Loading...
HomeMy WebLinkAboutB17-0423 plans approved.pdf _ _. _ _ _ Toviiii al Vail n rr,I rt r On F..: ..... Lions Mane Lodge Unit 701 Remodel 1116 Sandstone Drive Lions Mane Condos Unit 701 Remodel Unit 701 Vail,CO 81657 RECrIVED lircri GUI 'I 6 Z017 Owner: Lou 8 Michelle Bainbndge Address:1116 Sandstone Drive Unit 701 Vail.CO 81657 General Contractor:R.A.Nelson,LLC Contact Jason Money V Town of Vail .,_. Address:51 Eagle Rd./PO Drawer 5400 a. 1116 JIM" , .. . • „. Avon.CO 81620 Phone: (970)949-5152 Fax: (970)949-4379 e-mail: jmoney©ranelson.com No. Description Date 1 ORB Submittal 12.6.12 Drawings Index 2 Building Permit Submittal 1118.12 A000 Cover Sheet A100 Garage Level A101 Main Level A102 Second Level A201 Stair Details E101 Main Level Lighting E102 Second Level Lighting Lions Mane Unit 701 Remodel Cover Sheet Date &11 i Drawn by A000 Scale 1 N ....,„„, (\i4 I Lions Mane Lodge Common Entry Door for Unit 701 Remodel units 701 & 702 1116 Sandstone Drive Unit 701 Vail,CO 81657 General Notes: \\L- No work to take place at this level. Shown for reference only. I L Owner7< Lou&Michelle Bainbridge Address: 1116 Sandstone Drive Unit 701 Up to Unit 701 Vail,CO 81657 General Contractor:R.A.Nelson,LLC \ II i i l I I 1 Contact:Jason Morley \ Address:51 Eagle Rd./PO Drawer 5400 l I I I I Avon,CO 81620 7 I 14-1 Down to unit 702 Below Phone: (970)949-5152 Fax: (970)949-0379 I e-mall: jmoriey@ranelsoacom I I I No. Description Date utline of Main Level AboveO ORB Submittal 7 1 i2 2 Banmit ana PerSubmittal 121812 LiorMane Unit 701 Remodel Gar - EL 8252' O Delo Gage 1/2ra"=1'-0" North /i)fl\ Drawn by A100 Scale 1/2"=1,-0" General Notes: Lions Mane Lodge Demolition: Unit 701 Remodel -Remove all carpet floor coverings,baseboard and casing Unit Sandstone Drive -Remove wall between Breakfast Bar&Family Room. Wood column supportUnit 701 above to remain and to wrap in stain grade wood. Reference structural engineer's beam Vail,CO 81657 drawings. \ -Remove countertop at breakfast bar -Remove countertop at kitchen OW -Remove tile on fireplace hearth to expose concrete hearth Entry Door > L------k lm -Remove windows at breakfast bar and bay window at family room. Owner: Lou&Michelle Bainbridge J _ -Open wall at stairs. See structural engineer's report Address:1116 Sandstone Drive Unit 701 -Remove and replace all doors. Vail,Co 81657 I M"w� p \ momma -Remove popcorn texture at ceiling and false wood beams. Apply skip trowel texture and a °=awe paint. General Contractor:R.A.Nelson,LLC a0°`T cn Contact:Jason Morley paella New Scope of Work: Address:51 Eagle Rd./PO Drawer 152 &� -1"1 General: 5400 ��i (�I Avon,CO 81620 Laundry _ I -New hardwood flooring and wood base throughout. Phone: lmsde49- Room Fax: (970)949-4379 aZ°' Replace all doors and door casing-See door schedule e-mail: jmorley@lanelson.com 2 (Cii) Open Framed wall tor open stair °w Bsyslom with LD1 cah.spin -New drywall texture at ceiling and walls. anddcgst R lots.eSlrutluml plate at open nPairs 5r/cable handrail ° mB -Wrap exposed wood beam and column in stain grade wood to match doors&millwork 0slawtlelai$ Iodtoecap Stairs: -Existing stairs are 2'-10"clear width w/7-3/4"risers& 10"treads. Clear stair width toQb� °fail remain as widening the stairs is not possible due to existing structural constrains. REQ, `ED -Open walls at stairs to kitchen/dinning room. See structural engineer drawings. (� -Expose open end of stair treads and risers. • Cr- NCE �FOR CODE -Install new horizontal cable railing between wood wrapped columns at stairs with 2x3 wood cap. Date 1 i i--..... ,.:;.::;:.:. Install new1-1/2"round grabrail. � 2 3• Ktte„enstallnewwood treadsandrisersover existingstair framing. Treads to have 1” - -""'"o ' rOOerhang and 1-1/2"thick nosing where exposed. ,1 ugh r°PI. existing exposed stair strings with stain grade trim to match. C'®d . !4_ D Family Room: �0 Install new bay window with new window casing. L= o� \ -- ., -Relocate cable and provide blocking for new wall mounted flat screen TV. Datepose existing concrete fireplace hearth,repair and stain concrete. Existing gas 1 DRBSubmittalf l ': ; f placeandbricksurroundtoremain2 BPIdi nRerma Sp,mi„al I2,H„i ". \ ' i •;',.. inning Room: xisting mirrors&trim on walls to remain. Install new reclaimed wood paneling below -J I I ''�' mirrors. II Breakfast Nook: 'CZ I I Room -Replace countertop with new acid etched zinc countertop. Leave 1”gap between wall CD Egress ail to I I and install at 35"a.f.f. Stairs. Breakfast I I "°°� II I -Replace existing windows with new Jeld Wen Windows. I Kitchen: -Replace countertops with new Granite"Star Beach" -Replace kitchen sink&faucet. dl -Stub gas for future gas range. Gas stub to come from unit gas meter. Run through El I crawlspace below garage and up through exterior wall at laundry room. ReplaceWindows Existing v�\\�\����\�111��`�\\ -Provide new 300 CFM microwave,vented through roof. Sheetmetal vent to remain w"m'� �l�3—t� exposed-paint. neplace00,;y -Refinish existing cabinets and replace hardware. Bey Window Laundry Room: Lions Mane Unit 701 Remodel -Existing washer/dryer&shelving to remain. Main Level - EL OM4,7.1411. 8256'-6" /r,NoNh Date /\ Drawn by A101 Scale 1/2"=1'-0" General Notes: -Remove all popcorn ceiling texture,apply skip trowel texture and paint. Bainbridge Remodel Demolition: Lions Main Unit 701 -Remove all carpet floor coverings,baseboard and doors -Removal all fixtures and finishes on bathrooms back to existing drywall. New Scope of Work: Replace window in General: Ill 2nd bedroom -New hardwood flooring and wood base at Hallway and Master Bedroom .(-----j -Replace doors and door casing-See door schedule —_--1_, O -New drywall texture at ceiling and walls at work area Stairs: Owner. Lou b Michelle Bainbridge Install new horizontal cable railing between wood wrappedAddress 11,BSa alsipne Drive-Unit]a1 Vail,CO 8165] 2x3 wood cap. columns at stair landing with 9 -Install new wood treads and risers with new wood grab rail from 2nd level to 3rd level. Stairs are currently 2'-10"clear width with 7-3/4"risers and 10"treads. These dimensions General C°n acl°r.R0.Nelson,lLC ��� Contact:Jason CO 81 "�� Addmss:51 Bapk Rd.y PO Drawer 50110 are to remain since stair structure cannot be modified due to existing structural constrains. A 0)�B QB Phone:(9]0)909-5152 202-2iM Bedroom Master Bedroom 201: Fm19]8)909-0a]9 il: 1modaY@Mn65.'cam -Increase opening at door from 3'-0"to 4'-0"and install new door with sliding barn door hardware r 7 6,.M,.,°,©edm°m -Install new wood flooring and wood baseboard. J -Replace exterior door to common deck —1-3Bathroom#1 203: mrpaaepDpn grmmsm -Remove all existing finishes. Nm clear B aMinDm°°"°"° -Replace vanity with new 36"vanity,install new granite countertop&sink w/faucet. lo face aoF clear 5 °`g'a` le cabinet -Reinstall existing toilet. bi t ,o -Remove existing tub and install new walk-in shower with 4"curb,waterproofed shower pan,new tile shower pan and full height tile surround. Movelumbin to 0 O and install new shower bench. p 9 pposite wall O20a.Bmh l:, O -Install new glass bypass shower doors. -Install new tile floor with 4"tile base. 209-Bath a2 * - 2nd Bedroom 202: 0 Install new hardwood flooring,base and wood doors. I Lq 1 Bathroom#2 204 2 -Same scope as bathroom#1,however the tub/shower layout is to remain. Ciif — MO !Manned. / UP Remove Donipn of No. Description Date r open Start Lantlilm \, Moirdeng wad lNowca i DRB Submittal (2.6.12 �0 sap ap and Now cable 2 BDildinp Permit Submillal 121812 ling system with ' IOD®Dand gnpabk .. handrail. ll B Cldeerear timet mbetween nMween l to remain. ' H wrapped loco low app Ii �le I New cable railing al open _ =cog gt I / New cable railing system with wood top cap and gripable handrail al open slain 19 Bainbridge Remodel 2n. evel - EL 8261' rthO2L 112d ev1e-01 " TTT Detm Orawn by 02 • Scale 112'=1'-0• F71 r-71 -41.11111 • Bainbridge Remodel Lions Main Unit 701 OwnerLou 8 Michelle Bainbridge Address:1116 Sandstone Drive-Unit 701 Vail,CO 81657 GeneralContractor:RA.nelson,LLC Contact:Jason Morley Address:51 Eagle Rd./PO Drawer 5400 Avon,CO 81620 Phone:(970)949-5152 F. (970)949-4379 e malt: jmoney©renolson.eec 301 -3rd Bedroom - No Work 303 - Bath#3 - No Work Description Date 1 DRB Submittal 1?617 2 Buildin0 Permit SuOmidal 1718 12 \ I 302- Closet- No Work bridge Remodel 0 3rd Level North /\* 3rd Levet EL 8270' rawn by A103 Scale 1/2"=1'-0" Bainbridge Remodel Lions Main Unit 701 General Notes: -Existing stairs have a clear width(drywall to drywall)of 2'-10". Due to structural constraints,these walls cannot be moved to create a 3'clearance and the existing clearance of 2'-10"above the stringers will be maintained. -The existing framed stair treads and risers have a riser height of 7-7/8"and wpm a°°`° tread depth of 10-1/2"and the existing stair structure will remain. This stair Ramovpe Slek.,openmcur existing structure will get new wood treads&risers. The riser height will remain the air design. Reference Wcwal Drawing same- The treads will get a 1'I overhang for a total tread depth of 11"with a Ower: Lou 8 MmMM Bainbridge • 0 ' Address:1116 Sandstone Drive-Unit 701 1-1/2"thick nosing. V 1,CO BtfiS] 1 -The existing wood stringers are visible above the stair treads/risers and will remain. The stringers will be wrapped in 1/2"stain grade millwork to match the wood stairs and will have a minimum clear width of 2'-7', General Contractor:RA.Nalson.L LC Contact:Jason Morby _ At the main level to second level stairs and a portion of the 2nd level to 3rd level Address:51 Eagle Ra.,PO Drawer5a0p Awn,CO 81620 P.m:(MD 9.5152 o�� stairs,an opening will be created in the existing solid wall to expose the open Fax: imo°ey@ra 0mm Ila end of the stairs- A new horizontal cable rail will be installed with a 2"x3"wood — cap,no less than 36"in height. —– zndL61'-0"eve -A grip 1-1/2"handrail will be installed at one side of the stairs at 36"in height. V OSecond Level Stairs 1/2'-1'0" • • . 411 ————— _3rd Level No. Description Data 1 2 ORB dnoo Submittal"' submittal 121812 I � I cbbmns .p- 41 I I �, Cable Railing to boil ©� r poacc ciiseng a ailing al s�ppam�.n ai g. Elimpe� Horvnnbl Cabo Robing vote 2s3 waoa IaP cap. _ Anthea cables to 1?banse pble alUcbea m wopa posh. IIrr —2n1Lw'e-pe'l �_ — __—!j M--- t 0 O 000 inbridge Remodel'"`"`" °°°"a°&r� ""Exposed ---- — —I Stair • ____M a_n L6ev�el l'1°'516— :'—! ain Leve 56 --— �6 � 56' ^Zl 7 Dae Dawn by OMain Level Stairs O Ma n Leveel Stair Landing A201 Scala 1/2"=1'-0' Lions Mane Lodge Unit 701 Remodel 1116 Sandstone Drive 1 Unit 701 Vail,CO 81657 Electrical General Notes: -Replace all switched with Decora dimmer switches. -All existing outlet locations to remain. Replace with new outlets. Removehoexislingcan -Lighting in laundry room to remain. lights.Replace with 6' ackwilhaacew,th and -Hardwire plug for existing fireplace fan and control via switch. ,•J — I 1 new pendent.Center -v,I:Remove existingsconce at stairs-1 each Owner Lou&Michelle Bainbridge CD J S over dinning room table Address: 1116 Sandstone Drive I -D2:Remove existing can lights or ceiling mounted fixtures-11 ea Unit 701 I 3-way switch TL7 Vail,CO81657 C 1:Add new 4"can light 8 ! hJ -TL1: Add new 6'track light with 4 new art lights and 1 new pendent. General ContractorRA.Nelson,LLC s Center over dinningroom table. contact.Jason Morley Existing Electrical S ,:t7-2, Address:51 Eagle Rd./PO Drawer 379 Panel I I I r. - -TL2: Add new 2'track light with 2 new art lights. Center over fireplace. Avo,CO 81620 -P1: Install 3 new owner supplied pendents. Phone: (970)949-5152 ;02 -Existing ceiling fan location at kitchen to remain. Install new owner Fax (snde70)y@ane son corn e-mail: jmorte (I supplied fan with light kit. Mount new -Rough cable TV in wall to proposed TV location thermostat for -All new lighting to comply with Town of Vail Energy Code Requirements. baseboard heaters s -SP: Install 4 new ceiling speakers. Run speaker wire to TV entertainment system. SP SP Add new switch D2 outlet above Hardwire existing gas fireplace tan /S lights.Add 3 new owner and control with refrigerator I Remove 5 existing can switch Remove one existing can D2, supplied pendents. —�•• lights.Replace with 2' ® Existing ceiling fan lc • track with 2 art lights. remain. i •,.`'�i Center at fireplace Remove outlets at ..:.:‘.i.:::::!. ., backsplash and replace with plug- •i'' �-i, mold below upper L2'- coun[erlops. O •D2 i I•}•_ Replace P, I�2•• untlercabinet — I / A Add new floor I �'c lighting Ir —4-—r — __„------,0 :D2! i outlet.CoordinateI Y with furniture la out No. oo cnp on pate I•02�I P1 I\ i rl •�" 1 oRasvbmatalO FD2, , ,u. 2 Building Permit Submittal (2612 ,' I 12.18.12 s _ -- II - I I sP II----....) II II II ` Owner Yrovided N BB2 E1 p2` BEI I IC Nry Replace existing 6' th Existing light location over baseboardheaterroni Lions Mane new 6'electric hydropic 1 Remodel countertop to remain. baseboard heater. eReplace existing 12' basrd heater with Replace with owner supplied fixture-Hardwire new 10aelectric hyd nic baseboard heater.Add M-`` Level Li. ing new outlet at end Yale pawn by E 1 0 1 Scale 112"=1,0" iimmwmidmimila Lions Mane Lodge Unit 701 Remodel 1116 Sandstone Drive Unit 701 Vail,CO 81657 New 6'electric Replace existing Replace existing Electrical General Notes: hydropic 10'baseboard baseboard healer baseboard heater Dealer with newt with new -Replace all switches with Decora type switches with outlet on entl, electric hydropic electric nydronic -All existing outlets to remain heater.Cenfer betwee^beds. J -Lighting in both bedrooms to remain Owner: Lou&Michelle Bainbridge 1 / -D 1: Remove sconce at hallway- 1 each Address: 1116 Sit andstone Drive Vail,CO 81657 LJ L -Cl:Add 4"can lights at hallway-2 each BBa Bea -C2:Add 4"wet can at showers-3 each General Contractor:R.A.Nelson,LLC BBs -Si: Replace vanity sconces with owner provided fixtures Contact Jason Morley I -Replace in wall electrical heaters in bathrooms. Address:a51 EagleORd.f Po Drawer -Move cable W cable in wall at new N location. Phone: Avon,0949-5152 Fax: (970)949-4379 e-mail: jmodey@ranelson.corn 5 –_______) , C1 I I KN'..------11P-1-1 SS$ A In WallHealer ) ).- 7 51 4' $ IX1 :S. :DtIn Wall He., IX __ . 1 I rq T tiD No. Desenation Data S1 • \ 1 ORB Submittal 1212 (; 2 Building Permit Submittal 12.11 8,12 0o I < Switch hallway light < 0 light at bottom of stairs ' I I . pl „ ` s Mane Unit 701 odel 2nd L I ghting Dale Drawn by E102 scale 1,2•=1,0'