HomeMy WebLinkAboutE17-0216_plans 1_1509028152.pdf *V OF ge4 t iltillp%ire 4.7 Z Town of Va i l Stamp ' D SIG\ CONDI I I0\S D „.-C I WOIR< G \D FIFI \ \D G \. JAL L . G. \D A\ 4551R. VIA I IONS -'_iguall 1 0/26/1 7 WINTER DESIGN TEMPERATURES: INDOOR: 10 F DB SINGLE LINE DESCRIPTION DOUBLE LINE pQ OR - - GATE VALVE CO CARBON MONOXIDE SENSOR AAV AIR ADMITTANCE VALVE (STUDOR OR EQUAL) OUTDOOR: -20 F DB �/� OR CHECK VALVE C2 CARBON DIOXIDE SENSOR AFF ABOVE FINISHED FLOOR 90° ELBOW DOWN O —a OR BALL VALVE O HUMIDISTAT ABV ABOVE SUMMER DESIGN TEMPERATURES: INDOOR: N/A _i 90° ELBOW UP (, T BUTTERFLY VALVE ON D DEHUMIDISTAT BLIU BELOW N/A V —101 OR ter— PLUG VALVE N2 NITROGEN DIOXIDE SENSOR CFM CUBIC FEET PER MINUTE (AIR QUANTITY) OFFSET TO CHANGE ELEVATION ®GPM OS . I CN CAT 30 °WHEN POSSIBLE. > CIRCUIT SETTER WITH GPM OCCUPANY SENSOR (RE: ELECTRICAL) CLG CEILING ) t.� W ELEVATION 5,200 FEET > ARROW SLOPES DN. ) GLOBE VALVE PB ERV PUSH BUTTON CONTROLLER (LIGHTED) CO CLEANOUT 140111_ ' Z PT ERV PERCENT TIMER CONTROLLER (LIGHTED) CONIC CONCRETE CSN II .6 ELECTRICAL POWER AVAILABLE 120/1, 205/I, 111 \ OR STRAINER (Y-TYPE) WITH BLOW-DOWN O I I W 205/3 -----) ROUND RADIUS ELBOW u CU pc\ r ll ORS TWO-WAY AUTOMATIC CONTROL VALVE O SENSOR COTG CLEAN-OUT TO GRADE vki U1 GAS VALUE SOS BTU/CF —I>T1— OR ~ THREE-WAY AUTOMATIC DIVERTING VALVE SM SNOWMELT SENSOR (TEKMAR 09(/094) DN DOWN ilk k= I- , ---, 1- 90° STRAIGHT TEE - CC r\ 0 0 ERIE OR _ _ SOLENOID VALVE SP STATIC PRESSURE SENSOR DMPR DAMPER C) 1 A OR A PRESSURE REGULATOR (OR REDUCING VALVE) O THERMOSTAT EA EXHAUST AIR 90° CONICAL TEE 0 ��� ❑M Z TWO-WAY MODULATING CONTROL VALVE S WALL ON/OFF CONTROL SWITCH EC ELECTRICAL CONTRACTOR �,N c� > �/ � 45° BRANCH MIME © THREE-WAY MODULATING MIXING VALVE ST WALL TIMER SWITCH ER / EG EXHAUST REGISTER / EXHAUST GRILLE i X f / MIME 0 �� THERMOSTATIC MIXING VALVE (TMV) SV VARIABLE SPEED CONTROL ETR EXISTING TO REMAIN Ztu u . I� I �I DIFFERENTIAL PRESSURE VALVE EXH EXHAUST CC 1-% '� In 45° CONICAL TEE W �J J� 1_I S OR S PRESSURE RELIEF VALVE AI \ / I FCO FLOOR CLEAN-OUT li SHT IND . T MANUAL AIR VENT Y FD FIRE DAMPER OR FLOOR DRAIN SIZE OR SHAPE TRANSITION �� � I \ I I O\ Y . Z 0 X �� O AUTOMATIC AIR VENT FPC FIRE PROTECTION CONTRACTOR W 0 1i a SHEET DESCRIPTION Q VACUUM BREAKER GPM GALLONS PER MINUTE (WATER FLOW RATE) ROUND FLEXIBLE DUCT (vvv.A DM0.0 MECHANICAL COVER SHEET ORSD-{- PRESSURE GAUGE WITH GAUGE COCK SIZE (INCHES) LD SUPPLY DIFFUSER (LINEAR) ,,�,"�" ��' Ll MI.O MECHANICAL SCHEDULES \ / I Q PRESSURE SENSOR NOTE: FOR STANDARD MODULE SIZE MC MECHANICAL CONTRACTOR L!'L► 0 X 90° ELBOW DOWN j X REGISTERS, SIZE GIVEN IS NECK O M2.0 BOILER ROOM MECHANICAL PLAN / \ I T PRESSURE / TEMPERATURE TEST PORT SIZE. REFER TO AIR DEVICE SCHEDULE MOD MOTOR OPERATED DAMPER ) ( 1.ri-► 4 ; • ui SHEET FOR MODULE SIZE. 1./.1-0.- , 0 Lu M3.0 MECHANICAL SCHEMATICS I r Z _ TEMPERATURE SENSOR OA/ OSA OUTSIDE AIR 90° ELBOW UP oOr . . AIR QUANTITY (CFM) PE Stamp 6 N M4.0 MECHANICAL SPECIFICATIONS 4 SEQUENCE OF THERMOMETER WELL CA - COMB. AIR OED OPEN END DUCT ��.NNA 5 Z OPERATION DROP/ RISE DROP/ RISE I OA - OUTSIDE AIR - . IN L\,01 CO 0 OFFSET TO CHANGE ELEVATION (AT 30° I� T S 1 N THERMOMETER 12/6? CD-I 250 RA - RETURN AIR PC PLUMBING CONTRACTOR F� 1 �, 1 I > 1 WHERE POSSIBLE). ARROW IN DIRECTION EA - EXHAUST AIR V4;:I/ R .�F0 _ J J OF AIRFLOW. INDICATE DROP OR RISE. BTU METER (FLOW d TEMPERATURE DIFFERENCE) MA - MIXED AIR PR PIPE RISER i • =•• (�? MUA - MAKE-UP AIR % O O QQ FLOW METER RA RETURN AIR 30290 (� -----) ROUND RADIUS ELBOW TYPE OF AIR DEVICE. �� j p- Fs RE: SCHEDULE SHEET - ( • • ' Q FLOW SWITCH RR RETURN REGISTER ��)�O 8/4/17 ;'����� 0 RECTANGULAR ELBOW WITH �� rl [ 4 AQUASTAT RG RETURN AIR GRILLE 1 1 S�ONALE�r O A 1 S TURNING VANES \�������� z U Eli —000� OR S BRAIDED TYPE FLEXIBLE PIPE CONNECTOR I -SA SUPPLY AIR Z etO SPLIT BRANCH TAKE-OFFWITH SQUARE ELASTOMERIC PIPING ISOLATOR (WITH KEVLAR) S. DMPR SMOKE DAMPER 1U J SPLITTER DAMPER W �� I— PIPE UNION I \A I �\ SR SUPPLY REGISTER (SIDEWALL OR DUCT MOUNTED) (L/ 0O SPLIT BRANCH TAKE-OFF II QUICK CONNECT (GAS) OR NOSE BIB (WATER) SV STUDOR VENT (SIZED BY CONTRACTOR) L1-1j WITH RADIUS ELBOW 4 �p DUCTING: PIPING: SPLITTER DAMPER OR ��\ RADIANT OR SNOWMELT MANIFOLD WITH ACCESS TYP TYPICAL U J OA - OUTSIDE AIR CW - CHILLED WATER _ m 0 _1 BRANCH TAKE-OFF WITH 0 PIPE UP OR PIPE UP DOWN EA - EXHAUST AIR DW - DOMESTIC WATER TRANS TRANSITION W q Z HW - HEATING WATER RADIUS HEEL AND DAMPER GENERAL: G - GAS q C OR 0 PIPE DOWN TA TRANSFER AIR OLU E US - UTILITY SHAFT R - REFRIGERANT SD - STORM DRAIN O l'3 FLOOR DRAIN USO UNLESS NOTED OTHERWISE Z BRANCH TAKE-OFF WITH = SM - SNOWMELT FLOOR SINK US UTILITY SHAFT 1� O q AIR EXTRACTOR OD - OVERFLOW DRAIN �� WV - WASTE d VENT z ce VTR VENT THROUGH ROOF .. Ll I HORIZONTAL CLEANOUT LINED DUCTWORK O RISER NUMBER x E to (UNLESS NOTED OTHERWISE) © OR 0 FLOOR CLEAN-OUT W/ WITH Z U O I if I- SQUARE NECK CEILING DIFFUSER ® 0 METER WGO WALL CLEAN-OUT PCI UjX 4-WAY DIRECTIONAL THROW w Z UNLESS INDICATED OTHERWISE A I M (\A L ,-\ I T XFER TRANSFER Z ROUND NECK CEILING DIFFUSER F I F I\ D H S I G\4 T I O\S W ,,� �- -e- 4-WAY I \ I I \ \ / Zth• ti) UNLESS DINDICATED OTHERWISE O 4 I FVI \T 4 5 5 8 1� I A IONS U 0 CWS/R CHILLED WATER SUPPLY/RETURN 1U = SIDEWALL SUPPY GRILLE T CS/R CONDENSER WATER SUPPLY/RETURN U I ~ T OR REGISTER WITH I I NWS/R HEATING WATER SUPPLY/RETURN TERMINAL TYPE: AHU AIR HANDLING UNIT ^ W O_ I I AIR EXTRACTOR HWS/R(HT) HEATING WATER SUPPLY/RETURN HIGH TEMP CV - CONSTANT VOLUME BOX (SERIES) O 1 N FP - FAN POWERED SOX (PARALLEL) AS AIR SEPARATOR 4 ^^ -- W HWS/R(LT) HEATING WATER SUPPLY/RETURN LOW TEMP I� a J a STATIC PRESSURE CLASS VV - VARIABLE VOLUME ©®© �NGHES WATER GOREMiG�ASS CHANGE +41H SMS/R REFRIGSNOWMERANT LT SUPPLY/RETURN VR - VARIABLE VOLUME w/ REHEAT B BOILER (HOT WATER) PCI W 0 W/ 0 RS 4 RL REFRIGERANT SUCTION 4 REF. LIQUID -----DCW----- DOMESTIC COLD WATER (DCW) COOLING AIR QUANTITY (CFM) GH CHILLER > W 1- -- IW -- DOMESTIC HOT WATER (DHW) C10>1541000 MINIMUM AIR QUANTITY (CFM) FOR CG COILING COIL 1� Z " SUPPLY DUCT RISER " -----pHR— — DOMESTIC NOT WATER RECIRC (DI-1R) 1� l7 VENTILATION OR HEATING. al W Z 0 ----DI-IW-T---- DOMESTIC HOT WATER (TEMPERED) CH CABINET HEATER 1�1 111 Et PRIMARY AIR VALVE SIZE l RETURN, EXHAUST OR W WASTE _ CT COOLING TOWER CELL = (k OUTSIDE AIR DUCT RISER - - - - -V- - - - - VENT N GW GREASE WASTE CV CONSTANT VOLUME BOX CEILING RETURN AIR PW PRESSURIZED WASTE O DEF DISHWASHER EXHAUST FAN m O ��/ GRILLE OR REGISTER \.•, 4,- IW INDIRECT WASTE >IP. 1:1:1 Q BD BUILDING DRAINMOD L L G E151-1ELECTRIC BASEBOARD NEATER > q 55 BUILDING; SEWER l OY 4DOOR GRILLE SD STORM DRAIN = ECU EVAPORATIVE COOLING UNIT (L = OD OVERFLOW DRAIN (STORM) POINT OF DISCONNECTION _ EF EXHAUST FAN q SOD SEDIMENT 4 OIL DRAIN 8 POINT OF NEW CONNECTION - Issued For Z 111 0— G NATURAL GAS - ERV ENERGY RECOVERY VENTILATOR (AIR TO AIR HX)) I- 0 MANUAL BALANCING DAMPER Ell (A) ABANDON No. Date Comment U MPG MEDIUM PRESSURE NATURAL GAS _.LPG PROPANE GAS (D) DEMO ET EXPANSION TANK 1 1/19/I1 COORDINATION D D D DRAIN FC FAN COIL 2 S/4/11 PERMIT O Z MOTORIZED DAMPER 046 (E) EXISTING CD CONDENSATE DRAIN FP FAN POWERED BOX a 0 F FIRE SPRINKLER (F) FUTURE - 3 E CA COMPRESSED AIR (N) NEW GF GLYCOL FEEDER 0 SMOKE DAMPER fjo GEO GEOEXCHANGE SOURCE - Z U (R) RELOCATE HC HEATING COIL q lu SWS/R SOLAR WATER SUPPLY/RETURN _ _• a (E) EXISTING HP HEAT PUMP MECHANICAL } ® FIRE DAMPER - (UG) UNDERGROUND HX NEAT EXCHANGER COVER SHEET 1FN Z ® COMBINATION FIRE AND SMOKE DAMPER - H HUMIDIFIER O iV Z F/S F/S KEF KITCHEN EXHAUST FAN lv >- (Y INLINE WET ROTOR PUMP IL -j UI Z c0 Z CEILING RADIATION DAMPER I . [®I INLINE WET ROTOR PUMP (W/ INTEGRAL CHECK) -MV MIXING VALVE O LI-1 P PUMP (SEE PIPING LEGEND FOR DETAILS) .4 ° w GRAVITY BACKDRAFT DAMPER Di —Dip— INLINE CLOSE-COUPLED PUMP RF RETURN/RELIEF AIR FAN X Q U 0 SF SUPPLY FAN Project No. Scale: Z q(k BASE MOUNTED END SUCTION PUMP 11051.00 N/A O 0 DUCT MOUNTED SMOKE DETECTOR ,p TEF TOILET EXHAUST FAN 0 Z — \ / TMV THERMOSTATIC MIXING VALVE Drawn By: Checked By: 4 w 0 LU \ / CEILING ACCESS PANEL \ / JSW JDR 00 1 d) Z a \ v I \ v 1 UH UNIT HEATER VV VARIABLE VOLUME SOX q W >- VR VARIABLE VOLUME BOX W/ REHEAT INiJ(:) •O U U1 0 WALL CAP - BATH OR DRYER EXHAUST )- 0 U WITH INTEGRAL BACKDRAFT DAMPER WH WATER HEATER Q OU