.,„.,_,00F,„4, , ,e.,, z 4 GENERAL NOTES MATERIAL SYMBOLS DRAWING SYMBOLS ABBREVIATIONS ZONING & CODE SUMMARY TOWN OFVAILUSE o 1. ALL WORK SHALL COMPLY WITH APPLICABLEFEDERAL,STATE,AND LOCAL CODES,ORDINANCES, 17. WHERE NEW WORK HAS DISTURBED PREVIOUSLY INSTALLED OR EXISTING WORK OR FINISHES,SUCH AES ARCHITECTURAL EXPOSED STEEL M.R. MOISTURE RESISTANT NAME OF PROJECT: HILL BUILDING RENOVATION j1120)11:1:1.r REGULATIONS,LAWS,STATUTES,GUIDELINES AND REQUIREMENTS OF BUILDING AND FIRE AUTHORITIES AREAS SHALL BE REWORKEDAND/OR REFINISHEDAS REQUIRED TO MATCH THE ORIGINAL CONDITION OF THE -© WALL TYPE AFF ABOVE FINISH FLOOR (N) NEW PEC HAVING JURISDICTION. AREA PRIOR TO THE DISTURBANCE. ALT ALTERNATE N/A NOT APPLICABLE ADDRESS: 311 BRIDGE STREET,VAIL, COLORADO 81657 APPROVED SITEWORK THERMAL ALUM ALUMINUM N.I.C. NOT IN CONTRACT 5/22/2017 12:00:00 AM OX WINDOW TYPE PROPOSED USE: EXISTING MERCANTILE BASEMENT&FIRST FLOOR, EXISTING 2.THE GENERALCONTRACTOR(HEREAFTER"THECONTRACTOR")AND SUBCONTRACTORS SHALLCAREFULLY 18. EACH MISCELLANEOUS ITEM OF CUTTING,PATCHING OR FITTING IS NOT NECESSARILY INDIVIDUALLY I I I I I I I I I I I- EARTH BATT BLDG BUILDING N.T.S. NOT TO SCALE STUDY ALL CONTRACT DOCUMENTS AND ACQUIREA THOROUGH UNDERSTANDING OF THE DESIGN INTENT OF DESCRIBED IN THE DOCUMENTS.THE ABSENCE OF SPECIFICDESCRIPTIONS OF CUTTING,PATCHING,OR INSULATIONC1p7AD DOOR NUMBER B.O. BOTTOM OF O.C. ON CENTER SINGLE FAMILY RESIDENCE SECOND &THIRD FLOORS, NO CHANGE THE PROJECT AND THE DETAILS REQUIRED TO ACHIEVETHE DESIGN INTENT. FITTING REQUIRED TO PROPERLY ACCOMMODATE THE SCOPE OF WORK SHALL NOT RELIEVETHE CONTRACTOR CBU CEMENTITIOUS BACKER BOARD OCC OCCUPANTS I I I I II CFCI CONTRACTOR FURNISHED, pp OUTSIDE DIAMETER ZONING DISTRICT: COMMERCIAL CORE 1 (CC1) Q OR SUBCONTRACTOR FROM THE RESPONSIBILITY TO PERFORM SUCH WORK AS REQUIRED TO ACHIEVETHE 3. THE CONTRACTOR SHALL FORWARD REQUESTS FOR CLARIFICATION OR ADDITIONAL INFORMATION WITH DESIGN INTENT OF THE PROJECT. CONTRACTOR INSTALLED OFCI OWNER FURNISHED, BOARD HALL ROOM NAME OCCUPANCY CLASSIFICATION: BASEMENT&LEVEL 1: GROUP M; LEVELS 2 &3: REGARD TO ACHIEVING THE DESIGN INTENT OF THE PROJECT TO THE DESIGNER IN WRITING FOR REVIEW �O oca�d o oro�oogod o og0 GRAVEL - C.I.P. CAST IN PLACE CONTRACTOR INSTALLED GROUP R-3 AND WRITTEN RESPONSE. 19. NOTES APPEARON DIFFERENT SHEETS FOR DIFFERENT SYSTEMS AND CONSTRUCTION MATERIAL.ALL c°�° `�8°O�` ooso do o�°o INSULATION CJ CONSTRUCTION JOINT OF01 OWNER FURNISHED, OWNER �ooOPoPO ca°d80$O <0dR,0 cp�O,0o�<cep °oma _ FF CL CENTER LINE INSTALLED SHEETS ARE TO BE REVIEWED AND NOTES ON ANY ONE SHEET ARE TO BE APPLIED TO ALL RELATED Ujo� °�°�8°�� cA EL. = 100'-0" ELEVATION TAG CONSTRUCTION TYPE:V-B WITH 1 HR FIRE SEPARATION WITH SPRINKLERS 4.THE CONTRACTOR SHALL CHECK AND VERIFY THE CONTRACT DOCUMENTS WITH FIELD CONDITIONS, DRAWINGS AND DETAILS. CLNG CEILING O.H. OPPOSITE HAND BETWEEN OCCUPANCIES,TBD CONFIRMING THAT ALL WORK IS BUILDABLEAS SHOWN, PRIOR TO PROCEEDING WITH THE WORK AND CLR CLEAR OPP OPPOSITE VERIFY ALLSPACEDIMENSIONS AS SHOWN WITH EXISTING JOB CONDITIONS BEFORESTARTING 20. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTERAND QUALITY TO THOSE SHOWN.WHERE SPECIFIED FOAMED-IN-PLACE CMU CONCRETE MASONRY UNIT PART. PARTIAL BUILDING HEIGHT: ±33' - 0"ABOVE EXISTING GRADE OR PROPOSED LOWER CONSTRUCTION.IF DISCREPANCIES EXIST,THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE DESIGNER IN DIMENSIONS,DETAILS,OR DESIGN INTENT CANNOT BE DETERMINED,THE CONTRACTOR SHALL NOTIFY THE CONCRETEO COF CENTER OF FLUE PL PROPERTY LINE GRADE WITH NO MORE THAN 40%ABOVE 33'-0" HEIGHT LIMIT WRITING PRIOR TO COMMENCEMENT OF WORK. DESIGNER IMMEDIATELY FOR CLARIFICATION PRIOR TO PROCEEDING WITH WORK. ,(-:::76:::',:,;„" ;;., INSULATION A100 ELEVATION CO CENTER OF PLAM PLASTIC LAMINATE �� CO`�iQ a a CONCRETE COL COLUMN PLUMB PLUMBING APPLICABLE ZONING CODES: '9 5.PRICING OF THESE CONTRACT DOCUMENTS SHALLINCLUDEALLLABOR,MATERIALS,EQUIPMENT AND 21. ALL DISSIMILAR METALS SHALLBE EFFECTIVELY ISOLATED FROM EACH OTHER TO AVOID CORROSION OR V CONC CONCRETE PLYWD PLYWOOD VAIL VILLAGE MASTER PLAN �Q D° IAN �O SERVICES REQUIRED TO CONSTRUCT THE PROJECT IN ACCORDANCE WITH THE DESIGN INTENT DESCRIBED OTHER BREAKDOWN. 1 CT CERAMIC TILE PT PRESSURE TREATED r THEREIN. GLAZING CPT CARPET PTD PAINTED ADOPTED BUILDING CODES: • 4 sS.. , _ DIA DIAMETER R RADIUS 2015 INTERNATIONAL BUILDING CODE BIEKER 22.A FINISH OR FIRE RATING ON A WALLSHALLMEAN THE ENTIRE LENGTH AND HEIGHT OF WALLIS TO BE :- SAND / GROUT GLASS INTERIOR 2015 INTERNATIONAL RESIDENTIAL CODE 6.THE CONTRACTOR SHALL VERIFY AND COORDINATEALLOPENINGS AND SLEEVES THROUGH FLOORS, FINISHED OR FIRE RATED AS INDICATED. _ _- - _- __ 4 A401 2 ELEVATION DWG DRAWING RD ROOF DRAIN 2015 INTERNATIONAL EXISTING BUILDING CODE 5** 11400 0 V CEILINGS,ROOFS,WALLS,STRUCTURAL MEMBERS,AND ARCHITECTURALELEMENTS WITH EXISTING - - _ ;_- - - _- (E) EXISTING RE: REFER TO 2015 INTERNATIONAL PLUMBING CODE C1 ' ?j y <(f CONDITIONS AND CONSTRUCTION DOCUMENTS FROM CIVIL,LANDSCAPE,ARCHITECTURAL,STRUCTURAL, 23. THE HEAD AND BASE CONDITIONS OF ALL FIRE RATED WALLS SHALL BE TERMINATED WITH EJ EXPANSION JOINT REQ'D REQUIRED 2015 INTERNATIONAL MECHANICAL CODE /1/ ' MECHANICAL,PLUMBING,FIRE PROTECTION,ELECTRICALAND OTHER DISCIPLINES. UL-APPROVED DESIGNS AND MATERIALS. 3 EL ELEVATION R.O. ROUGH OPENING 2012 INTERNATIONAL FUEL GAS CODE Fp MkCj ELEC ELECTRICAL R.O.D. ROOF OVERFLOW DRAIN 2015 INTERNATIONAL FIRE CODE 7.THE CONTRACTOR SHALLPROTECT ALL IN-PLACE ON CONSTRUCTION,LANDSCAPING,PAVING,UTILITIES, 24.SCOPES OF WORK ON THE DRAWINGS NOTED AS"NIC"ARE"NOT INCLUDED IN CONTRACT." MASONRY FINISHES A REVISION ETR EXISTING TO REMAIN R.O.W. RIGHT-OF-WAY 2015 INTERNATIONAL ENERGY CONSERVATION CODE ETC.FROM DAMAGE DURING CONSTRUCTION.ALL DAMAGED AREAS AND ITEMS SHALLBE RESTORED TO EXT EXTERIOR OR EXTRUDED RQMT REQUIREMENT 2014 NATIONAL ELECTRICAL CODE ORIGINAL CONDITION BY THE CONTRACTOR OR SUBCONTRACTOR DAMAGING SAME. 25.ALL FLOOR ELEVATIONS INDICATE FINISHED FLOOR ELEVATION. BRICK - GYPSUM CENTER LINES FD FF FLOOR DRAIN FINISH FLOOR RS SC ROUGH SAWN 2015 AMENDMENTS PER ORDINANCE NO. 14,SERIES 2015 SOLID CORE 8.THE CONTRACTOR SHALL SUBMIT PROPOSED SUBSTITUTION OF SPECIFIEDMATERIALS/PRODUCTS TO THE 26.ALL ROOF ELEVATIONS ARE TO TOP OF ROOF FASCIAUNLESS INDICATED OTHERWISE.ROOF ELEVATIONS HIDDEN LINES FH FINISH HEIGHT SHT SHEET STRUCTURAL DESIGN CRITERIA: ROOF SNOW LOAD: 80 PSF FOR ROOFS 4:12 OR GREATER SLOPE, 100 PSF FOR 2 DESIGNER FOR REVIEW,IN ACCORDANCE WITH PROCEDURES DESCRIBED IN THE SPECIFICATIONS AND ARE NOTED AT HIGH POINTS UNLESS INDICATED OTHERWISE. FIN FINISH SIM SIMILAR 424o Architecture I n c DRAWINGS. �� FLR FLOOR SPEC SPECIFICATION DECKS&ROOFS LESS THAN 4:12 27. PROVIDE BLOCKING OR OTHER SUPPORT AS REQUIRED FOR ALL WALL,FLOOR,CEILING AND �/ / STONE CERAMIC TILE or BUILDING SECTION FRMG FRAMING SPF SPRAY POLYURETHANE FOAM WIND SPEED: 115 Vult OR PER ASCE 7 43-45 RIVA RIDGE LLC / / CARPET IN SECTION FROST DEPTH: 48" 9.THE CONTRACTOR SHALLSUBMIT SHOP DRAWINGS,CUT-SHEETS,AND SAMPLES WHEN REQUIRED BY THE ROOF-MOUNTED SYSTEMS. BLOCKING SHALLBE FIRE RESISTIVETREATEDAS REQUIRED AND PERMITTED BY / / A100 FRT FIRE-RETARDANT TREATED SS STAINLESS STEEL 950 WINTER ST,#4600 / / / F.O. FACE OF STD STANDARD GROUND SNOW LOAD: 145 PSF WALTHAM, MA 02451 SPECIFICATIONS OR DRAWINGS FOR REVIEW BY THE DESIGNER PRIOR TO COMMENCING WITH RELATED CODE. / / / SEISMIC: SHORT PERIOD SPECTRAL RESPONSE: Ss=0.258, LONG PERIOD WORK. GALV GALVANIZED STL STEEL SPECTRAL RESPONSE: S1=0.073 OWNER MT.BELVEDERE 45 LLC 28. SHOULD ANY CONFLICT OCCUR BETWEEN THE ARCHITECTURALDRAWINGS AND THE DESIGNER'S 1/A100 GWB GYPSUM WALL BOARD STRUC STRUCTURE or STRUCTURAL CARPET WALL(OR INTERIOR) SITE CLASS: DETERMINED BY SOILS REPORT 950 WINTER ST,#4600 10. ALL WORK SHALL BE ERECTEDPLUMB,LEVELANDTRUE-TO-LINEIN ACCORDANCE WITH BEST CONSULTANTS'DRAWINGS,THE CONTRACTOR SHALL NOTIFY THE DESIGNER IMMEDIATELY FOR METAL _- - - SECTION GC GENERAL CONTRACTOR T.O. TOP OF �2 WALTHAM, MA 02451 PRACTICES OF THE TRADE,MANUFACTURER'S INSTRUCTIONS FOR THE PARTICULARPRODUCT,AND IN CLARIFICATION. HDW HARDWARE T.O.D. TOP OF DECK IECC CRITERIA: ACCORDANCE WITH THE SPECIFICATIONS. ALUMINUM j -:,- _• HM HOLLOW METAL TYP TYPICAL WORK IS INTENDED TO MEET PRESCRIPTIVE REQUIREMENTS OF THE IECC. ARCHITECT 4240 ARCHITECTURE 3507 RINGSBY CT.STUITE 117 29. COORDINATE PLACEMENT OF ALL CEILING ELEMENTS WITH MECHANICAL,ELECTRICAL,FIRE PROTECTION, / HT HEIGHT U.L. UNDERWRITERS LABORATORY REFER TO BUILDING SECTIONS(A250 SERIES) FOR TYPICAL ROOF&WALL DENVER,CO 80216 11. THE CONTRACTOR SHALL NOTIFY ALLAPPLICABLELOCALGOVERNMENTALAGENCIES WHEN THERE ISA EQUIPMENT.AND OTHER INSTALLERS.WHERE DISCREPANCIES EXIST BETWEEN DRAWINGS AND FIELD INSECT SCREEN HVAC HEATING,VENTILATION, &AIR U.O.N. UNLESS OTHERWISE NOTED ASSEMBLIES. CONDITIONING VERIFY IN FIELD VIF CIVIL N NEED FOR AN INSPECTION REQUIRED BY THE APPLICABLECODE OR BY THE AUTHORITY HAVING CONDITIONS,CONSULT THE DESIGNER PRIOR TO PROCEEDING WITH INSTALLATION. ALPINE ENGINEERING.INC. Q JURISDICTION. MDF MEDIUM DENSITY FIBERBOARD W WIDE or WIDTH ENGINEER 34510 HIGHWAY 6 UNIT A-9 30. REFER TO PLUMBING DRAWINGS FOR LOCATIONS OF ALL FLOOR DRAINS,TRENCH DRAINS,SUMPS AND / STEEL MC MOISTURE CONTENT W/ WITH EDWARDS,CO 81632 12. THE CONTRACTOR SHALL BE RESPONSIBLEFOR THE SAFETY AND CARE OF ALL PERSONNEL AND OF SUBSOIL DRAINAGE UNLESS INDICATED OTHERWISE.IF LOCATIONS CONFLICT WITH ARCHITECTURAL / MECH MECHANICAL WD WOOD LANDSCAPE SHERRY DORWARD ADJACENT PROPERTIES DURING CONSTRUCTION,FOR COMPLIANCE WITH FEDERALAND STATE O.S.H.A. DRAWINGS,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY FOR CLARIFICATION. / WELDET MD IESH M N MRE MFR NNUFACTURER W/OMUM WATERPROOF or WITHOUT ARCHITECT P.O. BOXSECURI81658 RGULATIONS,AND FOR THE PROTECTION OF ALL WORK UNTIL IT IS DELIVERED TO THE OWNER. 31. ALL PENETRATIONS OF DUCTWORK,CONDUIT,PIPING AND OTHER WORK THROUGH FIRE RATED M.O. MASONRY OPENING WATERPROOFING 13. DO NOT SCALEDRAWINGS. ASSEMBLIES SHALLBE SEALED WITH UL-APPROVEDDESIGNS AND MATERIALS TO MAINTAIN THE RATING OF MTL METAL WRB WEATHER RESISTANT BARRIER STRUCTURAL MONROE NEWELL THE ASSEMBLY. WOOD WWF WELDED WIRE FABRIC ENGINEER 70 BENCHMARK RD.SUITE 204 AVON,CO 81620 14. EXTERIOR WALLS ARE DIMENSIONED TO FACE OF STUD UNLESS INDICATED OTHERWISE. 33. SEE STRUCTURALDRAWINGS FOR EXACT LOCATION,SIZE AND THICKNESS OF ALL STRUCTURAL WOOD MEP DMCE ENGINEERING 15. INTERIOR PARTITIONS ARE DIMENSIONED TO FACE OF STUD,UNLESS INDICATED OTHERWISE. ELEMENTS.IF STRUCTURALDRAWINGS CONFLICT WITH ARCHITECTURALDRAWINGS,THE CONTRACTOR BLOCKING OR ENGINEER 5737 6TH AVE. SHIMS LAKEWOOD,CO 80214 SHALL NOTIFY THE DESIGNER IMMEDIATELY FOR CLARIFICATION PRIOR TO PROCEEDING WITH WORK. 16. THE INSIDE FACE OF DOOR JAMBS SHALL BE 6" FROM ADJACENT WALLOR FINISHED COLUMN,UNLESS INTERIORS ASSOCIATES III INTERIOR DESIGN INDICATED OTHERWISE. CONTINUOUS WOOD 1516BLAKE STREET FRAMING DENVER,CO 80202 \ \ \\ WOOD 1 ) 1 ) 1 1 I 1 / PLYWOOD Z SHEET INDEX •CLOSED DOT INDICATES NEW N of N n N m • iriN N O NINFORMATION ON SHEET AT TIME o 0 0 o I I I I� 0 0 0 O O O OI II I I IOF ISSUE w � � � � w � � � � 1-Q o 0 0 o Q o o a O OPEN DOT INDICATES NO o N N N N O N N O REVISION;SHEET ISSUED FOR INFORMATION ONLY = _ > N Z (n Z N Z N O N - N O N - N O N 1- Z Z 1- ZZ 1- Z Z E O O U O O U O O U O Ir N O N cc N O N cc N O N EC- , w , w , Z LD lY (n CC � LD NCC 1 L D N CC E Z I- ZO � E Z I- ZO H E Z I- ZO ' N - cc cc cc (n - cc cc cc N - cc cc cc W = Lu u u =O LLu = Lu O LU LLU 0 LU O CO d L.L. 0_ O CO d LJ_ 0_ O CO d L.L. 0_ LLI C GENERAL (/' NJ CO (n 0 N M 0 (n a- N 0'1 --t (n 0 0 0 0 ( ' 0 0 0 0 ( ' o 0 0 0 - Ce Er) G001 SHEET INDEX&GENERAL INFORMATION • • • • A309 ENLARGED PLANS,SECTIONS&ELEVATIONS • • in III I E101 MAIN FLOOR ELECTRICAL PLAN • W C- CNN G005 GRFA ANALYSIS • 0 A310 ENLARGED PLANS.SECTIONS&ELEVATIONS • E102 SECOND FLOOR ELECTRICAL PLAN • 0 • N G010 EGRESS PLAN BASEMENT&LEVEL 01 • • 0 • A510 WINDOW SCHEDULE&SHUTTER ELEVATIONS • E103 THIRD FLOOR ELECTRICAL PLAN • O • O CS O O 6020 FIRE SEPARATION STUDY • A511 WINDOW ELEVATIONS • • Z Q O A512 WINDOW ELEVATIONS • • • PLUMBING Z CIVIL A513 WINDOW ELEVATIONS • • • P001 PLUMBING SPECIFICATIONS • • 0 0 I 0 m -1571 ONU :"Or)C001 SURVEY 0 • 0 A514 EXT. DOOR SCHEDULE&DOOR ELEVATIONS • • • • P002 PLUMBING DETAILS&FLATOMETRICS • • 0 O M C100 PLAN - CIVIL COVER /1• O A515 INT. DOOR SCHEDULE&DOOR ELEVATIONS • • • P100 BASEMENT PLUMBING PLAN • • 0 Q CD C101 PLAN -GRADING&DRAINAGE • A600 EXTERIOR DETAILS • • • • P101 FIRST FLOOR PLUMBING PLAN • • 0 > CO C102 PLAN - UTILITY • IIII A601 EXTERIOR DETAILS • • • P102 SECOND FLOOR PLUMBING PLAN • 0 I C103 PLAN - SEDIMENT CONTROL • • 0 A602 EXTERIOR DETAILS • P103 THIRD FLOOR PLUMBING PLAN • • 0 ' mM co A603 EXTERIOR DETAILS • I I P104 ROOF PLUMBING PLAN • 0 LANDSCAPE A604 EXTERIOR DETAILS • 0 • L001 LANDSCAPE PLAN • 0 A605 [RESERVED] A610 [RESERVED] A - DEMOLITION-ARCHITECTURAL A650 ROOF DETAILS 1:11, 1111! 1111 TDA100 - BASEMENT LEVEL DEMO PLAN • O A670 FIREPLACE DETAILS • +DA101 - LEVEL 1 DEMO PLANp A671 FIREPLACE DETAILS •DA102 - LEVEL 2 DEMO PLAN A672 FIREPLACE DETAILS • DA103 - LEVEL 3 DEMO PLANA700 STAIR SECTIONS A701 STAIR SECTIONS i ARCHITECTURAL A702 STAIR SECTIONS • • A100 BASEMENT FLOOR PLAN 0 • • A703 STAIR SECTIONS • • lb A101 LEVEL 1 FLOOR PLAN • • • • A704 STAIR SECTIONS • A102 LEVEL 2 FLOOR PLAN • A705 STAIR DETAILS • A103 LEVEL 3 FLOOR PLAN •41) A104 ROOF PLAN • STRUCTURAL A150 BASEMENT LEVEL REFLECTED CEILING PLANIIII S001 GENERAL NOTES • 0 A151 LEVEL 1 REFLECTED CEILING PLAN • • 5100 BASEMENT FOUNDATION PLAN • • 0 d 1111 111111 A152 LEVEL 2 REFLECTED CEILING PLAN • S101 FIRST FLOOR FRAMING PLAN • • • A153 LEVEL 3 REFLECTED CEILING PLAN • • 5102 SECOND FLOOR FRAMING PLAN • • A200 ELEVATIONS • • • S103 THIRD FLOOR FRAMING PLAN • • A201 ELEVATIONS • • • • 5104 ROOF FRAMING PLAN • • ' g I A250 BUILDING SECTIONS • • • S300 SECTIONS&DETAILS • • A251 BUILDING SECTIONS • • • S301 SECTIONS&DETAILS • • • A252 BUILDING SECTIONS • • • • A253 BUILDING SECTIONS • • MECHANICAL 04 PERMIT REVISIONS 2017-09-22 A254 BUILDING SECTIONS • • M001 MECHANICAL COVER SHEET • • 0 03 FOR CONSTRUCTION 2017-09-07 A255 BUILDING SECTIONS • M002 MECHANICAL COVER SHEET • • 0 I- 02 PERMIT REVISIONS 2017-08-25 01 BUILDING PERMIT ISSUE 2017-07-21 A300 ENLARGED PLANS, SECTIONS &ELEVATIONS • • M100 BASEMENT FLOOR MECHANICAL PLAN I 0 A301 ENLARGED PLANS,SECTIONS&ELEVATIONS • 01111 M101 FIRST FLOOR MECHANICAL PLAN O ISS.# DESCRIPTION DATE A302 [RESERVED] M102 SECOND FLOOR MECHANICAL PLAN • • • I PROJECT NO.: 21074.00 A303 [RESERVED] M103 THIRD FLOOR MECHANICAL PLAN • • 0 A304 ENLARGED PLANS.SECTIONS&ELEVATIONS • SHEET INDEX A305 [RESERVED] ELECTRICAL & GENERAL INFORMATION A306 [RESERVED] E000 ELECTRICAL LEGEND & NOTES • • 0 A307 [RESERVED] E001 ELECTRICAL SPECIFICATIONS • 0 I A308 ENLARGED PLANS, SECTIONS &ELEVATIONS • • • E100 LOWER LEVEL ELECTRICAL PLAN • • 0 II P J1 G001