HomeMy WebLinkAboutPEC17-0010_M002_1508779485.pdf SINGLE ZONE MANIFOLD INSTALLATION - No ACTUATORS REQUIRED TOWN OFVAILUSE VI.,, WHEN IN DOUBT, ASK! SCALE: NONE 120) PEC Please review all installation instructions. If there are any WALL STUD APPROVED questions or need for technical assistance call: 1 877 338-5493 5/22/2017 12:00:00 AM 2x HEADER illFLOW METER, TYP WALL GOODS (DRYWALL, ETC.) FROR AMING DDIMEDN IIOXS TEMPERATURE GAGE STUD BAY STUD BAY SUPPLY MANIFOLD LOOPS W X H 2X6 WALL STUD OR FUR OUT 2 14"X36" CLEAR MANIFOLD & TUBING MATERIALS LIST TRIMMER, RIP Y" DOWN TO ► 2X4 WALL CAVITY REQ.) 5-Y" WALL 3 16"X36" CLEAR 1 a ACCOMMODATE PLYWOOD 4 18"X36" CLEAR QTY DESCRIPTION NOTES — e�• >A?S • ID : I. BACKING MANIFOLDYBRACKET, SECURE .R TO PEX UNION TO PLYWOOD BACKING 5 20"X36" CLEAR (COMPRESSION TYPE) I i 16" BALANCE VALVE ACCESS PANEL PER ARCHITECT _ 6 22"X36" CLEAR 36" 14-Y2' 8-Y2 7 24"X36" CLEAR •I�I�IMIMIH_I - RETURN MANIFOLD Y" PLYWOOD BACKING 8 26"X36" CLEAR [1.1,1.2,2.2,3.1] HOSE BIB ,fir COMPRESSION FITTING I ril 9 28"X36" CLEAR 965' I I I I 20 ' ' 1/2"PEX-AL-PEX TUBING 4- s' 10 30"X36" CLEAR iit;yllklll#r,,,v. 2 1000' X 1/2" PEX AL PEX ROLL Ill WARMBOARD PANEL .tip AC ".14, [3.2,3.3,3.4,3.5,5.2] ►,ate �.�'`` ••,, 935' �� ",�,�,T,..; BLOCKING f JOIST SPACE - [[�yy �" - 'W' - ZONE VALVE OR ZONE PUMP rrrj �`- VZs/17 500' X 1/2" PEX AL PEX ROLL .'+ s8y t,W- (MAY BE PLACED IN T� .... 1 RUNT IAPPL CATIONS)ANICAL ROOM FOR HOME SIDE VIEW ,r,f,' ` �Op cci ; %%%y 1 300' X 1/2" PEX AL PEX ROLL [2.1] TO BOILER FILL LOCATION I C (1) SINGLE ZONE (1) 2 2 PORT SUPPLY & RETURN MANIFOLD KIT UNISTRUT PIPE CLAMP MINIMUM OF 2 MULTI ZONE 0MULTI ZONE MANIFOLD INSTALLATION - ACTUATORS REQUIRED 4240 Architecture Inc AXIOM MODEL SF100 W/INTERNAL FLEXIBLE CONNECTOR HOSE,CHECK I 3 PORT SUPPLY & RETURN MANIFOLD KIT SCALE: NONE VALVE AND STRAINER,AND 1/4 HP, OWNER 115V,1 PHASE PUMP. 4 PORT SUPPLY & RETURN MANIFOLD KIT WALL STUD ARCHITECT 4240 ARCHITECTURE ::::; 1 5 PORT SUPPLY & RETURN MANIFOLD KIT SINGLE ZONE AIR VENT 3507 RINGSBY CT.STUITE 117 2x HEADER FLOW METER, TYP FRAMING DIMENSIONS DENVER,CO 80216 FLEX POWER CORDS FOR MANIFOLD BOX 6 PORT SUPPLY & RETURN MANIFOLD KIT CIVIL ALPINE ENGINEERING.INC. TEMPERATURE GAGE 111611 WALL GOODS (DRYWALL, ETC.) Loops W X H ENGINEER 34510 HIGHWAY 6 UNIT A-9 EDWARDS,CO 81632 TUD BAY STUD BAY SUPPLY MANIFOLD2 14"X36" CLEAR -1 7 PORT SUPPLY & RETURN MANIFOLD KIT 2X6 WALL STUD OR FUR OUT SHUTOFF VALVE 3 16"X36" CLEAR MODEL PBLS10 FLOAT MODEL RIA10 ALARM PANEL ' II 2X4 WALL (MIN 5-Y" WALL LANDSCAPE SHERRY DURWARD TRIMMER, RIP DOWN Y" TO ►�� CAVITY REQ.) 4 18"X36" CLEAR ARCHITECT P.O. BOX 3766 CUT OFF SWITCH W/ALARM LITESAND BUZZER, 8 PORT SUPPLY & RETURN MANIFOLD KIT ACTUATOR VALVE, SEE 1 ACCOMMODATE PLYWOOD 1 5 20"X36" CLEAR VAIL,CO 81658 t� TEST,OFF&FLOAT SWITCHES. ZONDESIED OOPSGN ARY FOR --- .. \ ' 411 ,-i: BACKING II O MANIFOLD BRACKET, SECURE 6 22"X36" CLEAR TO PLYWOOD BACKING STRUCTURAL MONROE NEWELL 9 PORT SUPPLY & RETURN MANIFOLD KIT ! I 1 Ii •i I I 16" I I ACCESS PANEL PER ARCHITECT _ 7 24"x36" CLEAR ENGINEER 70 BENCHMARK RD.SUITE 204 RETURN MANIFOLD 14-Y2" 8-Y2' 4"CONCRETE PAD. SUPPLY AND RETURN PEX A _. �I 8 26"X36" CLEAR AVON,CO 81620 10 PORT SUPPLY & RETURN MANIFOLD KIT OR COPPER TUBING — P e. rile** IH! 36" COMPRESSION FITTING Ift Y" PLYWOOD BACKING9 28"X36" CLEAR MEP DMCEENGINEERING I `-1I SILL PLATE 10 30"X36" CLEAR ENGINEER 5737 6TH AVE. FLOOR 1--t — HOSE BIB 1/2"PEX-AL-PEX TUBING 1111111 I I 20°MIN4 3�6, �IIII LAKEWOOD,CO 80214 9 prs. 1/2" COMPRESSION FITTINGS (by pairs) SILL PLATE ►-.iv � BLOCKING I 2 24 VOLT ACTUATORS �---_ 11E:1;/11 ,--WARMBOARD PANEL WARMBOARD SUBFLOOR GLYCOL FEEDER ASSEMBLY INSULATED (MIN R-4)-'c11 SUPPLY AND RETURN - JOIST SPACE JOIST SPACE NO SCALE O PIPING TO MANIFOLD _ 'W' _ SIDE VIEW WALL STUD TANGENTIAL GROOVE SNOWMELT SNOWMELT SNOWMELT RADIANT RADIANT RADIANT RADIANT (5/8"groove typ.) 13/16"NAILING CLEAT THIRD FLOOR MANIFOLD#9 MANIFOLD#8 MANIFOLD#7 MANIFOLD#8 MANIFOLD#9 MANIFOLD#10 MANIFOLD#11 FINISHED FLOOR 1/2"PEX , I I I , I I I , r II1Ii:FIX-IT-ALL'OR'PORTLAND'CEMENT -0-1- ' ' ' .� E11 I XISTING STRUCTURAL WARMBOARD-R PANEL INSTALLEDIL -: ,.- I IH_i_al I _ � • ISTING R ..4AINSULATION OVER EXISTING SUBFLOOR I Z O �I PKinimmk... -- ._. „ FLOOR JOISTS T FL SNOWMELT SNOWMELT SNOWMELT SNOWMELT SNOWMELT RADIANT RADIANT RADIANT RADIANT RADIANT RADIANT N j r SECOND FLOOR MANIFOLD#6 MANIFOLD#5 MANIFOLD#4 MANIFOLD#3 MANIFOLD#2 I MANIFOLD#2 MANIFOLD#3 MANIFOLD#4 MANIFOLD#5 MANIFOLD#6 MANIFOLD#7 Q■ TOP OF WARMBOARD-R PANEL , I I I , I I I , I I I ski , I I I I I �, WARMBOARD-R PANEL I I JOIST i_p_ I I I I I I I I I IPEX TUBING I ,� 'Ii I I ,I i I I , , ■ u �-�luDRILL BURY POINT HOLE ATA 30°ANGLE- ■ WITH 3/4"DRILL BIT DEBUR ALL EDGES -db 3 PANEL CUT BACK DETAIL o�, AROUND BURY POINTS I \ „ O 1 - WARMBOARD-R OVER EXISTING 2 2 STRUCTURAL SUBFLOOR NO SCALE I TUBING IN GROOVE - I Z 13/16" WARMBOARD CONCENTRIC VENT 2 �' 11."--------1 112 �f REMODEL PANEL s0 KIT THRU WALL,TYP SNOWMELT RADIANT VAPOR RETARDER I 300 FIRST FLOOR MANIFOLD#1 I MANIFOLD#1 i.C") 2�� APRPROVED ' 4"O PVC 4"O CPVC OR CODE ,I Il Il I I d bw IS/ (V - ' I I III : C�I %LD ic co N _ CA,TYP. APPROVED PVC VENT,TYP. PEX TUBING N AV 314" 3/4" -� CONCRETE SLAB 2" P-6 o O O EXISTING SUBFLOOR \ _ ' T®'rte ► W p O HX 1:TRIANGLE CDa .d (N)B-1 E)BOILE'i (E)BOILE' TUBE TTP3-40 , Ii P-4 HP2" — p o z I i i INSULATE SUPPLY AND RETURN GAS I I I • • I, ■o• = J LEADERS BELOW SUBFLOOR IN TYP. • I YA4 • O •SPIROVENT AIR - CO JOIST UNCONDITIONED SPACE SEPARATOR �` P 5 0 U N — '(E)CIRC— (E)CIRC— I • ®l • J co .,. P-1 PUMP PUMP • PUMP SHALL CYCLE ON THRU RELAY M M a •s • 4 , BURY POINT DETAIL ri- � A � � A NA FROM END SWITCHES IN MANIFOLDS Q oop • „ • FLUID POWER ENERGY > M SCALE: NONE /� ~p_ _' • 6" MAX.,TYP. MODEL 2012 3-WAY 2- WARMBOARD REMODEL PANEL OVER SLAB 2" 2-1/2" 2-1/2" ,Q SEE PLB e THERMOSTATIC VALVE MAKE-UP WATERS a4 b t NOTE: CO• "-3,,, IA 1..1 • I 1. CLOSE COUPLE MAX. 6"SEPARATION SUPPLY AND RETURNS TO SNOWMELT AND RADIANT FLOOR HEAT LOOP. SEQUENCE BASEMENT , IGF 1[11 THESE ITEMS IN ORDER SHOWN. EXPANSION TANK(ET-1) 2. INSULATE ALL PIPING PER 2012 I.E.C.C.REQUIREMENTS. RS STRAIGHT PANELBOILER PIPING SCHEMATIC 3. SIZE ALL BALANCING VALVES TO 12" MIN. 60"MAX.WATER WARMBOARD REMODEL PANEL SPECIFICATIONS PROVIDE DOMESTIC WATER HEATING NO SCALE PRIORITY CALL TO BOILER&SHUT OFF P1 PRESSURE DROP. A. GENERAL INFORMATION Cn1. Warmboard Radiant Remodel panel is manufactured in the USA, and supplied by: NOTED LLASMECHANICAL LEGEND NOTE ALL DASHED PLUMBING LINES INDICATE BELOW FLOORELEVATION UNLESS OTHERWISE ON DRAWINGS. iWarmboard Inc. SYMBOL ABBREV. DESCRIPTION SYMBOL ABBREV. DESCRIPTION SYMBOL ABBREV. DESCRIPTION 8035 Aoto Soquel 95 Drive, Ste 41A —Cws— CWS CONDENSER WATER SUPPLY V J MOTORIZED GATE VALVE ACCESS DOOR IN CEILING Aptos CA 95003 877-338-5493 CWR CWR CONDENSER WATER RETURN WAFERBALANCE VALVE DUCT SIZE INDICATING SHEET —CHS— CHS CHILLED WATERSUPPLY 20/16 METAL DIMENSIONS.FIRST „ NOTE:NOT ALL VALVES ON THIS LIST ARE CHR CHR CHILLED WATERRETURN — VENTURI NUMBER WIDTH&SECOND 2. Warmboard Remodelpanels shall be 2'x4' OSB with a thickness of 13/16 . LEGEND SPECIFICATION LIST NECESSARILY USED ON THIS PROJECT. IS DEPTH. —RS— RS REFRIGERANT SUCTIONS REDUCED PRESSURE ` SYMBOL DESCRIPTION SPECIFIED MANUFACTURER/MODEL EQUALS BY RL RL REFRIGERANT LIQUID BACKFLOW PREVENTOR DUCT ELBOW W/TURNING VANE WB-R Panels shall be consisting of straights and turns patterns, such channels on 12" centers to interface —RH— RH REFRIGERANT HOT GAS 6 GAS COCK D4 GATE VALVE MILWAUKEE 1105 or 115 NIBCO RED&WHITE R.T F RIGHT TURN P/\PANEL with 1/2" PEX tubing. —HWS HWS HEATING WATERSUPPLY �I, UNION DUCT TEEWITURNINGVANES 0 GATE VALVE IN GROUND BOX MILWAUKEE/105 or 115 NIBCO RED&WHITE —HWR— HWR HEATING WATERRETURN _ _ PIPE REDUCER C•4 GLOBE VALVE _ MILWAUKEE 1590T or 1590T _ NIBCO _ STOCK HAM HPS HPS HIGH PRESSURE STEAM The entire top skin (2'x4') of OSB panel shall have a highly conductive continuous sheet of 1060 series ISI STRAINER MANUALDAMPERW/LOCKING aluminum alloy, bonded to the entire surface. �— CHECK VALVE MILWAUKEE 1509T,1590T,F2974(M)(A),546,or1400SERIES NIBCO STOCK HAM -HPSR HPSR HIGH PRESSURE STEAM RETURN STRAINERW/BLOWOFF VALVE QUADRANT. —C)J AUTO FLOW CONTROL VALVE FLOWSET I YR GRISWOLD - —LPs— LPS LOW PRESSURE STEAM The continuous sheet of aluminum shall completely contour in all channels depths: both turns and straight PLUG VALVE KEYSTONE/SERIES 500 DEZURIK MILLIK EN LPSR LPR LOW PRESSURE STEAM RETURN_ O F.D. FLOOR DRAIN 0 runs. O BUTTERFLY VALVE MILWAUKEE ICL223orCL323 —VAC— VAC VACUUM KEYSTONE CENTERLINE A AIR AIR El EQUIPMENT ROOM DRAIN O STOP/DRAIN VALVE WATTS/B-3000 or B-3001 for 1/2"-3" F.S. FLOORSINK-HALF GRATE MOTORIZED DAMPER Et —N— N NITROGEN F.S. FLOORSINK-I/4 GRATE FLEXIBLE DUCT CONNECTOR Warmboard-Remodel Panels shall be (2'x4') in one of the two tubing channel pattern options. - Straight and BALL VALVE MILWAUKEE IBA-100orBA-150 NIBCO APOLLO F FIRE FIRE Turns - (See Detail BB). lot DRAIN ABOVE i� BALANCING VALVE FLOWSET I ACCUSETTER GERAND —DCW— DCW COLD WATER SPIN-IN FITTING W/DAMPER IlTEMP.CONTROL-2-WAY BY T.C.CONTRACTOR —DHW— DHW HOT WATER 0R.D. ROOF DRAIN 45°DUCT TAKE-OFF 3.AII panels installed will meet or exceed all specifications documented on Warmboard engineered AutoCAD TEMP.CONTROL-3-WAY BYT.C.CONTRACTOR —DHC— DHC HOT WATERRECIRCULATE ; drawings and Warmboard Remodel Installation manual. O.R.D. ROOFDRAIN-OVERFLOW w W WASTE PIPE WI TEMPERING VALVE LEONARD LAWLER moi: U.C.SIZE DOWNSPOUT NOZZLE DOOR UNDERCUT 4. Panel assembly shall be one of the following: —v V VENT PIPE p� PRESSURE REDUCING VALVE WATTS/ACV 115 ® CO CLEANOUT-VERTICAL — ST ST STORM PIPE SOLENOID VALVE ASCO/RED HAT SKINNER BURK ET 11— CO CLEANOUT-HORIZONTAL ® FIRE DAMPER — ST ST OVERFLOW PIPE Warmboard Remodel panel installed over existing structural plywood, decking or OSB.subfloor. (See Detail 1) WAFERBALANCE VALVE - _ - —OD - OD GREASE WASTE I e PIPE CAP Q FIRE&SMOKE DAMPER BRK BREAK-MISC. ® SMOKE DAMPER � i VENTURI FLOWSET/VW GERAND BARCO SO SO SAND OIL WASTE RP OSB PANEL Warmboard Remodel panel installed over concrete slab (See Detail 2) REDUCED PRESSUREGAS GAS PIPE J L EXISTING FIRE DAMPER BACKFLOW PREVENTOR WATTS/9090TS 0 PIPE UP VTR VENT THRU ROOF 6 GAS COCK MAXITROL/BV37 or BV64 - - O PIPE DOWN W+H W H WALL HYDRANT IL RETURN GRILLE PIPE TEE DOWN I\I STRAINER WATTS/SERIES 77S for 1/2"thru 2-1/2" CONBRACO K ECK LEY ® CONNECTION NEW TO EXISTING. 0 HB PIPE TEE UP H B HOSE BIBB FLEXIBLE PIPE CONNECTION STRAINERW/BLOWOFF VALVE WATTS/SERIES 77S with B-6081 VALVE CONBRACO K ECK LEY pQ GATE VALVE GLOBE VALVE P# THERMOSTAT PRESSURE/TEMP.RELIEF WATTS/SERIES 40,140,240,or 340 DCPUMP O t } �y CHECKVALVE OS REMOTE SENSOR A 0 FOR CONSTRUCTION 2017-09-01 0_ MANUAL AIR VENT FLOWSET/AV - islCD BALL VALVE PRESSURE/TEMP.RELIEF CARBON DIOXIDE SENSOR 1 CM CARBON MONOXIDE SENSOR QO2 PERMIT REVISIONS 2017-08-25 Y 1\ P-T TAP FLOWSET/SUPERSEAL UNIVERSAL/45PT-N PETERSON/PETE's PLUG la BUTTERFLY VALVE AIR VENT O C T 8 HUMIDISTAT A 01 BUILDING DEPT COMM. 2017-08-16 BOILER DRAIN VALVE MILWAUKEE NIBCO RED&WHITE 6 PLUG VALVE P-T TAP S BUILDING PERMIT ISSUE 2017-07-07 ,�` – PIPE GUIDE(SLEEVE) O DCW METER OR DCW/GAS ii GAS PRESSURE REGULATOR �IIIIIII� SUB-METER THERMOMETER TRERICE/BX91403 1/2 WEKSLER/AA5H ASHCROFT/MAI GAS COCK(SHUT-OFF)AND UNION PIPE EXPANSION JOINT M SUBMETER ISS.# DESCRIPTION DATE STOP&DRAIN VALVE PIPE ANCHOR y PRESSURE GAUGE TRERICE/600C WEKSLER/EA14 ASHCROFT/MAG SMOKE DETECTOR PROJECT NO.: 21074.00 �:; ® AUTO FLOW CONTROL VALVE EXISTING ITEM LINE WEIGHT ,,7� FIRE DAMPER POTTROFF/VFD-10 i 1��– � 1 _ BOILERDRAIN VALVE DEMO ITEM LINE WEIGHT B . 1 - WARMBOARD-REMODEL PANEL 4 0 FIREEDAMPSMOK DAMPER POTTROFF/FSD-142 BALANCING VALVE MECHANICAL 4 BALL DRAIN W/HOSE END NEW ITEM LINE ® SMOKE DAMPER POTTROFF/SD-142 yc TEMP.CONTROL-2-WAY CONNECTION. WEIGHTS FLEXIBLE PIPE CONNECTION METRAFLEX/METRASPHERE EPDM MASON/MFNC EPDM AMBER-BOOTH/2600 EPDM g TEMP.CONTROL-3-WAY (N) NEW COVER SHEET B - WARMBOARD REMODEL PANEL DETAIL _ _ DIFFUFLEE Y A AUTOMATIC AIRVENT AMTROL 705 HOFFMAN FLOWSET 3-WAY VALVE (E) EXISTING ♦$ NECK SIZE —� PRESSURE REDUCING VALVE (R) RELOCATED ♦♦• FLEX SIZE SCALE: NONE 6GAS PRESSURE REGULATOR SCHLUMBERGER/VARIES - 1>T<I SOLENOID VALVE (F) FUTURE ��111$ #x#x# (� O CFM DIFFUSERI.D. 7 AIR ADMITTANCE VALVE STUDOR VENT - - T PRESSURE GAUGE b VACUUM BREAK ER RIGID DUCT M002 a. BALL DRAIN W/HOSE END CONNECTION APOLLO/78-103-1 1/2"N.P.T.BY HOSE NIBCO STOCK HAM FLOW SENSOR THERMOMETER NOTE:NOT ALL SYMBOLS ON THIS LEGEND ARE NECESSARILY USED ON THIS PROJECT.