Loading...
HomeMy WebLinkAboutPEC17-0010_P101_1508779478.pdf .,cotioil.,4, ta.1.5, TOWN OF VAIL USE PEC APPROVED 5/22/2017 12:00:00 AM 0 0 0 0 0 EEA ID 0 AA B CI D © ® O O 0 0 © ® O ® © 1 I I L 3"FROM GUTTER ABOVE „...„„„,,,,„„,„„ 0 — — 3"FROMIlikir \ \ © it.. ` •.,, ..., �0:, GUTTER *� 3"FROM . 3"FROM 4 ABOVE 6 / GUTTER -27.1. `_ / ABOVE GUTTER / 0 0 _ - o - ` e �a w . ABOVE L 1 t q 1 t . cP $+ � 0 0 � kyr /�{ 1 3"STORM j M .=Elt 1 ACM j --t- / / TORM \ f"(r�uuIut+►► DOWN // // U 3"BDOWN 3"STORM � / / 3"STORM DOWN - _ _ DOWN- - I I I I I I I I I I I I I I \ 042.4o Architecture I n c IGAS LINE UP OWNER � 0 CI �l 1 — • — T �� 4 co © ARCHITECT 4240 ARCHITECTURE I (N)GAS LINES UP 3507 RINGSBY CT.STUITE 117 _ DENVER,CO 80216 G / E o IFici G 1I I I I CIVIL ALPINE ENGINEERING,INC. ZA C • ENGINEER 34510 HIGHWAY 6 UNIT A-9 GPRV2 EDWARDS,CO 81632 6 6A I 1187 CFH 80 FEET 3"FROM LANDSCAPE SHERRY DORWARD ARCHITECT P.O. BOX 3766 GUTTER VAIL,CO 81658 ABOVE STRUCTURAL MONROE NEWELL 1i 1 1 UENGINEER 70 BENCHMARK RD.SUITE 204 1 AVON,CO 81620 0 MEP NI 41 ENGINEER DMCE ENGINEERING T - T illr (il,„, -, 0 11 5737 6TH AVE. I 3"STORM LLAKEWOOD,CO 80214 3"FROM DOWNi GUTTER GAS LINE UP ABOVE i 1-1i 8 YA - I1' I I I I I ] I I I 3"STORM DOWN I - __I ififitI I- t 011 9 r, GAS LINE UP -. ,-1 - I I I I I I I ,_Ij I I I I I I II ❑ 7HW,CW&RECIRC.LINES 10 4"WASTE FROM ABOVE, DOWN IN OR ON WALL TO LEVEL BELOW / 1_ — — PROVIDE WCO AT BASE - O III �� 1/2"COLD ,_ WATER • rii 041 I 2"FS1 / ,_ _ _w_ _ 2 I — - DCW -- - - - �O © I 4"WASTE FROM ABOVE, c� I j I � \IIIIICIC 11 ® / — PROVIDE WCO AT BASE U 2"WASTE FROM ABOVE \, _ i. II DOWN TO 3"WASTE 0 > GAS LINE RVB1 1c�' UPABELOW FLOOR, IrnI I I I I I PROVIDE WCO AT BASE I I Q I 0 = I 1 1 I - - 1] - IID 1 w - IL W 3"FROM L1] , `,, (110 3�� GUTTER -I ABOVE I I w F...,jj —I I I CI ID \J —\ \ e, , , (m ,_ . 0 ,,, c,) (..O \\lb 3"FROM 1 I 0 H / ti I 3"FROM I W p (=> GUTTER - 11 IIS GUTTER Z U Q ABOVE = O2 ABOVE O_ z ® / _ — 0 - B ��' ® I 1 4"WASTE FROM ABOVE, I O -F I I I I I II � mJ�� �uPROVIDE WCO AT BASEI Q O II r C-) ( ' I - -CO M J 1 1 111 1 1 1 1 111 1111 III1 1 1 1111 11 D L._-- - oI DHW Q L----DIIC DCW - J I 16 M I I 0 ; Ii I iI Li CO GENERAL NOTES: ' ' ° 111 I II 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING PLUMBING CONDITIONS r 0 ' PRIOR TO ORDERING AND INSTALLATION OF NEW PLUMBING ml EQUIPMENT/SYSTEMS. NOTIFY ENGINEER IN WRITING WITH ANY E 011 DRAWING/DESIGN DISCREPANCIES. _1 2. FIELD VERIFY LOCATIONS OF ALL SANITARY WASTE,GAS AND WATER I •• III RISERS IN/ON WALLS PRIOR TO INSTALLATION. II _t — 18 3. FIELD VERIFY DOWNSPOUT LOCATIONS OF ALL NEW 3"STORM FROM !• -O • 0 - GUTTERS,AREA DRAINS AND PLANTER DRAINS WITH OWNER/ARCHTIECT 3"FROM GPRV3 HW,CW&RECIRC.LINES PRIOR TO INSTALLATION OF THE ADDED STORM SYSTEM. GUTTER I 35 CFH UP TO LEVEL ABOVE ABOVE \=� 50 FEET GAS PIPE UP WORK NOTES: L. ' I Ill OTIE NEW 3"SANITARY WASTE INTO CLOSEST EXISTING SANITARY WASTE LINE - I e - Ilia19 OF SAME SIZ E. FIELD VERIFY LOCATION OF EXISTING SANITARY WASTE MAINS / PRIOR TO INSTALLATION. NOTIFY ENGINEER IN WRITING WITH ANY DRAWING / al DESIGN VS.IN-FIELD CONDITIONS PRIOR TO INSTALLATION. 0 ® TIE NEW 4"SANITARY WASTE INTO CLOSEST EXISTING SANITARY WASTE LINE I I / ° OF SAME SIZE FROM REMOVED EXISTING RESTROOMS IN THIS AREA. FIELD VERIFY LOCATION OF EXISTING SANITARY WASTE MAINS PRIOR TO - • 20 INSTALLATION. NOTIFY ENGINEER IN WRITING WITH ANY DRAWING DESIGN VS. 1-1/4" GAS LINE DOWN 3"FROM IN FIELD CONDITIONS PRIOR TO INSTALLATION. TO BASEMENT GUTTER 1111 .. �� ABOVE I 3"FROM .. GUTTER I ' I ABOVE II (ii)] i IOW - I 0 -- I 11�-■tI = I -- I ' I I I L I III I I I I 3"FROM CO: GUTTER (N)2"GAS LINE DOWN BELOW TO GRADE 1 ABOVE I LEVEL&INTO BASEMENT TO FOLLOW / GI I I I IIIHI1 REMOVED GAS LINE PATH = I Mt (E)4"FIRE ENTRY LINE FOR O 6 • (E)GAS METER, 150 FEET LONGEST RUN, (E)FIRE SUPPRESSION SYSTEM I (•)I •' I 2000 CFH TOTAL GAS LOAD, 14" W.C.GAS TO REMAIN IN PLACE AS IS I W _ _ PRESSURE,(N)2"GAS MAIN LINE- i P ROM I 1-- 1 I 0 GUTTER I = == I I I ABOVE1111 1111 III 1111 I I I I I I I I I I I A 02 PERMIT REVISIONS 2017-08-25 A 01 BUILDING DEPT COMM. 2017-08-16 S BUILDING PERMIT ISSUE 2017-07-07 ISS.# DESCRIPTION DATE PROJECT NO.: 21074.00 &FIRSFLOOR PLUMBING PLAN FIRST FLOOR T PLUMBING PLAN CALE: 1/4" = 1'-0"