Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PEC17-0010_P100_1508779480.pdf
.,co_Aim,..tioip4, im.1.5, a. 4 TOWN OF VAIL USE irc (74 —112o)1111:r PEC APPROVED 5/22/2017 12:00:00 AM 0 000 GG EEA EEGO AA A B • ® 0E000000 • 0 • 0 I I 1 1 1 1 V L p1 1 L I 7 IIIII0 1rctii11uf{1�lillryl_11 ° m 1 a 1 (N)1-1/4" 4.:*: ir T , TIE O " r I I I ,I ° ° (N)1-1/2" ° INTO(N)1-1/S' (E)1" ,- -*. ° ., 1 I 7 I GAS LINE a - 1. 1 o 0 31.-1.(j).4\Z-%.;',4:ASk......:,•1 tl S If#ef 64 CC 0\'.‘j)% �° 4 ° y _—I !!If o. ii it ^ °4 !li J /° °° 1 � I I � I II - I 1 I I 11 I I I `-� „ I I ° I I I I 9PRV1,797 CFH,30 FEET •`p i `- ° a REMOVE ALL XISTING PIPING,Z NE VALVES.PUMPS, 399 C 199 C LE I 199 C LER ETC. FR TING-BOILER . - OUTEEXISTIN 399 CFH 199 CFS 199 CFH ° 0 VALVES FROM THIS MECHANICA ROOM THAT SER E THE � v RCP1 ° 4240 Arch Itectu re I n c (N)IWH1 RETAILSPAO OTHER MECHANICAL ROOM BOIL ° i ° MANIFOLD.PROVIDE ALL NEW PIPING,PUMPS,ETC.PER 1OWNER ° ° BOILER PIPINSCHEMATIC,SHEET M002 PRV Ail 0 I I o 4 0 L_ I 0 I I I I IIIIIIIIIII) ARCHITECT 4240 ARCHITECTURE LJ 1 _1 - A - i 3507 RINGSBY CT.STUITE 117 _i,:, + - ° ° (N)1 1/4" ° ° DENVER,CO 80216 1 GAS LINE I ° ° ° (E)FLOOR DRAIN TO BE CLEANED OUT v I CIVIL ALPINE ENGINEERING.INC. ZA ° L 1 ANDT BE IN OPERATIN CONDITION o ° ° ENGINEER 34510 HIGHWAY 6 UNIT A-9 °i e ° ,_ L WILKINS MODEL I I 1 6 EDWARDS,CO 81632 A I� 1 70 DOUBLE CHECK I LANDSCAPE SHERRY DORWARD 1 1 BACKFLOW PREVENTER 1 I I 6A 1 ° I ARCHITECT P.O. BOX 3766 1 L T 1 I VAIL,CO 81658 ° L r 3/4"DCW TO (® BOILER SYSTEM o 6 ° STRUCTURAL MONROE NEWELL 1 I 1 1 ° ENGINEER 70 BENCHMARK RD.SUITE 204 ipri /° 1 I AVON,CO 81620 [IC I ROUTE AS H GH AS POSSIBLE MEP DMCE ENGINEERING �I ° ° rat T = __ I I AND FIELD VERIFY BEST ROUTING ° ENGINEER 5737 6TH AVE. 0 1111 I W/OWNER/ RCHTIECT PRIOR TO r LAKEWOOD,CO 80214 frre/00 I INSTALLATION ° ° I I �I 8 YA /1,,,, IL L I °°I i? : , , I I =I ' I ° 1 9 I "0 , -T I I $ rt I I 1 � I � T ` ° ,f —I 1 1 10 i HW,CW&RECIRC.LINES i AO°, ' 1 1 UP TO LEVEL ABOVE I ° O Ai. i A I I N t4 , L _I miiiiiii 1 44 ° a I (E)HTP INDIRECT ` —`w i 0 fl 1 1 • I J WATER HEATER I ° °° L L--- - (E)GAS° LINE 7 0 .,i ° ° I °1g 1 ° ® > a °I O — L r--- ° TIE(E)GAS LINE INTO NEW GAS LINE 0 ° ° ° 0 Z y ° ° ° ° [ ° (E)BOILER (E)BOILER I — 181 CFH 181 CFH $ 0 1 _1 4 , 10 �� _ L• ° I ° I F_ t- Lf') U ° a w L17 N CI LI-I L1-0 iN41 [ ,0 . ° , N L ° 1 I I O CD ° I_I_I p O 0 0 H ° I a Z U Q ° I 1 0 !Y z 1 ° ° ° O 0 O U 11 — Q o [ , „ 16 > M ° o ° ° CO L. 0 al ° GENERAL NOTES: °° - ° I° I 1 I 1 I I I 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING PLUMBING CONDITIONS I PRIOR TO ORDERING AND INSTALLATION OF NEW PLUMBING ° ° EQUIPMENT/SYSTEMS. NOTIFY ENGINEER IN WRITING WITH ANY DRAWING/DESIGN DISCREPANCIES. I ° - 19 FIELD VERIFYWITH OWN5R/ARCHITECT/ �° 16 2. FIELD VERIFY LOCATIONS OF ALL SANITARY WASTE,GAS AND WATER ° STRUCTU L(N)GAS&DCW PIPE ROI,TING RISERS IN/ON WALLS PRIOR TO INSTALLATION. ° a OUT OF ROOM PRIOR TO INSTALLATION I A I I I I I I I it L — DCW - PROVIDE 3"FS1 IF EXISTING DRAIN DOES NOT EXIST, ° ° ° ° I TIE NEW 3"INTO CLOSEST SANITARY WASTE,3"MIN., ° ' ® ° -y ° I ° ° ° ° I FIELD VERIFY LOCATION PRIOR TO INSTALLATION °I 19 ° 7 7 ° I-- t--- 7 ---- ° I (N) 1-1/2" DCW REDUCED PRESSURE BACKFLOW . 4, oI PREVENTER,WILKINS MODEL 375XL W/AG-6 AIR I I° Iv 9 ° I I c.9 I GAP,1-1/2" RPBFPTO BE LOCATED UNDER 1-1/2" I I I TIE ALL(E)WATERLINES IN ROOM ACK ° I I DCW METER,SHOWN TO THE SIDE FOR CLARITY IN-O(N)1-1/2" DISNTRIBUTIONLILINEr 20 I GAS LINE FROM ABOVE • ° j C © ° o —I 0 ° ° 1 RELOCATE(E) ATER SOFTENER AS NECE�SARY (N)1-1/2" DCW METER DEMO(E)3/4"DCW METER&WATER ENTRY&REPLACEWI(N)1 1/2" DCW METER, ° L 0 &SERVICE LINE,FIELD VERIFY EXACT LOCATION OFWATERLINE ENTERIGBUILDINGW/ ° ° OWNER/ARCHITECT/CIVIL DRIOR TO DEMO&INSTALLATION ° L 1 I I I 1 I I 1 1 1 1 1 I ID I I I i I I I I I I I I 1 I I i I I I I I I I I A 02 PERMIT REVISIONS 2017-08-25 A 01 BUILDING DEPT COMM. 2017-08-16 S BUILDING PERMIT ISSUE 2017-07-07 ISS.# DESCRIPTION DATE PROJECT NO.: 21074.00 BASEMENT PLUMBING PLAN BASEMENT � PLUMBING PLAN SCALE:1/4"= 1'-0"