HomeMy WebLinkAbout5123 BLACK BEAR DATA SHEETS.pdfNetworX Control Panels Models NX-4, NX-6, NX-8 and NX-8E interlogix.com Intrusion The NetworX line of control panels represent a full-featured security system that uses advanced technology for burglary, fire and environmental detection. A highly flexible security option that is both easy to install and simple to use, NetworX control panels can accommodate smaller residential applications up to the most demanding commercial security needs. The series includes the NX-4, NX-6, NX-8 and NX-8E control panels. Outstanding features Offering up to eight standard hardwire zone inputs, the control panels also provide four programmable outputs that can be set up to activate external devices during an alarm or other system event. The modular design allows for complete integration of multiple systems within one enclosure, and adding more zones or expanding capability is fast and easy. With the addition of a Z-Wave® enabled Cellular Module, with service from Alarm.com, control of automated lights, door locks, thermostats and more is available using almost any Web enabled device. Convenient and flexible Users can conduct quick and easy on-site programming with alphanumeric keypads and a menu-driven text interface. Off-site programming is also available with DL-900 software for Windows. NX-4 Four hardwire zone inputs, expandable to 8 fully programmable hardwire and/or wireless zones NX-6 Six hardwire zone inputs, expandable to 12 fully programmable hardwire or 16 wireless zones NX-8 Eight hardwire zone inputs, expandable to 48 fully programmable hardwire and/or wireless zones NX-8E Eight hardwire zone inputs and two relays, expandable to 192 fully programmable hardwire and/or wireless zones Overview • Flash memory microprocessor • Expanded event log • Early open/late close reporting • Programmable loop response • Accommodates multiple user codes from 8 up to 240 • Up to 8 true partitions with separate account codes, entry/exit delays and feature selections for each partition • Up to 512-event history log that provides date, time, event and user number • Supports SIA and contact ID communication formats • 2-wire or 4-wire smoke detector compatibility • CP-01 2000 compliant In addition, NX-8E control panel also offers • Fire alarm verification for greater false alarm immunity • Dynamic battery test • Standard RS-232 on-board interface Standard FeatureS Description NX-4 NX-6 NX-8 NX-8E Standard hardwire zones 4 6 8 8 Maximum hardwire zones 8 12 48 192 Maximum wireless zones 8 16 48 192 Partitions 1 2 8 8 Event log 185 512 User codes 8 40 99 240 Smoke loop 4-wire only 2-wire/4-wire Built-in siren driver 2 Tone (Steady & Yelp) Operating power 16.5VAC, 40VA Auxiliary power 1 Amp 2 Amp Operating temperature 0ºC to 49ºC (32ºF to 120ºF) Dimensions (H x W x D)8.3 x 9.3 x 3.5 in.11.3 x 11.3 x 3.5 in. Regulatory UL365, 609, 985, 1023, 1610, 1635, 1637 CAN/ULC-S303-M91; S545-M89; ORD-C1023-1974 Specifications NetworX Control Panels Models NX-4, NX-6, NX-8 and NX-8E North America T 855-286-8889 Asia T 852-2907-8108 Australia T 61-3-9239-1200 Europe T 32-2-725-11-20 Latin America T 561-998-6114 interlogix.com Z-Wave® is a registered US trademark of Zensys A/S. Complies with FCC and Industry Canada regulations. Specifications subject to change without notice. © 2013 Interlogix. All rights reserved. Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. 302-3631 2013/06 (73841) Ordering Information NX-4 Four Hardwire Zone Inputs, Expandable to 8 Fully Programmable Hardwire and/or Wireless Zones NX-6 Six Hardwire Zone Inputs, Expandable to 12 Fully Programmable Hardwire or 16 Wireless Zones NX-8 Eight Hardwire Zone Inputs, Expandable to 48 Fully Programmable Hardwire and/or Wireless Zones NX-8E Eight Hardwire Zone Inputs and Two Relays, Expandable to 192 Fully Programmable Hardwire and/or Wireless Zones Accessories 600-1023 Transformer, 16.5VAC, 40VA NX-320E Smart Power Supply and Bus Extender NX-148E LCD Keypad NX-148E-RF LCD Keypad w/Integrated 48-Zone Wireless Receiver NX-548E 48-Zone Wireless Receiver NX-582E AES Long-Range Radio Interface Module NX-584 Home Automation Interface Module with RS-232 NX-590NE TCP/IP Module NX-591NE-GSM 3G/4G GSM Module (Multi-Carrier) NX-592E-GSM-ZX-AT Alarm.com 3G/4G GSM Module w/Z-Wave,® AT&T™ NX-592E-GSM-ZX-TM Alarm.com 3G/4G GSM Module w/Z-Wave, T-Mobile® NX-592E-CDMA-ZX-VZ Alarm.com CDMA Module w/Z-Wave, Verizon® Wireless Intrusion The NetworX wireless LCD display keypad is an integrated 48-zone wireless receiver LCD keypad with traditional design and an easy-to- read, customizable display. It is compatible with all NetworX control panels. The NetworX wireless LCD display keypad offers the convenience of having an integrated wireless receiver built into the keypad along with standard hardwire features. A removable door allows the user to swing the door down or simply take it off for use. The emergency keys are highlighted on the keypad and can be programmed to contact and send complete information to a responding police, fi re or EMS unit with just one touch. There are also fi ve pre-programmed touch keys that allow the most common functions to be performed with ease. All keys are backlit to ensure error-free operation — even in a dark room. The NetworX wireless LCD display keypad is cost-effective and easy to install. Designed for functionality and compatibility, it's the right keypad to fi t any application. OVERVIEW • Integrated 48-zone wireless receiver • Optimize wireless reception by having the keypad/receiver in the best location • LCD, easy-to-read programmable display • Traditional design to go with any decor • Compatible with all NetworX series control panels • Easy to install, program and maintain STANDARD FEATURES NetworX Wireless LCD Display Keypad interlogix.com North America T 855-286-8889 Latin America T 561-998-6114 Ordering Information NX-148E-RF NetworX 48-Zone LCD Display Keypad w/Door and Integrated Wireless Receiver Specifi cations Electrical Current 75mA maximum Wireless Frequency 319.5MHz Range 600ft. (183m) open air Environmental Operating temperature 32°F~120°F (0°C~49°C) Physical Dimensions (HxWxD) 5.3 x 6.2 x 1.1 in. (135 x 157 x 27 mm) Construction ABS plastic Color White Specifi cations subject to change without notice. © 2014 United Technologies Corporation. All rights reserved. Interlogix is part of UTC Building & Industrial Systems, a unit of United Technologies Corporation. 305-3662 2014/03 (74998) i4 Series Combination CO/Photoelectric Smoke Detector Best-in-class carbon monoxide (CO) and smoke detection technology in a single, system-connected device. Features • Single device for CO and smoke detection that uses less wiring and fewer junction boxes • Compatible with a wide range of control panels with the use of the required i4 Interface Module. • Sends distinct smoke and CO signals to the panel • Sounds Temporal 3 for smoke and Temporal 4 for CO • Built-in 85dB sounder • LEDs display both CO and smoke status • External IR LED provides extended range sensitivity testing • Versatile mounting allows for wall or ceiling placement • Easily replaceable electrochemical CO cell with 6-year end-of-life timer that signals the panel and chirps to alert the homeowner • RealTest® enables functional test using canned CO • Drift compensation and smoothing algorithms provide false alarm immunity • Compatible with SENS-RDR sensitivity tester • Full agency compliance with UL 268 and UL 2075 Integration: The i4 Series combines CO and smoke detection into one device, requiring less wiring and fewer back boxes than two separate devices. The i4 Series is compatible with i3 (2WTA-B or 4WTA-B), so an attractive CO monitoring solution can easily be retrofitted into existing i3 installations. The i4 Series CO cell can be easily replaced at end-of-life, resulting in a much lower life cost than having to replace the entire detector. Installation ease: The i4 Series Combination CO/Smoke detector requires less wiring than two separate CO and smoke devices. Installers can pre-wire its plug-in base, while its large wire-entry port and in-line terminals provide ample room for neatly routing wiring. The base accommodates several back box options and also direct mounts using drywall anchors. The i4 head plugs into the base with a simple Stop-Drop `N Lock™ action. When the detector’s CO cell reaches end- of-life, it can be easily replaced in the field without a tool. Intelligence: With the help of the module, the i4 Series transmits distinct CO and smoke signals, allowing appropriate response from the central monitoring station. Intelligent features, such as drift compensation and smoothing algorithms, reduce nuisance alarms. Instant inspection: The i4 Series LEDs enable instant inspection of detector status signaling normal/standby condition, alarm condition, maintenance/trouble condition or functional test mode. 2-wire devices allow loop testing via the EZ Walk feature where wiring can easily be verified by checking the LED status at each detector. Smoke sensitivity can be easily measured using the wireless SENS- RDR device. CO cell functionality can also be quickly validated in the field with canned CO per NFPA 720: 2009 requirements using the detector’s RealTest functionality. 4 Agency Listings S268 1653:0227 Physical Specifications Dimension:Diameter: 5.5˝; Depth: 2.5˝ (includes base) Weight:9.2 oz. (261 g) Operating Temperature Range:0 – 50° C (32 – 122° F) Operating Humidity Range:20-95% RH Storage Temperature Range:-10 – 70° C (14 – 158° F) Sensitivity:2.5%/ft nominal Input Terminals:14 to 22 AWG Mounting:Back boxes: 3.5˝ and 4˝ Octagonal; Single-gang; 4˝ Square; 2 x 4˝, 3.5˝ and 4˝ round ceiling. Direct mount to wall or ceiling. Electrical Specifications Operating Voltage (VDC):Nominal: 12/24; Minimum: 8.5; Maximum: 35 Maximum Standby Current:50 µA Maximum Alarm Current:2-Wire 50mA; 4-Wire 40mA Audible Signal:85 dBA Maximum Reverse Polarity Current:20 mA Maximum Start-up Current:200uA Maximum Start-up Capacitance:.10 µF Operation Modes / LED Status Green Red Blue Sounder Alarm Smoke:Off On Off Temp 3 Alarm CO:Off Off On Temp 4 Alarm Smoke & CO:Off On On Temp 3 Power Up:Blink 5 sec.Blink 5 sec Blink 5 sec.Off Standby:Blink 5 sec.Off Off Off RealTest® Mode (CO):Off Off Blink 1 sec.Off After CO is Sprayed:Off Off On Temp 4 Smoke Maintenance:Off Blink 5 sec.Off Off CO Trouble:Off Off Blink 5 sec.Off End-of-Life:Off Off Blink 5 sec.Intermittent i4 Series Combination CO/Smoke Detector Specifications Carbon monoxide (CO)/Smoke detector shall be a System Sensor model number COSMO-2W (2-Wire) / COSMO-4W (4-Wire) listed to UL 268 for Fire Protection Signaling Systems and to UL 2075 for Carbon Monoxide Gas Detection. The detector shall be photoelectric smoke sensing and electrochemical CO sensing and equipped with a sounder capable of Temp 3 and Temp 4 audible signals. The detector shall have nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface mount) to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide LED indication that blinks to indicate normal standby, smoke alarm, smoke maintenance, CO alarm, CO trouble/end-of-life. When the detector is in CO trouble condition, it shall send a trouble signal to the panel. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. The 2-wire model shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. The detector shall have a replaceable CO cell that can be replaced at end of cell life. Features • Easily integrates up to 12 compatible detectors to a wide range of control panels • 2-wire module is compatible with COSMO-2W combination detectors and 2WTA-B smoke detectors. • 4-wire module is compatible with COSMO-4W combination detectors and 4WTA-B smoke detectors. • Sends distinct smoke and CO signals from i4 detectors to the panel • LED indication shows when a detector on the loop requires cleaning or maintenance (2-wire detectors only) • Initiates the EZ Walk loop test (2-wire detectors only) • Module interconnects the sounders of all devices connected to it. No RSS-MOD is required. Optional trigger inputs are provided to sound multiple modules. i4 Series Interface and Reversing Relay Module The i4 Interface Module connects up to 12 detectors to a wide range of control panels using only 2 to 3 zones. It also interconnects the devices, so when one device alarms, they all sound. Integration: The i4 module allows up to 12 i4 Series or compatible i3 Series smoke detector models to be integrated into a fire alarm panel using only 2 to 3 zones: a smoke zone, a CO zone and an optional trouble zone. Detectors sound Temp 3 for smoke and Temp 4 for CO events. The i4 module can be used to alarm all sounders in compatible detectors for smoke and CO events. When one detector detects smoke or CO and goes into alarm, all connected detectors alarm, offering the highest level of warning to the homeowner. Installation ease: The i4 Series Interface Module mounts to a 411/16-inch square back box for quick and easy installation. Terminal blocks with durable SEMS screws ensure a reliable connection. It also has pre-drilled holes for easy mounting inside a metal enclosure Intelligence: The i4 Interface Module allows i4 and compatible i3 smoke detector models (2WTA-B and 4WTA-B) to communicate with any listed fire alarm control panel capable of utilizing this module. Instant inspection: The i4 Interface Module provides LED status indication for the loop, displaying normal operation, loop wiring fault, smoke events, smoke maintenance (2-wire only), CO events, and CO maintenance/end-of-life. Agency Listings S911 1653:0228 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2013 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. CODS30302 • 11/13 Ordering Information Part No.Description COSMO-2W 12/24 volt, 2-wire, system-connected, combination carbon monoxide/smoke detector with RealTest technology COSMO-4W 12/24 volt, 4-wire, system-connected, combination carbon monoxide/smoke detector with RealTest technology COSMOD2W 2-wire interface module (required to use with COSMO-2W models) COSMOD4W 4-wire interface module (required to use with COSMO-4W models) CO-REPL Replacement CO cell for COSMO-2W and COSMO-4W models SENS-RDR Sensitivity reader EOLR-1 End-of-line relay (required with 4-wire systems) Module Power-Up Sequence / LED Status Condition Duration Maintenance/Freeze trouble LED indication 6 minutes EZ Walk test available 6 minutes after power up or panel reset Operation Modes / LED Status Green Yellow Red Blue Alarm Smoke:Blink 1 sec.Off On Off Alarm CO:Blink 1 sec.Off Off On Alarm Smoke & CO:Blink 1 sec.Off On On No power / No communication:Off Off Off Off Loop wiring fault:Blink 1 sec.On Off Off EZ Walk Test Mode (2-wire only):Blink 1 sec.Blink 5 sec.Off Off Smoke Maintenance (2-wire only):Blink 1 sec.Off Blink 5 sec.Off Smoke Freeze Trouble (i3 2WTA-B only):Blink 1 sec.Off Blink 10 sec.Off CO Trouble:Blink 1 sec.Off Off Blink 5 sec. Electrical Specifications Module Operating Voltage (VDC):Nom.: 12/24; Min.: 8.5 (2-wire), 10 (4-wire, power limited); Max.: 35 VDC (power limited) Standby Current:2-Wire: 61mA (max.), 45mA (12V In), 26mA (24V In); 4-Wire: 52mA1 (max.), 37mA1 (12V In), 22mA1 (24V In) Alarm Current2:2-Wire: 181mA (max.), 121mA (12V In), 64mA (24V In); 4-Wire: 78mA1 (max.), 57mA1 (12V In), 34mA1 (24V In) Maximum Ripple Voltage:30% of applied power Maximum Alarm Threshold:9.2 Volts DC Alarm and Maintenance Contact Rating:100 mA @ 36 Volts DC, resistive, 25 ohms Maximum Loop Wiring Resistance: 2-Wire 50 Ohms; 4-Wire 300 Ohms Trigger inputs:Min On Voltage: 1.5V; Max.: Vin 1 Does not include current draw from attached detectors or EOL relay. 2 Does not include reverse polarity current draw from attached detectors. i4 Series Interface Module Specifications The i4 module shall be a System Sensor i4 Series model number COSMOD2W (2-wire) or COSMOD4W (4-wire) listed to UL 864 and UL 985 for Control Units for Fire Protection Signaling Systems. The module shall include provisions for mounting to 4-inch square back box. Wiring connections shall be made by means of SEMS screws. The module shall provide 4 LED indicators that blink or illuminate to indicate communication status, maintenance alert, alarm or freeze trouble conditions, and EZ Walk loop test mode (2-wire module only). The module shall allow communication to i4 Series and i3 Series detectors with sounders with any UL 864- and UL 985-listed fire alarm control panel capable of utilizing this module. The 2-wire module shall offer provisions for Style D / Class A wiring on IDC loops and shall provide a loop testing capability (EZ Walk) to verify the initiating loop wiring. Physical Specifications Module Dimension:Height: 6.04˝; Width: 6.04˝; Depth: 1.00˝ Weight:9.6 oz. 272 (g) Operating Temperature Range:0 – 50° C (32 – 122° F) Operating Humidity Range:5 - 95% RH Storage Temperature Range:-20 – 70° C (-4 – 158° F) Input Terminals:14 to 22 AWG Mounting:411/16˝ square back box or inside a metal enclosure SS-500-004 1 I56-3871-001 i4 Series Interface Module COSMOD2W and COSMOD4W *For use with COSMO-2W and COSMO-4W detectors INSTALLATION AND MAINTENANCE INSTRUCTIONS 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6583 www.systemsensor.com SPECIfICATIONS Electrical Specifications Power Supply Voltage: Resettable power; 2-Wire: Min. 8.5 Volts DC (Power limited); Max. 35 Volts DC (Power limited); 4-Wire: Min. 10 Volts DC (Power limited); Max. 35Volts DC (Power limited) Device Power-up Time: 200 milliseconds Max. Standby Current: 2-Wire: 62mA; 4-Wire: 52mA (Does not include current draw from attached detectors or EOL relay) Max. Alarm Current: 2-Wire: 174mA; 4-Wire: 75mA (Does not include reverse polarity current draw from attached detectors) Nom. Standby Current: 2-Wire: 45mA@12V, 27mA@24V; 4-Wire: 36mA@12V, 21mA@24V (Does not include current draw from attached detectors or EOL relay) Alarm Contact Rating: 100 mA @ 36 Volts DC, resistive, 25 ohms Maintenance Contact Rating: 100 mA @ 36 Volts DC, resistive, 25 ohms Max. IDC Loop Wiring Resistance: 2-Wire: 50 Ohms; 4-Wire: 300 Ohms Trigger Inputs: Min. On Voltage: 1.5V; Max. On Voltage=Vin Aux Power Out: Same Voltage as Input Power (Unregulated, limited to 250mA) Min. Reset Time: 300 milliseconds Initial Communication Cycle: 6 minutes EZ Walk Test Availability: 6 minutes after power up or panel reset Physical Specifications Operating Temperature Range: 0 - 50° C (32 - 122° F) Operating Humidity Range: 5 - 95% RH Storage Temperature Range: -20 - 70° C (-4 - 158° F) Height: 6.04 inches Width: 6.04 inches Depth: 1.16 inches Shipping Weight: 0.6 lbs Wire Gauge Acceptance: Min: 22 AWG; Max: 14 AWG 2-wire Compatibility Requirements Min. Loop Voltage: 12.9 Volts DC Max. Loop Voltage: 14.5 Volts DC Max. Loop Resistance: 50 Ohms Max. Loop Ripple: 240 mVpp Max. Loading Capacitance: 0.01 mF Max. Alarm Current: 46 mA Max. Reset Voltage: 0.30 Volts DC Alarm Delay: n/a Min. Alarm Reset Time: 0.3 seconds Max. Normal Load Current: 2.4 mA Zone Type: Standard EOL Device: 3.9k Ohms (+-5%) Loop Style: B and D Compatibility Zone Identifier: A Detector Zone Identifier: A Max. Detectors Per Zone: (12) 2-wire i4 series model #COSMO-2W and/or i3 series model #2WTA-B detectors I56-3871-001BEfORE INSTALLATION This information is included as a quick reference installation guide. Refer to the control panel installation manual for detailed system information. If the module will be installed in an existing operational system, inform the operator and local authority that the system will be temporarily out of service. Discon- nect power to the control panel before installing the module. Notice: This manual should be left with the owner/user of this equipment. This product is intended for use in ordinary indoor locations. GENERAL DESCRIPTION The i4 series module is designed to interface between compatible i4 series combination CO/smoke detectors (Model COSMO-2W and COSMO-4W) and compatible security/fire panels. It can also be used to retrofit compatible i4 series detectors into an existing loop of i3 smoke detector models 2WTA-B or 4WTA-B, without adding wires. The module interprets signals and translates them into a separate smoke zone and a separate CO zone, each with alarm and trouble signals. When signaled by the panel, a module will synchronize connected detector sounders in either Temporal 3 or Temporal 4 pattern. Local status indication is provided by 4 LED’s and a 3 position DIP switch enables user configuration. The i4 COSMOD2W, 2-wire interface module, offers additional functionality including: • Ability to query for a “need for maintenance” condition from 2-wire i4 series model COSMO-2W and i3 series model 2WTA-B smoke detectors • One relay is available to indicate a multitude of maintenance conditions at the control panel • All conditions are displayed at the module and at the detector • EZ Walk test mode allows the installer to easily verify that all detectors on a loop are operational • Allows 2-wire smoke detectors to be used on any compatible 4-wire control panel and provides Style D wiring on the detector loop fEATURES • Compatible with System Sensor i4 series combination CO/smoke detectors and System Sensor i3 Series smoke detectors models 2WTA-B or 4WTA-B. • Allows up to 12 compatible devices including the i4 series combination CO/smoke detector to be integrated with a panel SS-500-004 2 I56-3871-001 • Allows sounder activation of all detectors on loop in either Temporal 3 or Temporal 4 pattern VISIBLE ANNUNCIATON The i4 series interface module has four visible LED’s: The green LED is a su- pervisory LED; it blinks during power on, reset, and during normal operation. The yellow LED is used to indicate a loop wiring fault and will blink when it is in EZ Walk test mode. The red LED signals smoke events; it blinks during smoke maintenance events and lights constantly during smoke alarm events. The blue LED signals CO events; it blinks during CO trouble or CO end-of-life, and lights constantly during CO alarm. fIGURE 1: MODULE fRONT VIEW Green LED Yellow LED Red LED Blue LED EZ Walk Test Switch(2-wire only) S0331-00 TABLE 1: OPERATION MODES OPERATION MODE GREEN LED yELLOW LED RED LED BLUE LED Normal (standby)Blink 5 Sec.OFF OFF OFF No power/ Non-operational OFF OFF OFF OFF Loop wiring fault Blink 5 Sec.ON OFF OFF EZ Walk Test Mode (2-wire only)Blink 5 Sec.Blink 5 Sec.OFF OFF Alarm Smoke Blink 5 Sec.OFF ON OFF Alarm CO Blink 5 Sec.OFF OFF ON Alarm Smoke & CO Blink 5 Sec.OFF ON ON Maintenance (2-wire only)Blink 5 Sec.OFF Blink 5 Sec.OFF Freeze Trouble (2- wire only)Blink 5 Sec.OFF Blink 10 Sec.OFF CO Trouble Blink 5 Sec.OFF OFF Blink 5 Sec. NORMAL (STANDBy) The module is powered and detectors on the loop are operating normally. NO POWER/NON-OPERATIONAL Power is not applied to the module or communication between the module and the detectors on the loop is unsuccessful. LOOP WIRING fAULT If an open circuit occurs on the loop, the module will indicate the condition by illuminating the yellow LED. 2-wire units will then power the style-D ter- minals. When the wiring issue on the loop has been resolved, the module will turn the yellow LED off. Ez WALk TEST MODE This indicates the module and detectors are in EZ Walk Test Mode. See “EZ Walk Test” section for instructions on how to initiate and perform the EZ Walk test. ALARM SMOkE/ALARM CO/ALARM SMOkE & CO A smoke alarm will be indicated by the red LED. A CO alarm will be indicated by the blue LED. A smoke alarm is not self-restoring. Once a smoke alarm has been signaled, the red LED will illuminate until the module is reset by removal of power. Note: On some panels, resetting a smoke alarm may require additional steps at the keypad to clear the trouble conditions on CO and smoke mainte- nance zones due to power loss to the module. A CO alarm is self-clearing. Once a CO alarm has been signaled, the blue LED will illuminate. Once the initiating device ceases to signal the CO event, the blue LED will turn off. If a CO alarm is signaled, and not cleared, prior to a smoke alarm condition, the module will keep both the blue and red LED’s illuminated. If a smoke alarm is signaled first, the module will not be able to receive notification of a CO alarm condition and will not be able to report it to the panel. MAINTENANCE This condition means one or more detectors on the loop have a smoke main- tenance issue. See “Smoke Maintenance Inquiry” section for further details. fREEzE TROUBLE This condition means one or more detectors on the loop are measuring the ambient temperature is near the freezing point. See “Freeze Trouble Inquiry” section for further details. CO TROUBLE The module can be notified of a detector with a CO trouble condition. All CO trouble conditions will be reported on the CO zone and displayed with a blink- ing blue LED. The module is not able to determine the number of detectors that have a CO trouble condition or which trouble condition exists. INSTALLATION MOUNTING The module can be mounted to a 4-11/16 inch back box or inside a listed, dedi- cated enclosure. When mounting inside an enclosure with pre-stamped holes, it may be easier to align the bottom screw hole first. It is not necessary to use the module cover when mounting inside an enclosure. fIGURE 2: MOUNTING HOLE FOR MOUNTINGTO VISTA ENCLOSURE (No. 6x3/4 Type AB) SLOTS FOR MOUNTINGTO 4-11/16 JUNCTION BOXSLOT FOR MOUNTINGTO VISTA ENCLOSURE(No. 6x5/16Type AB or Type F)0331-00 WIRING GUIDELINES All wiring must be installed in compliance with the NFPA 70 standards, Na- tional Electrical Code, applicable state and local codes, and any special re- quirements at the local Authority Having Jurisdiction (AHJ). The screw terminals in the mounting base will accept 14-22 gauge wire. Wire connections are made by stripping approximately ¼” of insulation from the end of the feed wire, inserting it into the proper base terminal, and tightening the screw to secure the wire in place. Do not put wires more than 2 gauge apart under the same clamping plate. Note: The module must be installed in the same room and within 20 feet of the panel and enclosed within conduit or equivalently protected against me- chanical injury. WARNING Remove power from alarm control unit or initiating device circuits before in- stalling detectors. POWER IN + IDC + IDC – POWER IN – CO ALARM CONTACT CO TRIGGER SMOKE ALARM CONTACT MAINTENANCE TROUBLE RELAY CONTACT (COSMOD2W ONLY) SMOKE ZONE EOL RESISTOR (VALUE DEFINED BY PANEL) CO ZONE EOL RESISTOR (VALUE DEFINED BY PANEL) STYLE D + (4-WIRE DETECTOR POWER +) STYLE D – (4-WIRE DETECTOR POWER –) SMOKE TRIGGER / BELL IN SS-500-004 3 I56-3871-001 COSMO-2W 3.9kRESISTOR(suppliedwith module) LOOP STYLE D WIRING SMOKE AUXPOWER (resettable) SMOKE ZONE CO ZONE MAINT. ZONE SMOKETRIGGER OUT PanelEOLResistors COSMOD2W ALL CIRCUITS ARE SUPERVISED (EXCEPT TRIGGERS) AND MUST BE POWER LIMITED PanelEOLResistor CO TRIGGER OUT BELL OR COSMO-4W 3.9kRESISTOR (suppliedwith module) SMOKE POWER (resettable) SMOKE ZONE CO ZONE PanelEOLResistors COSMOD4W EOLRELAY#EOLR-1 ALL CIRCUITS ARE SUPERVISED (EXCEPT TRIGGERS) AND MUST BE POWER LIMITED CO TRIGGEROUT SMOKETRIGGER OUT BELL OR S0329-00 S0330-00 S0334-00 fIGURE 3: COSMOD2W WIRING DIAGRAM fIGURE 4: COSMOD4W WIRING DIAGRAM fIGURE 5: MODULE TERMINALS Note: See Table 3 for dip switch configurations WIRING DIAGRAMS Install module wiring in accordance with appropriate wiring diagrams. (Figure 3 and Figure 4) The module relays have a maximum ON resistance of 25 ohms. This resis- tance plus the wiring resistance to the panel must be less than the maximum zone wiring resistance stated in the panel manual. INPUT TRIGGERS/SOUNDER ACTIVATION Many panels can be programmed with triggers which are auxiliary relays that activate upon an alarm condition. Two inputs are used to signal the module to activate device sounders. The first is configurable by DIP switch to one of two modes; bell in or smoke trigger. When in the bell mode, the module will follow a valid coded signal from a Bell Out/NAC circuit consisting of high to low, then low to high for less than 1.9 seconds each. In smoke trigger mode, while the input is held high, the module will synchronize the detectors in a Temporal 3 pattern. The second input is for a CO trigger ; the CO trigger input allows a single mod- ule to have CO silence/hush capability and allows multiple module installa- tions to have all sounders activated in Temporal 4 in the event of a CO alarm. While the CO trigger is held high, the module will synchronize the detectors in a Temporal 4 pattern. After 30 minutes in Temporal 4 alarm, the time period between the Temporal 4 pulse will change from 5 seconds to 60 seconds. Note: CO trigger may not be used with UL 864 panels. All detectors will sound with no triggers connected, however, hush capability is not enabled. TABLE 2: DIP SWITCh CONfIGURATIONS DIP SWITCh # 1 DIP SWITCh # 2 DIP SWITCh # 3 ON (DEfAULT)Bell In Smoke Maint on Smoke Trouble and Form-B Maint Relay (COSMOD2W only) Unused Off Smoke Trigger Smoke Maint on Form-B Smoke main- tenance Relay only (COSMOD2W only) Unused POWER UP AND COMMUNICATIONS COMMUNICATIONS ChECk (2-WIRE ONLy) Upon power up, the module will send a request for communication check. All compatible detectors on the loop that understand the communication protocol will respond. If all detectors respond correctly, the green LED will blink once every 5 seconds. If the module does not get a response, it will turn off the green LED and continue to try every 2 minutes until a response is received. SMOkE MAINTENANCE INqUIRy The module sends a smoke maintenance inquiry to the detectors every 24 hours. (Compatible 2-wire detectors only) If a response indicating a mainte- nance problem is received, the red LED on the module will blink once every 5 seconds and a smoke maintenance condition will be indicated to the panel. It is likely that the detector needs to be cleaned or replaced, refer to the detector instruction manual for maintenance instructions. fREEzE TROUBLE INqUIRy The module sends a freeze trouble inquiry to the detectors every four hours. (Compatible i3 Series 2-wire smoke detectors only) If a response indicating a freeze problem is received, the red LED on the module will blink once every 10 seconds and a smoke maintenance condition will be indicated to the panel. TESTING Modules must be tested after installation and following periodic maintenance. Testing should be performed at least once per year. NOTE: Before testing, notify the proper authorities that the system will be tem- porarily out of service. Disable the zone or system to prevent any unwanted alarms. Ez WALk TEST The communication loop between the 2-wire modules and detectors can be manually tested by putting the module and detectors into EZ Walk test mode. This feature is for use with System Sensor detectors (i4 series model COSMO-2W and i3 series model 2WTA-B) installed with the model COSMOD2W module. The EZ Walk loop test verifies the initiating loop wiring and provides visual status indication at each detector: 1. Ensure proper wiring and power is applied. Wait approximately 5 min- utes from power-up before performing the EZ Walk test. The green LED on the module must be blinking indicating the module is in ready/ standby mode to start the EZ Walk mode. 2. Locate the EZ Walk recessed test switch located behind the module cover (See Figure 1). Depress the test switch with a small screwdriver. The yel- low LED will blink showing that the module and detectors are in EZ Walk mode for 5 minutes. 3. Observe the LEDs at each detector to make sure the green LED is double blinking every 5 seconds as listed in Table 3. 4. At the end of the five minute period, the module will terminate EZ Walk and the yellow LED will stop blinking. The EZ Walk test period can be extended by pressing the test switch multiple times. Each press will add 5 minutes of additional time. If a module or detector fails the test, its wiring should be checked. If the module still fails, it should be replaced. Notify the proper authorities when all testing has been completed. NOTE: The EZ Walk loop test should not be used in lieu of functional testing (alarm, trouble and other functional tests) of the system. TABLE 3: Ez WALk TEST DETECTOR MODES DETECTOR GREEN LED DETECTOR RED LED PROPER OPERATION Double Blink 5 Seconds OFF OUT Of SENSITIVIy OFF Double Blink 5 Seconds fREEzE CONDITION OFF Double Blink 10 Seconds SS-500-004 4 I56-3871-001 ©2012 System Sensor System Sensor warrants its enclosed product to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. System Sensor makes no other express warranty for the enclosed product. No agent, representative, dealer, or employee of the Company has the authority to in- crease or alter the obligations or limitations of this Warranty. The Company’s obligation of this Warranty shall be limited to the replacement of any part of the product which is found to be defective in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture. After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return Authorization number, send defective units postage prepaid to: System Sensor, Returns Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to replace units which are found to be defective because of damage, unreasonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the Company’s negligence or fault. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. ThREE-yEAR LIMITED WARRANTy fCC STATEMENT This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installa- tion. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help. COSMO-4W 3.9k RESISTOR (supplied with module) SMOKE POWER (resettable) SMOKE ZONE CO ZONE PanelEOLResistors COSMOD4W EOLRELAY#EOLR-1 ALL CIRCUITS ARE SUPERVISED (EXCEPT TRIGGERS) AND MUST BE POWER LIMITED CO TRIGGER OUT SMOKE TRIGGER OUT BELL OR i4 Series Combination Carbon Monoxide(CO)/Photoelectric Smoke Detector COSMO-4W (4-wire) Wiring Diagram POWER IN + IDC + IDC – POWER IN – CO ALARM CONTACT CO TRIGGER SMOKE ALARM CONTACT MAINTENANCE TROUBLE RELAY CONTACT (COSMOD2W ONLY) SMOKE ZONE EOL RESISTOR (VALUE DEFINED BY PANEL) CO ZONE EOL RESISTOR (VALUE DEFINED BY PANEL) STYLE D/CLASS A + (4-WIRE DETECTOR POWER +) STYLE D/CLASS A – (4-WIRE DETECTOR POWER –) SMOKE TRIGGER / BELL IN ©2013SystemSensor.COFL8102•7/13 COSMOD4W i4 MODULE TERMINALS i4 DETECTORi4 MODULE* PANEL * Module is also compatible with 4WTA-B Smoke Detector ** Triggers are optional and can be used to interconnect multiple modules with a bell output or positive voltage from the panel. Please consult panel manufacturer for programming outputs *** Up to 12 detectors per module; models COSMO-4W or 4WTA-B only. Module interconnects sounders of both devices (RSS-MOD not needed). DIP SWITCH CONFIGURATIONS DIP SWITCH # 1 DIP SWITCH # 2 DIP SWITCH # 3 ON (DEFAULT)Bell In Smoke Maint on Smoke Trouble and Form-B Maint Relay (COSMOD2W only) Unused OFF Smoke Trigger Smoke Maint on Form-B Smoke maintenance Relay only (COSMOD2W only) Unused (4-wire) ** Agency Listings 5600 Series Mechanical Heat Detectors System Sensor’s 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Features Multiple configurations for installations: – Single- and dual-circuit models – Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. Plain housing for residential installations (Model 5601P) Easy-to-use terminal screws A broad range of back box mounting options: – Single gang – 3.5˝ and 4˝ Octagonal – 4˝ square with square to round plaster ring Reversible mounting bracket • • • • • Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit models are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back boxes. And these models accommodate four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. S2101 3016008 199-03-E 7270-1209:227 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2006 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0351-002 • 11/06 • #1676 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number _________, listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 3½-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14–22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601P, 5602, 5621, and 5622 only) Mounting 3½-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact Ratings 6–125VAC / 3A 6–28VDC / 1A 125VDC / 0.3A 250VDC / 0.1A Input Terminals 14–22 AWG Ordering Information Model Circuit Identification Method on Exterior Temperature Rating Activation UL Protected Spacing – 10 Foot Ceiling* 5601P Single None 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5602 Single Lettering 194°F (90°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5603 Single Lettering 135°F (57°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5604 Single Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5621 Dual Lettering 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5624 Dual Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 5601P FX/ROR194°F/9 0 °C5602, 5622 FX135°F/5 7 °C5603, 5623 FX194°F/90 °C 5604, 5624 FX/ROR135°F/5 7 °C5621 PinPoint Addressable Point ID Systems www.GE-Interlogix.com GE Interlogix Product Information Standard Features Single two-wire loop up to two miles means fast and easy installation for new construction or retrofit applications Addressable sensors indicates exact location of alarm or trouble event Supports up to 192 devices Advanced digital communication from the sensors to the panel GE Interlogix — a name you know and trust Supports 3 Class B loops The PinPoint addressable solutions bring together NetworX NX-8E functionality with the reliability of GE Interlogix sensors. Supporting up to 192 devices on a single two-wire loop up to two miles, the PinPoint point ID solution can be installed fast in new construction or retrofit applications. Overview Components NetworX NX-8E Part # NX-8E 4 Input 4 Output Device Part # 4I4O-ID Single Input Device Part # SI-ID ShatterPro® Glassbreak Part # 5845-ID AP Series Motion Sensor Part # AP750-ID PinPoint Interface Card Part # NX-2192E PinPoint Addressable Point ID Systems Description An addressable PIR for use with the NX-2192E Pinpoint ID Bus Interface. Adaptive Single Processing – 3D signal processing with gliding focus mirror optics analyzes size, speed, shape and adaptive alarm threshold. Provides four separate curtain coverage patterns with 50' (15.2 m) range. Flat wall or corner mounting height up to 10' (3m). Ships with two plastic inserts, each covering half the coverage pattern for more flexible mounting options (center curtain always active). Specifications Housing Material Flame retardant ABS Operating voltage 8 to 27V (as supplied by NX-2192E) Current draw 250 µA typical avg. 3mA with LED momentarily on Transmit condition Alarm, tamper Detection range 50 ft (15.2m) Mounting height 6 to 10 ft (1.8 to 3m) Number of curtains 7 Operating temperature 32° to 131°F (0° to 55°C) Relative humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 2.9' (74mm) Depth 2.2' (56mm) Height 5.1' (129mm) Listings UL 639, FCC Features AP750-ID Addressable PIR 45° Left 45° Right 50'15.2m 10'3.0m 4.8' 1.4m Coverage Patterns Description An addressable ShatterPro® II glassbreak for use with the NX-2192E PinPoint ID Bus Interface. ShatterPro's Pattern Recognition Technology™for superior detection and false alarm immunity. Protects all glass types up to a standard thickness of 1/4" (6.4 mm) including plate, wired, tempered and laminated glass. Senses through light blinds and unlined drapes. Suitable for use in occupied areas on the perimeter loop. Specifications Housing material Flame retardant ABS Operating voltage 8 to 27V (as supplied by NX 2192) Current draw 250 µA typical avg. 3mA with LED momentarily on Microphone Omni-directional electret Operating temperature 14° to 120°F (-10° to 50°C) Relative humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 3.13' (80mm) Depth 1.7' (43mm) Height 4.2' (108mm) Listings FCC Features 5845-ID Addressable Shatterpro® Glassbreak 20' (6m) max. Ceiling mount Wall mount 20' (6m)max. Description An addressable single input interface to connect a single non-addressable device to the NX-2192E PinPoint ID bus interface. Supports a single non-addressable device. Utilizes advanced digital data communications protocol that ensures the integrity of the data communication. Specifications Housing material Flame retardant ABS Operating voltage 8 to 27V (as supplied by NX-2192E) Signaling voltage 4 to 9V Current draw 250 µA Operating temperature 32° to 131°F (0° to 55°C) Relative humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 3.3' (84mm) Depth 1.3' (33mm) Height 2.8' (71mm) Listings UL 365, UL 609, UL 985, UL 1023, UL 1610, FCC Features SI-ID Single Input Device Description An addressable 4 input and 4 unsupervised output interface that allows you to connect up to 4 non-addressable devices to the NX-2192E PinPoint ID Bus Interface. Supports four inputs and four unsupervised outputs (horns, bells, sirens, etc.). Utilizes advanced digital data communications protocol that ensures the integrity of the data communication. Specifications Housing material Flame retardant ABS Operating voltage 12 to 30VDC Signaling voltage 4 to 9V Current draw 100 µA (bus loading) Output current 500mA maximum each Operating temperature 32° to 131°F (0° to 55°C) Relative Humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 6.8' (173mm) Depth 2.0' (51mm) Height 4.8' (122mm) Listings UL 365, UL 609, UL 985, UL 1023, UL 1610, FCC Features 4I4O-ID Four Input Four Output Device From PinPoint loop To single non-addressable device, such as a magnetic contact Open Single EOL Double EOL Short >1MΩ 47k±5% 94k±5% >20Ω Input Loop Resistance Reported to panel (47k EOL included) Addressable Inputs To unsupervised outputs, such as horns and sirens Open Single EOL Double EOL Short >1MΩ 47k±5% 94k±5% >20Ω Input Loop Resistance Reported to panel (47k EOL included) PinPoint Addressable Point ID Systems ©2003 GE Interlogix. Smoke! in a Can is a trademark of GE Interlogix. All trademarks are properties of their owners. M-4301-XXXXKA-0103 GE Interlogix www.GE-Interlogix.com 2266 Second Street North North St. Paul, MN 55109 Phone: 651-777-2690 USA & Canada: 800-777-5484 Technical Service: 800-777-2624 12345 SW Leveton Drive Tualatin, OR 97062 Phone: 503-692-4052 USA & Canada: 800-547-2556 Technical Service: 800-648-7424 Faxback: 800-483-2495 NetworX NX-8E control panel PinPoint interface card Ge interlogix PIR Ge interlogix glassbreak Single input device 4 input 4 output device NX-8E NX-2192E AP750-ID 5845-ID SI-ID 4I4O-ID Ordering Information – – White White White White Specifications Current Draw 170 mA standby maximum Operating temperature 32° to 122°F (0° to 50°C) Shipping Weight 0.5 lb. Dimensions Width 2' (51mm) Depth 1.25' (32mm) Height 9' (229mm) Features NX-2192E Description Point ID Bus Interface Card. Attaches to the NX-8E control panel. Bus interface that supports up to 192 addressable devices on a two-mile loop. Supports three class B loops. UL UL UL FCC UL UL Model Description Listing Approvals PinPoint Addressable Point ID Systems