1600/W 5[W#400, 1#4/OG, 3-1/2"C] P-13 1 232 232 VA U.O.N. 1 WASHER 1 1 20 1500 3#12AWG CU-NM-B ACCORDANCE WITH ASTM AND UL.THE FIRE RATING SHALL MATCH THE RATING OF THE BARRIER P-14 1 1656 1656 VA 2000/W 6[W#400, 1#250G, 3-1/2"C] BEING PENETRATED. 2 DRYER 1 2 30 5000 4#10AWG CU-NM-B FCU-1 1 4992 4992 VA GROUNDING CONDUCTORSil 30. SUBMIT AN ELECTRONIC COPY OR SIX (6)SETS OF SHOP DRAWINGS,CONTROL DIAGRAMS,AND 3 BATH RM 3 1 20 150 3#12AWG CU NMB FCU-2 1 2995 2995.2 VA G8 1#8, 3/4" C EQUIPMENT CUTS TO THE ENGINEER FOR APPROVAL PRIOR TO STARTING RELATED WORK.SHOP 4 BDRM 1 1 15 AFCI 3#14AWG CU-NM-B CU-1.5 1 2454 2454.4 VA G6 1#6, 3/4" C DRAWINGS SHALL INCLUDE MANUFACTURER'S NAMES, CATALOG NUMBERS, CUTS, DIAGRAMS 5 LIVING RM 1 1 15 AFCI 3#14AWG CU NMB CU-2.5 1 3494 3494.4 VA G4 1#4, 3/4" C — AND OTHER SUCH DESCRIPTIVE DATA AS MAY BE REQUIRED TO IDENTIFY AND REVIEW THE 6 KITCHEN APPL CIRCS 2 1 20 3000 3#12AWG CU-NM-B EF-1 7 8 53.9 VA G10 1-1/0, 3/4" C EQUIPMENT. SUBMITTALS SHALL BE IN LOGICAL GROUPS, PARTIAL SUBMITTALS WILL NOT BE 7 KITCHEN DISPOSAL 1 1 20 864 3#12AWG CU-NM-B G20 1-2/0, 3/4" C EF-2 2 15 30 VA G30 1-3/0, 3/4" C REVIEWED. 8 KITCHEN DISHWASHER 1 1 15 1200 3#14AWG CU NM-B TF-1 1 150 150 VA ABBREVIATIONS: XFMR-REFER TO TRANSFORMER 31. UPON COMPLETION OF CONSTRUCTION, SUPPLY THE ENGINEER WITH ONE COMPLETE SET OF 9 KITCHEN RANGE-IGNIT 1 2 20 250 3#6, #10G AWG CU NMB MUAS-1 1 20000 20000 VA SCHEDULE. MECH-REFER TO MECHANICAL FULL SIZE AS-BUILT DRAWINGS.PROVIDE THE OWNER WITH TH REE(3)SETS OF OPERATION AND 10 RANGE HOOD 1 1 15 696 3#14AWG CU-NM-B MUAS-2 1 20000 20000 VA NOTES: MAINTENANCE MANUALS FOR EACH TYPE OF EQUIPMENT INSTALLED. 11 KITCHEN REF 1 1 20 1200 3#14AWG CU-NM-B 1. W INDICATES NUMBER OF WIRES FUTURE AC 2 8486 16972.8 VA 2. ALL CONDUCTORS ARE SINGLE CONDUCTOR COPPE 32. THIS CONTRACTOR SHALL ASSUME ALL ADDED EXPENSES TO ALL TRADES ASSOCIATED WITH 12 GAS FIREPLACE 1 1 15 696 3#14AWG CU NM B 13 BEVERAGE COOLER 1 1 20 900 3#14AWG CU-NM-B THWN, UON. AMPACITY BASED ON NEC TABLE 310.16. TH E INSTALLATION OF SUBMITTED AND APPROVED ALTERNATE EQUIPMENT. HEATING AND AIR-CONDITIONING LOAD: 94254.7 VA 3.ALL CONDUITS ARE EMT, UON, 'FILL RA11OS BASED 14 MOTORIZED SHADES 1 1 15 500 3#14AWG CU-NM-B 33. THE CONTRACTOR SHALL COORDINATE THE LAYOUT OF THE FIRE ROOM WITH ALL OTHER ON NEC ANNEX C TABLE Cl. 15 EXTERIOR LTS/RECPS 2 1 15 3#14AWG CU-NM-B DISCIPLINES,ESPECIALLY THEFIRE ALARM AND FIRE PROTECTION DESIGN-BUILD CONTRACTORS 16 EXTERIOR LTS/RECPS 2 1 15 3#14AWG CU-NM-B Total Feeder Load: 128677 VA PRIOR TO ANY WORK. 17 AV EQUIPMENT 1 1 20 900 3#14AWG CU-NM-B Demand Ampere : 357.2 A AT 208V/3PH 34. IF ANY CHANGES ARE MADE TO ACCOMMODATE FIELD CONDITIONS NOTIFY THE ENGINEER 18 SPARE 10 1 20 IMMEDIATELY OF WHAT TH E CHANGES WERE,THE REASON FOR THE CHANGES,AND THE COST 19 SPACE 8 1 IMPACTS. TOTAL CIRCUITS: 42 SUBTOTAL 28060 VA 35. LOCATE ALL ELECTRICAL SWITCHBOARDS, PANELBOARDS AND ELECTRICAL DISTRIBUTION EQUIPMENT IN DEDICATED SPACES AND PROTECTED FROM DAMAGE WITH ADEQUATE WORKING LOAD CALCULATIONS(PER NEC 220-30) CLEARANCE ACCORDANCE WITH NEC 110 REQUIREMENTS. PROVIDE PROTECTION FROM ANY *00IOW l'ir*s#a. FOREIGN SYSTEM INSTALLED ABOVE TH E DEDICATED EQUIPMENT SPACE PER NEC 110.26(E). 1715 SF (Per 220.82(B)(1)) 3VA/SQFT 5145 VA 4,0 36. LIGHTING CONTROLS TO INCLUDE TIMECLOCK/PHOTOCELL FOR EXTERIOR LIGHTING WITH SUBTOTAL FROM ABOVE (Per 220.82(B)) 28060 VA A B MECH *.****. .*■.b * MANUAL OVERRIDE CAPABILITY, OCCUPANCY SENSORS, DIMMING SWITCHES, AND TOGGLE 200A 100A 200A •• #'• • a SWITCH ES. SUBTOTAL GENERAL LOAD: 33205 VA MLO MLO MLO **. * *** # Demand Factors: 1st 10 kVA @ 100% 10000 VA = * Z (Per 220-82(B) Remaining kVA @ 40% 9282 VA - i . 1 . ° le RETAIL-1 RETAIL-0 III 200A 200A6 II GENERAL LOAD AFTER DEMAND FACTOR: 19282 VA 200/4 100/4 200/4 MLO MLO W O R K NOTES: ',* *;' *0� O IF EXISTING CONDUIT IS IN GOOD CONDITION AND IS 3", IT MAY BE REUSED FOR NEW '. .' i‘,4, A! SERVICE FEEDERS.FIELD INVESTIGATEAND NOTIFY ENGINEER OF RESULTS. Total Feeder Load: 19282 VA RDP *i;'...; ..*'**it}t Demand Ampere : 53.5 A AT 208V/3PH 400A — © REUSE EXISTING FEEDERS FOR RETAIL PANELS. { L 0. 1F#" 1 Four-Wire,3-phase Short Circuit/Voltage Drop Analysis Calculations • VOLTAGE: 208 120 (E)UTILITY XFMR © SERVICE LOAD SUMMARY /� 03 FOR CONSTRUCTION 2017-09-01 INITIAL CABLE XFMR FINAL FAULT SEGMENT VD CUMM VD 120/208V,3PH,4W 400/4 0,, 200A/3P 0, 200A/3P /'\ RETAIL 1* 57.6 KVA A 02 PERMIT REVISIONS 2017-08-25 U N U 001. Q RETAIL 2* 57.6 KVA A01 BUILDING DEPT COMM. 2017-08-16 S AWG AL M M S VALUE# RDP 128.7 KVA S BUILDING PERMIT ISSUE 2017-07-07 ISC PRI LOAD E #OF OR or SINGLE OR A A CIRC E SEC (SEE ONE- %VD(L- %VD(L- FROM (L-L) VOLT TO AMPS D FT CONDS MCM CU MULTI G G C VALUE MILS D KVA IMP VOLT F(L-L) M(L-L) ISC(L-L) LINE) K VALUE VD N) VD N) N TOTAL: 244.0 KVA UTILITY XFMR-75OKVA 39100 208 600A BUS 677 X 264 2 500 CU S X 43000 1000000 1.99662 0.333710 13048 Fl 11 2.0 1.6 2.0 1.6 677.2 AMPS @ 208/3PH ISS.# DESCRIPTION DATE 800A BUS 13048 208 RDP 357 X 2 2 3/0 CU S X 20800 335600 0.01044 0.989673 12913 F2 12 0.0 0.0 2.0 1.7 I 1 800A BUSWAY 120/208V,3PH,4W 1 PROJECT NO.: 21074.00 RDP 12913 208 PANELA 175 X 25 1 3/0 CU S X 10400 167800 0.25818 0.794797 10263 F3 12 0.3 0.3 2.3 1.9 *BASED ON 80%OF RATED PANEL SIZE RDP 12913 208 PANEL B 65 X 25 1 1 CU S X 5880 83690 0.45665 0.686507 8865 F4 12 0.2 0.2 2.2 1.9 800N #2/0 BLDG STEEL RDP 12913 208 PANEL MECH 125 X 25 1 3/0 CU S X 10400 167800 0.25818 0.794797 10263 F5 12 0.2 0.2 0.0 O #2/OC.W.PIPE IFCABLE USED K VALUE: #1/0 SPRINKLER/GAS PIPE ELECTRICAL FINAL F(L-L)= 1.732 X INITIAL ISC(L-L)XCABLE FT FINAL M(L-L)= 1 /( 1 + F(L-L) ) FINAL ISC(L-L)= INITIAL ISC(L-L)X FINAL M(L-L) K=12 FOR IRCUITS LODED TO MORE THN 50% #1/0 GND ROD LEGEND AND INITIAL PRI VOLTS XCABLE C VALUE K=11 FOR CIRCUITS LOADED LESS THAN 50% NOTES K=18 FOR ALUMINUM CONDUCTORS AT 30C IF XFMR USED FINAL F(L-L)= 1.732 X INITIAL ISC(L-L)X INITIAL VOLTS XXFMR IMP FINAL M(L-L)= 1 /( 1 + F(L-L) ) FINAL ISC(L-L) = INITIAL ISC(L-L)X INITIAL PRI VOLTS X FINAL M(L-L) 100,000 X XFMR KVA XFMR SEC VOLTS 0 POWER ONE-LINE DIAGRAM E000 NO SCALE