A15-0080 DATA SHEETS.pdf
DF-52013:D • 4/13/2012 — Page 1 of 2 BG-12LX Addressable Manual Pull Station Addressable Devices DF-52013:D • E-100 FLPullStation.jpgGeneral The Fire·Lite BG-12LX is a state-of-the-art, dual-action (i.e.,requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire·Lite’s addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word “ACTIVATED” appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm² wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide-lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonatematerial with a textured finish. Specifications •Shipping Weight: 9.6 oz. (272.15 g) •Normal operating voltage: 24 VDC. •Maximum SLC loop voltage: 28.0 VDC. •Maximum SLC standby current: 375 μA. •Maximum SLC alarm current: 5 mA. •Temperature Range: 32°F to 120°F (0°C to 49°C) •Relative Humidity: 10% to 93% (noncondensing) •For use indoors in a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word “ACTI- VATED” (in bright yellow) appears at the top of the handle,while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 – 159 with Breakaway Tab removed for MS-9600 Series, 1 – 99 and MS-9200UDLS, 1 – 50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shallappear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flushmounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed Page 2 of 2 — DF-52013:D • 4/13/2012 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105.www.firelite.com FireLite® Alarms® is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Made in the U.S. A. within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provideaddress setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro-cess. Consult factory for latest listing status. •UL/ULC Listed: S711 (listed for Canadian and non-Cana- dian applications). •MEA: 67-02-E. •CSFM: 7150-0075:0184. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. DF-52385:D • 5/17/2013 — Page 1 of 2 H355(A) Series Intelligent Addressable Thermal Detectors Addressable Devices DF-52385:D • E-710 General The Fire•Lite Alarms H355(A) Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response. These sensors provide open- area protection and are intended for use with Fire•Lite’s addressable Fire Alarm Control Panels (FACPs). The H355(A) and H355R(A) sensors provide fixed tempera- ture alarm detection at 135°F (57°C). The H355R(A) sensor also responds to rate-of-rise conditions of greater than 15°F (8.3°C) per minute. The H355HT(A) is a fixed high-tempera- ture detector that activates at 190°F (88°C). These thermal detectors provide addressable property protection in a variety of applications. Two LEDs on each sensor light to provide a local, visible sen- sor indication. Remote LED annunciator capability is available using an optional accessory, the RA100Z. Features SLC loop: • Two-wire SLC loop connection. • Unit uses base for wiring. Addressing: • Addressable by device. • Rotary, decimal addressing: 01 – 159 with MS-9600 series, 01 – 99 with MS-9200 series. Architecture: • Sleek, low-profile, stylish design. • State-of-the-art thermistor technology for fast response. • Integral communications and built-in device-type identifica- tion. • Built-in tamper resistant feature. • Built-in functional test switch activated by external magnet. Operation: • Factory preset at 135°F (57°C) for the H355(A) and H355R(A); 190°F (88°C) for the H355HT(A). • Rate-of-rise triggers at 15°F (8.3°C) per minute for the H355R(A). • 360°-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink red in Normal condition and turn on steady red in Alarm. • Visible LEDs “blink” every time the unit is addressed. Mechanicals: • Sealed against back pressure. • SEMS screws for wiring of the separate base. • Designed for direct-surface or electrical-box mounting. • Plugs into separate base for ease of installation and main- tenance. • Separate base allows interchange of photoelectric, ioniza- tion and thermal sensors. Other system features: • Remote test feature from the panel. • Walk test with address display. • Low standby current. • 94-5V plastic flammability rating. Options: • Remote LED output connection to optional RA100Z remote LED annunciator. • Flanged surface mounting kit. Installation H355(A) Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and mainte- nance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring only. Applications Use thermal detectors for protection of property. Construction These detectors are constructed of off-white fire-resistant plastic. The H355(A) Series plug-in intelligent thermal detec- tors are designed to commercial standards and offer an attrac-tive appearance. Operation Each H355(A) Series detector uses one of 159 (MS-9600 series) or 99 (MS-9200 series) possible addresses on a con- trol panel SLC loop. It responds to regular polls from the con- trol panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimu- lates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The H355(A) Series offers features and performance that represent the latest in thermal detector technology. H355(A) in B210LP(A) Base B210-2251.jpg Page 2 of 2 — DF-52385:D • 5/17/2013 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105.www.firelite.com Fire•Lite® Alarms is a registered trademark of Honeywell International Inc. ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Made in the U.S. A. Spefications Size: 2.1" (5.3 cm) high; base determines diameter. – B210LP(A): 6.1" (15.5 cm) diameter. – B501(A): 4.1" (10.4 cm) diameter. – B200SR(A): 6.875" (17.46 cm) diameter. – B224RB(A): 6.2" (15.748 cm) diameter. Shipping weight: 4.8 oz. (137 g). Installation temperature: –H355(A), H355R(A): –4°F to 100°F (–20°C to 38°C). –H355HT(A): –4°F to 150°F (–20°C to 66°C). Humidity range: 10% to 93% relative humidity (noncon- densing). Voltage range: 15 to 32 VDC peak. Standby current: 300 μA @ 24 VDC (one communication every five seconds with LED blink enabled). LED current: 6.5 mA @ 24 VDC. Mounting: B210LP(A) flanged base, included. See “Product Line Information: Intelligent Bases” if using a different base. Fixed-temperature setpoint: 135°F (57°C) for the H355(A) and H355R(A); 190°F (88°C) for the H355HT(A). Rate-of-rise detection: responds to greater than 15°F (8.3°C) per minute. Listings and Approvals Listings and approvals below apply to the H355(A) Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S2517. •ULC Listed (models H355A, H355RA, H355HTA). •CSFM approved: 7270-0075:0195. •FM approved. Product Line Information NOTE: “A” suffix indicates ULC Listed model. H355: Intelligent thermal sensor; 135° F (57° C); B210LP base included. H355A: Same as H355 but with ULC Listing; B210LPA base included. H355R: Same as H355 with rate-of-rise feature; B210LP base included. H355RA: Same as H355R but with ULC Listing; B210LPA base included. H355HT: Intelligent fixed high-temperature thermal detector; 190° F (88° C); B210LP base included. H355HTA: Same as H355HT but with ULC Listing; B210LPA base included. INTELLIGENT BASES NOTE: “A” suffix indicates ULC Listed model. NOTE: The detector’s plug-in base can be changed off for special applications. For details about intelligent bases and their mount- ing, see DF-60059. B210LP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A): Standard European flangeless mounting base. B501BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm²). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224BI(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). ACCESSORIES F110: Retrofit flange to convert B210LP(A) to match the B350LP(A) profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B210LP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. DF-52384:D • 2/11/2015 — Page 1 of 2 SD355(A) Series Addressable Photoelectric Smoke Detectors Addressable Devices DF-52384:D • E-160 General The SD355(A), SD355T(A), and SD355R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the- art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire•Lite’s Addressable Fire Alarm Control Panels (FACPs). The SD355T(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indica- tion. Remote LED annunciator capability is available as an optional accessory, PN RA100Z(A). The SD355R(A) is a remote test capable detector for use with D355PL(A) or DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP • Two-wire loop connection. • Unit uses base for wiring. ADDRESSING • Addressable by device. • Rotary, decimal addressing: 01 – 99 with MS-9200UD(LS), and 01 – 159 with MS-9600UD(LS). ARCHITECTURE • Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. • Sleek, low-profile design. • Integral communications and built-in type identification. • Built-in tamper-resistant feature. • Removable cover and insect-resistant screen for simple field cleaning. OPERATION • Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. • Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. • Visible LED “blinks” when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. MECHANICALS • Sealed against back pressure. • Direct surface mounting or electrical box mounting. • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring — included). OTHER SYSTEM FEATURES • Fully coated circuit boards and superior RF/transient pro- tection. • 94-V0 plastic flammability rating. • Low standby current. OPTIONS • Remote LED output connection, PN RA100Z(A). Applications Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white fire resistant plas- tic. SD355(A) series plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation SD355(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class B) wiring. SD355R(A) mounts in a D355PL(A) or DNR(A)/DNRW duct detector housing. Operation Each SD355(A) series detector uses one of 99 possible addresses on the MS-9200UD(LS) and up to 318 (159 on each loop) on the MS-9600UD(LS) Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The addressable photoelectric sensor in the SD355(A) series has a unique unipolar chamber that responds quickly and uni- formly to a broad range of smoke conditions. It can withstand wind gusts up to 4,000 feet-per-minute (20 m/sec.) without sending an alarm level signal. Because of its unipolar cham- ber, the SD355(A) series is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. SD355(A) in B210LP(A) Base 2151_2251B_CEILING.png Page 2 of 2 — DF-52384:D • 2/11/2015 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com FireLite® Alarms is a registered trademark of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a MS-9200UD(LS) or MS- 9600UD(LS) addressable fire alarm control panel. The results of the sensitivity test can be printed off the MS-9200UD(LS) or MS-9600UD(LS) for record keeping. Specification Voltage range: 15 – 32 VDC (peak). Standby current: 300 µA @ 24 VDC. LED current: 6.5 mA @ 24 VDC (latched “ON”). Air velocity: 4,000 ft./min. (20 m/sec.) maximum. Size: 2.1" (5.33 cm) high; base determines diameter. – B210LP(A): 6.1" (15.5 cm) diameter. – B501(A): 4.1" (10.4 cm) diameter. – B200SR(A): 6.875" (17.46 cm) diameter. – B224RB(A): 6.2" (15.748 cm) diameter. Weight: 3.6 oz. (102 g). Operating temperature range: for SD355(A): 0°C to 49°C (32°F to 120°F); for SD355T(A): 0°C to 38°C (32°F to 100°F). SD355R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Temperature: 0°C – 49°C (32°F – 120°F). Relative humidity: 10% – 93%, non-condensing. Listings Listings and approvals below apply to the SD355(A), SD355T(A), and SD355RT(A) detectors. In some cases, cer- tain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S1059. •ULC Listed: S1059. •CSFM: 7272-0075:0194. •MEA: 243-02-E. • FM approved. Product Line Information NOTE: “A” suffix indicates ULC Listed model. SD355: Addressable photoelectric detector; B210LP base included. SD355A: Sames as SD355 with ULC Listing; B210LPA base included. SD355T: Same as SD355 but with thermal element; B210LP base included. SD355TA: Same as SD355T with ULC Listing; B210LPA base included. SD355R: Remote test capable addressable photoelectric detector for use with a D355PL(A) or DNRA/DNRW duct detector housing; B210LP base included. SD355RA: Same as SD355R with ULC Listing for use with a D355PLA or DNRA duct detector housing; B210LPA base included. INTELLIGENT BASES NOTE: “A” suffix indicates ULC Listed model. NOTE: The detector’s plug-in base can be changed off for special applications. For details about intelligent bases and their mount- ing, see DF-60059. B210LP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A): Standard European flangeless mounting base. B501BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm²). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224BI(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). ACCESSORIES F110: Retrofit flange to convert B210LP(A) to match the B350LP(A) profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B210LP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-200B: Black detector covers for use with SD355(A) only; box of 10. WCK-200B: White detector covers for use with SD355(A) only; box of 10. DF-52086 • 07/08/04 — Page 1 of 4 GENERAL System Sensor’s SpectrAlert® Ceiling Mount Series Strobes and Horn/Strobes offer a fresh approach to the unique needs of ceiling-mount applications. Technology — Like the original SpectrAlert® line, the SpectrAlert® Ceiling Mount Series offers significant current draw reductions over other ceiling-mount strobes and horn/ strobes. Flexibility — SpectrAlert® Ceiling Mount strobes and horn/ strobes are available in seven different candelas, including 177 candela for sleeping areas. The horn/strobe’s tones are field-selectable with a three-position switch on the back of the unit. Selections include: electromechanical and 3 KHz tones; Temporal 3 and Non-Temporal 3 patterns; and high and low volume. Aesthetics — SpectrAlert® Ceiling Mount strobes and horn/ strobes offer a design that is sensitive to the aesthetic de- mands of ceiling-mount applications. The round shape main- tains a low-profile appearance, similar to that of a smoke de- tector. Its stylish curves and design further refine the aes- thetics over other generic wall/ceiling-mount designs. Yet SpectrAlert®’s round shape provides clearly visible “FIRE” identification from all angles. Installation — SpectrAlert®’s compact design also offers installation savings. The strobe and horn/strobe models mount to a 4" x 4" x 1-1/2" (101.6 x 101.6 x 38.1 mm) backbox, and take up little room in the backbox, making connections easier. With SpectrAlert®’s round shape, aligning the backbox with the room’s walls is not necessary — SpectrAlert® always lines up. FEATURES • Lower current draw. • Available in 15, 15/75, 30, 75, 95, 115, and 177 candela strobes. • Horn/strobe models include a three-position switch for field- selecting horn tones: electromechanical/3KHz; temporal 3/non-temporal 3; high/low dBA output. • Synchronizable with MDL Sync•Circuit™ module. • Ceiling-specific shape, profile, and aesthetics. • Mounts to a 4" x 4" x 1-1/2" (101.6 x 101.6 x 38.1 mm) backbox. • Round shape offers greater placement flexibility. SPECIFICATIONS Dimensions: 6.8" (172.72 mm) diameter. Mounting: 4" x 4" x 1-1/2" (101.6 x 101.6 x 38.1 mm) backbox. Indoor operating temperature: 32°F to 120°F (0°C to 49°C). Maximum humidity: 95% as tested per UL 464. Weight: 5.3 oz. (150 grams). SpectrAlert® Ceiling Mount Series SC Strobes and PC Horn/Strobes July 8, 2004 Section: Audio/Visual Devices 6798pho1.jpgSC Strobe (top) and PC Horn/Strobe (bottom)6798pho2.jpgDF-52086 • G-450 Operating voltage: 24 VDC and FWR unfiltered. Input terminals: 12 to 18 AWG (3.25 to 0.75 mm²). Operating voltage range: 24 volts, 16 – 33 volts. NOTE: 177 cd models tested at 20 – 33 V FWR and 16 – 33 VDC. Operating voltage range with Sync•Circuit™ module: 24 volts, 17 – 33 volts. NOTE: 177 cd models tested at 21 – 33 V FWR and 17 – 33 VDC. U.S. Patent Numbers: 6,049,446. 6,057,778. D424,465. SpectrAlert® is a registered trademark and Sync•Circuit™ is a trademark of System Sensor. S4011 S5512 CS549 California State Fire Marshal 7135-1209:204 7125-1209:201 MEA 144-00-E 61-00-E www.firelite.com Fire•Lite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product informa- tion up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. Page 2 of 4 — DF-52086 • 07/08/04 SPECTRALERT CURRENT DRAW Low Volume Electromechnical 300 Hz Interrupted High Volume Electromechnical 300 Hz Interrupted Low Volume Electromechnical 300 Hz Interrupted High Volume Electromechnical 300 Hz Interrupted Non-Temporal Temporal Selectable Horn Tones Red White SC2415 SC2415W 15/75 15 68 64 SC241575 SC241575W 24 15/75 77 78 SC2430 SC2430W 24 30 107 113 SC2475 SC2475W 24 75 197 205 SC2495 SC2495W 24 95 239 274 SC24115 SC24115W 24 115 298 325 SC24177 SC24177W 24 177 399 489 PC2415 PC2415W 24 15 68 64 57.5 57 75 PC241575 PC241575W 24 15/75 77 78 57.5 57 75 PC2430 PC2430W 24 30 107 113 57.5 57 75 PC2475 PC2475W 24 75 197 205 57.5 57 75 PC2495 PC2495W 24 95 239 274 57.5 57 75 PC24115 PC24115W 24 115 298 325 57.5 57 75 PC24177 PC24177W 24 177 399 489 57.5 57 75 DC FWR DC FWR DC FWR 12 10 12 30 31 87 122 24 11 15 35 37 198 262 MDL MDLW Average Current (mA) FWR Max. Operating Current - Horn (mA RMS) FWR Max. Operating Current - Horn (mA RMS) Horn Audibility (dBA) Peak Current (mA) In-rush Current (mA) General Notes: 1. All SC and PC strobes were only tested at the 16-33 Volt-FWR/DC Limits. This does not include the 80% low end and the 110% high end voltage limits. 2. Horn/Strobe current draws assume horn is set at Temporal 3, electromechanical tone, and high audihbility. FWR Max. Operating Current - Strobe (mA RMS) Ceiling Mount Strobes Ceiling-mount Horn/Strobes* Sync-Circuit Model No. Voltage Candela DC Max. Operating Current - Strobe (mA RMS) DF-52086 • 07/08/04 — Page 3 of 4 Mounting Strobe or Horn/Strobe with accessory Backbox Skirt BBSCW Surface-Mount Backbox Skirt Strobe or Horn/Strobe with Mounting Plate Page 4 of 4 — DF-52086 • 07/08/04 Strobe shall be a System Sensor SpectrAlert® Model ______ Listed to UL 1971 and be approved for fire protec- tive service where ceiling-mount strobes are permitted. The strobe shall be wired as a primary signaling notification appliance and shall flash at 1 Hz over the strobe’s entire operating range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe shall be a System Sensor SpectrAlert® Model ______ Listed to UL 1971 and UL 464 and be approved for fire protective service where ceiling-mount horn/strobes are permitted. The horn/strobe shall be wired as a primary sig- naling notification appliance and shall flash at 1 Hz over its entire operating range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options, and the option to switch between a temporal 3 pattern and a non- temporal continuous pattern. These options shall be se- lected by a multi-position switch. Strobes shall be powered independently of the sounder with the removal of factory- installed jumper wires. The horn on horn/strobe models shall operate on a coded or non-coded power supply. NOTE: The strobes must be powered continuously for the horn to operate. Model Number SC2415 SC2415W SC241575 SC241575W Ceiling-mount strobe, 24 volt, 1575 candela, white SC2430 SC2430W SC2475 SC2475W SC2495 SC2495W SC24115 SC24115W SC24177 SC24177W PC2415 Ceiling-mount horn/strobe, 24 volt, 15 candela, red PC2415W Ceiling-mount horn/strobe, 24 volt, 15 candela, white PC241575 Ceiling-mount horn/strobe, 24 volt, 1575 candela, red PC241575W Ceiling-mount horn/strobe, 24 volt, 1575 candela, white PC2430 Ceiling-mount horn/strobe, 24 volt, 30 candela, red PC2430W Ceiling-mount horn/strobe, 24 volt, 30 candela, white PC2475 Ceiling-mount horn/strobe, 24 volt, 75 candela, red PC2475W Ceiling-mount horn/strobe, 24 volt, 75 candela, white PC2495 Ceiling-mount horn/strobe, 24 volt, 95 candela, red PC2495W Ceiling-mount horn/strobe, 24 volt, 95 candela, white PC24115 Ceiling-mount horn/strobe, 24 volt, 115 candela, red PC24115W Ceiling-mount horn/strobe, 24 volt, 115 candela, white PC24177 Ceiling-mount horn/strobe, 24 volt, 177 candela, red PC24177W Ceiling-mount horn/strobe, 24 volt, 177 candela, white Accessories MDL MDLW BBSC BBSCW Ceiling-mount strobe, 24 volt, 115 candela, red Sync•Circuit™ module, red Sync•Circuit™ module, white Ceiling-mount strobe, 24 volt, 75 candela, red Ceiling-mount strobe, 24 volt, 75 candela, white Ceiling-mount strobe, 24 volt, 95 candela, red Ceiling-mount strobe, 24 volt, 115 candela, white Ceiling-mount strobe, 24 volt, 177 candela, red Ceiling-mount strobe, 24 volt, 177 candela, white Ceiling-mount strobe, 24 volt, 95 candela, white Surface-mount back box skirt, red Description Ordering Information Surface-mount back box skirt, white Ceiling-mount strobe, 24 volt, 15 candela, red Ceiling-mount strobe, 24 volt, 15 candela, white Ceiling-mount strobe, 24 volt, 1575 candela, red Ceiling-mount strobe, 24 volt, 30 candela, red Ceiling-mount strobe, 24 volt, 30 candela, white ARCHITECTURAL/ENGINEERING SPECIFICATIONS