HomeMy WebLinkAboutAdemco VISTA.pdfThe VISTA-128BPE is a powerful member of the Honeywell family of commercial alarm panels, integrating burglary, CCTV and access control functions. Many features are available that extend the applications of the VISTA-128BP while simplifying end-user operation. The VISTA-128BP and VISTA-128BPE (VISTA-128BP Rev. 4) are Listed for residential burglary, residential fire and commercial burglary applications (see agency listings in this document for more details). They are compatible with a wide range of AlarmNet communications products for alarm reporting, uploading/downloading and remote services. Standard features (VISTA-128BP and VISTA-128BPE): • Provides nine style-B hardwired zones • Supports up to 119 additional zones using a built-in polling (V-Plex, multiplex) loop interface • Supports up to 127 wireless zones using up to two 5800 series wireless receivers (fewer if using hardwire and/or polling loop zones) • Provides one power-limited bell circuit delivering 1.7Amp (max) at 12Vdc • Provides the ability to control eight separate partitions independently, each functioning as if it had its own separate control • Accommodates 150 user codes with seven authority levels • Accommodates 32 keypad macro commands per system • Keeps a log of up to 512 events • VistaView-100 CCTV support • Supports up to 16 compatible two- wire smoke detectors on zone 1 • Supports up to 50 latching-type glassbreak detectors on zone 8 • Zone 7 may be used for keyswitch arming/disarming • Supports V-Plex®addressable VistaKey access control (up to eight doors and 250 cards) • Easily programmed and maintained by Compass Windows-based downloader • Supports up to 96 programmable outputs • Programmable to meet SIA false alarm prevention specifications. To meet UL approval for ANSI/SIA CP-01-2000 order part number VISTA-128SIA • Panel Linking up to eight panels • Supports eight numeric pager numbers • Supports touchscreen Advanced User Interface (AUI) • Smoke detector reset at keypad • Quick exit • Group bypass • Arm faulted • Event arming • Scheduled check-in • Arm stay by group Enhanced features (VISTA-128BPE only): • Carbon monoxide (CO) zone type support • Expanded RS-232 capability for third party interface and automation • Internet upload/download over AlarmNet GSM, iGSM and IP communicators over the panel's keypad (ECP) bus • Ringback support for AlarmNet communicators (confirmation of closing report) • 24-hour dialer test support for AlarmNet devices FEATURES VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS Basic Hardwired Zones Provides nine style-B hardwired zones with the following characteristics: • EOLR supervision (optional for zones 2-8) supporting N.O. or N.C. sensors (EOLR supervision required for fire and UL burglary installations) • Individually assignable to one of eight partitions Polling Loop Expansion Supports up to 119 additional zones using a built-in polling (V-Plex, multiplex) loop interface. Current draw can total up to 128mA. Polling loop zones have the following characteristics: • Must use V-Plex devices • Supervised by control panel • Individually assignable to one of eight partitions Wireless Expansion Supports up to 127 wireless zones using up to two 5800 series wireless receivers (fewer if using hardwire and/or polling loop zones). Wireless zones have the following characteristics: • Supervised by control panel for check-in signals (except certain non-supervised transmitters) • Tamper protection for supervised transmitters • Individually assignable to one of eight partitions Scheduling Provides the following scheduling capabilities: • Open/close schedules (for control of arming/disarming and reporting) • Holiday schedules (allows different time windows for open/close schedules) • Timed events (for activation of relays, auto-bypassing and unbypassing, auto-arming and disarming, etc.) • Access schedules (for limiting system access to users by time) • End user output programming mode (provides 20 timers for output control) Eight Partitions Provides the ability to control eight separate areas independently, each functioning as if it had its own separate control. Partitioning features include: • A Common Lobby partition (1-8), which can be programmed to arm automatically when the last partition that shares the common lobby is armed, and to disarm when the first partition that shares the common lobby is disarmed • A Master partition (9), used strictly to assign keypads for the purpose of viewing the status of all eight partitions at the same time (master keypads) • All zones assignable to one of eight partitions • Keypads assignable to one of eight partitions or to Master partition 9 to view system status • Ability to assign relays to one or all eight partitions • Ability to display fire and/or burglary and panic and/or trouble conditions at all other partitions’ keypads (selectable option) • Individually programmable account number, entry delay and exit delay by partition ADDITIONAL FEATURES 4293SN Adapters VISTA-128BP 4101SN Relay Module FG1625SN Glassbreak 4208U Eight-zone Expansion Module and 4208EX Eight-zone V-Plex Expander 710Light 748Horn 5881 Wireless Receiver 6160 Console 4204RelayModule Phone Line to Central Station GSM iGSM or Notification Appliances Keyswitch Option 4146 5193 Series Smoke Detectors V-Plex Loop Alpha PagingModule Parallel Printer Serial Printer RS-232 DT7500SN V-Plex DUAL TEC Motion Sensor NOTE: Please refer to the website (www.honeywell.com/security/hsc) for the latest product information. 7847i ECP Bus or VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS 6160 Console Glassbreak Detectors 4944SN Contact 5881ENHC Commercial Wireless Receiver (Max Two) 4204RelayModule 4204CF Supervised NAC Module Supports Up To 16 Conventional Two-WireSmoke Detectors 4209U Group Zoning Module 4190SN Remote Point Module4193SN Serial Interface Module 4959SN Overhead Door ContactIS2500SN V-Plex PIR Motion Sensor 4208U Eight-zone Expansion Module Panel Linking Module Panel Linking Module VISTA-128BP ECP Bus 5808W3WirelessSmokeDetector 5890Wireless PIR5816 Door/Window Transmitter VISTA-128BP 5800 Series Wireless Devices VISTAKey V-Plex Access Control Module 5817CB Universal Contact Monitoring Transmitter 5869 Commercial UL Wireless Hold-up Button Auxiliary Devices • 4204 - Relay Module, four form C contacts • 5881 Series - RF Receiver supporting 5800 wireless detectors • 6160 - Alpha Keypad/Annunciator • 6220S - System Printer used with 4100SM serial module • VA8200 - (PLM) Panel Linking Module • VA8201 - (APM) Alpha Paging Module Manual Pull Stations • 5140MPS-1 • 5140MPS-2 V-Plex (addressable) Devices • 4101SN Single Relay/zone Module • 4190SN Remote Point Module - two zones • 4193SN Two zone Serial Interface Module • 4208EX - Eight zone expander for ULC commercial installations • 4208U Loop Expansion Module - eight zones • 4209U Group zoning Module - two/four zones • 4293SN One zone Serial Interface Module • 4297 Isolation/Extender Module V-Plex (addressable) smoke detectors • VSI Short/Overload Isolation Module • 5193SD • 5193SDT Passive Infrared Detectors • 998MX • IS2500SN • DT7500SN • QUEST2260SN V-Plex (Addressable) Contacts • 4939SN-WH • 4944SN-WH • 4959SN, 9500SN V-Plex Glassbreak Detectors • FG1625SN VISTA Interactive Phone Module • 4286 VIP Module Optional Communicators • AlarmNet Internet/Intranet communicators and digital cellular communicators Access Control • VISTAKey V-Plex (addressable) Access Control • VISTAKey-SK Starter Kit • VISTAKey-EX Expansion Kit CCTV • Optiflex CCTV module Wireless Devices • 5804 - Wireless Key • 5804BD - Bidirectional Key • 5804BDV - Bidirectional with voice • 5816 - Door/Window Transmitter • 5819 - Shock Sensor • 5827BD - Bidirectional Keypad • 5853 - Glassbreak Detector • 5894 - Wireless PIR Motion Sensor • 5890 - Passive Infrared Detection • 5800PIR-OD - Outdoor Motion Sensor • 5870API - Asset Protection Device • 5800PIR/5800PIR-RES/5800PIR- COM—Wireless Motion Detectors • 5800CO/A - Wireless Carbon Monoxide Detector • 5800RP - Wireless Repeater • 5808W3 - Wireless Smoke Detector • 5809 - Wireless Heat Detector Commercial Listed Wireless Devices • 5817CB - Commercial UL Burglary, Universal Contact Monitoring Transmitter* • 5869 - Commercial UL Wireless Hold-up Button* • 5881ENHC and 5883H Receivers *When used with 5881ENHC and/or 5883H receiver. ACCESSORIES ORDERING VISTA-128BP Commercial Burglary Alarm Control Panel (UL Listed) VISTA-128BPE Enhanced Commercial Burglary Alarm Control Panel (ETL Listed as VISTA-128BP Rev. 4, UL Pending) VISTA-128SIAE SIA Approved Enhanced Commercial Burglary Alarm Control Panel L/VSTA128BPD/D April 2010 © 2010 Honeywell International Inc. For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 1.800.467.5875 www.honeywell.com VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS Agency Listed to the Following Standards: • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault • UL611/UL1610 Grades A, AA Central Station • UL365 Grades A, AA Police Connect • UL985 Household Fire • UL1023 Household Burglar Alarm California State Fire Marshall (CSFM) • UL1635 - Digital Alarm Communicator System Units • CAN/ULC - S303 • CAN/ULC - S304 • CAN/ULC - S545 • CAN/ULC - S1023 • For commercial burglary attack proof requirements, use VISTA-ULKT attack proof enclosure Electrical • Voltage Input: From Honeywell No. 1361 Plug-In Transformer or 1361X10 transformer (for X-10 installations) rated 16.5VAC, 40 VA • Use 1361CN plug-in transformer for Canada • Alarm Sounder Output: 10VDC- 13.8VDC, 1.7 amps max., (UL1023, UL609 installations); 750mA less aux. current draw (UL985 installations) • Auxiliary Power Output: 9.6VDC- 13.8VDC, 750mA max. For UL installations, the accessories connected to the output must be UL Listed, and rated to operate in the above voltage range • Backup Battery: 12VDC, 4AH or 7AH sealed-lead acid. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH) recommended • Standby Time: Four hours min. with 750mA aux. load using 7AH battery • Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts). A solid state circuit breaker is used on auxiliary power output to protect against wiring faults (shorts). Main Dialer • Formats Supported: ADEMCO Contact ID, ADEMCO High Speed, ADEMCO 4 + 2 Express, ADEMCO Low Speed, Sescoa and Radionics Low Speed • Line Seize: Double Pole • Ringer Equivalence: 0.7B Cabinet Dimensions 12-1/2" W X 14 1/2" H X 3" D SPECIFICATIONS