HomeMy WebLinkAboutproduct data.pdfGE Security Overview The NetworX NX-8E is a full-featured security system that uses advanced technology for burglary, fire and environmental detection. The NX-8E is a flexible security system that is both easy to install and simple to use. With eight partitions and up to 192 zones, the NX-8E can handle your most demanding commercial and residential security needs. Outstanding features The NX-8E panel comes standard with eight hardwire zone inputs and two relays. Four programmable outputs can be set up to activate external devices during an alarm or other system event. The modular design allows for complete integration of multiple systems within one enclosure. Adding more zones or expanding capability is fast and easy. Convenient and flexible Conduct quick and easy on-site programming with alphanumeric keypads and a menu-driven text interface. Off-site programming is also available with the DL-900 software for Windows. NetworX Control Panel NX-8E Standard features • Expandable to 192 fully programmable hardwire and/or wireless zones • 240 user codes • Up to 192 addressable devices can be used • 512-event history log that provides date, time, event and user number • Up to 8 true partitions with separate account codes, entry/exit delays, and feature selections for each partition • Maximum of 32 keypads with up to 8 per partition • Wireless technology with up to 192 supervised zones • 2-wire or 4-wire smoke detector compability • Fire alarm verification for greater false alarm immunity • Dynamic battery test • Standard RS-232 on-board interface GE Security © 2005 GE Security. NetworX is a trademark of GE Security All other trademarks are properties of their owners. 466-2134-KA-0105 12345 SW Leveton Drive Tualatin, OR 97062 Phone: 503-692-4052 USA & Canada: 800-547-2556 www.gesecurity.com Specifications •Operating Power – 16.5V AC 40VA •Auxiliary w/40VA or 50VA transformer – 2 Amp •Auxiliary w/NX-320E power supply – 3 Amps* Loop resistance •For standard loop – 300Ω Maximum •For 2-wire smokes – 30Ω Maximum Operating temperature •32° to 120°F Dimensions •6.40 inches wide •4.0 inches high •1.10 inches deep Shipping weight •9 pounds * When using the NX-320E (w/50VA transformer) rated at 2 Amps and NX-8E (w/40VA or 50VA transformer) rated at 1 Amp, the combined available power is 3 Amps. imagination at work NetworX Control Panel NX-8E LED with Removable Door Fixed Display with Removable Door LED with Removable Door LCD with Removable Door Available Keypad Styles Customer Service and Technical Support: 1-888-GE Security (437-3287) GE Security The NX-148E-RF is an integrated 48-zone wireless receiver LCD keypad with traditional design and an easy-to-read, customizable display. It is compatible with all NetworX control panels (except commercial fire). The NX-148E-RF offers the convenience of having an integrated wireless receiver built into the keypad along with standard hardwire features. A removable door allows the user to swing the door down or simply take it off for use. The NX-148E-RF emergency keys are highlighted on the keypad and can be programmed to contact and send complete information to a responding police, fire or EMS unit with just one touch. There are also five pre-programmed touch keys that allow the most common functions to be performed with ease. All keys on the NX-148E-RF are backlit to ensure error-free operation — even in a dark room. The NX-148E-RF is cost-effective and easy to install. Designed for functionality and compatibility, the NX- 148E-RF is the right keypad to fit any application. Features • Integrated 48-zone wireless receiver • Optimize wireless reception by having the keypad/receiver in the best location • LCD, easy-to-read programmable display • Traditional design to go with any decor • Compatible with all NetworX series control panels (except commercial fire) • Easy to install, program and maintain NetworX NX-148E-RF touchpad NetworX NX-148E-RF wireless LCD display keypad Americas 503-885-5700 888-GE-SECURITY (437-3287) faxback 800-483-2495 info@gesecurity.com www.gesecurity.com Asia tel 852-2907-8108 fax 852-2142-5063 Australia tel 61-3-9259-4700 fax 61-3-9259-4799 Europe tel 32-2-725-11-20 fax 32-2-721-86-13 Latin America tel 305-593-4301 fax 305-593-4300 © 2006 GE Security. As a company of innovation, GE Security reserves the right to change product specifications without notice. For the latest product specifications, visit GE Security online at www.GESecurity.com or contact your GE Security sales representative. 20060322_DS_nx-148e-rf_466-70.B Electrical • Current: 75 to 110 mA nominal Environmental • Operating temperature: 32 to 120°F (0 to 49°C) Physical • Dimensions (HxWxD): 5.30 x 6.20 x 1.30 in. (135 x 157 x 33 mm) • Construction: ABS plastic • Color: White Specifications Ordering information NX-148E-RF NetworX 48-zone LCD display keypad with door and integrated wireless receiver PinPoint Addressable Point ID Systems www.GE-Interlogix.com GE Interlogix Product Information Standard Features Single two-wire loop up to two miles means fast and easy installation for new construction or retrofit applications Addressable sensors indicates exact location of alarm or trouble event Supports up to 192 devices Advanced digital communication from the sensors to the panel GE Interlogix — a name you know and trust Supports 3 Class B loops The PinPoint addressable solutions bring together NetworX NX-8E functionality with the reliability of GE Interlogix sensors. Supporting up to 192 devices on a single two-wire loop up to two miles, the PinPoint point ID solution can be installed fast in new construction or retrofit applications. Overview Components NetworX NX-8E Part # NX-8E 4 Input 4 Output Device Part # 4I4O-ID Single Input Device Part # SI-ID ShatterPro® Glassbreak Part # 5845-ID AP Series Motion Sensor Part # AP750-ID PinPoint Interface Card Part # NX-2192E PinPoint Addressable Point ID Systems Description An addressable PIR for use with the NX-2192E Pinpoint ID Bus Interface. Adaptive Single Processing – 3D signal processing with gliding focus mirror optics analyzes size, speed, shape and adaptive alarm threshold. Provides four separate curtain coverage patterns with 50' (15.2 m) range. Flat wall or corner mounting height up to 10' (3m). Ships with two plastic inserts, each covering half the coverage pattern for more flexible mounting options (center curtain always active). Specifications Housing Material Flame retardant ABS Operating voltage 8 to 27V (as supplied by NX-2192E) Current draw 250 µA typical avg. 3mA with LED momentarily on Transmit condition Alarm, tamper Detection range 50 ft (15.2m) Mounting height 6 to 10 ft (1.8 to 3m) Number of curtains 7 Operating temperature 32° to 131°F (0° to 55°C) Relative humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 2.9' (74mm) Depth 2.2' (56mm) Height 5.1' (129mm) Listings UL 639, FCC Features AP750-ID Addressable PIR 45° Left 45° Right 50'15.2m 10'3.0m 4.8' 1.4m Coverage Patterns Description An addressable ShatterPro® II glassbreak for use with the NX-2192E PinPoint ID Bus Interface. ShatterPro's Pattern Recognition Technology™for superior detection and false alarm immunity. Protects all glass types up to a standard thickness of 1/4" (6.4 mm) including plate, wired, tempered and laminated glass. Senses through light blinds and unlined drapes. Suitable for use in occupied areas on the perimeter loop. Specifications Housing material Flame retardant ABS Operating voltage 8 to 27V (as supplied by NX 2192) Current draw 250 µA typical avg. 3mA with LED momentarily on Microphone Omni-directional electret Operating temperature 14° to 120°F (-10° to 50°C) Relative humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 3.13' (80mm) Depth 1.7' (43mm) Height 4.2' (108mm) Listings FCC Features 5845-ID Addressable Shatterpro® Glassbreak 20' (6m) max. Ceiling mount Wall mount 20' (6m)max. Description An addressable single input interface to connect a single non-addressable device to the NX-2192E PinPoint ID bus interface. Supports a single non-addressable device. Utilizes advanced digital data communications protocol that ensures the integrity of the data communication. Specifications Housing material Flame retardant ABS Operating voltage 8 to 27V (as supplied by NX-2192E) Signaling voltage 4 to 9V Current draw 250 µA Operating temperature 32° to 131°F (0° to 55°C) Relative humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 3.3' (84mm) Depth 1.3' (33mm) Height 2.8' (71mm) Listings UL 365, UL 609, UL 985, UL 1023, UL 1610, FCC Features SI-ID Single Input Device Description An addressable 4 input and 4 unsupervised output interface that allows you to connect up to 4 non-addressable devices to the NX-2192E PinPoint ID Bus Interface. Supports four inputs and four unsupervised outputs (horns, bells, sirens, etc.). Utilizes advanced digital data communications protocol that ensures the integrity of the data communication. Specifications Housing material Flame retardant ABS Operating voltage 12 to 30VDC Signaling voltage 4 to 9V Current draw 100 µA (bus loading) Output current 500mA maximum each Operating temperature 32° to 131°F (0° to 55°C) Relative Humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 6.8' (173mm) Depth 2.0' (51mm) Height 4.8' (122mm) Listings UL 365, UL 609, UL 985, UL 1023, UL 1610, FCC Features 4I4O-ID Four Input Four Output Device From PinPoint loop To single non-addressable device, such as a magnetic contact Open Single EOL Double EOL Short >1MΩ 47k±5% 94k±5% >20Ω Input Loop Resistance Reported to panel (47k EOL included) Addressable Inputs To unsupervised outputs, such as horns and sirens Open Single EOL Double EOL Short >1MΩ 47k±5% 94k±5% >20Ω Input Loop Resistance Reported to panel (47k EOL included) PinPoint Addressable Point ID Systems ©2003 GE Interlogix. Smoke! in a Can is a trademark of GE Interlogix. All trademarks are properties of their owners. M-4301-XXXXKA-0103 GE Interlogix www.GE-Interlogix.com 2266 Second Street North North St. Paul, MN 55109 Phone: 651-777-2690 USA & Canada: 800-777-5484 Technical Service: 800-777-2624 12345 SW Leveton Drive Tualatin, OR 97062 Phone: 503-692-4052 USA & Canada: 800-547-2556 Technical Service: 800-648-7424 Faxback: 800-483-2495 NetworX NX-8E control panel PinPoint interface card Ge interlogix PIR Ge interlogix glassbreak Single input device 4 input 4 output device NX-8E NX-2192E AP750-ID 5845-ID SI-ID 4I4O-ID Ordering Information – – White White White White Specifications Current Draw 170 mA standby maximum Operating temperature 32° to 122°F (0° to 50°C) Shipping Weight 0.5 lb. Dimensions Width 2' (51mm) Depth 1.25' (32mm) Height 9' (229mm) Features NX-2192E Description Point ID Bus Interface Card. Attaches to the NX-8E control panel. Bus interface that supports up to 192 addressable devices on a two-mile loop. Supports three class B loops. UL UL UL FCC UL UL Model Description Listing Approvals PinPoint Addressable Point ID Systems Agency Listings Smoke Detectors with Sounder and Relay Option System Sensor i3™ sounder and relay smoke detectors apply the guiding principles of installation ease, intelligence, and instant inspection in a series of specialty conventional devices. Features • 85 dB sounder • Form C relay • Isolated thermal sensor • Plug-in design (base included) • In-line terminals • Flexible mounting options • Stop-Drop ’N Lock™ attachment to the base • Removable cover and chamber • Remote maintenance signaling • Drift compensation and smoothing algorithms • Simplified sensitivity measurement • Dual-color LEDs Installation ease. Throughout the i3 series, installation is simple with its installer-friendly base and plug-in design. The base accommodates a broad range of back box and direct mounting options and provides ample space for pre-wiring the device. To complete the installation, the i3 detector plugs into its base with a simple Stop-Drop ’N Lock action. Intelligence. To reduce the likelihood of nuisance alarms, all i3 detectors are equipped with both drift compensation and smoothing algorithms. These capabilities minimize both short- and long-term causes of nuisance alarms, such as RF interference and dust accumulation. When connected to the 2W-MOD2 loop test/ maintenance module or an i3 Ready™ panel, 2-wire i3 detectors can generate a remote maintenance signal when in a maintenance or freeze trouble condition. To measure the sensitivity of any i3 detector, the SENS-RDR displays the reading, in terms of percent-per-foot obscuration, within seconds. Instant inspection. i3 has red and green LEDs to simplify local status indication during power-up, standby, alarm, maintenance, and freeze trouble conditions. When in alarm, i3 sounder models generate an 85 dB temporal tone. If connected to the RRS-MOD reversing relay/synchronization module, all i3 sounders on the loop will activate when one detector is in alarm. The RRS-MOD also synchronizes i3 sounder output to ensure a clear audible signal. Should the application call for differentiating between a local and a general alarm, the i3 line offers an isolated thermal model, which initiates a local alarm when smoke is detected, and a general alarm when the thermal sensor is activated. 2133372-02-E7272-1653:1643015195S911 3180932 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2009 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.A05-0348-004 • 6/09 • #2170 Ordering Information Model Thermal Wiring Alarm Current 2WTA-B Yes 2-wire 130 mA max. limited by control panel 2WTR-B Yes 2-wire 130 mA max. limited by control panel 4WTA-B Yes 4-wire 35 mA 4WTR-B Yes 4-wire 35 mA 4WTAR-B Yes 4-wire 50 mA 4WITAR-B Yes 4-wire 50 mA Smoke Detector Specifications Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized 2-wire: 8.5 V to 35 V 4-wire: 10 V to 35 V Maximum Ripple Voltage 30% of applied voltage (peak to peak) Standby Current 2-wire: 50 µA maximum average 4-wire: 50 µA maximum average Peak Standby Current 2-wire: 100 µA 4-wire: n/a Maximum Alarm Current 2-wire: 2WTR-B: 130 mA limited by control panel 2WTA-B: 130 mA** 4-wire: 4WTA-B, 4WTR-B: 35 mA 4WTAR-B, 4WITAR-B: 50 mA **Direct Power (Non-Reverse Polarity): 130 mA limited by panel. Reverse Polarity Power: 30 mA for the 2WTA-B in alarm; 12 mA for all other 2WTA-B units on the loop. Add 25 mA for the RRS-MOD reversing relay alarm current. Alarm Contact Ratings 2-wire: n/a 4-wire: 0.5 A @ 30 V AC/DC Form C Contact Ratings 2 A @ 30 V AC/DC Physical Specifications Operating Temperature Range 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 41°F (5°C) Sensitivity 2.5%/ft. nominal Input Terminals 14–22 AWG Dimensions (including base) 5.3 inches (134 mm) diameter, 2.0 inches (51 mm) height Approximate Weight 7.1 oz (200 g) Sound Pressure Output 85 dBA (models 2WTA-B, 4WTA-B, 4WTAR-B, and 4WITAR-B only) Mounting 3½-inch octagonal back box, 4-inch octagonal back box, single-gang back box, 4-inch square back box with a plaster ring, direct mount to ceiling LED Modes LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Power-Up Sequence for LED Indication Condition Duration Initial LED status indication 80 seconds Architect/Engineer Specifications Smoke detector shall be a System Sensor i3 Series model number_______, listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a combination photoelectric/thermal equipped with a sounder (model 2WTA-B, 4WTA-B), a Form C relay (model 2WTR-B), a combination sounder/relay (model 4WTAR-B), or an isolated thermal/sounder/relay (model 4WITAR-B). The detector shall include a mounting base for mounting to 3½-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power-up, normal standby, out of sensitivity, alarm, and freeze trouble conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. When used in conjunction with the RRS-MOD module, all i3 sounder models on a loop shall sound when one sounder alarms, all shall be synchronized, and all sounders may be silenced from the panel. Model Description RRS-MOD Reversing relay/synchronization module 2W-MOD2 2-wire loop test/maintenance module SENS-RDR Sensitivity reader RT Removal/replacement tool A77-AB2 Retrofit adapter bracket i4 Series Combination CO/Photoelectric Smoke Detector Best-in-class carbon monoxide (CO) and smoke detection technology in a single, system-connected device. Features • Single device for CO and smoke detection that uses less wiring and fewer junction boxes • Compatible with a wide range of control panels with the use of the required i4 Interface Module. • Sends distinct smoke and CO signals to the panel • Sounds Temporal 3 for smoke and Temporal 4 for CO • Built-in 85dB sounder • LEDs display both CO and smoke status • External IR LED provides extended range sensitivity testing • Versatile mounting allows for wall or ceiling placement • Easily replaceable electrochemical CO cell with 6-year end-of-life timer that signals the panel and chirps to alert the homeowner • RealTest® enables functional test using canned CO • Drift compensation and smoothing algorithms provide false alarm immunity • Compatible with SENS-RDR sensitivity tester • Full agency compliance with UL 268 and UL 2075 Integration: The i4 Series combines CO and smoke detection into one device, requiring less wiring and fewer back boxes than two separate devices. The i4 Series is compatible with i3 (2WTA-B or 4WTA-B), so an attractive CO monitoring solution can easily be retrofitted into existing i3 installations. The i4 Series CO cell can be easily replaced at end-of-life, resulting in a much lower life cost than having to replace the entire detector. Installation ease: The i4 Series Combination CO/Smoke detector requires less wiring than two separate CO and smoke devices. Installers can pre-wire its plug-in base, while its large wire-entry port and in-line terminals provide ample room for neatly routing wiring. The base accommodates several back box options and also direct mounts using drywall anchors. The i4 head plugs into the base with a simple Stop-Drop `N Lock™ action. When the detector’s CO cell reaches end- of-life, it can be easily replaced in the field without a tool. Intelligence: With the help of the module, the i4 Series transmits distinct CO and smoke signals, allowing appropriate response from the central monitoring station. Intelligent features, such as drift compensation and smoothing algorithms, reduce nuisance alarms. Instant inspection: The i4 Series LEDs enable instant inspection of detector status signaling normal/standby condition, alarm condition, maintenance/trouble condition or functional test mode. 2-wire devices allow loop testing via the EZ Walk feature where wiring can easily be verified by checking the LED status at each detector. Smoke sensitivity can be easily measured using the wireless SENS- RDR device. CO cell functionality can also be quickly validated in the field with canned CO per NFPA 720: 2009 requirements using the detector’s RealTest functionality. 4 Agency Listings S268 7272-1653:0203 Physical Specifications Dimension:Diameter: 5.5˝; Depth: 2.5˝ (includes base) Weight:9.2 oz. (261 g) Operating Temperature Range:0 – 50° C (32 – 122° F) Operating Humidity Range:20-95% RH Storage Temperature Range:-10 – 70° C (14 – 158° F) Sensitivity:2.5%/ft nominal Input Terminals:14 to 22 AWG Mounting:Back boxes: 3.5˝ and 4˝ Octagonal; Single-gang; 4˝ Square; 2 x 4˝, 3.5˝ and 4˝ round ceiling. Direct mount to wall or ceiling. Electrical Specifications Operating Voltage (VDC):Nominal: 12/24; Minimum: 8.5; Maximum: 35 Maximum Standby Current:50 µA Maximum Alarm Current:2-Wire 50mA; 4-Wire 40mA Audible Signal:85 dBA Maximum Reverse Polarity Current:20 mA Maximum Start-up Current:200mA Maximum Start-up Capacitance:.10 µF Operation Modes / LED Status Green Red Blue Sounder Alarm Smoke:Off On Off Temp 3 Alarm CO:Off Off On Temp 4 Alarm Smoke & CO:Off On On Temp 3 Power Up:Blink 5 sec.Blink 5 sec Blink 5 sec.Off Standby:Blink 5 sec.Off Off Off RealTest® Mode (CO):Off Off Blink 1 sec.Off After CO is Sprayed:Off Off On Temp 4 Smoke Maintenance:Off Blink 5 sec.Off Off CO Trouble:Off Off Blink 5 sec.Off End-of-Life:Off Off Blink 5 sec.Intermittent i4 Series Combination CO/Smoke Detector Specifications Carbon monoxide (CO)/Smoke detector shall be a System Sensor model number COSMO-2W (2-Wire) / COSMO-4W (4-Wire) listed to UL 268 for Fire Protection Signaling Systems and to UL 2075 for Carbon Monoxide Gas Detection. The detector shall be photoelectric smoke sensing and electrochemical CO sensing and equipped with a sounder capable of Temp 3 and Temp 4 audible signals. The detector shall have nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface mount) to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide LED indication that blinks to indicate normal standby, smoke alarm, smoke maintenance, CO alarm, CO trouble/end-of-life. When the detector is in CO trouble condition, it shall send a trouble signal to the panel. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. The 2-wire model shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. The detector shall have a replaceable CO cell that can be replaced at end of cell life. Features • Easily integrates up to 12 compatible detectors to a wide range of control panels • Sends distinct smoke and CO signals from i4 detectors to the panel • LED indication shows when a detector on the loop requires cleaning or maintenance (2-wire detectors only) • Initiates the EZ Walk loop test (2-wire detectors only) i4 Series Interface Module The i4 Interface Module connects up to 12 detectors to a wide range of control panels using only 2 to 3 zones. Integration: The i4 module allows up to 12 i4 Series or compatible i3 Series smoke detector models to be integrated into a fire alarm panel using only 2 to 3 zones: a smoke zone, a CO zone and an optional trouble zone. Detectors sound Temp 3 for smoke and Temp 4 for CO events. The i4 module can be used to alarm all sounders in compatible detectors for smoke and CO events. When one detector detects smoke or CO and goes into alarm, all connected detectors alarm, offering the highest level of warning to the homeowner. Installation ease: The i4 Series Interface Module mounts to a 411/16-inch square back box for quick and easy installation. Terminal blocks with durable SEMS screws ensure a reliable connection. It also has pre-drilled holes for easy mounting inside a metal enclosure Intelligence: The i4 Interface Module allows i4 and compatible i3 smoke detector models (2WTA-B and 4WTA-B) to communicate with any listed fire alarm control panel capable of utilizing this module. Instant inspection: The i4 Interface Module provides LED status indication for the loop, displaying normal operation, loop wiring fault, smoke events, smoke maintenance (2-wire only), CO events, and CO maintenance/end-of-life. Agency Listings S911 7272-1653:0203 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2013 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. SCDS00201 • 03/13 Ordering Information Part No.Description COSMO-2W 12/24 volt, 2-wire, system-connected, combination carbon monoxide/smoke detector with RealTest technology COSMO-4W 12/24 volt, 4-wire, system-connected, combination carbon monoxide/smoke detector with RealTest technology COSMOD2W 2-wire interface module (required to use with COSMO-2W models) COSMOD4W 4-wire interface module (required to use with COSMO-4W models) CO-REPL Replacement CO cell for COSMO-2W and COSMO-4W models SENS-RDR Sensitivity reader EOLR-1 End-of-line relay (required with 4-wire systems) Module Power-Up Sequence / LED Status Condition Duration Maintenance/Freeze trouble LED indication 6 minutes EZ Walk test available 6 minutes after power up or panel reset Operation Modes / LED Status Green Yellow Red Blue Alarm Smoke:Blink 5 sec.Off On Off Alarm CO:Blink 5 sec.Off Off On Alarm Smoke & CO:Blink 5 sec.Off On On No power / No communication:Off Off Off Off Loop wiring fault:Blink 5 sec.On Off Off EZ Walk Test Mode (2-wire only):Blink 5 sec.Blink 5 sec Off Off Smoke Maintenance (2-wire only):Blink 5 sec.Off Blink 5 sec Off Smoke Freeze Trouble (i3 2WTA-B only):Blink 5 sec.Off Blink 10 sec Off CO Trouble:Blink 5 sec.Off Off Blink 5 sec. Electrical Specifications Module Operating Voltage (VDC):Nom.: 12/24; Min.: 8.5 (2-wire), 10 (4-wire, power limited); Max.: 35 VDC (power limited) Standby Current:2-Wire: 62mA (max.), 45mA (12V In), 27mA (24V In); 4-Wire: 52mA1 (max.), 36mA1 (12V In), 20mA1 (24V In) Alarm Current2:2-Wire: 174mA (max.), 116mA (12V In), 60mA (24V In); 4-Wire: 75mA1 (max.), 54mA1 (12V In), 32mA1 (24V In) Maximum Ripple Voltage:30% of applied power Maximum Alarm Threshold:9.2 Volts DC Alarm and Maintenance Contact Rating:100 mA @ 36 Volts DC, resistive, 25 ohms Maximum Loop Wiring Resistance: 2-Wire 50 Ohms; 4-Wire 300 Ohms Trigger inputs:Min On Voltage: 1.5V; Max.: Vin 1 Does not include current draw from attached detectors or EOL relay. 2 Does not include reverse polarity current draw from attached detectors. i4 Series Interface Module Specifications The i4 module shall be a System Sensor i4 Series model number COSMOD2W (2-wire) or COSMOD4W (4-wire) listed to UL 864 and UL 985 for Control Units for Fire Protection Signaling Systems. The module shall include provisions for mounting to 4-inch square back box. Wiring connections shall be made by means of SEMS screws. The module shall provide 4 LED indicators that blink or illuminate to indicate communication status, maintenance alert, alarm or freeze trouble conditions, and EZ Walk loop test mode (2-wire module only). The module shall allow communication to i4 Series and i3 Series detectors with any UL 864- and UL 985-listed fire alarm control panel capable of utilizing this module. The 2-wire module shall offer provisions for Style D wiring on IDC loops and shall provide a loop testing capability (EZ Walk) to verify the initiating loop wiring. Physical Specifications Module Dimension:Height: 6.04˝; Width: 6.04˝; Depth: 1.00˝ Weight:9.6 oz. 272 (g) Operating Temperature Range:0 – 50° C (32 – 122° F) Operating Humidity Range:5 - 95% RH Storage Temperature Range:-20 – 70° C (-4 – 158° F) Input Terminals:14 to 22 AWG Mounting:411/16˝ square back box or inside a metal enclosure